Quality Reports 1 AEROCON BLOCK Frequency of on site Test : Compressive & Water absorption - 06 Nos per consignment Frequency of on site Test : Visual & dimension check - All consignment. Location of Sample : Quality Lab S N Name of Supplier Site test Third Party Soundness Colour Warpage Soundness Colour Warpage Acceptance Criteria 1 02-07-08 Hyderabad Industries 924 924 N/A OK 5.770 20.000 OK NA NA 3.11 24.56 2 15-12-09 Hyderabad Industries 918 1842 N/A OK 5.110 22.910 OK NA NA 3 06-01-09 Hyderabad Industries 918 2760 N/A OK 4.940 10.440 OK NA NA 4 19-01-09 Hyderabad Industries 918 3678 N/A OK 5.050 18.750 OK NA NA 5 28-01-09 Hyderabad Industries 918 4596 N/A OK 5.110 21.840 OK NA NA 6 31-01-09 Hyderabad Industries 918 5514 N/A OK 5.220 19.850 OK NA NA 7 01-02-09 Hyderabad Industries 918 6432 N/A OK 5.380 21.830 OK NA NA 8 04-02-09 Hyderabad Industries 918 7350 N/A OK 5.550 20.120 OK NA NA 9 04-02-09 Hyderabad Industries 918 8268 N/A OK 5.270 21.280 OK NA NA 10 13.08.10 Bhoomi agencies 450 8718 N/A OK 12.440 11.700 OK NA NA 0.022 Frequency of on site Test : Soundness, colour, Effloresence & Warpage - One for each stock 50,000 Nos Date of reciept of material at site Qty ( In Nos) Commulativ e Qty Compressive Strength Water Absorption Visual & dimension check Effloresenc e Compressive Strength Water Absorption Visual & dimension check Effloresenc e

description

read

Transcript of Solid Block

Aerocon BlockAEROCON BLOCKFrequency of on site Test : Soundness, colour, Effloresence & Warpage - One for each stock 50,000 Nos or lessFrequency of on site Test : Compressive & Water absorption - 06 Nos per consignmentFrequency of on site Test : Visual & dimension check - All consignment.Location of Sample : Quality LabS NDate of reciept of material at siteName of SupplierQty ( In Nos)Commulative QtySite testThird PartySoundnessColourCompressive StrengthWater AbsorptionVisual & dimension checkEffloresenceWarpageSoundnessColourCompressive StrengthWater AbsorptionVisual & dimension checkEffloresenceWarpageRemarksAcceptance Criteria102-07-08Hyderabad Industries924924N/AOK5.77020.000OKNANA3.1124.56215-12-09Hyderabad Industries9181842N/AOK5.11022.910OKNANA306-01-09Hyderabad Industries9182760N/AOK4.94010.440OKNANA419-01-09Hyderabad Industries9183678N/AOK5.05018.750OKNANA528-01-09Hyderabad Industries9184596N/AOK5.11021.840OKNANA631-01-09Hyderabad Industries9185514N/AOK5.22019.850OKNANA701-02-09Hyderabad Industries9186432N/AOK5.38021.830OKNANA804-02-09Hyderabad Industries9187350N/AOK5.55020.120OKNANA904-02-09Hyderabad Industries9188268N/AOK5.27021.280OKNANAUpto - 15.07.101013.08.10Bhoomi agencies4508718N/AOK12.44011.700OKNANA0.022

&RQuality Reports&C&PDeepak:3days resultDeepak:3days Result

Concrete blockCONCRETE BLOCKFrequency of on site Test : Soundness, colour, Effloresence & Warpage - One for each stock 50,000 Nos or lessFrequency of on site Test : Compressive & Water absorption - 06 Nos per consignmentFrequency of on site Test : Visual & dimension check - All consignment.Location of Sample : Quality LabS NDate of reciept of material at siteName of SupplierQty (In Nos)Commulative QtySite testThird PartySoundnessColourCompressive StrengthWater AbsorptionVisual & dimension checkEffloresenceWarpageSoundnessColourCompressive StrengthWater AbsorptionVisual & dimension checkEffloresenceWarpageRemarksAcceptance Criteria>=5N/mm2