Solar Energy System TC DT - Alliance Roofing & Exteriors · install the GAF Energy solar system. TC...

2
Technical Specifications *STC: Standard Test Conditions 1000W/m 2 , 25°C, AM 1.5. For additional parameters and certifications, refer to the latest version of the GAF Energy solar system Application Instructions Model Number RI 2000 PV Laminate Silfab SLA Mono Maximum Power under STC* (Pmax) 310 Wp Open Circuit Voltage under STC (Voc) 40.25 V Maximum Power Point Voltage under STC (Vmpp) 33.05 V Short Circuit Current under STC (Isc) 9.93 A Maximum Power Point Current under STC (Impp) 9.38 A Module Efficiency under STC (ηm) 19.0% Temperature Correction Factor TC Voc -0.30%/C Cells per module 60 Cell type Monocrystalline PV Connector Type PV wire with MC4 compatible PV Laminate Front 3.2 mm high transmittance, tempered, ar coating PV Laminate Back Multi-layer Polymer Backsheet Frame Black Powder Coated Aluminum Weight 44.4 lb. (20.14 kg) Operating Temperatures -40 to +185°F (-40 to +85°C) Design Loading 50 lb./ft 2 (244 kg/m 2 ) Positive Design Load Certifications SLA-M300|M310 UL 1703 Fire Rating DecoTech ® Frame: UL 2703 Description The sleek, low-profile design of the GAF Energy solar system delivers performance and curb appeal at an affordable price. Product Installation Refer to the Application Instructions for details on how to install the GAF Energy solar system. TECH DATA Design Considerations • GAF Energy solar system must be installed in landscape orientation. • The roof deck must be a minimum of 15/32" thick plywood or 7/16" thick OSB decking. • GAF Energy solar system is intended for use solely on roofs having a slope between 4:12 and 12:12. • DC optimizers or AC inverters can be used. • Asphalt shingle installations only. Solar Energy System

Transcript of Solar Energy System TC DT - Alliance Roofing & Exteriors · install the GAF Energy solar system. TC...

Page 1: Solar Energy System TC DT - Alliance Roofing & Exteriors · install the GAF Energy solar system. TC DT Design Considerations • GAF Energy solar system must be installed in landscape

Technical Specifications

* STC: Standard Test Conditions 1000W/m2, 25°C, AM 1.5. For additional parameters and certifications, refer to the latest version of the GAF Energy solar system Application Instructions

Model Number RI 2000

PV Laminate Silfab SLA Mono

Maximum Power under STC* (Pmax)

310 Wp

Open Circuit Voltage under STC (Voc)

40.25 V

Maximum Power Point Voltage under STC (Vmpp)

33.05 V

Short Circuit Current under STC (Isc)

9.93 A

Maximum Power Point Current under STC (Impp)

9.38 A

Module Efficiency under STC (ηm)

19.0%

Temperature Correction Factor TC Voc

-0.30%/C

Cells per module 60

Cell type Monocrystalline

PV Connector Type PV wire with MC4 compatible

PV Laminate Front 3.2 mm high transmittance, tempered, ar coating

PV Laminate Back Multi-layer Polymer Backsheet

Frame Black Powder Coated Aluminum

Weight 44.4 lb. (20.14 kg)

Operating Temperatures

-40 to +185°F (-40 to +85°C)

Design Loading 50 lb./ft2 (244 kg/m2) Positive Design Load

Certifications SLA-M300|M310 UL 1703

Fire Rating DecoTech® Frame: UL 2703

Description

The sleek, low-profile design of the GAF Energy solar system delivers performance and curb appeal at an affordable price.

Product InstallationRefer to the Application Instructions for details on how to install the GAF Energy solar system.

TECH DATA

Design Considerations

• GAF Energy solar system must be installed in landscape orientation.

• The roof deck must be a minimum of 15/32" thick plywood or 7/16" thick OSB decking.

• GAF Energy solar system is intended for use solely on roofs having a slope between 4:12 and 12:12.

• DC optimizers or AC inverters can be used.

• Asphalt shingle installations only.

Solar Energy System

Page 2: Solar Energy System TC DT - Alliance Roofing & Exteriors · install the GAF Energy solar system. TC DT Design Considerations • GAF Energy solar system must be installed in landscape

©2019 GAF 1/19 • #837 • SM037 gaf.com/solar • 1-800-ROOF-411

Dimensions

TOP CORNER FLASHING- LEFT

TOP FLASHING 2 X

TOP CORNER FLASHING- RIGHT

INNER TOP FLASHING 2 X

TOP FLASHING SUPPORT 3 X

COUNTER FLASHING- RIGHT

COUNTER FLASHING- LEFT

SOLAR PANEL 2X

66.8" L x 21.5" W

21.5" L x 10" W

22.5" L x 4.0" W

41.8" L x 2.29" W

66.5" L x 1.5" W2.92 "H x 41.7" W x 2.26" H

STARTER STRIP

21.5" L x 10" W

43" L x 67.5" W

66.75" W

Solar Energy System