Solutions for UV Systems Electronic Ballasts Electronic...
Transcript of Solutions for UV Systems Electronic Ballasts Electronic...
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 1 -09/2006
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
Solutions for UV Systems 2 Electronic Ballasts for Low Pressure Lamps and Amalgam Lamps 2
Measurement Technique - Monitors and Sensors 4 Digital Operation System - a Bus System for UV Facilities 5
Electronic Ballasts 6 Recommended Lamp-Ballast Combinations 6
Special Lamp-Ballast Combinations 8Electronic Ballasts (4pin-type) 9
EVG 11W...20W / 230V AC/ 115V AC/ 24V DC 9EVG 30...90W / 230V AC 10
EVG 100...200W / 230V AC 11EVG 200...400W / 230V AC 12
Electronic Ballasts as Plug-In Cards for Rack Mounting - R(S)-EVG 200...400W / 230V AC 13 Microprocessor Controlled Electronic Ballasts - P-EVG 200...900W / 230V AC 15
EVG 30...240W / 115V AC 16Single / Twin Electronic Ballasts for Amalgam Lamps - Special Design 18
UV-Compact MC 30...200W OS - with LCD and Integrated Hour Counter 20UV-Compact MC 30...200W - with LCD, Integrated Hour Counter and UV-Monitor 21
UV-Compact MCplus 200...350W - with LCD, Integrated Hour Counter and UV-Monitor 22 Electronic Ballasts (2pin-type) 23
EVG 11W...20W / 230V AC/ 115V AC/ 24V DC 23EVG 20...200W / 230V AC 24EVG 30...150W / 115V AC 26
Accessories for Electronic Ballasts 28Starting Component ESBS01-1/ESBS01 28
Measurement Technique - Monitors and Sensors 29UV-Monitors - Overview 29
Recommended Measurement Combinations of Sensors and Monitors 30UV-Monitor PRO 2 with Status Indication by LED 31
UV-Monitor PRO 3 with Relay Contacts and Status Indication by LED 31UV-Monitor PRO 5/ PRO 8 with Relay Contacts and Status Indication by LED 32
UV-Monitor PRO10.4 with Relay Contacts and Status Indication by LED and LCD 33Service Device and Service Software for UV-Monitor PRO10 34
UV-Monitor PRO11 with Relay Contacts and Status Indication by backlighted LCD 35UV-Monitor PRO15 with Relay Contacts, Status Indication by LCD, Integrated Hour Counter 36UV-Monitor PRO16 with Relay Contacts, Status Indication by LCD, Integrated Hour Counter 37
UV-Monitor PRO20 for Analog and Digital Multi-Sensoring 38UV-Sensors - Overview 39
Silicon Carbide UV-Diodes 40UV-Sensors for Monitoring of Relative UV-Intensities 41
UV-Sensors with Extended Flare Angle (Side-Looking Sensors) 42UV-Sensor SiC007 with various output signals 43UV-Sensor SiC021 with various output signals 44
UV-Sensors adapted to Special Regulations, Calibrated 45Measurement Window MF001 for DVGW-/OENORM/SiC007-Sensors 46Interfaces IF01, IF02, IF03 for the Connection of Sensors and PLC 47
Control Units SW5 and SW10 for Lamp Function Control 48UV-Radiation Meter UVM-CP 49
UV-Lamps and Accessories 50Quartz Tubes / Immersion Tube Lamps 50
Contacts and Lamp Sockets for Low Pressure Lamps / Amalgam Lamps 51
Table Of Content
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 2 -09/2006
! wide variety of ballasts:
ballasts for one, two or four lamp operation
ballasts with integrated hour counter and uv-monitor
power range from 10W to 600W
lamp current from 100mA to 6A
supply voltage 115V AC, 230V AC, 12V DC and 24V DC
! instantaneous start without flicker for long lamp life time
! equipped with power factor correction - CE-conform
! lamp faults are indicated by a potential free relay contact (alarm trigger); LED´s display the current mode of operation
! up to 30% energy saving compared to conventional ballasts
! preheat on request
! microprocessor controlled ballasts with RS485 port for PLC (Programmable Logic Controller) connection
! starting component for delayed power-on of 4 (by cascading up to 16) electronic ballasts
Generals
Why electronic ballasts?The electronic ballast became the standard in the lighting industry. Itleads to significant energy and money savings in nearly every appli-cation. The lamp operation is flicker free and the ballast produces vir-tually no noise or hum.
The incoming 50/60 Hz power (115 or 230 volts) is converted to high-frequency AC (usually 20 to 40 kHz). This leads to a constant gasdischarge compared to conventional ballasts and prevents cathodeflicker.
Electronic ballasts are more efficient than magnetic ballasts in con-verting input power to the proper lamp power. The operation of uv-lamps at higher frequencies reduces end losses, resulting in anoverall lamp-ballast system efficacy increase of 15% to 20%.
Electronic ballasts are directly interchangeable with magnetic bal-lasts. They operate with most of available uv-lamps. Long termusage has demonstrated the reliability of electronic ballasts.
Electronic ballasts that operate two or four lamps at once, are allo-wing the use of a single ballast in systems with several lamps. Thisreduces installation and field wiring costs. Other advantages arereduced weight, quieter operation and reduced lamp flicker.
Electronic ballasts basically consist of the following functional units: filter - EMI-filter to attenuate conducted RF noise rectifier PFC (power factor correction) - provides sinusoidal line
current charging capacitor frequency controller (for high-frequency conversion) power stage resonant tank
and also fault logic (open-circuit / short-circuit protection)
Solutions for UV Systems Electronic Ballasts for Low Pressure Lamps and Amalgam Lamps
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 3 -09/2006
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
Solutions for UV SystemsElectronic Ballasts for Low Pressure Lamps and Amalgam Lamps
Operation Modes of Electronic Ballasts
Preheat start ballasts (-PH)
These ballasts are also used for lamps with four-pin connection.
Preheat ballasts provide a preheat current at the filaments thatallows the electrode to heat up before ignition. During the preheatinterval, voltage across the lamp drops to a level that reduces theunwanted glow current. The ballast applies sufficient voltage to theelectrodes, long enough for the electrode to reach the emissiontemperature to prevent lamp ignition before the electrodes areheated up.
After the end of programmed time for preheating, the ballast app-lies a voltage across the lamp to ignite it with minimal loss of emis-sive material. This optimizes the lifetime of the lamp.
These ballasts are intended for applications with many switch oncycles.
We offer preheat start ballasts on request for lamps with aminimum power of 200W (see the PH in the type name).
Rapid start ballasts
These ballasts are used for lamps with four-pin connection.
During startup a short high current pulse is sent to the lamp fila-ment. This reduces unwanted sputtering of emissive material at theelectrodes.
Compared to instant start ballasts, lamps tend to live longer withrapid start ballasts, in case of many on-off cycles. So rapid startballasts are recommended when the switching cycle for the lampsis more than three times per day.
During operation current is flowing through the lamps filament. Theelectrodes of the lamps must fit with this ballast type.
Instant start ballasts (-IS)
These ballasts are used for lamps with two-pin connection (see theIS in the type name).
Instant start ballasts ignite lamps by applying high voltage acrossthe lamp during setup. The high voltage typically ignites the lampimmediatly. These ballasts do not heat the electrodes.
Instant start ballasts should be used for continously lamp operationwith less than three switches per day. The advantage is the lowerwiring effort compared to four-pin connection.
Instant, rapid or preheat?
There are three modes of operation of the lamps:
! rapid start! preheat start (-PH)! instant start (-IS)
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 4 -09/2006
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
Monitors
! wide variety of monitoring units/monitoring features:
control units for lamp current control
monitoring of relative uv-intensity
monitoring of absoluteuv-intensity
display of specific irradiation by using flow rate measurement and reactor vessel volume for calculation
! comfortable status indication by LCD
! hour counting/lamp lifetime counting
! potential free relay contacts for status indication
! menu-driven handling and programming by buttons or PC-Software for easy adjustment and configuration
! can be integrated easily into existing uv-systems
! customer specific applications on request
Sensors
! wide variety of sensor -(output-) types:
fotodiode
current output
voltage output
sensors adapted to special regulations like German or Austrian rule
! all UV-Sensors operate with SiC diodes
! daylight blind
! watertight up to 10bar possible (depending on the type of sensor)
! stainless steel body (G1/4, G 3/4 outside thread or plug-in body for measurement window MF001)
! side-looking sensors with enhanced angle of incidence for indication of uv-radiation from side
! several supply voltages available
! customer specific adjustment on request
! measurement window MF001 available
! interfaces for the connection of sensors and PLC (programmable logic controller) available
Solutions for UV Systems Measurement Technique - Monitors and Sensors
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 5 -09/2006
Electronic Ballasts Digital Sensors Accessories UV Monitor
P-EVG2x[200...350]W/2...2,1A D-SiC003(-PG)(-F) Interface IF03 for connection of uv-diode output sensors
PRO11
P-EVG800...900W/4...11A D-SLS-SiC003(-PG)(-F) PRO16
RS-EVG220...400W/2...4,8A D-SLS-SiC004(-PG)(-F) PRO20
RS-EVG2x[220...320W]/2...2,2A D-SiC007(-PG)(-F) PLC
D-SiC021(-PG)(-F)
D-SiCDVGW
D-SiCONORM
Digital Operation System Bus System for UV Facilities
unique digital interface for ballasts, sensors, processors and displays
Technical Specification
mains voltage: 230V AC ± 10% CE-conform: yes
mains frequency: 45...65Hz
bus system: RS485 two wire + GND + UB max. bus cable length: 500m
Components
Functions each component identifies itself on the bus
and exchanges information about compo-nent parameters
the system components communicate directly to each other
four wire bus cable connects all compon-ents of the system
interface units can be used to communi-cate with PLC, PC or modem based control-lers and allow remote monitoring
open interface protocol allows third partys adaptions
measurement values and commands are transmitted digitally
exchange of communication and error messages
no additional controller components needed
Advantages digital transmission of signals provides
high noise immunity which allows larger cable length for sensors
lower costs for wiring of the system
setup and service become more easy
extension of the system is possible
very complex systems can be designed
multi-sensoring (mapping of sensors and corresponding UV lamps) can be programmed
Digital Sensor Features absolute value detection
sensor includes several measuring ranges, the measuring range is changed automati-cally depending on the current uv-intensity
no separate sensor adjustment for diffe-rent uv-lamp/sensor arrangements
digital sensors for low pressure lamps: one sensor for the complete output range from 0,1 up to 200W/m²
digital sensors for medium pressure lamps: one sensor for the complete output range from 1,0 up to 2000W/m²
measuring output as plain text with nume-rical value and scale unit
measuring value request by simple stan-dard terminal program (e.g. WINDOWS terminal.exe) or by comfortable customer
Electronic Ballast Features lamp/ballast control
software aided by PLC or standard PC
adjustment of several lamp/ballast para-meters
internal hourmeter
lamp control: on/off, dimming, preheating, status, lamp power/voltage
ballast control: switch-on current=opera-ting current, input voltage control, under-voltage switch-off
dimming with current compensation in the lamps filaments
preheating and cable length compensation
readout of lamp/ballast status (error code), correct connection, filament status, operation hours...
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 6 -02/2007
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
G3
6T5
G6
4T5
GH
O3
6T5
GH
O6
4T5
GIA
12
0G
IA2
00
GIA
24
0G
PH
21
2T5
LG
PH
28
7T5
LG
PH
30
3T5
LG
PH
35
6T5
LG
PH
43
6T5
HO
GP
H4
36
T5
LG
PH
79
3T5
GP
H8
46
T5
GP
H8
46
T5
HO
GP
H8
93
T5
HO
NN
I12
0N
NI2
00
NN
I20
1/
10
7X
LN
NI3
00
/1
47
XL
NN
I40
0N
NI6
0/
25
UN
NI8
0/
36
UT
UV
11
WT5
TU
V1
6T
UV
18
PLL
TU
V2
5T
UV
36
T5
TU
V3
6H
OT
UV
36
PLL
TU
V3
6S
PT
5T
UV
36
T5
TU
V5
5T
UV
60
PLL
TU
V6
4S
PT
5T
UV
64
T5
TU
V6
4T5
HO
TU
V7
5T
UV
95
WH
OP
LL
TU
V1
30
XP
TT
UV
26
0X
PT
TU
V2
70
XP
TT
UV
32
5X
PT
TU
V3
30
XP
TT
UV
24
0W
XP
TU
NI1
20
UN
I20
0U
NI2
01
UN
I26
0U
NI4
0U
NI6
0
230V, rapid start, 4-pin
ST-EVG 11/20 x x xEVG11-20W/425mA x x xEVG18W/370mA xS-EVG30-50W/425mA x x x x xEVG2x[30-50W]/425mA x x x x xUV Compact MC 30-50W/425mA x x x x xS-EVG50-70W/425mA x xEVG2x[50-70W]/425mA x xUV Compact MC 50-70W/425mA x xS-EVG36W/440mA x xEVG2x[36W]/440mA x xS-EVG35-45W/610mA xEVG2x[35-45W]/610mA xUV Compact MC 35-45W/610mA xS-EVG50-70W/670mA x xEVG2x[50-70W]/670mA x xUV Compact MC 50-70W/670mA x xS-EVG50-70W/760mA x x xEVG2x[50-70W]/760mA x x xUV Compact MC 50-70W/760mA x x xS-EVG65-80W/880mA x x xEVG2x[65-80W]/880mA x x xUV Compact MC 65-80W/880mA x x xS-EVG90W/950mA xEVG2x[90W]/950mA xS-EVG40-60W/1,2A x xEVG2x[4060W]/1,2A x xUV Compact MC 40-60W/1,2A x xEVG150-200W/1A x xEVG2x[150-200W]/1A x xUV Compact MC 150-200W/1A x xEVG100-150W/1,5A x x x xEVG2x[100-150W]/1,5A x x x xUV Compact MC 100-150W/1,5A x x x xEVG130W/2,1A xEVG2x[130W]/2,1A xEVG150-200W/1,5A x xEVG2x[150-200W]/1,5A x xUV Compact MC 150-200W/1,5A x xEVG160-200W/2A x x xEVG2x[160-200W]/2A x xUV Compact MC 160-200W/2A x xEVG2x[220W]/2A xR(S)-EVG2x[220W]/2A xUV Compact MCplus 220W/2A xEVG240W/2A x x xP-EVG240W/2A x x xR(S)-EVG240W/2A x x xUV Compact MCplus 240W/2A x x xEVG2x[240W]/2A x x xP-EVG2x[240W]/2A x x xR(S)-EVG2x[240W]/2A x x xEVG270W/3,8A x x
Electronic Ballasts Recommended Lamp-Ballast Combinations
Please note: We offer the adaption of the ballast to your special lamp or we design your own ballast.
see next page ⇒
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 7 -02/2007
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
R(S)-EVG270W/3,8A x xEVG2x[270W]/3,8A x xR(S)-EVG2x[270W]/3,8A x xEVG300W/2,1A xR(S)-EVG300W/2,1A xUV Compact MCplus 300W/2,1A xEVG2x[300W]/2,1A xR(S)-EVG2x[300W]/2,1A xP-EVG2x[300W]/2,1A xEVG320W/2,2A xR(S)-EVG320W/2,2A xUV Compact MCplus 320W/2,2A xEVG2x[320W]/2,2A xR(S)-EVG2x[320W]/2,2A xEVG400W/3,8A xR(S)-EVG400W/3,8A xEVG330W/4,8A xR-EVG330W/4,8A x115V, rapid start, 4-pin
EVG11-20W/425mA -1 x x xS-EVG3050W/425mA -1 x x xEVG2x[30-50W]/425mA -1 x x xEVG5070W/425mA -1 x xEVG2x[50-70W]/425mA -1 x xEVG3545W/610mA -1 xEVG2x[35-45W]/610mA -1 xEVG5070W/670mA -1 xEVG2x[50-70W]/670mA -1 xEVG5070W/760mA -1 x xEVG2x[50-70W]/760mA -1 x xEVG6580W/880mA -1 x x xEVG2x[65-80W]/880mA -1 x x xEVG150-200W/1A -1 xEVG100-150W/1,5A -1 x x x xEVG150-200W/1,5A -1 x xEVG160-200W/2A -1 x xEVG240W/2A -1 x x xEVG300W/2,1A -1 x24V DC, rapid start, 4-pin
EVG11-20W/425mA -4 x x xEVG36W/425mA -4 x x230V, instant start, 2-pin
ST-EVG 11/20 IS x x xEVG11-20W/425mA IS x x xS-EVG30-50W/425mA IS x x xEVG2x[30-50W]/425mA IS x x xS-EVG50-70W/425mA IS x xEVG2x[50-70W]/425mA IS x xS-EVG35-45W/610mA IS xEVG2x[35-45W]/610mA IS xEVG4x[20W]/425mA IS xEVG4x[40W]/425mA IS x x xS-EVG50-70W/760mA IS x xEVG2x[50-70W]/760mA IS x x
G3
6T5
G6
4T5
GH
O3
6T5
GH
O6
4T5
GIA
12
0G
IA2
00
GIA
24
0G
PH
21
2T5
LG
PH
28
7T5
LG
PH
30
3T5
LG
PH
35
6T5
LG
PH
43
6T5
HO
GP
H4
36
T5
LG
PH
79
3T5
GP
H8
46
T5
GP
H8
46
T5
HO
GP
H8
93
T5
HO
NN
I12
0N
NI2
00
NN
I20
1/
10
7X
LN
NI3
00
/1
47
XL
NN
I40
0N
NI6
0/
25
UN
NI8
0/
36
UTU
V1
1W
T5
TU
V1
6TU
V1
8P
LL
TU
V2
5TU
V3
6T5
TU
V3
6H
OTU
V3
6P
LL
TU
V3
6S
PT5
TU
V3
6T5
TU
V5
5TU
V6
0P
LL
TU
V6
4S
PT5
TU
V6
4T5
TU
V6
4T5
HO
TU
V7
5TU
V9
5W
HO
PLL
TU
V1
30
XP
TTU
V2
60
XP
TTU
V2
70
XP
TTU
V3
25
XP
TTU
V3
30
XP
TTU
V2
40
WX
PT
UN
I12
0U
NI2
00
UN
I20
1U
NI2
60
UN
I40
UN
I60
Electronic BallastsRecommended Lamp-Ballast Combinations
Please note: We offer the adaption of the ballast to your special lamp or we design your own ballast.
see next page ⇒
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 8 -02/2007
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
S-EVG65-80W/880mA IS xEVG2x[65-80W]/880mA IS xEVG4x[150W]/1A IS x xEVG150-200W/1A IS xEVG2x[150-200W]/1A IS x115V, instant start, 2-pin
EVG11-20W/425mA IS x x xS-EVG30-50W/425mA IS-1 x x xEVG2x[3050W]/425mA IS-1 x x xEVG50-70W/425mA IS-1 x xEVG2x[5070W]/425mA IS-1 x xEVG35-45W/610mA IS-1 xEVG2x[3545W]/610mA IS-1 xEVG50-70W/760mA IS-1 x xEVG2x[5070W]/760mA IS-1 x xEVG65-80W/880mA IS-1 x xEVG2x[6580W]/880mA IS-1 x xEVG150200W/1A IS-1 x24V DC, rapid start, 4-pin
EVG11-20W/425mA IS -4 x x x
Special Design for LightSources Inc. / LightTech Lamp Technology Ltd.
GP
HA
10
00
T5
L
GP
HA
10
00
T6
L
GP
HA
15
54
T5
L
GP
HA
15
54
T6
L
GP
HA
35
7T5
L
GP
HA
35
7T6
L
GP
HA
84
2T5
L
GP
HA
84
2T6
L
GP
HH
A1
00
0T6
L
GP
HH
A1
55
4T6
L
GP
HH
A3
57
T6
L
GP
HH
A8
42
T6
L
E230.101 x x xR(S)-E230.101 xE230.102 xR(S)-E230.102 xUV Compact MCplus E230.102 xE230.103 xR(S)-E230.103 xUV Compact MCplus E230.103 xS-E230.104 xS-E230.107 xE230.108 x xE230.110 x x xR(S)-E230.110 xUV Compact MCplus E230.111 xE230.201 xR(S)-E230.201 xE230.202 xR(S)-E230.202 xE230.203 xR(S)-E230.203 xE230.204 xE230.205 x xE230.207 xE230.208 x xE230.210 x xE230.211 xR(S)-E230.211 x
G3
6T5
G6
4T5
GH
O3
6T5
GH
O6
4T5
GIA
12
0G
IA2
00
GIA
24
0G
PH
21
2T5
LG
PH
28
7T5
LG
PH
30
3T5
LG
PH
35
6T5
LG
PH
43
6T5
HO
GP
H4
36
T5
LG
PH
79
3T5
GP
H8
46
T5
GP
H8
46
T5
HO
GP
H8
93
T5
HO
NN
I12
0N
NI2
00
NN
I20
1/
10
7X
LN
NI3
00
/1
47
XL
NN
I40
0N
NI6
0/
25
UN
NI8
0/
36
UTU
V1
1W
T5
TU
V1
6TU
V1
8P
LL
TU
V2
5TU
V3
6T5
TU
V3
6H
OTU
V3
6P
LL
TU
V3
6S
PT5
TU
V3
6T5
TU
V5
5TU
V6
0P
LL
TU
V6
4S
PT5
TU
V6
4T5
TU
V6
4T5
HO
TU
V7
5TU
V9
5W
HO
PLL
TU
V1
30
XP
TTU
V2
60
XP
TTU
V2
70
XP
TTU
V3
25
XP
TTU
V3
30
XP
TTU
V2
40
WX
PT
UN
I12
0U
NI2
00
UN
I20
1U
NI2
60
UN
I40
UN
I60
Electronic BallastsSpecial Lamp-Ballast Combinations
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 9 -09/2006
ballast type A
ballast type B
ballast type C
ballast type O
Electronic Ballasts (4pin-type)EVG 11W...36W
230V AC / 115V AC / 24V DC
Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.
Technical Specification
mains frequency: 45...65Hz tc-temperature: max. 50°C CE-conform: yes
operating frequency: 30...50kHz ambient temperature: 0...40°C efficiency: ca. 85%
max. off-load voltage on terminals 1...4:
type A: 1.5kVpp, type B: 600Vrms
status indication: green and red LED indicate operating status, type C: buzzer sounds up if the lamp is not workingphotocoupler, max. current on OG: 5mA (open collector VOG1/0<1V ⇒ VCESAT<1V)
connections: type A, B, O: max. cablelength between ballast and lamp: 0.5m type C: lamp cable, length 1m, provided with 4pin plastic type lamp socket
dimensions (w/h/l): type A, B: (40/36/150)mm, type O: (40/30/190)mmtype C: (121/59/64)mm without plug, cable gland and cable
wire gauge: 0.35-1mm²
mounting restrictions: upright, mains connector at bottom side, see manual for details
*power supply requirements for 24V DC ballast: stabilised, short-circuit proof, inrush current 2A min.
ballast name input voltage [V]
input power [W]
input current [A]
power per lamp [W]
lamp current [A]
ballast type
suitable lamp types (manufacturer model)
ST-EVG 11/20 230V AC ± 10% up to 24 0,05 - 0,11 11-20 0,425 ± 10% CTUV16, GPH287T5L, GPH303T5L
EVG11-20W/425mA 230V AC ± 10% up to 24 0,05 - 0,11 11-20 0,425 ± 10% A
EVG11-20W/425mA -1 115V AC ± 10% up to 24 0,11 - 0,23 11-20 0,425 ± 10% A
EVG11-20W/425mA -4 24V* DC ± 10% up to 24 0,47 - 1,1 11-20 0,425 ± 10% B
EVG18W/370mA 230V AC ± 10% 20 0,08 - 0,1 17 0,370 ± 10% A TUV18PLL
EVG36W/425mA -4 24V* DC ± 10% up to 24 1,7 - 1,8 36 0,425 ± 10% O G36T5, TUV36T5
Available Ballasts
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 10 -09/2006
Ballasts for two lamps are also working if only one lamp is connected.
ballast name input power [W]
input current [A]
lamps per ballast
power per lamp [W]
lamp current [A]
ballast type
suitable lamp types (manufacturer model)
S-EVG30-50W/425mA 32 - 55 0,13 - 0,26 1 30 - 50 0,39 - 0,42 D G36T5, GPH793T5, TUV25, TUV36T5, GPH846T5
EVG2x[30-50W]/425mA up to 110 0,25 - 0,53 2 30 - 50 0,39 - 0,42 F G36T5, GPH793T5, TUV25, TUV36T5, GPH846T5
S-EVG50-70W/425mA 55 75 0,26 - 0,36 1 50 - 70 0,39 - 0,42 D G64T5, TUV64T5
EVG2x[50-70W]/425mA up to 150 0,43 - 0,72 2 50 - 70 0,39 - 0,42 F G64T5, TUV64T5
S-EVG36W/440mA 40 0,16 - 0,19 1 36 0,44 D TUV36, TUV36PLL
EVG2x[36W]/440mA up to 80 0,32 - 0,38 2 36 0,44 F TUV36, TUV36PLL
S-EVG35-45W/610mA 38 50 0,15 - 0,24 1 35 - 45 0,6 - 0,62 D GPH436T5HO
EVG2x[35-45W]/610mA up to 100 0,3 - 0,48 2 35 - 45 0,6 - 0,62 F GPH436T5HO
S-EVG50-70W/670mA 55 75 0,26 - 0,36 1 50 - 70 0,65 - 0,7 D NNI60/25U, TUV60PLL
EVG2x[50-70W]/670mA up to 150 0,43 - 0,72 2 50 - 70 0,65 - 0,7 F NNI60/25U, TUV60PLL
S-EVG50-70W/760mA 55 75 0,26 - 0,36 1 50 - 70 0,75 - 0,77 D GPH846T5HO, GPH893T5HO, TUV55
EVG2x[50-70W]/760mA up to 150 0,43 - 0,72 2 50 - 70 0,75 - 0,77 F GPH846T5HO, GPH893T5HO, TUV55
S-EVG65-80W/880mA 70 85 0,28 - 0,4 1 65 - 80 0,85 - 0,9 D TUV75, GHO36T5, TUV36HO
EVG2x[65-80W]/880mA up to 170 0,55 - 0,8 2 65 - 80 0,85 - 0,9 F TUV75, GHO36T5, TUV36HO
S-EVG90W/950mA 100 0,4 - 0,48 1 90 0,95 D TUV95WHOPLL
EVG2x[90W]/950mA up to 200 0,8 - 0,97 2 90 0,95 F TUV95WHOPLL
S-EVG40-60W/1,2A 44 65 0,17 - 0,31 1 40 - 60 1 - 1,2 D UNI40, UNI60
EVG2x[4060W]/1,2A up to 130 0,34 - 0,62 2 40 - 60 1 - 1,2 F UNI40, UNI60
ballast type D
ballast type F
Electronic Ballasts (4pin-type)EVG 30...90W / 230V AC
ballasts for one and for two lamp operation available
Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.
Technical Specification
mains voltage: 230V AC ± 10% CE-conform: yes efficiency: > 90%
mains frequency: 45...65Hz tc-temperature: max. 50°C
operating frequency: 30...50kHz ambient temperature: 0...40°C
status indication: green and red LED indicate operating statuspotential free relay contact, type D load: 50...200mA at 24...230V AC; 50...500mA at 5V...60V DCtype F load: 50...200mA at 24...120V AC; 50...500mA at 5V...60V DC
wire gauge: type D: 0,5...1mm², type F: 0,75...1,5mm² (type F: max. 0,75mm² for potential free relay contacts)
mounting restrictions: upright, mains connector at bottom side, see manual for details
Available Ballasts
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 11 -09/2006
Ballasts for two lamps are also working if only one lamp is connected.
ballast name input power [W]
input current [A]
lamps per ballast
power per lamp [W]
lamp current [A]
ballast type
suitable lamp types (manufacturer model)
EVG130W/2,1A 140 - 150 0,56 - 0,75 1 130 - 140 2 - 2,1 E TUV130XPT
EVG2x[130W]/2,1A up to 300 1,12 - 1,5 2 130 - 140 2 - 2,1 G TUV130XPT
EVG150-200W/1A 160 220 0,65 - 1,0 1 150 - 200 0,8 1 E GHO64T5, TUV64T5HO
EVG2x[150-200W]/1A up to 440 1,7 - 2,1 2 150 - 200 0,8 - 1 G GHO64T5, TUV64T5HO
EVG100-150W/1,5A 110 - 160 0,43 - 0,77 1 100 -150 1,4 - 1,5 E NNI80/36U, NNI120, UNI120, GIA120, TUV115
EVG2x[100-150W]/1,5A up to 300 0,87 - 1,3 2 100 -150 1,4 - 1,5 G NNI80/36U, NNI120, UNI120, GIA120, TUV115
EVG150-200W/1,5A 160 220 0,65 - 1,0 1 150 - 200 1,4 - 1,5 E GIA200, UNI201
EVG2x[150-200W]/1,5A up to 440 1,7 - 2,1 2 150 - 200 1,4 - 1,5 G GIA200, UNI201
EVG160-200W/2A 175 220 0,7 - 1,1 1 160 - 200 1,85 2 E NNI200, UNI200, NNI201/107XL
EVG2x[160-200W]/2A up to 440 1,7 - 2,1 2 160 - 200 1,85 - 2 G NNI200, UNI200
ballast type E
ballast type G
Electronic Ballasts (4pin-type)EVG 100...200W / 230V AC
ballasts for one and for two lamp operation available
Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.
Technical Specification
mains voltage: 230V AC ± 10% CE-conform: yes
mains frequency: 45...65Hz tc-temperature: max. 50°C
operating frequency: 30...50kHz ambient temperature: 0...40°C
efficiency: > 90%
status indication: green and red LED indicate operating statuspotential free relay contact, load: 50...200mA at 24...120V AC; 50...500mA at 5...60V DC
wire gauge: 0,75...1,5mm²
mounting restrictions: upright, mains connector at bottom side, see manual for details
Available Ballasts
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 12 -09/2006
ballast type H: also available as PREHEAT START version on request (add -PH to ballast name),2-STEP DIMMING on request (add -SD to ballast name)
ballast type I: 4-STEP DIMMING is not standard ⇒ implementation on request (add -SD to ballast name)
ballasts for two lamps are also working if only one lamp is connected
ballast name input power [W]
input current [A]
lamps per ballast
power per lamp [W]
lamp current [A]
ballast type
suitable lamp types (manufacturer model)
EVG2x[220W]/2A 440 - 480 1,74 - 2,31 2 200 - 220 1,9 - 2,2 I NNI201/107XL
EVG240W/2A 250 - 280 0,99 - 1,35 1 220 - 250 1,9 - 2,2 H UNI260, GIA240, TUV240WXPT
EVG2x[240W]/2A 500 - 560 1,98 - 2,7 2 220 - 250 1,9 - 2,2 I UNI260, GIA240, TUV240WXPT
EVG270W/3,8A 280 - 310 1,1 1,5 1 250 -280 3,6 - 4,0 H TUV260XPT, TUV270XPT
EVG2x[270W]/3,8A 560 - 620 2,21 - 3 2 250 -280 3,6 - 4,0 I TUV260XPT, TUV270XPT
EVG300W/2,1A 350 1,38 - 1,7 1 320 2,1 - 2,4 H NNI300/147XL
EVG2x[300W]/2,1A 700 2,76 - 3,38 2 320 2,1 - 2,4 I NNI300/147XL
EVG320W/2,2A 350 1,38 - 1,7 1 320 2,1 - 2,4 H TUV325XPT
EVG2x[320W]/2,2A 700 2,76 - 3,38 2 320 2,1 - 2,4 I TUV325XPT
EVG400W/3,8A 425 1,7 - 2,1 1 400 3,8 H NNI400
EVG330W/4,8A 370 1,46 - 1,79 1 330 4,8 H TUV330XPT
ballast type H
ballast type I
Electronic Ballasts (4pin-type)EVG 200...400W / 230V AC
ballasts for one and for two lamp operation available,PREHEAT START versions available on request (only for one lamp ballast type H)
Technical Specification
mains voltage: 230V AC ± 10% CE-conform: yes
mains frequency: 45...65Hz tc-temperature: max. 50°C
operating frequency: 30...50kHz ambient temperature: 0...40°C
efficiency: > 90%
status indication: green and red LED indicate operating statuspotential free relay contact, load: 50...200mA at 24...230V AC; 50...500mA at 5...60V DC
mounting restrictions: upright, mains connector at bottom side, see manual for details
wire gauge: 0,75...1,5mm²
Available Ballasts
Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.
current approx. 1mA @ 12V DC (voltage range: 9-25V DC)
4-STEP DIMMING scheme lamp A/B current 100% 90% 80% 70%DM 1 A/B 0 0 12V DC 12V DCDM 0 A/B 0 12 V DC 0 12V DC
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 13 -09/2006
ballast type R
ballast type S
ballast type T
ballast type U
Electronic Ballasts (4pin-type)as plug-in cards for rack mounting, microprocessor controlled
R-EVG 200...400W (with RS485: RS-EVG 200...400W) / 230V ACballasts for one and two lamp operation available,
PREHEAT START implemented
electronic ballasts as plug-in cards for rack mounting
preheat start implemented
all connections (mains, lamp and control voltage, error control) routed through a MOLEX JUNIOR FIT connector
microprocessor controlled
type R, S (without RS485):
to be switched on and off externally by 12V...24 DC control voltage
potential free relay contact for fault indication
type T, U (with RS485):
switch-on/-off, dimming and status indication via RS485
addressable with DIP-switch up to 1023
preheat parameters programmable dimmable on request
Features
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 14 -09/2006
Electronic Ballasts (4pin-type)as plug-in cards for rack mounting, microprocessor controlled
R-EVG 200...400W (with RS485: RS-EVG 200...400W) / 230V ACballasts for one and two lamp operation available,
PREHEAT START implemented
Technical Specification
mains voltage: 230V AC ± 10% mains frequency: 45...65Hz
ambient temperature: 0...40°C tc-temperature: max. 50°C
operating frequency: 25...70kHz efficiency: > 90%
control voltage: 12...24V DC (contacts optically isolated)
status indication: green and red LED indicate operating statustype R, S: potential free relay contact, load: 50...200mA at 24...230V AC; 50...500mA at 5...60V DCtype T, U: RS485 for status indication and controlling
mounting restrictions: rack mounting with forced cooling, see manual for details
connections: to be used with MOLEX JUNIOR FIT connector 15-06-0241
wire gauge: 0,75...1,5mm²
Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.
Available Ballasts for Lightsources Inc. / LightTech Lamp Technology Ltd.
ballasts for two lamps are also working if only one lamp is connected
ballast name input power [W]
input current [A]
lamps per ballast
power per lamp [W]
lamp current [A]
ballast type
suitable lamp types (manufacturer model)
R-EVG2x[220W]/2A 440 - 480 1,74 - 2,31 2 200 - 220 1,9 - 2,2 S NNI201/107XL
RS-EVG2x[220W]/2A 440 - 480 1,74 - 2,31 2 200 - 220 1,9 - 2,2 U NNI201/107XL
R-EVG240W/2A 250 - 280 0,99 - 1,35 1 220 - 250 1,9 - 2,2 R UNI260, GIA240, TUV240WXPT
RS-EVG240W/2A 250 - 280 0,99 - 1,35 1 220 - 250 1,9 - 2,2 T UNI260, GIA240, TUV240WXPT
R-EVG2x[240W]/2A 500 - 560 1,98 - 2,7 2 220 - 250 1,9 - 2,2 S UNI260, GIA240, TUV240WXPT
RS-EVG2x[240W]/2A 500 - 560 1,98 - 2,7 2 220 - 250 1,9 - 2,2 U UNI260, GIA240, TUV240WXPT
R-EVG270W/3,8A 280 - 310 1,1 1,5 1 250 -280 3,6 - 4,0 R TUV260XPT, TUV270XPT
RS-EVG270W/3,8A 280 - 310 1,1 1,5 1 250 -280 3,6 - 4,0 T TUV260XPT, TUV270XPT
R-EVG2x[270W]/3,8A 560 - 620 2,21 - 3 2 250 -280 3,6 - 4,0 S TUV260XPT, TUV270XPT
RS-EVG2x[270W]/3,8A 560 - 620 2,21 - 3 2 250 -280 3,6 - 4,0 U TUV260XPT, TUV270XPT
R-EVG300W/2,1A 350 1,38 - 1,7 1 320 2,1 - 2,4 R NNI300/147XL
RS-EVG300W/2,1A 350 1,38 - 1,7 1 320 2,1 - 2,4 T NNI300/147XL
R-EVG2x[300W]/2,1A 700 2,76 - 3,38 2 320 2,1 - 2,4 S NNI300/147XL
RS-EVG2x[300W]/2,1A 700 2,76 - 3,38 2 320 2,1 - 2,4 U NNI300/147XL
R-EVG320W/2,2A 350 1,38 - 1,7 1 320 2,1 - 2,4 R TUV325XPT
RS-EVG320W/2,2A 350 1,38 - 1,7 1 320 2,1 - 2,4 T TUV325XPT
R-EVG2x[320W]/2,2A 700 2,76 - 3,38 2 320 2,1 - 2,4 S TUV325XPT
RS-EVG2x[320W]/2,2A 700 2,76 - 3,38 2 320 2,1 - 2,4 U TUV325XPT
R-EVG400W/3,8A 425 1,7 - 2,1 1 400 3,8 R NNI400
RS-EVG400W/3,8A 425 1,7 - 2,1 1 400 3,8 T NNI400
R-EVG330W/4,8A 370 1,46 - 1,79 1 330 4,8 R TUV330XPT
RS-EVG330W/4,8A 370 1,46 - 1,79 1 330 4,8 T TUV330XPT
lamp type lamp watts [W] lamps per ballast
ballast models ballast power [W]*
ballast input current [A]
ballast type
GPHA1554T5L 196 1 R-E230.101 216 0,95 R
GPHA1554T5L 196 1 RS-E230.101 216 0,95 T
GPHA1554T5L 196 2 R-E230.201 432 1,8 S
GPHA1554T5L 196 2 RS-E230.201 432 1,8 U
GPHA1554T6L 240 1 R-230.102 261 1,14 R
GPHA1554T6L 240 1 RS-230.102 261 1,14 T
GPHA1554T6L 240 2 R-230.202 520 2,38 S
GPHA1554T6L 240 2 RS-230.202 520 2,38 U
GPHHA1000T6L 207 1 R-E230.110 218 0,96 R
GPHHA1000T6L 207 1 RS-E230.110 218 0,96 T
GPHHA1000T6L 207 2 R-E230.211 440 2 S
GPHHA1000T6L 207 2 RS-E230.211 440 2 U
GPHHA1554T6L 320 1 R-E230.103 340 1,52 R
GPHHA1554T6L 320 1 RS-E230.103 340 1,52 T
GPHHA1554T6L 320 2 R-E230.203 680 3,04 S
GPHHA1554T6L 320 2 RS-E230.203 680 3,04 U
Available Ballasts
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 15 -09/2006
ballast name input power [W]
input current [A]
lamps per ballast
power per lamp [W]
lamp current [A]
ballast type
suitable lamp types (manufacturer model)
P-EVG2x[240W]/2A 440 - 500 1,74 - 2,42 2 220 -250 1,9 - 2,2 K UNI260, GIA240, TUV240WXPT
P-EVG2x[300W]/2,1A 700 2,56 - 3,2 2 320 2,1 - 2,4 K NNI300/147XL
P-EVG800W/7A 890 3,5 - 4,3 1 800 4 - 7 N
P-EVG800W/11A 890 3,5 - 4,3 1 800 7 - 11 N
ballast type K
ballast type N
Electronic Ballasts (4pin-type)microprocessor controlled
200...350W/1,9...2,1A up to 500...900W/4...11A / 230V ACballasts for one and two lamp operation for use with Digital Operation System
Technical Specification
mains voltage: 230V AC ± 10% CE-conform: yes
mains frequency: 45...65Hz tc-temperature: max. 50°C
operating frequency: 30...100kHz ambient temperature: 0...40°C
efficiency: > 90%
status indication: green, yellow and red LED indicate operating statuserror codebus communication
wire gauge: 0,75...1,5mm²
mounting restrictions: upright, mains connector at bottom side, see manual for details
Available Ballasts
Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.
Functions: preheat start
switch-on current = operating current
input voltage control
undervoltage switch-off
serial port control features: connection of up to 256 devices via RS485,
loop through possible
switch-on/-off
dimming: 50...100% with current compensation in the lamps filaments
preheating (cable-length compensation)
internal hourmeter
adjustment of several parameters
status readout
Readout: status (errors)
correct connection
lamp power
lamp voltage
dimming status
filament status
operation hours
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 16 -09/2006
ballast type F
ballast type G
ballast type D
ballast type E
ballast type H
Electronic Ballasts (4pin-type)EVG 30...300W / 115V AC
ballasts for one and for two lamp operation availablePREHEAT START versions available on request (only for one lamp ballast type H)
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 17 -09/2006
ballast type H: also available as PREHEAT START version on request (add -PH to ballast name),
ballasts for two lamps are also working if only one lamp is connected.
ballast name input power [W]
input current [A]
lamps per ballast
power per lamp [W]
lamp current [A]
ballast type
suitable lamp types (manufacturer model)
S-EVG3050W/425mA -1 32 - 55 0,25 - 0,53 1 30 - 50 0,39 - 0,42 D G36T5, GPH793T5, TUV36T5
EVG2x[30-50W]/425mA -1 up to 110 0,5 - 1,05 2 30 - 50 0,39 - 0,42 F G36T5, GPH793T5, TUV36T5
EVG5070W/425mA -1 55 75 0,43 - 0,72 1 50 - 70 0,39 - 0,42 E G64T5, TUV64T5
EVG2x[50-70W]/425mA -1 up to 150 0,86 - 1,4 2 50 - 70 0,39 - 0,42 F G64T5, TUV64T5
S-EVG3545W/610mA -1 38 50 0,3 - 0,48 1 35 - 45 0,6 - 0,62 D GPH436T5HO
EVG2x[35-45W]/610mA -1 up to 100 0,6 - 0,96 2 35 - 45 0,6 - 0,62 F GPH436T5HO
EVG5070W/670mA -1 55 75 0,43 - 0,72 1 50 70 0,65 0,7 E NNI60/25U
EVG2x[50-70W]/670mA -1 up to 150 0,86 - 1,4 2 50 70 0,65 - 0,7 F NNI60/25U
EVG5070W/760mA -1 55 75 0,43 - 0,72 1 50 70 0,75 - 0,77 E GPH846T5HO, GPH893T5HO
EVG2x[50-70W]/760mA -1 up to 150 0,86 - 1,4 2 50 70 0,75 - 0,77 F GPH846T5HO, GPH893T5HO
EVG6580W/880mA -1 70 85 0,55 - 0,8 1 65 80 0,85 0,9 E TUV36HO, TUV75, GHO36T5
EVG2x[65-80W]/880mA -1 up to 170 1,1 - 1,6 2 65 80 0,85 - 0,9 G TUV36HO, TUV75, GHO36T5
EVG150-200W/1A -1 160 220 1,26 - 2,1 1 150 0,8 - 1 E GHO64T5
EVG100-150W/1,5A -1 110 - 160 0,86 - 1,55 1 100 - 150 1,4 - 1,5 E NNI80/36U, NNI120, UNI120, GIA120, TUV115
EVG150-200W/1,5A -1 160 220 1,26 - 2,1 1 150 - 200 1,4 - 1,5 H GIA200, UNI201
EVG160-200W/2A -1 175 220 1,4 - 2,1 1 160 - 200 1,85 2 H NNI200, NNI201, UNI200
EVG240W/2A -1 250 - 280 2,0 - 2,7 1 220 - 250 1,9 - 2,2 H UNI260, GIA240, TUV240XPT
EVG300W/2,1A -1 350 2,76 - 3,38 1 320 2,1 - 2,4 H NNI300/147XL
Available Ballasts
Electronic Ballasts (4pin-type)EVG 30...300W / 115V AC
ballasts for one and for two lamp operation availablePREHEAT START versions available on request (only for one lamp ballast type H)
Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.
Technical Specification
mains voltage: 115V AC ± 10% CE-conform: yes
mains frequency: 45...65Hz tc-temperature: max. 50°C
operating frequency: 30...50kHz ambient temperature: 0...40°C
efficiency: > 88%
status indication: green and red LED indicate operating statuspotential free relay contact, type D, H load: 50...200mA at 24...230V AC; 50...500mA at 5...60V DCtype E, F, G load: 50...200mA at 24...120V AC; 50...500mA at 5...60V DC
wire gauge: type D: 0,5...1mm² / type E, F, G, H: 0,75...1,5mm² (type F: max. 0,75mm² for potential free relay contacts)
mounting restrictions: upright, mains connector at bottom side, see manual for details
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 18 -09/2006
*values are depending on the temperature conditions of the lampsballast type H: also available as PREHEAT START version on request, two step dimming on request
Lamp Type Selection
lamp type lamp watts [W] ballast models ballast power [W]* ballast input current [A]
ballast type
GPHA357T5L 42 S-E230.104 50 0,25 D
GPHA842T5L 105 E230.101 118 0,53 E
GPHA1000T5L 127 E230.101 140 0,62 E
GPHA1554T5L 196 E230.101 216 0,95 E
GPHA357T6L 57 S-E230.107 68 0,32 D
GPHA842T6L 127 E230.108 140 0,62 E
GPHA1000T6L 150 E230.108 164 0,74 E
GPHA1554T6L 240 E230.102 261 1,14 H
GPHHA357T6L 65 E230.110 74 0,35 E
GPHHA842T6L 172 E230.110 180 0,79 E
GPHHA1000T6L 207 E230.110 218 0,96 E
GPHHA1554T6L 320 E230.103 340 1,52 H
Technical Data
mains voltage: 230V AC ± 10%, min. mains voltage 192V AC
CE-conform: yes efficiency: > 90%
mains frequency: 45...65Hz tc-temperature: max. 50°C
operating frequency: 30...50kHz ambient temperature: 0...40°C
lamp fault indicator: green and red LED indicate operating statuspotential free relay contact, type E load: 50...200mA at 24...120V AC; 50...500mA at 5...60V DCtype D, H load: 50...200mA at 24...230V AC; 50...500mA at 5...60V DC
mounting restrictions: upright, mains connector at bottom side, see manual for details
wire gauge: type D: 0,5...1mm², type E,H: 0,75...1,5 mm²
ballast type D
Single Electronic Ballasts for Amalgam LampsSpecial Design E230.1**
for LightSources Inc. / LightTech Lamp Technology Ltd.
ballast type E
ballast type H
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 19 -09/2006
Twin Electronic Ballasts for Amalgam LampsSpecial Design E230.2**
for LightSources Inc. / LightTech Lamp Technology Ltd.
ballast type F
ballast type I
ballast type G
For type I ballasts step dimming is possible:
Same diagram for lamp B,current approx. 1mA @ 12V DC(voltage range: 9-25V DC)
Dimming
DM1A DM0A lamp current
0 0 100 %
0 12 V DC 90 %
12 V DC 0 80 %
12 V DC 12 V DC 70 %
*values are depending on the temperature conditions of the lampsballasts for two lamps are also working if only one lamp is connected
Lamp Type Selection
lamp type lamp watts [W]
ballast models
ballast power [W]*
ballast input current [A]
ballast type
GPHA357T5L 42 E230.204 100 0,5 F
GPHA842T5L 105 E230.205 236 1,04 G
GPHA1000T5L 127 E230.205 280 1,24 G
GPHA1554T5L 196 E230.201 432 1,8 G
GPHA357T6L 57 E230.207 136 0,66 F
GPHA842T6L 127 E230.208 280 1,24 G
GPHA1000T6L 150 E230.208 328 1,48 G
GPHA1554T6L 240 E230.202 520 2,38 I
GPHHA357T6L 65 E230.210 148 0,7 F
GPHHA842T6L 172 E230.210 360 1,64 G
GPHHA1000T6L 207 E230.211 440 2 I
GPHHA1554T6L 320 E230.203 680 3,04 I
Technical Data
mains voltage: 230V AC ± 10%, min. mains voltage 192V AC
CE-conform: yes efficiency: > 90%
mains frequency: 45...65Hz tc-temperature: max. 50°C
operating frequency: 30...50kHz ambient temperature: 0...40°C
lamp fault indicator: green and red LED indicate operating statuspotential free relay contact, type F, G load: 50...200mA at 24...120V AC; 50...500mA at 5...60V DCtype I load: 50...200mA at 24...230V AC; 50...500mA at 5...60V DC
mounting restrictions: upright, mains connector at bottom side, see manual for details
wire gauge: 0,75...1,5 mm² (type F: max. 0,75 mm² for terminal 4-9, type I : 0,35...0,5 mm² for terminal 4-9 and 14-19)
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 20 -09/2006
ballast name input power [W]
input current [A]
lamp power [W]
lamp current [A]
lamp type
UV-Compact MC 30-50W/425mA OS 35 - 55 0,13 - 0,22 30 - 50 0,39 - 0,42 G36T5, GPH793T5, TUV25, TUV36T5, GPH846T5
UV-Compact MC 50-70W/425mA OS 55 - 80 0,22 - 0,3 50 - 70 0,39 - 0,42 G64T5, TUV64T5
UV-Compact MC 35-45W/610mA OS 40 - 50 0,15 - 0,2 35 - 45 0,6 - 0,62 GPH436T5HO
UV-Compact MC 50-70W/670mA OS 55 - 80 0,22 - 0,3 50 - 70 0,65 - 0,7 NNI60/25U, TUV60PLL
UV-Compact MC 50-70W/760mA OS 55 - 80 0,22 - 0,3 50 - 70 0,75 - 0,77 GPH846T5HO, GPH893T5HO, TUV55
UV-Compact MC 65-80W/880mA OS 70 - 90 0,28 - 0,35 65 - 80 0,85 - 0,9 GHO36T5, TUV36HO, TUV75
UV-Compact MC 150-200W/1A OS 160 220 0,65 - 0,9 150 - 200 0,8 1 GHO64T5, TUV64T5HO
UV-Compact MC 40-60W/1,2A OS 45 - 65 0,17 - 0,26 40 - 60 1 - 1,2 UNI40, UNI60
UV-Compact MC 100-150W/1,5A OS 110 - 170 0,43 - 0,65 100 - 150 1,4 - 1,5 GIA120, NNI120, NNI80/36U, UNI120
UV-Compact MC 150-200W/1,5A OS 160 - 220 0,65 - 0,87 150 - 200 1,4 - 1,5 GIA200, UNI201
UV-Compact MC 160-200W/2A OS 180 - 220 0,7 - 0,87 160 - 200 1,85 - 2 NNI200, UNI200
Technical Specification
mains voltage: 230V AC ± 10% CE-conform: yes
mains frequency: 45...65Hz ambient temperature:
0...40°C
operating frequency: 30...50kHz efficiency: > 90%
display: 4*20 digits, green, yellow or red back lighting for status indication, adjustment of contrast by menu
handling: menu-driven handling and programming by 4 push-buttons
language: alternatively English or German (other languages on request)
dimensions (w/h/l): (190/72/180)mm weight: 1900g
connections: mains: line cord, cable length 2m
lamp: Hirschmann cable socket CA6GD (Hirschmann cable plug CA6LS is element of delivery, see drawing for connector pin list)
protective earth: cable green/yellow, length 2m
protection class: IP54 if lamp is connected by appropriated plug
Electronic Ballast with Integrated Hour Counter,Multicolour Display
UV-Compact MC 30...200W OS, 230V AC
integrated electronic ballast for uv-lamps
hour counter temperature monitoring synchronous readout of state,
operating hours, time and date multicolour backlighting
(red, green, yellow) for additional status-indication
menu lock
hour counter: internal real time clock global hour counter switch cycle counter programmable user hour counter adjustable end of lamp lifetime alarm
temperature monitoring: measurement of internal temperature internal temperature
can be monitored via menu message internal overheating and
system shutdown in case of temperature above certain switching thresholds
automatic restart can be defined by customer
for use in one-lamp systems
Please note the technical advices and the installation and operating instructions in the UV-Compact MC - Documentation.For use in chemical and biological inactive environment only! To be installed by specialized staff.
Features
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 21 -09/2006
ballast name input power [W]
input current [A]
lamp power [W]
lamp current [A]
lamp type
UV-Compact MC 30-50W/425mA 35 - 55 0,13 - 0,22 30 - 50 0,39 - 0,42 G36T5, GPH793T5, TUV25, TUV36T5, GPH846T5
UV-Compact MC 50-70W/425mA 55 - 80 0,22 - 0,3 50 - 70 0,39 - 0,42 G64T5, TUV64T5
UV-Compact MC 35-45W/610mA 40 - 50 0,15 - 0,2 35 - 45 0,6 - 0,62 GPH436T5HO
UV-Compact MC 50-70W/670mA 55 - 80 0,22 - 0,3 50 - 70 0,65 - 0,7 NNI60/25U, TUV60PLL
UV-Compact MC 50-70W/760mA 55 - 80 0,22 - 0,3 50 - 70 0,75 - 0,77 GPH846T5HO, GPH893T5HO, TUV55
UV-Compact MC 65-80W/880mA 70 - 90 0,28 - 0,35 65 - 80 0,85 - 0,9 GHO36T5, TUV36HO, TUV75
UV-Compact MC 150-200W/1A 160 220 0,65 - 0,9 150 - 200 0,8 1 GHO64T5, TUV64T5HO
UV-Compact MC 40-60W/1,2A 45 - 65 0,17 - 0,26 40 - 60 1 - 1,2 UNI40, UNI60
UV-Compact MC 100-150W/1,5A 110 - 170 0,43 - 0,65 100 - 150 1,4 - 1,5 GIA120, NNI120, NNI80/36U, UNI120
UV-Compact MC 150-200W/1,5A 160 - 220 0,65 - 0,87 150 - 200 1,4 - 1,5 GIA200, UNI201
UV-Compact MC 160-200W/2A 180 - 220 0,7 - 0,87 160 - 200 1,85 - 2 NNI200, UNI200
Technical Specification
mains voltage: 230V AC ± 10% CE-conform: yes
mains frequency: 45...65Hz ambient temperature:
0...40°C
operating frequency: 30...50kHz efficiency: > 90%
display: 4*20 digits, green, yellow or red back lighting for status indication, adjustment of contrast by menu
handling: menu-driven handling and programming by 4 push-buttons
language: alternatively English or German (other languages on request)
dimensions (w/h/l): (190/72/180)mm weight: 1900g
connections: mains: line cord, cable length 2m
uv-sensor: sensor cable, length 1m, with Hirschmann cable plug ELST 5012 (see drawing for connector pin list)
lamp: Hirschmann cable socket CA6GD (Hirschmann cable plug CA6LS is element of delivery, see drawing for connector pin list)
protective earth: cable green/yellow, length 2m
protection class: IP54 if lamp and sensor are connected by appropriated plugs
recommended sensor types:
SiC001-uv-compact, SiC003-uv-compact, SiC007-P-uv-compact with measurement window MF001
Electronic Ballast with Integrated Hour Counter and UV-Monitor,Multicolour Display
UV-Compact MC 30...200W, 230V AC
integrated electronic ballast hour counter temperature monitoring uv-value monitoring synchronous readout of uv-value, uv-state, operating hours,
time and date multicolour backlighting (red, green,
yellow) for additional status-indication menu lock
hour counter: internal real time clock global hour/switch cycle counter programmable user hour counter adjustable end of lamp lifetime alarm temperature monitoring: measurement of internal temperature internal temperature
can be monitored via menu message internal overheating and
system shutdown in case of
temperature above certain switching thresholds
automatic restart can be defined by customer
UV-value monitoring: to be enabled/disabled by customer relative uv-intensity (in %) adjustable uv-low alarm
(two steps: pre alarm - yellow / main alarm - red backlighting)
automatic adjustment of sensitivity
for use in one-lamp systems
Please note the technical advices and the installation and operating instructions in the UV-Compact MC - Documentation.For use in chemical and biological inactive environment only! To be installed by specialized staff.
Features
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 22 -09/2006
ballast name input power [W]
input current [A]
lamp power [W]
lamp current [A]
lamp type
UV Compact MCplus 200W/2A 220 0,79 - 0,97 200 1,85 - 2 NNI201/107XL
UV Compact MCplus 240W/2A 270 - 310 0,87 - 1,21 250 - 280 1,9 - 2,2 GIA240, UNI260
UV Compact MCplus 300W/2,1A 360 1,28 - 1,6 320 2,1...2,4 NNI300/147XL
UV Compact MCplus 320W/2,2A 360 1,28 - 1,6 320 2,1...2,4 TUV325XPT
UV Compact MCplus E230.111 218 0,86 - 1,05 207 GPHHA1000T6L
UV Compact MCplus E230.102 261 1,03 - 1,26 240 GPHA1554T6L
UV Compact MCplus E230.103 340 1,34 - 1,64 320 GPHHA1554T6L
Technical Specification
mains voltage: 230V AC ± 10% CE-conform: yes
mains frequency: 45...65Hz ambient temperature:
0...40°C
operating frequency: 30...50kHz efficiency: > 90%
display: 4*20 digits, green, yellow or red back lighting for status indication, adjustment of contrast by menu
handling: menu-driven handling and programming by 4 push-buttons
language: alternatively English or German (other languages on request)
dimensions (w/h/l): (190/72/180)mm weight: 2000g
connections: mains: line cord, cable length 2m
uv-sensor: BNC-socket
lamp: 4wire lamp cable, length 2m provided with 4pin ceramic type lamp socket
protective earth: cable green/yellow, length 2m
protection class: IP00
recommended sensor types:
SiC001-PG-BNC, SiC003-PG-BNC, SiC007-P-PG-BNC with measurement window MF001, SLS-SiC003-PG-BNC, SLS-SiC004-PG-BNC(2wire cable with BNC-connector, shielded, length 2,0m)
Electronic Ballast with Integrated Hour Counter and UV-MonitorMulticolour Display, Active Cooling
UV-Compact MCplus 200...350W, 230V AC
integrated electronic ballast for uv-lamps
hour counter uv-value monitoring temperature monitoring integrated fan for active cooling synchronous readout
of uv-value, uv-state, operating hours, time and date
multicolour backlighting (red, green, yellow) for additional status-indication
menu lock
hour counter: internal real time clock global hour counter switch cycle counter programmable user hour counter adjustable end of lamp lifetime alarm
UV-value monitoring: to be enabled/disabled by customer relative uv-intensity (in %) adjustable uv-low alarm (two steps:
pre alarm/main alarm automatic adjustment of sensitivity
temperature monitoring: measurement of internal tempera-
ture (optional external temperature) internal temperature can be moni-
tored via menu message internal overheating and
system shutdown in case of tempera-ture above certain switching thres-holds
automatic restart can be defined by customer
for use in one-lamp systems
Please note the technical advices and the installation and operating instructions in the UV-Compact MCplus - Documentation.For use in chemical and biological inactive environment only! To be installed by specialized staff.
Features
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 23 -09/2006
ballast type A
ballast type B
ballast type C
Electronic Ballasts (2pin-type)EVG 11W...20W
230V AC / 115V AC / 24V DC
Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.
Technical Specification
mains frequency: 45...65Hz tc-temperature: max. 50°C CE-conform: yes
operating frequency: 30...50kHz ambient temperature: 0...40°C efficiency: ca. 85%
max. off-load voltage on terminals 1...4:
type A: 1.5kVpp, type B: 600Vrms
status indication: green and red LED indicate operating status, type C: buzzer sounds up if the lamp is not workingphotocoupler, max. current on OG: 5mA (open collector VOG1/0<1V ⇒ VCESAT<1V)
connections: type A, B: max. cablelength between ballast and lamp: 0.5m type C: lamp cable, length 1m, provided with 4pin plastic type lamp socket
dimensions (w/h/l): type A, B: (40/36/150)mmtype C: (121/59/64)mm without plug, cable gland and cable
wire gauge: 0.35-1mm²
mounting restrictions: upright, mains connector at bottom side, see manual for details
*power supply requirements for 24V DC ballast: stabilised, short-circuit proof, inrush current 1,5A min.
ballast name input voltage [V]
input power [W]
input current [A]
power per lamp [W]
lamp current [A]
ballast type
suitable lamp types (manufacturer model)
ST-EVG 11/20 IS 230V AC ± 10% up to 24 0,05 - 0,11 11-20 0,425 ± 10% CTUV16, GPH287T5L, GPH303T5L
EVG11-20W/425mA IS 230V AC ± 10% up to 24 0,05 - 0,11 11-20 0,425 ± 10% A
EVG11-20W/425mA IS -1 115V AC ± 10% up to 24 0,11 - 0,23 11-20 0,425 ± 10% A
EVG11-20W/425mA IS -4 24V* DC ± 10% up to 24 0,47 - 1,1 11-20 0,425 ± 10% B
Available Ballasts
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 24 -02/2007
ballast type E
ballast type D
ballast type G
ballast type F
ballast type J (4 lamp - ballast)
Electronic Ballasts (2pin-type)EVG 20...200W / 230V AC, instant start
ballasts for one, two and four lamp operation available
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 25 -02/2007
Electronic Ballasts (2pin-type)EVG 20...200W / 230V AC, instant start
ballasts for one, two and four lamp operation available
ballast name input power [W]
input current [A]
lamps per ballast
power per lamp [W]
lamp current [A]
ballast type
suitable lamp types (manufacturer model)
S-EVG30-50W/425mA IS 35 - 55 0,14 - 0,26 1 30 - 50 0,39 - 0,42 D G36T5, GPH793T5, TUV36SPT5
EVG2x[30-50W]/425mA IS up to 110 0,28 - 0,52 2 30 - 50 0,39 - 0,42 F G36T5, GPH793T5, TUV36SPT5
S-EVG50-70W/425mA IS 55 75 0,22 - 0,36 1 50 - 70 0,39 - 0,42 D G64T5, TUV64SPT5
EVG2x[50-70W]/425mA IS up to 160 0,44 - 0,7 2 50 - 70 0,39 - 0,42 F G64T5, TUV64SPT5
S-EVG35-45W/610mA IS 38 50 0,15 - 0,24 1 35 - 45 0,6 - 0,62 D GPH436T5HO
EVG2x[35-45W]/610mA IS up to 100 0,3 - 0,48 2 35 - 45 0,6 - 0,62 F GPH436T5HO
EVG4x[20W]/425mA IS up to 85 0,33 - 0,41 4 20 0,42 J GPH436T5L
EVG4x[40W]/425mA IS up to 170 0,65 - 0,8 4 35 0,42 J G36T5, GPH793T5, TUVSP36T5
S-EVG50-70W/760mA IS 55 75 0,22 - 0,36 1 50 - 70 0,75 - 0,77 D GPH846T5HO, GPH893T5HO
EVG2x[50-70W]/760mA IS up to 150 0,44 - 0,7 2 50 - 70 0,75 - 0,77 F GPH846T5HO, GPH893T5HO
S-EVG65-80W/880mA IS 70 85 0,28 - 0,41 1 65 - 80 0,85 - 0,9 D TUV36HO, GHO36T5
EVG2x[65-80W]/880mA IS up to 170 0,56 - 0,8 2 65 - 80 0,85 - 0,9 F TUV36HO, GHO36T5
EVG4x[150W]/1A IS up to 650 2,6 - 3,1 4 150 0,8 - 1,0 L TUV64T5HO, GHO64T5
EVG150-200W/1A IS 165 220 0,65 - 0,97 1 150 - 200 0,8 - 1,0 E GHO64T5
EVG2x[150-200W]/1A IS up to 440 1,3 - 1,9 2 150 - 200 0,8 - 1,0 G GHO64T5
Available Ballasts
Ballasts for two or four lamps are also working if not all lamps are connected.
Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.
Technical Specification
mains voltage: 230V AC ± 10% CE-conform: yes efficiency: > 90%
mains frequency: 45...65Hz tc-temperature: max. 50°C
operating frequency: 30...50kHz ambient temperature: 0...40°C
status indication: green and red LED indicate operating statuspotential free relay contact, type D, L load: 50...200mA at 24...230V AC; 50...500mA at 5...60V DCtype E, F, G, J load: 50...200mA at 24...120V AC; 50...500mA at 5...60V DC
wire gauge: type D: 0,5...1mm² / type E, F, G, J, L: 0,75...1,5mm² (max. 0,75mm² for potential free relay contacts)
mounting restrictions: upright, mains connector at bottom side, see manual for details
ballast type L
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 26 -09/2006
Electronic Ballasts (2pin-type)EVG 30...150W / 115V AC, instant start
ballast type F
ballast type D
ballast type E
ballast type G
ballasts for one and two lamp operation available
Technical Specification
mains voltage: 115V AC ± 10% CE-conform: yes efficiency: > 90%
mains frequency: 45...65Hz tc-temperature: max. 50°C
operating frequency: 30...50kHz ambient temperature: 0...40°C
status indication: green and red LED indicate operating statuspotential free relay contact, type D load: 50...200mA at 24...230V AC; 50...500mA at 5...60V DCtype E, F, G load: 50...200mA at 24...120V AC; 50...500mA at 5...60V DC
wire gauge: type D: 0,5...1mm², type E, F, G: 0,75...1,5mm² (type F: max. 0,75mm² for potential free relay contacts)
mounting restrictions: upright, mains connector at bottom side, see manual for details
see next page for list of ballasts ⇒
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 27 -09/2006
Electronic Ballasts (2pin-type)EVG 30...150W / 115V AC, instant start
ballasts for one and two lamp operation available
Available Ballasts
ballasts for two lamps are also working if only one lamp is connected.
ballast name input power [W]
input current [A]
lamps per ballast
power per lamp [W]
lamp current [A]
ballast type
suitable lamp types (manufacturer model)
S-EVG30-50W/425mA IS-1 32 - 55 0,25 - 0,53 1 30 50 0,39 - 0,42 D G36T5, GPH793T5, TUV36T5
EVG2x[3050W]/425mA IS-1 up to 110 0,5 - 1,05 2 30 50 0,39 0,42 F G36T5, GPH793T5, TUV36T5
EVG50-70W/425mA IS-1 55 75 0,43 - 0,72 1 50 70 0,39 - 0,42 E G64T5, TUV64T5
EVG2x[5070W]/425mA IS-1 up to 150 0,86 - 1,4 2 50 70 0,39 0,42 F G64T5, TUV64T5
S-EVG35-45W/610mA IS-1 38 50 0,3 - 0,48 1 35 45 0,6 - 0,62 D GPH436T5HO
EVG2x[3545W]/610mA IS-1 up to 100 0,6 - 0,96 2 35 45 0,6 0,62 F GPH436T5HO
EVG50-70W/760mA IS-1 55 75 0,43 - 0,72 1 50 70 0,75 - 0,77 E GPH846T5HO, GPH893T5HO
EVG2x[5070W]/760mA IS-1 up to 150 0,86 - 1,4 2 50 70 0,75 0,77 F GPH846T5HO, GPH893T5HO
EVG65-80W/880mA IS-1 70 85 0,55 - 0,8 1 65 80 0,85 - 0,9 E TUV36HO, TUV75, GHO36T5
EVG2x[6580W]/880mA IS-1 up to 170 1,1 - 1,6 2 65 80 0,85 0,9 G TUV36HO, TUV75, GHO36T5
EVG150200W/1A IS-1 160 220 1,26 - 2,1 1 150 -200 0,8 1 E GHO64T5
Please contact us if your lamp requires other technical data. We are able to adapt lamp and ballast in most cases.
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 28 -09/2006
Accessories for Electronic BallastsStarting Component ESBS01-1/ESBS01
for delayed power-on of 4 electronic ballasts (delay time selectable from 0...12s) by DIP-switch),extensible up to 4 starting components/16 electronic ballasts by cascading
Technical Specification
mains voltage: ESBS01-1: 115V AC ± 10% ESBS01: 230V AC ± 10%
mains frequency: 45...65Hz max. constant input current of ballasts (complete):
6A
dimensions (w/h/l):
(97/43/96) mm weight: 400g (0,881lbs)
device delay switch settings:
S1 on: 0s | S3 on: 8sS2 on: 4s | S4 on: 12s
ballast switching time:
ballast 1: device delay +0s | ballast 3: device delay +2sballast 2: device delay +1s | ballast 4: device delay +3s
Example for wiring and switching:
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 29 -09/2006
UV-Monitor PRO 2 with status indication by LED
UV-Monitor PRO 3 with relay contacts and status indication by LED
UV-Monitor PRO 5 with relay contacts and status indication by LED
UV-Monitor PRO 8 with relay contacts and status indication by LED
UV-Monitor PRO 10.4 with relay contacts, status indication by LED and LCD and integrated hour counter
UV-Monitor PRO 11 with relay contacts, status indication by LCD and integrated hour countersynchronous readout of uv-value and operating hoursLCD with green and red back lighting for status indication
UV-Monitor PRO 15with relay contacts, status indication by LCDand integrated hour countersynchronous readout of uv-value and operating hours
UV-Monitor PRO 16with relay contacts, status indication by LCDand integrated hour countersynchronous readout of uv-value and operating hoursLCD with green and red back lighting for status indication
UV-Monitor PRO 20 / PRO 20-S for analog and digital multi-sensoringwith relay contacts, status indication by LCDand integrated hour countersynchronous readout of uv-value and operating hours
Measurement TechniqueUV-Monitors - Overview
for monitoring of the relative and/or absolute uv-intensity
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 30 -09/2006
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
Measurement TechniqueRecommended Measurement Combinations
of Sensors and MonitorsPlease note: We offer the adjustment of the sensors according to your requirements.
PR
O2
PR
O3
PR
O5
PR
O8
PR
O1
0.4
PR
O1
0.4
-U2
PR
O1
0.4
-SLS
PR
O1
1P
I-I
PR
O1
1P
U3
-I
PR
O1
5
PR
O1
5-S
LS
PR
O1
6P
PR
O1
6I(
-I)
PR
O1
6U
3(-
I)
PR
O1
6P
I(-I
)
PR
O1
6P
U3
(-I)
PR
O2
0
UV
-Co
mp
act
IF0
1
IF0
2
IF0
3
SiC-SV01 x x x x x x x x x x x x x x x xSiC001 x x x x x x x x x x x x x x x xSiC001-PG x x x x x x x x x x x x x x x xSiCT001-PG x x x x x x x x x x x x x x x xSiC003 x x x x x x x x x x x x x x x xSiC003-PG x x x x x x x x x x x x x x x xSLS-SiC003 x xSLS-SiC003-PG x xSLS-SiC004 x xSLS-SiC004-PG x xSiC007-P x x x x x x x x x x x x x x x xSiC007-P-PG x x x x x x x x x x x x x x x xSiC007-I x x x x xSiC007-I-PG x x x x xSiC007-U2 x xSiC007-U2-PG x xSiC007-U3 x x x xSiC007-U3-PG x x x xSiC007-U10 xSiC007-U10-PG xSiC021-I x x x x xSiC021-I-PG x x x x xSiC021-U2 x xSiC021-U2-PG x xSiC021-U3 x x x xSiC021-U3-PG x x x xSiC021-U10 xSiC021-U10-PG xSiCDVGW001-LP x xSiCDVGW001-MP x xSiCDVGW002-LP x x x x xSiCDVGW002-MP x x x x xSiCONORM001-LP x xSiCONORM001-MP x xSiCONORM002-LP x x x x xSiCONORM002-MP x x x x x
Sensors and Monitors for the Digital Operation System
Digital Sensors Accessories UV-Monitors
D-SiC003(-PG)(-F) Interface IF03 for connection of analog (uv-diode out-put)sensors:
PRO11
D-SLS-SiC003(-PG)(-F) PRO16
D-SLS-SiC004(-PG)(-F) PRO20
D-SiC007(-PG)(-F) SiC-SV01 PLC
D-SiC021(-PG)(-F) SiC001(-PG)
D-SiCDVGW SiCT001-PG
D-SiCONORM SiC003(-PG)
SiC007-P(-PG)
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 31 -09/2006
Measurement TechniqueUV-Monitor PRO 2 with Status Indication by LED
UV-Monitor PRO 3 with Relay Contacts and Status Indication by LEDfor monitoring of the relative uv-intensity, e.g. in uv disinfection systems
PRO 2
PRO 3
Functions: display of the relative uv-output with three
LED's:
# GREEN: function o.k.# YELLOW: pre-alarm# RED: main alarm
PRO 3: potential free relay contact in accordance with status indication for main alarm
multi turn potentiometer for fine adjustment of sensitivity at 110%, shown through a green LED nearby the potentiometer
Attention: Risk of electric shock!
The device must be installed in a closed cabinet, otherwise lethal parts can be touched by hand. The device may be installed by authorized personnel only, to make sure all applicable safety rules are fulfilled.
Please consider the safety instructions in the installation and operating manual.
Technical Specification
mains voltage: 230V AC ± 10% /50/60 Hz(115V AC/60Hz or 24V DC types available on request)
operating temperature:
0...40°C storage temperaturerange:
-40°C...+70°C
measurement range: adjustable for customer purpose by manufacturer
status indication: 3 LED: green: function o.k. yellow: pre-alarm red: main alarm
switching thresholds:
red: 0 - 49% (main alarm)yellow: 50 - 74% (pre-alarm)green: > 74% (function o.k.)(or customers specification)
dimensions (w/h/l): (75/49/41)mm mounting: 4 mounting holes ∅ 3,8mmhole center distance: (65 x 38)mm
For use in dry environment only!
monitor type
sensor signal relay contact weight suitable sensor types
PRO2 diode output no relay contact 120g SiC-SV01, SiCT001-PG, SiC001(-PG), SiC003(-PG), SiC007-P(-PG)
PRO3 diode output potential free relay contact, load: 5mA...1A/5V...230V AC 5mA...1A/5V...60V DC relay threshold 50%
150g
Available Monitor Types
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 32 -09/2006
Measurement TechniqueUV-Monitor PRO 5/ PRO 8 with Relay Contacts
and Status Indication by LEDfor monitoring of the relative uv-intensity, e.g. in uv disinfection systems
PRO 5
PRO 8
PRO 5-PF
Functions display of the relative uv-output with three
LED's:
# GREEN: function o.k.# YELLOW: pre-alarm# RED: main alarm
potential free relay contacts in accordance with status indication:
# PRO 5: main alarm # PRO 8: pre-alarm, main alarm
multi turn potentiometer for fine adjust-ment of sensitivity at 110%, shown through a green LED nearby the potentio-meter (available at front or back side of the monitor)
For use in dry environment only!
monitor type
sensor signal
suitable sensor types
switching thresholds
relay contact load potentiometer for fine adjust-ment
dimensions (w/h/l):
mounting weight
PRO5-PF diode output
SiC-SV01, SiCT001-PG,SiC001, SiC001-PG, SiC003, SiC003-PG, SiC007-P, SiC007-P-PG
red: 0...49% (main alarm)
yellow: 50...74% (pre-alarm)
green: > 74% (function o.k.)
(or customers specification)
50...200mA/24V...230V AC100...500mA/24V...60V DC
at front side (72/72/77) mm
cut-out according DIN43700 (68+0,7x 68+0,7)
240g
PRO5 diode output
50...200mA/24V...230V AC100...500mA/24V...60V DC
at back side (72/72/77) mm
cut-out according DIN43700 (68+0,7x 68+0,7)
240g
PRO8 diode output
50...200mA/24V...230V AC50...500mA/24V...60V DC
at back side (96/48/80) mm
cut-out according DIN43700 (92+0,8x 45+0,6)
250g
Available Monitor Types
Technical Specification
mains voltage: 230V AC ± 10% /50/60 Hz(115V AC/60Hz or 24V DC types available on request)
operating temperature:
0...40°C storage temperaturerange:
-40°C...+70°C
measurement range: adjustable for customer purpose in wide range
status indication: LED green: function o.k.LED yellow: pre-alarmLED red: main alarm
relay contact for alarm:
potential free relay contact
Accessories - cover for uv monitors for protection level IP65 at front
cover for UV-Monitor PRO5
cover for UV-Monitor PRO8
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 33 -09/2006
Measurement TechniqueUV-Monitor PRO10.4 with Relay Contacts
and Status Indication by LED and LCDfor monitoring and evaluation of relative and absolute uv-intensity (depending on sensor type)
and for displaying the specific irradiation, determined from flow rate measurement and reactor vessel volume
Functions: LCD-Display: uv-intensity in % or W/m²
(in case of calibrated sensor); 3 front LED: operating status
accepts a wide variety of sensor types: photo diodes, current sensors (Austrian ÖNORM or German DVGW), voltage sensors on request
adjustment of end value in %:# coarse adjustment of
sensitivity* in 8 steps, # fine adjustment in a small range
by special multi turn potentiometer (if a photodiode is used),
# display of 110% - value at rear panel (green LED flashes)
adjustment of end value in W/m²
depending on the sensor type* (using a calibrated sensor with standard current port: 4-20mA, 0-20 mA; 0-2 V on request)
two potential free relay contacts indicate pre alarm and main alarm condition, swit-ching thresholds can be programmed*
internal real time clock for counting purposes*
internal hour counter to determine the total operation time of the system
user programmable hour counter e.g. for counting operation hours of the lamps
end of lamp life time display*, after reaching the programmed value the yellow LED is blinking
two display modes to display either uv-intensity value or the user programmable
hour counter, switched by a switch input at the rear side of the device
contact for fault of lamp alarm; by shorting this contact externally the red LED is blin-king and the main alarm relay operates
input to sense operation mode "UV-off". If the unit does not work continuously this contact stops counting of operation hours and uv measuring, the last counter reading remains stored; to prevent alarm during starting up or switching on again, a delay time can be programmed*
internal operating cycle counter*
RS232 - port for service at the rear panel of the device
*can be programmed by manufacturer and/or by customer by service device SER10 orby PC (software MONITOR_ORGANIZERrequired)
Technical Specification
mains voltage: 230V AC ± 10% /50/60 Hz(115V AC/60Hz or 24V DC types available on request)
operating temperature:
0...45°C protection level: IP00(IP65 at front on request)
measurement range: adjustable for customer purpose in wide range output signal: 4-20mA
status indication: LCD: 3 digits, 9mm heigth
3 LED (front): green: function o.k. yellow: pre-alarm red: main alarm
1 LED (back): adjustment of sensitivity green: >110%
relay contact for alarm:
potential free relay contact relay contact load: 50-500mA at 24V-230V AC100-500mA at 24V-60V DC
dimensions (w/h/l): (96/48/134)mm mounting: cut-out according DIN43700 (92+0,8 x 45+0,6)
weight: 300g
For use in dry environment only!for side looking sensors please order uv-monitor PRO10.4 SLS
monitor type sensor signal suitable sensor types
PRO10.4 diode output or current output
SiC-SV01, SiC001(-PG), SiCT001-PG, SiC003(-PG), SiC007-P(-PG), SiC007-I(-PG), SiC021-I(-PG), SiCDVGW002-LP, SiCDVGW002-MP, SiCONORM002-LP, SiCONORM002-MP
PRO10.4-U2 diode output or voltage output
SiC-SV01, SiC001(-PG), SiCT001-PG, SiC003(-PG), SiC007-P(-PG), SiCDVGW001-LP, SiCDVGW001-MP, SiCONORM001-LP, SiCONORM001-MP, SiC007-U2(-PG), SiC021-U2(-PG)
PRO10.4-SLS diode output side looking sensors: SLS-SiC003(-PG), SLS-SiC004(-PG)
Available Monitor Types
Accessories - cover for uv monitors for protection level IP65 at front
cover for UV-Monitor PRO10
Accepted by DVGW and OENORM
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 34 -09/2006
Measurement TechniqueService Device and Service Software for UV-Monitor PRO10
for the adjustment of the uv system parameters
SER10 MONITOR_ORGANIZER
Functions: automatic change to the service mode,
after the connection of the service device
display and setting of the internal monitor clock
display of the total operating hour counter
display and reset of the user programmable hour counter
set of lamp operation time
display and change of the delay time after "UV-off"
display and change of the threshold for main alarm
display and change of the threshold for pre alarm
configuring of sensor input (current input or fotodiode)
coarse adjustment of input sensitivity (8 steps) if a fotodiode is used
adjustment of end value (1...1999W/m²) if a current or voltage sensor is used
display and reset of the operating cycle counter
a 9V block battery is required
Technical Specification SER10
power supply: 9V (battery or accumulator)
operating temperature: 0...45°C
storage temperature range:
-40°C...+60°C
weight: 200g
accessories: interface cable, instructions
status indication: LCD 3 digits, 9mm heigth
dimensions (w/h/l): (60/125/25)mm
protection level: IP00
For use in dry environment only!
Functions: display of all data from the UV-Monitor PRO10
setting and storage of new configurations at the Monitor PRO10
adjustment of the alarm value thresholds for operation of the potential free relay contacts
display and change of the delay time after "UV-off"
display of the operating cycle counter
setting of lamp operation time
special function to turn on and off of a pump contact (by request)
display of total hour counter
display and change of user programmable hour counter
selection of a standard current port
date/ time adjustment
selection of sensor input
special function for calculating of specific irradiation based on intensity, flow rate and reactor vessel volume on request
configuration can be saved at PC harddisk
language can be adapted
Software MONITOR_ORGANIZER V2.02eng Service device SER10
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 35 -09/2006
Measurement TechniqueUV-Monitor PRO11 with Relay Contacts
and Status Indication by backlighted LCDfor monitoring and evaluation of relative and absolute uv-intensity (depending on sensor type)
and for displaying the specific irradiation, determined from flow rate measurement and reactor vessel volume
Technical Specification
mains voltage: 230V AC ± 10% /50/60 Hz(115V AC/60Hz or 24V DC types available on request)
operating temperature:
0...45°C protection level: IP00(IP65 at front on request)
measurement range: automatic adjustment output signal: 4...20mA (potential free)
status indication: LCD: 2*12 digits, 14,5mm heigth backlight colour: green: function o.k., yellow: pre alarm, red: main alarm
relay contact for alarm: 2 potential free relay contacts relay contact load:
50-500mA at 24V-230V AC100-500mA at 24V-60V DC
dimensions (w/h/l): (96/48/114)mm mounting hole: cut-out according DIN43700 (92+0,8 x 45+0,6)
weight: 300g
For use in dry environment only!for side looking sensors please order uv-monitor PRO11SLS
Accessories - cover for uv monitors for protection level IP65 at front
cover for UV-Monitor PRO11
Functions: LCD-Display:
# synchronous readout of uv-value (1st row of display) and operating hours (2nd row of display),
# green (normal), yellow (pre-alarm) and red (main alarm) back lighting,
# uv-intensity in %, W/m² or mW/cm² (in case of calibrated sensor)
accepts a wide variety of sensor types: photo diodes, current sensors, voltage sensors on request
automatic adjustment of end value (using a photodiode)
adjustment of end value in W/m² depen-ding on the sensor type*
(using a calibrated sensor)
two potential free relay contacts indicate pre alarm and main alarm condition, swit-ching thresholds can be programmed*
internal real time clock for counting purposes*
internal hour counter to determine the total operation time of the system
user programmable hour counter e.g. for counting operation hours of the lamps
end of lamp life time display*, after reaching the programmed value display shows "exchange lamp"
contact for fault of lamp alarm; by shorting this contact externally the display shows "lamp error"
input to sense operation mode "UV-off";
if the unit does not work continuously this contact stops counting of operation hours and uv measuring, the last counter reading remains stored; to prevent alarm during starting up or switching on again, a delay time can be programmed*
internal operating cycle counter*
RS232 - port for service at the rear panel of the device
optional RS485 - port for digital operation system
language can be adapted
*can be programmed by manufacturer and/or by customer
monitor type sensor signal suitable sensor types
PRO11PI-I diode output or current output
SiC-SV01, SiC001(-PG), SiCT001-PG, SiC003(-PG), SiC007-P(-PG), SiC007-I(-PG), SiC021-I(-PG), SiCDVGW002-LP, SiCDVGW002-MP, SiCONORM002-LP, SiCONORM002-MP
PRO11PU3-I diode output or voltage output
SiC-SV01, SiC001(-PG), SiCT001-PG, SiC003(-PG), SiC007-P(-PG), SiC007-U3(-PG), SiC021-U3(-PG)
Available Monitor Types
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 36 -09/2006
monitor type supply suitable sensor types
PRO15 /230V AC 230V AC ± 10% 50/60Hz 1,8W SiC-SV01, SiC001(-PG), SiCT001-PG, SiC003(-PG), SiC007-P(-PG) on request:SLS-SiC003(-PG), SLS-SiC004(-PG)
PRO15 /115V AC 115V AC ± 10% 50/60Hz 1,8W
PRO15 / 12V DC 12V DC ± 10% 50/60Hz 1,8W
PRO15 / 24V DC 24V DC ± 10% 50/60Hz 1,8W
Available Monitor Types
Monitoring Features synchronous readout
of uv-value (1st row of display) and operating hours (2nd row of display)
menu operation by buttons
uv-value monitoring: relative uv-intensity (in %)
message "UV-value low" in case of uv-value below switching threshold
adjustment of sensitivity (automatic end adjustment)
hour counter: internal real time clock
total operation time
programmable lamp hour counter
programmable lamp lifetime
message "exchange lamp" in case of reached end of lamp lifetime
Technical Specification
mains voltage: see monitor type CE-conform: yes
mains frequency: 45...65Hz ambient temperature:
0...40°C
display: 2*8 digits, adjustment of contrast by potentiometer
handling: menu-driven handling and programming by 3 push-buttons
language: alternatively English or German (other languages on request)
dimensions (w/h/l): (72,5/44/72,5)mm weight: 170g
relay contact for alarm: potential free relay contact load: 50-200mA at 24V-120V AC50-500mA at 5V- 24V DC
pin assignment:pin 3: normally off contactpin 4: change-over contactpin 5: normally on contact
running time of the clock:
approx. 8 years
Monitor Pro15 types for sidelooking sensors (SLS) available on request
Measurement TechniqueUV-Monitor PRO15 with Relay Contacts, Status Indication by LCD,
Integrated Hour CounterThe monitor is intended for monitoring of the relative uv-intensity.
Please consider the safety instructions in the installation and operating manual.For use in dry environment only!
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 37 -09/2006
Measurement TechniqueUV-Monitor PRO16 with Relay Contacts, Status Indication by LCD,
Integrated Hour CounterThe monitor is intended for monitoring of absolute/relative uv-intensity.
Features
various input types
uv intensity - absolute measurement by using a calibrated sensor- relative measurement by using a photodiode
automatic sensitivity adjustment (photodiode)
2*12 digit display (red/green backlight)
internal clock
global and user hour counter
adjustable end of lamp lifetime alarm
adjustable uv-low alarm
fault relay - potential free relay contact
menu lock
Available Monitor Types
PR
O1
6P
PR
O1
6I
PR
O1
6U
3
PR
O1
6I-
I
PR
O1
6U
3-I
PR
O1
6P
I
PR
O1
6P
U3
PR
O1
6P
I-I
PR
O1
6P
U3
-I
photodiode input x x x x x4...20mA current input x x x x0...3V voltage input x x x x4...20mA current output x x x xabsolute measurement x x x x x x x xrelative measurement x x x x x x x x xsensor power supply +12V DC stabilised x x x x x x x x
Technical Specification
mains voltage: 230V AC ± 10% 50/60Hz 2W CE-conform: yes
mains frequency: 45...65Hz ambient temperature: 0...40°C
display: 2*12 digits, green or red back lighting for status indication, adjustment of contrast by menu
handling: menu-driven handling and programming by 3 push-buttons
language: alternatively English or German
dimensions (w/h/l): (72,5/44/72,5)mm weight: 200g
relay contact: load: 20-200mA at 24V-120V AC / 20-500mA at 5V- 24V DC
running time of the clock: approx. 8 years
2*12 display
buttons
real time clock
memory
relay
power supply
photodiode input
(PRO16Px-x)
4...20mA input
( )PRO16xI-x
0...3V input
( )PRO16xU3-x
4...20mA output
(PRO16xx-I)
central
processing
unit
Dimensions Block schematic
Please consider the safety instructions in the installation and operating manual.For use in dry environment only!
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 38 -09/2006
Measurement TechniqueUV-Monitor PRO20 for Analog and Digital Multi-Sensoring
for monitoring and evaluation of relative and absolute uv-intensity(depending on sensor type)
and for displaying the specific irradiation,determined from flow rate measurement and reactor vessel volume
PRO 20 PRO 20-S
Technical Specification
mains voltage: 230V AC ± 10% /50/60 Hz(115V AC/60Hz or 24V DC types available on request)
operating temperature:
0...45°C protection level: IP00(IP65 at front on request)
sensor ports: 4 diode-output-sensors (optional: current or voltage output)
2 additional inputs for current-output sensors or flow meter
suitable sensor types:
P-SiC003, P-SiC003-PG, P-SiC007, P-SiC021, P-SLS-SiC003, P-SLS-SiC004P-SiCDVGW, P-ONORM
with Interface IF03: SiC-SV01, SiC001, SiC001-PG, SiCT001-PG
additional ports: 4 optic isolated gate inputs3 potential free relay contacts (change-over contact)1 potential free output 4...20mA
1 RS485 interface for digital sensor bus (digital operation system)1 measurement input for temperature1 RS232-port for service
relay contact load: 50-500mA at 24V-230V AC100-500mA at 24V-60V DC
measurement range: adjustable for customer purpose in wide range
status indication: LCD 4*20 digits with green, yellow and red back lighting for status indication
internal buzzer (disengageable)
dimensions (w/h/l): with housing (PRO 20): (143/143/67)mm
without housing (PRO 20-S): (134/134/45)mm
weight: 300g mounting: cut-out according DIN43700 (138+1,0 x 138+1,0)
For use in dry environment only!
Functions: LCD-Display:
# different (customer specific) display modes,
# green, yellow and red back lighting,
# uv-intensity in % or W/m² (in case of calibrated sensor)
accepts a wide variety of sensor types: photo diodes, current sensors (Austrian OENORM or German DVGW), voltage sensors on request
automatic adjustment of end value
adjustment of end value in W/m² depending on the sensor type* (using a calibrated sensor with standard current port: 4-20mA; 0-20 mA; 0-2 V on request)
input for temperature sensor
three potential free relay contacts indicate pre alarm and main alarm condition, swit-ching thresholds can be programmed
four optic isolated gate inputs for switching purposes
internal buzzer (disengageable) for status indication
internal real time clock for counting purposes
internal hour counter to determine the total operation time of the system
user programmable hour counter e.g. for counting operation hours of the lamps
end of lamp life time display, after reachingthe programmed value display shows "exchange lamp"
contact for fault of lamp alarm; by shorting this contact externally the display shows "error lamp"
calculation of the specific irradiation by Ee and flow
language can be adapted
extensive customer specific menu system editable (different languages)
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 39 -09/2006
Silicon Carbide UV Diode SiC-0,1/SiC-0,1-F/SiC-0,25 for ZED UV sensors
UV-Sensor SiC001/SiC001-PG with diode output
UV-Sensor SiC001T-PG teflon sensor with diode output
UV-Sensor SiC003/SiC003-PG with diode output
UV-Sensor SLS-SiC003/SLS-SiC003-PG side-looking sensor with amplified diode output
UV-Sensor SLS-SiC004/SLS-SiC004-PG side-looking sensor with amplified diode output
UV-Sensor SiC007-x / SiC007-x-PGwith diode, current or voltage output
UV-Sensor SiC021-x / SiC021-x-PG with current or voltage output
UV-Sensor SiCDVGWx/SiCONORMx according to German rule W294 / Austrian rule OENORMwith voltage or current output
UV-Sensor SiC-SV01 with diode output
Measurement TechniqueUV-Sensors - Overview
for measurement in uv-units
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 40 -09/2006
SiC-0,1 SiC-0,25SiC-0,1-F
(with uvc-filter)
Silicon Carbide UV Diodesfor ZED UV Sensors
exclusively for uv measurement, e.g. monitoring of sterilistaion lamps or flame monitoring
Shielding connection must not be used as earth connection for safety reasons.
body: TO 18 (SiC-0,1, SiC-0,25: diode is electrically isolated from housing)
operation temperature: -25°C...70°C storage temperature: 0°C...100°C
soldering temperature: 260°C (3s max.)
diode name spectral range [nm]
uv sensitive area [mm²]
max. uv sensitivity on λmax = 275nm
max. uv sensitivity on λmax = 254nm
dark current [fA] on VR =1V
short-circuit current [nA]on bright sun/cloudy sky
reverse voltage [V]
capacity [pF]
SiC-0,1 210...380 0,0625 0,13 A/W 0,11 A/W 1 50/20 20 21
SiC-0,1-F 210...280 0,0625 1 - 20 21
SiC-0,25 210...380 0,25 1 50/20 20 21
Technical Specification
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 41 -09/2006
PG versions without plug connection between sensor and cable.
Sensor SiC003(-PG) is also available as digital sensor for digital operation system, please order D-SiC003(-PG).
SiC-SV01, SiC001(-PG), SiC003(-PG), SiCT001-PG require interface IF03 for interconnection with digital operation system.
The sensors are daylight blind (see diagramm) and standard without uvc-filter. Limitation of spectral sensitivity with uvc-filter is available on request for use with medium pressure lamps. Add -F for sensor with uvc filter.
type thread/length for mounting
wrench size [mm]
diameter [mm]
length [mm] weight [g] suitable monitor types
SiC-SV01 - - 17,5 38,5 140 (including 1m cable)PRO2, PRO3, PRO5, PRO8, PRO10.4, PRO11PRO15, PRO16, IF01, IF02, IF03
SiC001 G 1/4 / 14mm 19 21,7 49 (with plug: 84) 55 (+115g cable and plug)
SiC001-PG G 1/4 / 14mm 19 21,7 61 125 (including 1m cable)
SiCT001-PG G 1/4 / 14mm 17 20 57 85 (including 1m cable)
SiC003 G 3/4 / 11mm 32 37 52 (with plug: 87) 195 (+115g cable and plug)
SiC003-PG G 3/4 / 11mm 32 37 63 270 (including 1m cable)
SiC001 for UV-Compact1
G 1/4 / 14mm 19 21,7 49 55 (no additional cable) UV Compact MC
SiC001-PG-BNC G 1/4 / 14mm 19 21,7 61 180 (including 2m cable) UV Compact MCplus
SiC-SV01 SiC003
SiC001
SiC003-PG SiCT001-PG
SiC001-for UV-Compact SiC001-PG SiC001-PG-BNC
Measurement TechniqueUV-Sensors for Monitoring of Relative UV-Intensities
to be used for measurement in UV-units
Shielding connection must not be used as earth connection for safety reasons.
Technical Specification
diode type: silicon carbide (SiC) 0,0625mm²(SiCT001-PG: 0,25mm²)
body: stainless steel 1.4305(SiCT001-PG: Teflon)
spectral range: 210...380nm (with uvc-filter: 210...280nm)
flare angle: 26°
max. pressure: SiC001(-PG)/SiCT001-PG/SiC003(-PG):10bar SiC-SV01: diode is sealed with quartz window-pro-tection against humidity only
operating temperature: 0...40°C
connection: 2wire cable, shielded:SiC001/SiC003: mounting cable with straight connector M12, length 2.90m(IP65 if inserted and screwed with straight M12 connector)SiC-SV01, SiC001-PG, SiCT001-PG, SiC003-PG: mounted cable, length 1m (up to 2,90m on request)SiC001 for UV-Compact: no additional cable (cable with straight connector M12 already mounted on UV Compact MC)SiC001-PG-BNC: mounted cable with BNC-Plug for connection to UV Compact MCplus
mounting restrictions:
cover thread with teflon tape or ceramo paste before mounting
Available Sensor Types
type thread/length for mounting
wrench size [mm]
diameter [mm]
length [mm] weight [g] suitable monitor types
SiC-SV01 - - 17,5 38,5 140 (including 1m cable)PRO2, PRO3, PRO5, PRO8, PRO10.4, PRO11PRO15, PRO16, IF01, IF02, IF03
SiC001 G 1/4 / 14mm 19 21,7 49 (with plug: 84) 55 (+115g cable and plug)
SiC001-PG G 1/4 / 14mm 19 21,7 61 125 (including 1m cable)
SiCT001-PG G 1/4 / 14mm 17 20 57 85 (including 1m cable)
SiC003 G 3/4 / 11mm 32 37 52 (with plug: 87) 195 (+115g cable and plug)
SiC003-PG G 3/4 / 11mm 32 37 63 270 (including 1m cable)
SiC001 for UV-Compact1
G 1/4 / 14mm 19 21,7 49 55 (no additional cable) UV Compact MC
SiC001-PG-BNC G 1/4 / 14mm 19 21,7 61 180 (including 2m cable) UV Compact MCplus
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 42 -09/2006
Add -F for sensor with uvc filter.Side-Looking sensors are also available as digital sensors for digital operation system. Please order D-SLS-SiC003(-PG)/D-SLS-SiC004(-PG).
type thread/length for mounting
wrench size [mm]
diameter [mm]
length [mm] weight [g] suitable monitor types
SLS-SiC003 G 3/4 / 11mm 32 37 70 (with plug: 120) 190 (+115g cable and plug)PRO10.4 SLS, PRO15 SLS
SLS-SiC003-PG G 3/4 / 11mm 32 37 81 270 (including cable)
SLS-SiC004 - - 21,5 75 (with plug: 127) 85 (+115g cable and plug)
SLS-SiC004-PG - - 21,5 86 171 (including cable)
SLS-SiC003 SLS-SiC003-PG
SLS-SiC004 SLS-SiC004-PG
daylight blind (see diagramm below)
standard without uvc-filter limitation of spectral sensi-
tivity with uvc-filter on request
PG versions without plug connection between sensor and cable
integrated amplifier ±5V (DC supply necessary)extended flare angle
of side looking sensors
Measurement TechniqueUV-Sensors with Extended Flare Angle (Side-Looking Sensors)
for Monitoring of Relative UV-Intensitiesto be used for measurement in UV-units
Technical Specification
diode type: silicon carbide (SiC) 0,25mm² body: stainless steel 1.4305
spectral range: 210...400nm(with uvc-filter: 210...280nm)
flare angle: see diagram above
max. pressure: 10bar operating temperature: 0...40°C
connection: SLS-SiC003 / SLS-SiC004: connector M12, mounting cable with plug included, length: 2.90mSLS-SiC003-PG / SLS-SiC004-PG: cable length 1m (up to 2,90m on request)
supply voltage: ±5V
mounting restrictions: cover thread with teflon tape or ceramo paste before mounting
Available Sensor Types
Limitation of spectral sensitivity with uvc-filter available on request for use with medium pressure lamps.
Shielding connection must not be used as earth connection for safety reasons.
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 43 -09/2006
Technical Specification
diode type: silicon carbide (SiC) 0,0625mm² body: stainless steel 1.4305
spectral range: 210...400nm(with uvc-filter: 210...280nm)
flare angle: 26°
supply voltage UB:(current/voltage output)
9 24V stabilised, I ≤ 25mA(min. 12V for SiC007-U10)
linearity within the initial voltage range:
2%
temperature drift: 0,03 W/m²/K max. pressure: diode is sealed with quartz window-protection against humidity only
operating temperature: 0...40°C
dimensions: body-diameter: 20mm outer ring: 27mm
length: 86mm (SiC007)95mm (SiC007-PG, without cable)
weight: 120g (SiC007)155g (SiC007-PG with 1m cable)
connection: SiC007: connector M12 (Hirschmann cable plug ELST 5012), mounting cable with plug included, length: 2.90mSiC007-PG: cable length 1m
(other cable lengths on request)
SiC007-P-PG
adjusted versions with current or voltage output photodiode output versions also available PG versions without plug connection
between sensor and cable
suitable as plug-in sensor in measurement window MF001 daylight blind (see diagramm below) standard without uvc-filter limitation of spectral sensitivity with uvc-filter on request
SiC007-I-PGSiC007-Ux-PG SiC007-P SiC007-I
SiC007-Ux
Measurement TechniqueUV-Sensor SiC007 for MF001 with various output signals
for the measuring / monitoring of UV irradiation
* other values on request. Add -F for sensor with uvc filter. SiC007(-PG) is also available as digital sensor for digital operation system. Please order D-SiC007(-PG).
Available Sensor Types
sensor type signal output value adjusted value* min. load resistance Rmin
max. load resistance Rmax
SiC007-P photodiode output diode current - - -
SiC007-P-PG photodiode output diode current - - -
SiC007-I current output 4 - 20mA 20mA - 9V⇒330Ω / 24V⇒1kΩSiC007-I-PG current output 4 - 20mA 20mA - 9V⇒330Ω / 24V⇒1kΩSiC007-U2 voltage output 0 - 2V 2V 220Ω -
SiC007-U2-PG voltage output 0 - 2V 2V 220Ω -
SiC007-U3 voltage output 0 - 3V 3V 270Ω -
SiC007-U3-PG voltage output 0 - 3V 3V 270Ω -
SiC007-U10 voltage output 0 - 10V 10V 660Ω -
SiC007-U10-PG voltage output 0 - 10V 10V 660Ω -
Mounting RestrictionsAttention! The sensor is not suitable for directly use in water! The diode is sealed with quartz window-protection against humidity only. Please do not touch the surface of the sensor window.
We recommend the use of a sealing ring (O-ring, 20x1,5) in the outer ring.
Shielding connection must not be used as earth connection for safety reasons.
Do not connect or disconnect sensor-plug while supply voltage is switched on.
Limitation of spectral sensitivity with uvc-filter available on request for use with medium pressure lamps.
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 44 -09/2006
SiC021-x-PG
adjusted versions with current or voltage output
daylight blind (see diagramm below)
standard without uvc-filter limitation of spectral sensiti-
vity with uvc-filter on request PG versions without plug
connection between sensor and cable
SiC021-x
Technical Specification
diode type: silicon carbide (SiC) 0,0625mm² body: stainless steel 1.4305
spectral range: 210...400nm(with uvc-filter: 210...280nm)
flare angle: 26°
supply voltage UB: 9 24V stabilised, I ≤ 25mA(min. 12V for SiC021-U10)
linearity within the initial voltage range:
2%
temperature drift: 0,03 W/m²/K max. pressure: 10bar
operating temperature: 0...40°C
dimensions: thread: G1/4wrench size:19body-diameter: 22mm
length: 67mm (SiC021)78mm (SiC021-PG without cable)
weight: 77g (SiC021)105g (SiC021-PG with 1m cable)
connection: SiC021: connector M12 (Hirschmann cable plug ELST 5012), mounting cable with plug included, length: 2.90mSiC021-PG: cable length 1m(other cable lengths on request)
mounting restrictions: cover thread with teflon tape or ceramo paste before mounting
Measurement TechniqueUV-Sensor SiC021 with various output signals
for the measuring / monitoring of UV irradiation
* other values on requestAdd -F for sensor with uvc filter.SiC021-PG is also available as digital sensor for digital operation system. Please order D-SiC021(-PG).
Available Sensor Types
sensor type signal output value adjusted value* min. load resistance Rmin
max. load resistance Rmax
SiC021-I current output 4 - 20mA 20mA - 9V⇒330Ω / 24V⇒1kΩSiC021-I-PG current output 4 - 20mA 20mA - 9V⇒330Ω / 24V⇒1kΩSiC021-U2 voltage output 0 - 2V 2V 220Ω -
SiC021-U2-PG voltage output 0 - 2V 2V 220Ω -
SiC021-U3 voltage output 0 - 3V 3V 270Ω -
SiC021-U3-PG voltage output 0 - 3V 3V 270Ω -
SiC021-U10 voltage output 0 - 10V 10V 660Ω -
SiC021-U10-PG voltage output 0 - 10V 10V 660Ω -
Shielding connection must not be used as earth connection for safety reasons.Do not connect or disconnect sensor-plug while supply voltage is switched on.
Limitation of spectral sensitivity with uvc-filter available on request for use with medium pressure lamps.
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 45 -09/2006
* output value 0...10V on request
sensor type signal output value* suitable monitor types lamp types
SiCDVGW001-LP voltage output 0...2V
PRO10.4 (0-2V)
low pressure lamps
SiCDVGW001-MP voltage output 0...2V medium pressure lamps
SiCONORM001-LP voltage output 0...2V low pressure lamps
SiCONORM001-MP voltage output 0...2V medium pressure lamps
SiCDVGW002-LP current output 4...20mA PRO10.4, PRO11PI-I, PRO16I (-I) PRO16PI (-I)
low pressure lamps
SiCDVGW002-MP current output 4...20mA medium pressure lamps
SiCONORM002-LP current output 4...20mA low pressure lamps
SiCONORM002-MP current output 4...20mA medium pressure lamps
suitable as plug-in sensor in measurement window MF001
several supply voltages available
several output signals available
SiCDVGW SiCONORM
Measurement TechniqueUV-Sensors adapted to Special Regulations, Calibrated
according to German rule W294, resp. Austrian rule OENORM
Available Sensor Types
Technical Specification
uv-sensor: silicon carbide-(SiC) diode 0,25*0,25mm²
body: stainless steel 1.4307
dimensions: diameter of the body: 20mmdiameter of the outer ring: 27mmlength: 91mm insert length: 59mm
weight: 83g (without cable)
supply voltage UB: 9 15V stabilised linearity within the initial voltage range:
2%
operation current: SiCxxx001: <10mASiCxxx002: <25mA
calibration: according customers specification
temperature drift: 0,03 W/m²/K max. pressure: 10bar (only with MF001)
operating temperature: 0...40°C
connections: cable, length 2.90m, with plug M12 (Hirschmann cable plug ELWIST 5012)
Shielding connection must not be used as earth connection for safety reasons.
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 46 -09/2006
Measurement TechniqueUV-Sensors adapted to Special Regulations, Calibrated
according to German rule W294, resp. Austrian rule OENORM
Measurement window MF001 for DVGW-sensors and ONORM-sensors
The uv-measurement window according to rule W294, suitable for input of DVGW Sensor SICDVGW***, the uv-measurement window according to rule OENORM, suitable for input of ONORM Sensor SICONORM***,
watertight up to 10bar, consists of:
stainless steel (1.4305) body: length: 65mm / wrench size: 32 / thread: G1, 20mm longweight: 365g
hole for sensor input ∅ 20 x 60mm with cap nut M30 x 2 to connect the sensor
window made from quartz glass ∅ 24,5 x 5mm
MF001
desired value according to DVGW
actual value of the sensor
0
20
40
60
80
100
120
rela
tive
se
nsitiv
ity
[%]
240200
wavelength [nm]
medium pressure lamps: spectral sensitivity
300280 340220 260 3200
20
40
60
80
100
120
rela
tive
se
nsitiv
ity
[%]
240190
wavelength [nm]
low pressure lamps: spectral sensitivity
340290 390
Spectral Sensitivity for Low and Medium Pressure Lamps
Characteristics
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 47 -09/2006
Measurement TechniqueInterfaces IF01, IF02, IF03
for the Connection of Sensors and PLC
Functions:1. amplification of the signal output of fotodiode current sensors to voltage
output 0...5V (IF01) resp. current output 4...20mA (IF02) 2. adjustment of the sensor output signal according to the requirements
of the PLC (IF01, IF02) or of the digital operation system (IF03)3. 2 input/output channels4. fine adjustment of amplification by multi turn potentiometer
Technical Specification
mains voltage: 230V AC ± 10%, 50Hzmax. 2,5W115V-types available on request
protection level: IP00
input: up to 2 fotodiodes(adjustment necessary)
weight: 200g
dimensions (w/h/l): (97/48/43)mm mounting: DIN rail
For use in dry environment only!
Examples for wiring
type output IF01 2x 0...5V
(2x 0...2V on request)
IF02 2x 4...20mA
IF03 digital sensor signal
Available Interface Types
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 48 -09/2006
type switching threshold
operation current range
switch ondelay time
switch offdelay time
using with
SW 5.60 60 mA 60 - 200 mA ca. 0,5s ca. 0,5selectronic ballasts, monitoring fan, other control functions
SW 5.200 200 mA 200 - 800 mA ca. 0,5s ca. 0,5s
SW 5.800 800 mA 800 - 1000 mA ca. 0,5s ca. 0,5s
SW 10.60 60 mA 60 - 200 mA ca. 6s ca. 2sstarter and choke, other conventional circuit, electronic ballasts, other control functions
SW 10.200 200 mA 200 - 800 mA ca. 6s ca. 2s
SW 10.800 800 mA 800 - 1500 mA ca. 6s ca. 2s
SW 10.1500 1500 mA 1500 - 2500 mA ca. 6s ca. 2s
SW 10.2500 2500 mA 2500 - 4000 mA ca. 6s ca. 2s
SW 10SW 5
Measurement Technique Control Units SW5 and SW10 for Lamp Function Control
Control units for other applications are also available.
Technical Specification
mains voltage: 230V AC ± 10%
mains frequency: 45...65Hz
status indication: SW5:two potential free relay contacts (closed at correct operation), load: 50 - 500mA at 24V - 230V AC; 100 - 500mA at 24V - 60V DC
SW10:green and red LED indicate operating status,two potential free change over contacts,load: 50 - 500mA at 24V - 230V AC; 100 - 500mA at 24V - 60V DC
weight: SW5: 70gSW10: 200g
dimensions: (w/h/l) SW5: (97/27/43)mmSW10: (97/48/43)mm
wire gauge: 0,75...1,5mm²
mounting: DIN rail (DIN EN 50 022-35)
Available Lamp Control Types
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 49 -09/2006
Measurement TechniqueUV-Radiation Meter UVM-CP
for measurement of radiation intensity
The UV radiation meter is available for UV-A, UV-B, UV-C and UV/vis.
The gauge is equipped as standard with a cos-correction, which permits exact measurement at short distance.
The housing of the hand unit is made of polystyrene, the housing of the probe of aluminium.
Technical Specification
power supply: 9V (battery or accumulator) operating temperature: 15...40°C
status indication: LCD 3 digits, 9mm heigth protection level: IP00
measurement range: 2/20/200/2.000 mW/cm² measurement resolution: 1/10/100/1.000 µW/cm²
spectral range: UV-A: 310...420nmUV-B: 250...370nmUV-C: 200...300nmUV/vis: 370...440nm
reproduction: 3/30/300/3.000 µW/cm²
dimensions (w/h/l): (80/150/28)mm weight: 250g
For use in dry environment only!
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 50 -09/2006
UV-Lamps and AccessoriesQuartz Tubes
Immersion Tube Lamps
Our product range includes low pressure lamps and amalgam lamps of leading manufacturers.
Beside standard and special uv lamps we offer accessories like quartz tubes in different lengths and diameters and also special lamp sockets.
Furthermore we offer the production of uv immersion lamps for water disinfection and other applications.
quartz tubes
uv immersion tube lamps
ZED - ZIEGLER ELECTRONIC DEVICES GMBH
ZED - Ziegler Electronic Devices GmbH - Ilmenauer Strasse 9 - D 987O4 Oehrenstock/GermanyPhone: ++49 (O) 3677 2O 59 259 - Fax: ++49 (O) 3677 2O 59 26O - url: www.z-e-d.com - E-Mail: [email protected]
- 51 -09/2006
The socket is allowed up to 100W/1A.Wire must be solid or top coated stranded copper wire. Solder dipped is not recommended. Strip length: 1,1...1,25cm. Wire leads to be fully inserted into wiring port, ensuring uninsulated end of wire is not exposed. Use wire end ferrules with a length of 12mm. We recommend crimping pliers with square crimping e.g. KNIPEX KN975304.
Lamp Socket: 4pin plastic type
article code F4P
dimensions (l/w/h) (16/13/26,4)mm
wire gauge 0,5...0,8mm²
max. ambient temperature 60°C
max. current 1A
max. voltage 600V
Wire must be crimped with included crimp contact, strip length: 3,5mm. We recom-mend AMP PRO-CRIMPER II Hand Tool Assembly 90871-1 with Die Assembly 90871-2 for crimping contacts.
Lamp Socket: 4pin ceramic type
article code KF4P
dimensions (l/w/h) (17,5/14/23,3)mm
wire gauge 0,5...2mm²
max. ambient temperature 150°C
max. current 6A
max. voltage 600V
Wire must be crimped with included crimp contact, strip length: 3,5mm. We recom-mend AMP PRO-CRIMPER II Hand Tool Assembly 90871-1 with Die Assembly 90871-2 for crimping contacts.
Lamp Socket: 2G11 ceramic type
article code KF2G11
dimensions (l/w/h) (43/33/23)mm (without spring)
wire gauge 0,5...2mm²
max. ambient temperature 150°C
max. current 6A
max. voltage 600V
Connection by supplied mounting cable.
Lamp Socket: 2pin plastic type
article code F2P
dimensions (diam./h) (18/13)mm
max. ambient temperature 100°C
max. current 1,5A
max. voltage 600V
strip length: 3,5mmWe recommend AMP PRO-CRIMPER II Hand Tool Assembly 90871-1 with Die Assembly 90871-2 for crimping contacts.
Crimp Contacts for Lamp Sockets
article code single pins for KF4P or KF2G11
dimensions inner diameter: 2,26mm, length: 19,8mm
wire gauge 0,5...2mm²
max. ambient temperature 150°C
max. current 6A
max. voltage 600V
UV-Lamps and AccessoriesLamp Sockets for Low Pressure Lamps
Ceramic Lamp Sockets especially for Amalgam Lamps
Do not use the sockets in chemical aggressive and/or humid environment!