Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change...
Transcript of Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change...
![Page 1: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/1.jpg)
Solar PV Inverters for Residential Installations
July 25, 2019DeSales University, Center Valley, PAEnergypath 2019
1
![Page 2: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/2.jpg)
IntroductionsMid‐Atlantic Renewable Energy AssociationA non‐profit organization, dedicated to educating and engaging the public and advocating for renewable energy production, energy efficiency and sustainable living.
2
www.themarea.orgBill Hennessy
Berks Solar, [email protected]
Vera Cole Energy and Sustainability Policy educator
[email protected], 215 219 7908
David SywenskyChilicon Power
![Page 3: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/3.jpg)
Grid-Tied Solar Electric—
3
![Page 4: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/4.jpg)
About Inverters… Three Main Functions
o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity from utility company)
o Shut down PV system in case of grid outage (safety requirement)o Maximize PV performance (make real time adjustments to
generate as much power as possible) Technology Options
o string (central), with MPPT for group (string) of moduleso Microinverters, with MPPT for individual moduleso DC optimizers w simplified inverter
![Page 5: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/5.jpg)
Solar Current-Voltage (I-V) Curve
5
![Page 6: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/6.jpg)
6
![Page 7: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/7.jpg)
Maximum Power Point Tracking “When directly coupling to a PV module, the
load determines the voltage at which the module will operate”
V / I = R Maximum Power Point Tracking (MPPT)
o Functionality built into invertero Programmable electronics that vary the
resistance to obtain the highest power
7
![Page 8: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/8.jpg)
Central (“String”) Inverter
8
One inverter for group of modules connected in electrically in series (“a string”).
Performs MPPT for entire string as a group.
Energy Sage, “String inverters vs. microinverters vs. power optimizers”
![Page 9: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/9.jpg)
“String” Design For a central inverter to work properly, voltage
needs to be within a certain window—not too high, not too low
A string is a group of solar modules connected together electrically in series
In series, voltages add (current stays same)
An array consists of one or more strings
9
![Page 10: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/10.jpg)
Modules in a String
+-- + -SeriesV = 105 VI = 7 A
Modules wired electrically in Series35 V + 35 V + 35 V = 105 V
Amperage (current) is unchanged
In series, voltage increases while current stays the same
35 V7 A
35 V7 A
35 V7 A
+
10
![Page 11: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/11.jpg)
Parallel Strings in an Array
+ --+
-
Strings wired electrically parallelModules wired in series, each string: 105 V and 7 A
Strings wired in parallel, array: 105 V and 14 A
Parallel V = 105 VI = 7 A + 7 A = 14 A
In parallel, current increases and voltage stays the same
35 V7 A
35 V7 A
35 V7 A
+
+ --+ 35 V7 A
35 V7 A
35 V7 A
+
-
11
![Page 12: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/12.jpg)
VoltageAdditional Considerations
Maximum Voltage – occurs at low temperature– too high, warranty void & possible inverter damage
Minimum Voltage– occurs at high temperature (oddly enough)– cell temperatures are higher than ambient– not a safety issue, but necessary for inverter performance and MPPT
12
![Page 13: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/13.jpg)
Sunny Boy 5000TL‐US Inverter
53 pounds! (transformerless)
13
![Page 14: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/14.jpg)
Microinverters
14
One microinverter per module. (In some cases per two modules.)
Performs MPPT for individual modules.
Energy Sage, “String inverters vs. microinverters vs. power optimizers”
![Page 15: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/15.jpg)
Microinverter Design
Compatibility with selected moduleo Module power rating o Number of module cellso Voltage operating range
Example manufacturers—o Chilicon Powero Enphase
15
![Page 16: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/16.jpg)
Chilicon 720 microinverter
16
![Page 17: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/17.jpg)
Microinverter Cabling
17
Branch Cable – connects a microinverter to the trunk cable
Trunk Cable – connects microinverters to one another and the grid
![Page 18: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/18.jpg)
Chilicon CP-100 Gateway
18
On-Site Array Configuration Power line communication,
WiFi, Ethernet, and Zwave Auto-discovers and binds
microinverters Production and Consumption
Monitoring Automated Cloud Monitoring
Registration Home Energy Audit Capable
![Page 19: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/19.jpg)
Power Optimizers
19
One optimizer per module. Performs MPPT for individual module.
Simplifed Inverter does DC-to-AC for group of modules/optimizers.
Energy Sage, “String inverters vs. microinverters vs. power optimizers”
![Page 20: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/20.jpg)
Optimizer Design
o Modules compatible with optimizer (may be integrated)
o Optimizer compatible with simplified inverters (sometime proprietary)
Example manufacturers—o SolarEdgeo Tigo
20
![Page 21: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/21.jpg)
PV Game Changers in Recent Years
Much, much lower module priceso Easier to cost justify, sites can be less perfect
Increased solar module energy densitieso More electricity generation from same PV area (300W solar modules
common now)
Performance management for groups of modules (“strings”) and individual modules, rather than PV system as a wholeo More shade toleranceo Solar modules don’t need to matcho Solar modules can be in different planes, with different orientationo Existing PV systems more easily expanded
So, less than “ideal” sites may now make sense!
![Page 22: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/22.jpg)
Hardware BOS –Structural and Electrical Components
Modules
Inverter
Soft Costs –Install Labor
Soft Costs –PLI, Land Acquisition, Sales Tax, Overhead and Net Profit
U.S. Solar Photovoltaic System Cost Benchmark: Q1 2018 (NREL)
per
Wat
t
![Page 23: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/23.jpg)
PV “Rapid Shutdown”
New rule added in NEC 2014 Requires that PV systems be quickly
de-energized when the AC service disconnect is open
Can only be met through module-level control—this means microinverters or optimizers, not string inverters
23
![Page 24: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/24.jpg)
civicsolar.com/article/nec-2017-module-level-rapid-shutdown
24
![Page 25: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/25.jpg)
String ("central") inverter Microinverter DC Power Optimizer & Simplified Inverter
Descriptio
n
One inverter to support many modules. Performance is managed for individual groups of modules ("string") or entire array.
Individual inverter is connected to each solar module, or factory installed (AC module). Performance is managed for each solar module independently.
Individual DC Optimizer is connected to each solar module, or factory installed. Performance is managed for each solar module independently. Separate simplified inverter does DC-to-AC conversion for group of DC Optimizers.
Locatio
n
Inverter is installed in vicinty of array, near service panel.
Inverters are installed with modules (more exposed to elements).
DC Optimizers are installed with modules (more exposed to elements). Simplified inverter located in more protected area.
Ope
ratio
n Solar modules must be closely matched, with same solar exposure and little or no shading. Any shading will affect performance of entire group.
Solar modules don’t have to match or be in same plane or direction. Shading in one part of array, does not affect other areas.
Solar modules don’t have to match or be in same plane or direction. Shading in one part of array, does not affect other areas.
Expa
nsion
Generally not suited for adding more modules later.
Can expand system, with few limitations.
Can expand system, within inverter specification.
Mon
itoring
Optional Necessary Necessary
Other Special feature like SMA’s Secure Power Supply provides some electricity during power outages.
Can make meeting electrical code requirements easier, depending on version enforced locally.
Can make meeting electrical code requirements easier, depending on version enforced locally.
![Page 26: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/26.jpg)
26
![Page 27: Solar PV Inverters for Residential Installations...About Inverters… Three Main Functions o Change the DC electricity (coming from solar) to AC electricity (to be same as electricity](https://reader035.fdocuments.us/reader035/viewer/2022081407/5f247e859128fe3e6168024e/html5/thumbnails/27.jpg)
Thank you!Mid‐Atlantic Renewable Energy AssociationA non‐profit organization, dedicated to educating and engaging the public and advocating for renewable energy production, energy efficiency and sustainable living.
27
www.themarea.orgBill Hennessy
Berks Solar, [email protected]
Vera Cole Energy and Sustainability Policy educator
[email protected], 215 219 7908
David SywenskyChilicon Power