Solar Pumping Inverter
Operation Manual
Designed & Manufact ured by
solar pumping inverter
Preface
Thank you very much for using SGY series of solar pumping inverter produced by FGS Energie Alternative.
P lease m ak e su re to read thi s manu al car ef ul ly b ef o re i nstallation and use in order to give full play to the
performance of this p ro duct and en su re the safety of user and eq uipment.
Please keep this manual in o rd er to subsequently facilitate the routine inspection and maintenance, an d find o ut the
cause of abnormity treatment countermea sure.
If there are an y questions or sp ecific requirement d uring u sing, p lease contact the d istrib utors of o ur company or
d i rectly kee p in tou ch w ith th e tech no log y service center of our compan y.
The manu al w ill be su bject to change witho ut an y further notification.
solar pumping inverter
Contents
S afety In stru cti on
Chapter 1 System Intr oduction
1.1 Introduction of Solar Pum ping sys tem ................................................................................3
1.2 Inverter Features .............................................................................................................. ... .. 4
1.3 Inverter Speci fi cati on .. .. ... .. ... ..... ......................... ..... ... .. ... .. ... .. ... .. ... ..... ......................... ..... ..4
Chapter 2 I nstal lation and Wiring
2.1 Purchasing Inspection ........................................................................................................... 6
2. 2 Shape ............. ..... ... .. ... .. ... .. ... .. ... ..... ......................... ..... ... .. ... .. ... .. ... .. ... ..... ......................... ..... ..6
2. 3 Output Wiring ......... ... ...................................... .. ............... .......................................................7
2.4 Outer plug instruction ............................................................................................................. 9
2.5 Sensor ....................................................................................................................................... 9
Chapter 3Operation Control
3.1 Panel Layout and Instruction ................................................................................................ 12
3.2 Operation Method of Panel .................................................................................................... 12
3. 3 Function Parameter Desc ription .......................................................................................... 13
Chapter 4 Installation Instruction ............................................................................................................. 17
Chapter 5 Storage and Warranty .............................................................................................................. 23
solar pumping inverter
1
S afety In stru cti on
To ensure safety operation of solar pumping inve rter, it mus t c hoose the right way of transportation,installation,opera tion and maintenan ce. Before opera tions, be aware of the safety notices as below:
Warn ing: Misuse willresult in f ire, s erious injury to pers on or even death.
Caution: misuse will cause low or middle-grad e injury to person or equipmen t damage.
Prom pt: P oi nt out s ome usefulinformation.
Purc hase Inspection
CautionI f the inverter is dam ag ed or m issi ng part s, it willnot be allowed to i ns tall, ot herw is e m ay hav e ac cidents.
Installation
Caution
1. To ensure good convection cooling effect, the inverter must be installed vert ical ly.
2. Install it in the indoo r condition which is possessed of ven tilation opening or ven tilating device. It is
forbidden to install where exp oses directly to the sunlight.
3. Do not let the drilling remai ns fall into the inve rter cooling fins or fans during installation in c ase the
dissipation is effected.
Connection
Caution
1. Each wire connected to the inve rter must be wrapped with electrical tape for safety.2 . Con nection jo b must be carried out by qualified electricalprof es sionals, or else it willcaus e electrocution
or fire.3 . Please confirm t hat input pow er has already been cut off, or else it willcause electr ic shock or fire.4 . Eart h terminalmus t be reliab ly ground, or else the inve rter shell willhave a dan g er of being electrified.5 . The type selection of PV array, motor load and inverter must be reasonable , or else the equipment will be
damag e d.
solar pumping inverter
2
Running
Caution
1. Please us e the fasten terminalof the specified torque, or else it will cause fire.2. Do not connect the output term inalof the inverter to the capacit or and phase -advanced LC/RC noise filter.
It is recommend touse the output reactor when the distance betwee n the inve rter andthemotor load
more than exceed s 100 m.
Caution
1. Adjust partial control parameters according to the steps indicated by the manual before its first runn ing.
Do not change the control param e ters of the inve rter randomly, or else it will cause dam age to the
equipment.
2. Because the heat sink's t em perature is high during running, do not touc h it f or a long time, or else it will
cause burn.
3. In the condition of altitude over 1000m, the inve rt er should be dera ted f or use, that is, out put curren t will
be de-ra ted by 10% at every 1500 m increment of height.
Warning
1. Maintenan ce and inspection must be performed by the qualified electric professionals.
2. Do not dismantle the inverter during electrifying. Con duct maintenance and inspection at least 5 minutes
after the power off.
3. It is absolutely forbidden to recons truct the inve rter by oneself, or el se it will cause personnel injury or
equipment damage.
4. Treat the inverter as industrial waste when pro cessing the abandoned inverter. It is possible that the
electrolytic capacitor will explode during incineration and that part of componen ts will pr oduce toxic and
harmful gas.
solar pumping inverter
3
Chapter 1 Sys t em Introduction
1.1 Introduction of Solar P um ping System
Solar pump ing system becomes more and more popular, it can be appli ed to dai ly use (underground water),
agriculture irri gation, forestry irrigation, desert control, pasture animal husban dry, water supply for islands,
wastewater treatment engineering, and so on. In recent yea rs, with thepromotion of theutilization of new
ener gy resources, solar pumpi ng systems are more an d more us ed in municipal engineering, city center
square s, parks, tourist sites, resorts and hotels, the landscapes and fountain systems intheresidential
area s.
This system is composed of solar array, 3 phase AC pum p and s olar pumping inverter. B ased on the design
philosophy that it is better to store water than elec tricity, there is no energ y storing device such as s tore
battery in the system.
Structure of solar pumping system
The s olar arra y,an aggre gation of many s olar modules c onnected in series and parallel, absorb s sunlight
radi ation and converts it into electrical energy, providing dyn amical wat er for the whole sys tem. The
pumping inver ter controls and adjus ts the system operation and converts the DC produced by s olar array
into AC to drive the pump, and adjust the output frequen cy in real-time according to the variation of sunlight
intensity to realize the maximum pow er point tracking (MPPT). The pump, drive by 3-pha se AC motor, can
draw wat er f rom the deep well s or river s and lakes to pour i nt o the st orage tank or reserv oi r, or di rect ly
c onnect to the irrigation sys tem, fountain sys tem, et c. According to the ac tual syst em demand and
installation conditions, different types of pump such as centri fugal pump, axial flowpump, mixed-flow pump
or deep-we llpump can be used.
solar pumping inverter
4
1 .2 In v er ter F eatu r es
· O ne power key to turn O N/O FF.
·Com patible with 3-phase induction motor.
·Adopting the proposed dyn amic VI maximum power point tracking (MPPT) control method; Fas t response
speed and stable operation; Better than the conventional methods whi ch may lead to the problems
including poor tracking perfor mance, unstable opera tion or even damaging water hammer effects when the
irrad iation on the array change rapidly.
·Digital control with full aut omatic running, dat a storage and complete protective functions (short-circuit,
overload , ove r voltage, under voltage, over heat, reverse polar ity, thunder, over flow and dry runn ing).
·The main circuit adopts intelligent pow er module (IPM), with high reliability and high efficiency 98%.
· Uni qu e des ign of cold roll ing steels he llwith good co oling and shielding, LCD display (43*2 9mm) and keys,
easy opera tion, good view through LCD when setting parameter, feel comfortable.
·Protection degr ee IP55, working temperature: -10℃to 50℃
· Solar pump inve rter can c onnects to c ity pow er when there is no sunshine to k eep system pumping water
(this function is optional).
·Solar pump inverter can be built-in GPRS receivin g module(optiona l).You can operate t his inverter
remotely throug h your PC or mobile phon e with our provided website, user name and password.
· Low voltage drive device is our pat ent right produ ct,can be us ed in small solar pumping syst em to save
the quantity of solar panels.
·Soft start and variable-fre quency function.
1.3 I nverter specification
Model Description
S GY 750 L S GY 3700 H
L ….Low Voltage H….High Voltage
750 w …..Power 3700 w …..Power
Y……….Pump Y …………Pump
G………PV array G………...PV array
S …SETEC power S…….SETEC power
Remar k: “ L” means low voltage : 3 phase 220V;
“ H” m eans high voltage:3 phase 380V.
Caut ion: Do not tear of f the prod u ct's name pl at e label.
solar pumping inverter
5
Solar pumping system specification
Solar Pump Invert erSolar
ArrayAC Pump
Model
Rated
Pow er
(KW)
Input
Voltage
Range(VDC)
MPPT
Voltage( V)
Rated
output
Voltage
(VA C)
Output
Fr e que ncy
(Hz)
DC
pow er
(K W)
Rated
Power
(KW)
Input
Voltage
(VAC)
SG Y75 0L 0.75 280-4 30 2 80 -350 3PH 220 0- 50/60 0.8 25 0.55 3PH 220
SG Y7 50H 0.75 450- 750 4 80 -600 3PH 380 0- 50/60 0.8 25 0.55 3PH 380
SG Y1 500L 1.5 28 0-4 30 280 -350 3PH 220 0- 50/60 1.65 1.1 3PH 220
SG Y15 00H 1.5 450- 750 480 -600 3PH 380 0- 50/60 1.65 1.1 3PH 380
SG Y2 200L 2.2 28 0-4 30 280 -350 3PH 220 0- 50/60 2.25 1.5 3PH 220
SG Y22 00H 2.2 450- 750 480 -600 3PH 380 0- 50/60 2.25 1.5 3PH 380
SG Y3 700L 3.7 28 0-4 30 280 -350 3PH 220 0- 50/60 4.5 3 3PH 220
SG Y37 00H 3.7 450- 750 4 80 -600 3PH 380 0- 50/60 4.5 3 3PH 380
SG Y5 500L 5.5 28 0-4 30 280 -350 3PH 220 0- 50/60 6 4 3PH 220
SG Y55 00H 5.5 450- 750 4 80 -600 3PH 380 0- 50/60 6 4 3PH 380
SG Y75 00H 7.5 450- 750 480 -600 3PH 380 0- 50/60 8.25 5.5 3PH 380
SG Y1 1KH 11 450- 750 4 80 -600 3PH 380 0- 50/60 11 .25 7.5 3PH 380
SG Y1 5KH 15 450- 750 4 80 -600 3PH 380 0- 50/60 16 .5 11 3PH 380
SG Y1 8KH 18 450- 750 4 80 -600 3PH 380 0- 50/60 22 .5 15 3PH 380
SG Y2 2KH 22 450- 750 4 80 -600 3PH 380 0- 50/60 27 .8 18 .5 3PH 380
SG Y3 0KH 30 450- 750 4 80 -600 3PH 380 0- 50/60 39 26 3PH 380
SG Y3 7KH 37 450- 750 4 80 -600 3PH 380 0- 50/60 45 30 3PH 380
SG Y4 5KH 45 450- 750 4 80 -600 3PH 380 0- 50/60 56 37 3PH 380
SG Y5 5KH 55 450- 750 4 80 -600 3PH 380 0- 50/60 68 45 3PH 380
SG Y7 5KH 75 450- 750 4 80 -600 3PH 380 0- 50/60 98 65 3PH 380
Cau tion: Please be sure to select the appropriate model accor ding to the P V arr ay and m otor load.
Caution: High-power machine model uses multiple-c hannelDC inpu t structure . T he input po w er in
the a bove table i nd icates totalm ul ti-channelinput pow er.
solar pumping inverter
6
Ch apter 2 Installation and w iring
2.1 Purchase Inspection
Our company has rigid quality as surance system in product manufac turing, pack age, etc . If any abnormity
is found, pl ease immediately c ontact the distribut ors of our company or directly keep in touch with the
t ec hnology s ervi ce c enter of our company.We will solve t he pr oblems for you i mmediately.Onceyou get
the product, pl ease confirm the following items:
I ns pec tion it em I ns pec tion method
Consistency with ordered pr oduct Inspect the product’s nameplate label
Damag e or exfoliation phen omenon Inspect whole appearance
Completeness of m ain machi ne and accessories Check carefully according to the product list
Looseness of fastening parts suc h as screw If necessary, inspect with screwdriver
2.2 Shape
5.5KW,7.5KW, 11KW, 15KW 0.75W,1.5KW,2.2KW,3.7KW
solar pumping inverter
7
2.3 Output w iring
18KW,22KW, 30KW
solar pumping inverter
8
Warning: In order to ensure system work normally and properly, please use recommended wi res with
different size as below.
Model No. Solar panel wire Groun d wire Motor wire Sensor wire
SGY750L 2.5mm2 2.5 mm2 2.5 mm2 0. 5-1. 0 mm2
SGY1500L 2. 5 mm2 2.5 mm2 2.5 mm2 0. 5-1. 0 mm2
SGY2200L 2. 5 mm2 2.5 mm2 2.5 mm2 0. 5-1. 0 mm2
SGY3700L 4mm 2 4mm 2 4mm 2 0. 5-1. 0 mm2
SGY3700H4mm 2
Rated voltage 750V
4mm 2 4mm 2 0. 5-1. 0 mm2
SGY5500H4mm 2
Rated voltage 750V
4mm 2 4mm 2 0. 5-1. 0 mm2
SGY7500H4mm 2
Rated voltage 750V
4mm 2 4mm 2 0. 5-1. 0 mm2
SGY11KH8mm 2
Rated voltage 750V
4mm 2 6mm 2 0. 5-1. 0 mm2
SGY15KH10 mm2
Rated voltage 750V
4mm 2 6mm 2 0. 5-1. 0 mm2
SGY18KH12 mm2
Rated voltage 750V
4mm 2 10 mm2 0. 5-1. 0 mm2
SGY22KH15 mm2
Rated voltage 750V
4mm 2 12 mm2 0. 5-1. 0 mm2
SGY30KH20 mm2
Rated voltage 750V
4mm 2 15 mm2 0. 5-1. 0 mm2
solar pumping inverter
9
2.4 Outer plug instru ction:
Socket Wire description Connection descriptionRed wire
single strand
connected positive pole of PV
array
Black wire
single strand
connected negative pole of PV
array
4
Core
wire
Red wire Aphase
Gree n wire Bphase
Blue wire Cphase
Yellow-gree n wire Ground wire
9
Core
wire
(ne tw o rk
cable
Blue wire Tank sensorhigh
Red wire Tank sensormiddle
White- blue wire
White-re d wire
Tank sensorground wire
G reen wire Well sensor hi gh
Brown wire Well sensor middle
White- green wire
White- brown wire
Well sensor groun d wire
2.5 S ensor ( Opti onal)
Our solar pumping inverter has sensor interf ac e and along with s ensor contactor with short lead ne twork
cabl e. Then you can use anti-interface network cable to prolong this line. This network cable is a sensor for
tank full and well dry. I t has 9 core wires: 4 wires used as tank sensor; 4 wires used as well sensor. 1wire
connected with ground. Sensor cable as below:
How does sensor work?
A) 4 wires us ed as well sensor. Bl ue, red, w hite-blue and w hite-red. Each wire ’s terminal should be
removed the cover, leave core outside. Blue used as high sensor. Red us ed as middle sensor. White-blue
and white-red together us ed as lowest sensor.
solar pumping inverter
10
Remar k: You can set the sensor place as you like.
B) 4 wires us ed as well sensor. Green, bro wn, white-green and white-brow n. Each wire ’s terminal
should be removed the cover, leave core outside. When c ore touch the wat er, it is s ensor. Green used as
high sens or. B rown used as middle sensor. White-green and white-brown together used as lowest sensor.
Remark: The sensor part is optional according to your applicatio n. But if you want to use t hesensor function, it must set as below: (this part is in sensor setting)
If wa ter level reaches the lowest sensor,
means water is very little, inve rter starts to
drive pump to pump wat er.
If water level reaches middle sensor, means
tank water is muc h. Inver ter continues to drive
pump topump water.
If water level reaches high sens or, means tank
is full . Inverter wi lldri ve pump to s top pum pi ng
water.
This middle sensor should be fixed a bit far above pump ’s
water incom ing hole. If water level meets this middle
sens or, means well water is littl e, inve rter should stop to
drive pum p, otherwise pump will damage without wat er.
This lowest sens or should be under pump ’s water
incoming hole. Y ou can make it long or short as you like.
T hi s hi gh s ens or shoul d be fixed abov e m iddl e sens or, you
can fix it at any place as you like, but it s hould be under
water. When water cover s three sensors, inverter starts to
drive pump to pump wat er.
solar pumping inverter
11
1. Tank sensor
When it just used Tank sensor, Tank s ensor should be Yes, and well sensor be No.
2. Well sensor
Only Well sensor, Tank sensor sets No and well sensor beYes.
3. Tanksensor & Well sensor
When Tank sensor & Well s ensor are used, both set Yes.Instead, when sensor function is no need, please set both are NO ,otherwiseitcannotwork.
solar pumping inverter
12
Ch apter 3 Operation Control
3.1 Panel La yout and Instruction
Solar pump ing inverter is LCD displayed, s ee as below diagram, including 4 LED lights, 1 LCD panel and4
keys and ON/OFF pow er key. Simple operation, easy understanding.
3.2 Operatio n M eth od of P an el
S etting of allp aram ete rs , w ork state, al arms etc. are expl ai ned as b el ow.
Key Explanation: there are 4 keys: “ESC’’, “UP ’’ , “ DOWN’’, “ENTER ’’. Change parameter by pressing
“ ENTER ’’key. Press “UP’’, “DOWN ’’ to change value, then press “ENTER ’’ key to save . “ESC’’means
return s.
ON/OFF: Press this Key to turn ON/OFF.
LCD d is play
4LED lights: POWER, AUT O,MANUAL, ALARM
(left to right)
4 keys: ESC( ),UP( ),DOWN( ),ENTER
( )(lefttoright)
PowerKey
solarpumpinginverter
13
3.3FunctionParameterDescription
1.PowerOn,firstInterface:
2.Press“DOWN”keytothisinterface:
3.Press“DOWN”keytothisinterface:
4.Press“DOWN”keythisinterface:
5.Press“DOWN”keythisinterface:
Displaycompanyname,productnameandmodel.Press“DOWN”keyto
secondinterface.
DCVoltage:500 V
DCInputCurrent:0.8 A
DisplaycurrentDCinputvoltage,DCinputcurrent.
Displaysavedpowervalue,reducedCO 2 value.
Displaytanksensorstateandwell sensorstate,youcanchoose“NO”or“OK”by
press“UP”and“DOWN”keys,ifyouchoose“OK”,thetanksensorandwell sensor
canwork, default “NO”. Whenyouset well sensor“OK”, but youdon’t put well
sensorintowater.Theninverterdoesnothasoutput.
SETECPowerPumpInverter
SGY3700H
SavedPower:2.44 KWh
ReducedCO 2:1.66 Kg
TanksensorNO
WellsensorNO
OutputFrequency:21.6 Hz
OutputPower:395 VA
Displaycurrentoutputfrequencyandoutputpower.
solarpumpinginverter
14
6.Press“DOWN”keythisinterface:
Nomatterwhichpanel youareoperatingnow,press“ENTER”keytoenterinto“InputPassword”(referto
belowinterface6).
7.Password:
Press“ENTER”key4times,enterintosystemmenu,thereare9contents,eachinterfaceshows3contents.
8.Systemmenufirstinterface:
9.Press“DOWN”keytoenterintosystemmenusecondinterface:
Press“ESC”2timestoSystemmenuinterfaces,press“UP”or“DOWN”toselectyourwantedcontent,thenpress“ENTER”
keytoenterintocorrespondingparametersetting.
Displayinverter inner temperature, workingstateandhowmanyalarms
currently.
Temp.:30.2℃
Status:AutomaticNow0Alarms
Check>>
UnderSystemMenu, press“UP’’, “DOWN’’ toselect yourwantedcontent,
press“ENTER’’keytoenterintocorrespondingmenu.
Showingpassword, default 4zero. For user, noneedtochange
password.InputPassword
0000
==SystemMenu==4.Reset5.Resetpassword6.Version
Under SystemMenu, press“UP’’, “DOWN’’ toselect your wanted
content,press“ENTER’’keytoenterintocorrespondingmenu.
==SystemMenu==1.Workmode2.ON/OFF3.Parameters
solarpumpinginverter
15
10.Selectworkmode
11.SelectpowerOn/Offtocontrol theoutputofinverter.Whenselect“OFF”,nopowerforpump,pumpdoesnotwork.
Plsnotedthatthereare2waystocontrol theinverter.
1. YoucanselectON/OFFfromthesystemmenu.
2. PressON/OFFKeyinthefrontcover.
Selectparametersandsettingthem,thereare4parametersshowsintwointerfaces.
12.Parameterssettingfirstinterface:
13.Parameterssettingsecondinterface:
Press“ESC”keyreturntoParameters,press“UP”and“DOWN”keystoselectyourwantedcontent,press“ENTER”keyto
enteryourwantedcontentandsettingyourneededvalued.
14.SettingPVarrayopencircuitvoltage:
Settingsystemwork mode, press “UP’’, “DOWN’’ toselect mode, press
“ENTER’’ keytoconfirmmodification. Our default isautomatic. Whenset
automatic, invertercanpoweronwhenthereisenoughsunshine, it canpower
offwhenthereisnosunshine. Youdon’tneedtopoweronandpoweroffevery
day.Whenyousetmanual,youneedtopoweronandpoweroffbyhand.
Power On/Off setting, press “UP’’, “DOWN’’ toselect mode, press
“ENTER’’ toconfirmmodification. If youwant topower off thisinverter,
youcanset“OFF”andconfirm.Theninverterwill poweroff.
Parametersetting,press“UP’’,“DOWN’’ toselectyourwantedcontent,press
“ENTER’’keytoenterintocorrespondingmenu.
Parametersetting, press“UP’’, “DOWN’’ toselect yourwantedcontent,
press“ENTER’’keytoenterintocorrespondingmenu.
PVarray opencircuit voltagesetting, press “UP’’, “DOWN’’ to
increaseor decreasevoltagevalue, press “ENTER’’ toconfirm
modification. Pleaseset thisvoltageaccordingtoyoursolarpanel’s
total voc,notexceedourmaxratedvoltage750V.
Workmode1.Manual2.Automatic
ON/OFF1.ON2.OFF
Parameters1.PVArrayOCV2.MaxPVArrayV3.HighestFreq
Parameters4.LowestFreq5.Sensor
PVArrayOCV
630V
solarpumpinginverter
16
15.SettingMaximumpowerpointtracking(MPPT)voltage:
16.HighestFrequencySetting:
17.LowestFrequencySetting:
18.SensorSetting:
19.ResetSetting:
20.PasswordReviseSetting:
MPPTvoltagesetting, press “UP’’, “DOWN’’ toincreaseor decrease
voltagevalue,press“ENTER’’ toconfirmmodification.
Our inverter’sMPPTvoltageis480V-600VDC, pleaseset thisvoltage
accordingtoyoursolarpanel’stotal vmp.
Highest frequencysetting, press“UP’’, “DOWN’’ toincreaseor decrease
frequencyvalue,press“ENTER’’ toconfirmmodification.
Youcansethighest frequencyasyoulike.Forexample, ifyousethighest
frequencyis30HZ, inverter’shighest frequencyis30HZ, thought good
sunshine,thisfrequencyisstill 30HZ,can’tgoesupto50HZ.
Sensor setting, press“UP’’, “DOWN’’ toselect “OK” or “NO”, press
“ENTER’’ toconfirmmodification. If youset “OK”, meanssensor is
available. Tanksensor candetect tankisfull or not, well sensor can
detect well isdryor not. Whentankisfull or well isdry, inverter stop
output,pumpdoesnotrun.Ifyouset“NO”,meanssensorisunavailable.
Reset setting, press“UP’’, “DOWN’’ toselect, press“ENTER’’ to
confirmmodification.
MaxPVArrayV
540V
HighestFreq
50Hz
TankSensorNO
WellSensorNO
RESETCleardata?
Cancel OK
Passwordrevisedsetting, press“UP’’,“DOWN’’ toaddorminusvalueto
setyourwantedpassword,press“ENTER’’toconfirmmodification.
Normally,userdoesnotneedtousethissetting.
InputNew
0000
LowestFreq05HZ
ShutdownTime01Min
Youcanset lowest frequencyasyoulike. Belowthislowest frequency,
theinverterhasnooutput.Forexample,ifyousetlowestfrequency5HZ,
whenthecurrent frequencyis4HZandshutdowntimeis1min. Inverter
hasnooutput for1min. Inverter start again. If current frequencyisstill
4HZ,invertershutdownagain.1minlater,inverterstartsagain.
solarpumpinginverter
17
21.VersionInfo:
Caution: Accordingtoreal PVarray, thePVarrayopencircuit voltage(interface14) andMPPT
voltage(interface15)canbechangedaccordingtoreal PVarray.
Chapter4Installationinstruction
Inordertoletyouknowhowtomakeconfigurationofthewholesystem,nowweassume2projectsforyourreference.
Ⅰ.3.7kwsolarpumpsystemconfiguration
1:ACpump:2200W,3phase,380v,50Hz
2:Solarpumpinverter:3700WInputvoltage:450V-750V.
MPPTvoltage:480V-600V(Model:SGY3700H)
3:Solarpanel arraypower:total 3.3Kw,eachsolarpanel 220w,
vmp:35V,voc:39V,total 15pcs.
Pleasenotethat different solarpanel fromdifferent supplier, thoughthepowerissame, thevmpandvoc
will bedifferent, pleasechoosesuitablesolar panel accordingtoyour pumpandmatchingsolar pump
inverter.
Remark:solarpanel arraypowershouldbe1.5timesofpump’spower.
Solarpanel arrayconnectedwithsolarpumpinverterasbelow:
Version
REV2013.07.001
solarpumpinginverter
18
SGY3700Hsolar pumpinverter minimumDCinput voltageis450V, andmaximumDCinput voltageis
750V.MPPTvoltagerangeis480V-600V.
Let’sconfigurethesolarpanel (Successful configurationforthesolarpumpingsystemmustsatisfyatleast
threebasicrequirementsasbelow.)
TotalVmp:35V*15pcs=525VMeetMPPTvoltage(480V-600V)
TotalVoc:39V*15pcs=585VMeetinverter’sinputvoltage450V-750V
Totalpower:220w*15pcs=3300w
Accordingto525V(Vmp) and585V(Voc), wecanset Maximumpower point tracking(MPPT)(screen
shows”MaxPVArrayV”)voltageas525VandsetPVarrayopencircuitvoltage(screenshows“PVArray
OCV’’)as585V. Our inverter withLCDscreen, it iseasytooperateandset theseparametersthrough
screen.Youcanrefertobelowscreens(screen14andscreen15fromourusermanual).
Solar panel array’spositive and negativeshould be connectedwith solar pumpinverter’s positive andnegativeaccordingly.
All theinterfacecablesshould be securelyconnected avoid highvoltagerisk.
solarpumpinginverter
19
Ⅱ. 11KWsolarpumpsystemconfiguration
1:ACpump:9.2kw,3phase380v,50Hz.
2:Solarpumpinverter:11kwInputvoltage:450V-750V.
MPPTvoltage:480V-600V(Model:SGY11KH)
3:Solarpanel arraypower:total 14kw,eachsolarpanel 250w,
vmp:36V,voc:44V,total 56pcs.
Pleasenotethatdifferentsolarpanel fromdifferentsupplier,thoughthepowerthesame,thevmpandvoc
will bedifferent, pleasechoosethesuitablesolarpanel accordingtoyourpumpandmatchingsolarpump
inverter.
Remark:solarpanel arraypowershouldbe1.5timesofpump’spower.
Remark:5.5kw-15kwsolarpumpinverterhastwoinputpositiveinterfaceandtwoinputnegativeinterface.
Inordertosharehighvoltagefromsolarpanel array,normallyweuseuptwogroupspositiveandnegative.
Solarpanel arrayconnectedwithsolarpumpinverterasbelow:
solarpumpinginverter
20
14pcsof250wsolarpanelsshouldbeconnectedinseries.
Total Vmp:36V*14pcs=504V Meetinverter’ MPPTvoltage480V-600V
Total Voc:44V*14pcs=616V Meetinverter’sinputvoltage450V-750V
Total power:250w*56pcs=14000w
Accordingto504V(Vmp) and616V(Voc), wecanset Maximumpower point tracking(MPPT)(screen
shows”MaxPVArrayV”)voltageas504VandsetPVarrayopencircuitvoltage(screenshows“PVArray
OCV’’)as616V. Our inverter withLCDscreen, it iseasytooperateandset theseparametersthrough
screen.Youcanrefertobelowscreens(screen14andscreen15fromourusermanual).
Solar panel array’spositive and negativeshould be connectedwith solar pumpinverter’s positive andnegativeaccordingly.
All theinterfacecablesshould be securelyconnected avoid highvoltagerisk.
solarpumpinginverter
21
III.Howtoconnectthemotor’swires:
Note:Inverter’soutput3phase(A,B,C)areconnectedwithACpump’s3phase(A,B,C).
Youcantrytoconnectany3wiresandtwistedtogether. Then,poweroninverterandcheckoutputwater
flow.Ifwaterflowisnotverygood,pleasetrytoexchangeany2wirestotwisttocheckwhichconnection
waterflowisthebiggest.Thenmeanthese2wiresiscorrectphaseconnection.Thentwistthewirestightly
andwrapitwell.
solarpumpinginverter
22
IV.Motor’swire:
VI.Accessory:
solarpumpinginverter
23
Chapter5Storage&Warranty
5.1Storage
Ifthestorageisnotusedtemporarilyorstoredforlongtimeafterpurchasing,thefollowingnoticeshouldbe
paidattentionto.
1.Avoidplacingtheinverterinhightemperatureorhumidplaceorwherethereisvibrationandmetal dust,
andexcellentventilationshouldbeensured.
2. Insidefilter capacitor performanceof theinverter will declinefor long–timedisuse. It isnecessaryto
energizeonetimeevery2yearstorestoretheperformanceofthefiltercapacitorandinspect theinverter
functionat thesametime. It isnecessarytoincreasethevoltagethroughaDCpower supplyduring
energizingwithpower-ontimenotlessthan5hours.
5.2Warranty
Thewarrantyofthisinverteristwoyears.Whenanyfaultordamageoccursontheproduct,withinthe
warrantyperiod,ourcompanywill providefreemaintenance.Afterthewarrantytime,wecanprovide
lifetimepaidwarrantyservice.
5.3ExtendedWarranty
Wewill extend1yearwarranty,ifyouprovidebelowinformationtous.
Providebelowinformationwheninquiry,wewillmakegoodconfigurationforyou.
1 Pump Power,Voltage,Phase
2 SolarPanel Eachpanel power,vocvoltage,vmpvoltage
Providebelowphotosandinformationafterinstallation.
1 Pump Photosshowpump,pumpspecification,pumpandinverterconnection
2 Inverter Photosshowinverterinstallationenvironment,inverterconnectionandswitch,
LCDscreenparametersetting.
3 SolarPanel Photosshowsolarpanel andinverterconnection,solarpanel specification,solar
panel arrayandquantity.
Prompt:Warrantyonlycoversthebodyoftheinverter
solarpumpinginverter
24
WarrantyAgreement
1.Thewarrantyofthisinverteristwoyears.Whenanyfaultordamageoccursontheproduct,withinthe
warrantyperiod,ourcompanywill providefreemaintenance.Afterthewarrantytime,wecanprovide
lifetimepaidwarrantyservice.
2.Thewarrantytimestartsfromthedatewhentheproductisleavingthefactory,andthemachineframe
codeistheonlyprooftodeterminethewarrantyperiod.
3.Certainmaintenancechargeshouldbeconsideredduringwarrantyperiodifthefaultiscausedbythe
followingreason:
·Faultcausedbyoperatingagainstthemanual orsurpassthestandardspecification
·Faultcausedbyselffixandmodificationwithoutpermission.
·Faultcausedbypoorpreservation
·Faultbyusingtheinverterinabnormal function
·Machinedamagecausedbyfire,saltcorrosion,gascorrosion,earthquake,storm,flood,lightning,
abnormal voltageorotherforcemajeure.
4.Pleasebesuretoretainthiscardandshowittothemaintenanceservice.
User’sInformation
UserCompany: Contactperson:Address: Phone:Dealercompany: Postcode:Model: Serialnumber:Purchasedate: Handlingperson:
RepairRecord
Date Record Abstract Technician Signature