SOLiD DAS in iBwave
Product: iBwave Design
Version: 6.2.7 and higher
Published: 2013-02-13
iBWAVE SOLUTIONS INC.
© 2011 – All Rights Reserved
The information contained herein is the property of iBwave Solutions and is strictly confidential. Except as expressly authorized in writing by iBwave Solutions, the holder shall keep all information confidential, shall disclose it only to its employees with a need to know, and shall protect it, in whole or in part, from disclosure and dissemination to third parties with the same degree of care protect its own confidential information, but with no less than reasonable care. Except as expressly authorized in writing by iBwave Solutions, the holder is granted no rights to use the information herein. Information is subject to change without notice. iBwave Solutions reserves the right to make changes in design or components as progress in engineering and manufacturing may warrant.
Technical Note / Title
i
TABLE OF CONTENTS
OVERVIEW ................................................................................................................................................... 1
INTRODUCTION .......................................................................................................................................... 2
BUILDING AN ALLIANCE SYSTEM ........................................................................................................... 3
HEAD END SETUP .................................................................................................................................. 3
REMOTE UNIT SEUP ............................................................................................................................. 4
TITAN REMOTE UNITS SETUP .................................................................................................................. 6
MAIN REMOTE UNIT ............................................................................................................................... 6
ADD-ONS REMOTE UNIT ...................................................................................................................... 6
IBWAVE DESIGN EXAMPLE ...................................................................................................................... 9
EXPRESS PRODUCT LINE DESIGN ...................................................................................................... 9
ALLIANCE PRODUCT LINE DESIGN ................................................................................................... 10
TITAN PRODUCT LINE DESIGN .......................................................................................................... 11
PART LIST REFERENCE TABLE ............................................................................................................. 12
EXPRESS PART LIST ........................................................................................................................... 12
ALLIANCE PART LIST ........................................................................................................................... 15
TITAN PART LIST .................................................................................................................................. 17
CONTACTING CUSTOMER CARE ........................................................................................................... 19
OVERVIEW
Technical Note / SOLiD
1
OVERVIEW
This document explains how to use SOLiD DAS components in iBwave design. SOLiD provides several product lines; EXPRESS, ALLIANCE and TITAN. It applies to iBwave Design 5.2.7 and higher.
The following topics are covered:
INTRODUCTION TO SOLID DAS PRODUCT LINES
BUILDING AN ALLIANCE DAS SYSTEM
SAMPLE PROJECTS FOR THE DIFFERENT DAS SOLID PRODUCTS
PART LISTS FOR SOLID DAS SYSTEM
CONTACTING CUSTOMER CARE
SOLiD DAS solutions
Technical Note / Title
2
INTRODUCTION
SOLiD provides distributed antenna systems (DAS) solutions to deliver coverage for in-building design. It supports all public safety and cellular services including VHF/UHF radios.
SOLiD DAS solutions consists of
EXPRESS™ Single-Carrier DAS composed of:
• EXPRESS™ BIU (Base Station Interface Unit)
• EXPRESS™ ODU (Optical Distribution Unit)
• EXPRESS™ OEU (Optical Expansion Unit)
• EXPRESS™ MRU & ARU (Main Remote Unit & Add-On Remote Unit)
ALLIANCE™ Multi-Carrier DAS composed of:
• ALLIANCE™ BIU (Base-Station Interface Unit)
• ALLIANCE™ ODU (Optical Distribution Unit)
• ALLIANCE™ OEU (Optical Expansion Unit)
• ALLIANCE™ ROU (Remote Optical Unit)
TITAN™ 20W Remote Units composed of:
• TITAN 20W T_MRU
• TITAN 20W T_ARU
All the DAS solutions mentioned above are available in iBwave Design.
The following sections will shows how to use the ALLIANCE, EXPRESS and TITAN productsin an iBwave
design.
BUILDING AN ALLIANCE DAS SYSTEM
Technical Note / SOLiD
3
BUILDING AN ALLIANCE DAS SYSTEM
Build Head End:
1. Pull BIU_C from Filters. BIU_C includes MCDU, MCPU and MPSU cards.
2. Pull in required MDBUs from Filters and drop them into the open slots in the BIU.
Remember the following.
a. 4 available slots per BIU. If additional slots are needed, add a second BIU, combine
signals out of ODU ports using BIU_Combiner available in Splitter section and use same
ODUs.
b. Input ports are shown in the front in iBwave however these are test ports. All physical
connections are on the back of the BIU
3. Cover any blank slots in BIU_C with BIU_B from Misc.
Figure 1: BIU Chassis shown with 4 MDBU Cards.
4. Pull quantity required of ODU_C from Misc. (Maximum 4 per Sector)
5. Pull in the ODU fiber cards from FiberBDAHub, QTY 4 or 8 and drop into the ODU_C.
ODU_OM_4, or ODU_OM_4x2 from FiberBDAHub. If only 4-port card is used, include ODU_B
from Misc.
SOLiD DAS solutions
Technical Note / Title
4
Figure 2: ODU Chassis shown with a 4 port module and a blank module.
OEU Setup:
1. The OEU is setup similar to the BIU. It is modular with the OEU_C located in Misc. and the 4-
port hubs located in FiberBDAHub.
2. Connect fiber from ODU to OEU. Connect up to 8 remote units to OEU.
3. The OEU can only connect to optical port 4 and 8 on ODU 1 and 2 for a maximum of 4 OEUs per
sector.
Connecting Head End Components:
6. Using “0dB Jumper” under cable category, connect the DL_OUT and UL_OUT ports from MDBU
cards to respective MDBU UL and DL ports on top right corner of BIU_C. These jumpers
represent the backplane technology of the BIU and are required due to iBwave limitations. Do
not order these jumpers.
7. Connect ODU UL/DL ports on BIU_C to ODU_OM cards. These jumpers are provided with
ODU_C.
8. Signal Sources are connected on MDBU cards in software into the inputs shown in Figure 1.
These inputs are physically located on the back of the BIU, but due to software limitations of
iBwave, are shown on the MDBU cards front image.
Remote Unit Setup:
1. The remote unit (ROU_C) is located in iBwave under the Fiber BDA category. There are two
options, ROU_C_AC or ROU_C_DC. Select based on power requirements.
2. The ROU_C has a single strand fiber input, VHF/UHF SMA-type connectors, a single N-type
connector for Leg A SISO, along with a Leg B SMA connector for LTE MIMO configurations as
shown in Figure 3.
3. Connect ODU fiber port to ROU fiber port.
4. Connect VHF/UHF antennas.
5. Connect Mobile antennas.
6. The remote unit is modular. In order to populate the BOM correctly, include all RDU modules
required from the Misc. category.
7. Up to 3 modules per ROU_C may be used. VHF/UHF or LTE modules can be added in the
ROU_Add-On under Misc.
BUILDING AN ALLIANCE DAS SYSTEM
Technical Note / SOLiD
5
Figure 3: ROU with RDUs and Add-On Unit
A simple project design example for ALLIANCE and other DAS solution products are shown in the next
section.
SOLiD DAS solutions
Technical Note / Title
6
TITAN REMOTE UNIT SETUP
The TITAN remote units in iBwave are defined by three parts due to iBwave limitation
1. Main units T_MRU & T_ARU are located in iBwave under the FiberBDAHub & FiberBDA
category respectively.
2. The bottom sections (T_MRU_Bottom & T_ARU_Bottom) are located under splitter
category(Do not order these parts)
3. Band modules (850C_RDU25, 1900P_RDU25, 900l_RDU25, ..etc) are located under
Repeater category
Main Remote Unit Setup T_MRU
1. To set up a main remote unit follow the steps below:
a- Pull T_MRU unit from SOLiD’s FiberBDAHub category
b- Pull T_MRU_Bottom unit from SOLID’s Splitter category
c- Pull two Band Modules from SOLiD’s Repeater category such as T_RDU_850 &
T_RDU_1900
d- Connect ODU fiber port to T_MRU fiber port.
e- Connect the two output ports on the T_MRU unit Dummy_RDU_1 & Dummy_RDU_2 to
the input ports of the repeaters band modules HROU respectively using a 0 dB Jumper
f- Connect the output ports of the band modules repeaters (Dummy_Bottom) to the input
ports of the T_MRU_Bottom unit Dummy_RDU_1 and Dummy_RDU_2 using a 0 dB
Jumper
g- Connect the output port T_MRU unit Dummy_Bottom to the input port Dummy_T_MRU
using a 0 dB jumper
h- Connect ANT_1 output port from the T_MRU_Bottom to a Mobile antenna using a coax.
cable.
Add-On Remote Unit Setup T_ARU
2. The T_ARU unit connection are done as follows:
a- Pull T_ARU unit from SOLiD’s FiberBDA category
b- Pull T_ARU_Bottom unit from SOLID’s Splitter category
c- Pull two Band Modules from SOLiD’s Repeater category such as T_RDU_700LTE &
T_RDU_2100
d- The connections of the band modules repeaters with the T_ARU & T_ARU_Bottom units
are done the same way as that for the T_MRU & T_MRU_Bottom described in Step 1.
e- The output ports of T_ARU unit T_MRU_DL & T_MRU_UL are connected to the input
ports of main bottom unit T_MRU_Bottom T_ARU_1_DL & T_ARU_1_UL respectively
using 0 dB jumper
TITAN REMOTE UNIT SETUP
Technical Note / SOLiD
7
f- Connect ANT_1 output port from the T_ARU_Bottom to a Mobile antenna using a coax.
cable.
g- More T_ARU Units can be connected using the steps above with a maximum of 3 T_ARU
units for each T_MRU
Figure 4 and Figure 5 shows the connection of T_MRU & T_ARU respectively
Figure 4: T_MRU Connection with RDUs & T_MRU_Bottom unit
SOLiD DAS solutions
Technical Note / Title
8
Figure 5: T_ARU Connection with T_MRU unit
IBWAVE DESIGN EXAMPLE
Technical Note / SOLiD
9
IBWAVE DESIGN EXAMPLE
EXPRESS product design example is shown below:
Figure 6: EXPRESS Product DAS Solution
SOLiD DAS solutions
Technical Note / Title
10
ALLIANCE product design example is shown below:
Figure 7: ALLIANCE Product DAS Solution
IBWAVE DESIGN EXAMPLE
Technical Note / SOLiD
11
TITAN product design example is shown below:
Figure 8: TITAN Product DAS Solution
SOLiD DAS solutions
Technical Note / Title
12
PART LIST FOR SOLID DAS SOLUTIONS
EXPRESS part lists are shown in Table 1
PART LIST FOR SOLID DAS SOLUTIONS
Technical Note / SOLiD
13
Table 1: EXPRESS part list
SOLiD DAS solutions
Technical Note / Title
14
PART LIST FOR SOLID DAS SOLUTIONS
Technical Note / SOLiD
15
ALLIANCE part lists are shown in Table 2
SOLiD DAS solutions
Technical Note / Title
16
Table 2: ALLIANCE part list
Technical Note / SOLiD
17
TITAN part lists are shown in Table 3
Table 3: TITAN part list
SOLiD DAS solutions
Technical Note / Title
18
CONTACTING CUSTOMER CARE
Technical Note / SOLiD
19
CONTACTING CUSTOMER CARE
If you encounter any problems using iBwave Design, or if you have any questions, please send your inquiries to iBwave Customer Care:
Email: [email protected]
Phone: 1 514 397-0606, extension 610
SOLiD support & contact information
Email: [email protected]
Phone: 1 888-409-9997
You can also:
Log into the iBwave Customer Portal, and create a request in the My Cases section:
http://www.ibwave.com/language/en-US/MyiBwave.aspx
Check if your questions have been answered in the Knowledge Base section of the iBwave
Customer Portal
SOLiD DAS solutions
Technical Note / Title
2