Solar Energy Solutions Product Catalog 2013
Transcript of Solar Energy Solutions Product Catalog 2013
Solar Energy Solutions Product Catalog 2013
2
6
INDEX
MORE THAN 31 GW SUPPLIED TO THE RENEWABLE ENERGY MARKET WORLDWIDE
4 WE DESIGN AND MANUFACTURE A WIDE RANGE OF INVERTERSMORE THAN 3 GW SUPPLIED TO THE SOLAR PV MARKET WORLDWIDE
PRODUCT RANGEALL OUR PRODUCTS ARE CERTIFIED ACCORDING TO
INTERNATIONAL STANDARDS
136 REFERENCES
130
126
BEYOND THE PRODUCT
INGECON® SUN TRAINING THE BEST TRAINING PLATFORM FOR PROFESSIONALS
On-grid PV inverters
Off-grid and micro-grid inverters
Energy management solutions
Micro-wind inverters
Accesories
8
66
76
102
110
2
MORE THAN 31 GW SUPPLIED TO THE RENEWABLE ENERGY MARKET WORLDWIDE
Energy
Industry
Marine
Traction
Basic Technologies
Services
3
Ingeteam is a global corporation
specialized in 6 different sectors
(Energy, Industry, Marine,
Traction, Basic Technologies
and Services), all customer
oriented and based on power
and control electronics,
electrical machines and
application engineering.
With more than 60 years
experience in the electricity
sector, more than 3,000
professionals dedicated to
engineering and project
development, and more than
31 GW supplied to the
renewable energy market
worldwide, Ingeteam is
committed to investing in
technology and innovation as
the drivers of future growth.
Since 1990, the Energy
business unit of Ingeteam
Power Technology, S.A. has
been dedicated to supplying
equipment for the renewable
energies sector (wind power,
photovoltaic, solar thermal,
hydropower, biomass
and biofuels).
4
WE DESIGN AND MANUFACTURE A WIDE RANGE OF INVERTERSMORE THAN 3 GW SUPPLIED TO THE
SOLAR PV MARKET WORLDWIDE
5
Ingeteam is a leading company
in the PV sector worldwide. The
electronics and software have
been specially developed for the
INGECON® inverters, resulting
in a high-quality end product,
adaptable to the specifi c
characteristics of each plant.
With an annual 3 GW production
capacity, Ingeteam offers the
following product range:
Grid-connected inverters
from 2.5 to 1,000 kW.
Off-grid and micro-grid
inverters from 2.4 to 120 kW.
Energy management solutions
(inverters for batteries).
String currents monitoring
equipment.
Communications, software
and hardware.
All these products are
customized to suit the
requirements of each and
every customer, in line with
one of Ingeteam’s core values:
Customer guidance, service and adaptability.
6
EMS Home
2.5-6 kW
p. 80
EMS Manager
p. 79
HYBRID AC Link
2.4-6 kW
p. 68
String Control
p. 118
LOC
p. 116
HYBRID
10 kW
p. 72
3Play
10-40 kW
p. 18
Smart
10-30 kW
p. 26
1Play
2.5-10 kW
p. 10
Lite
2.5-10 kW
p. 20
Smart TL10-18 kW
p. 24
Off-g
rid a
nd m
icro
-grid
inve
rters
On-g
rid
PV in
vert
ers
Comunicación
p. 112
ComBox
p. 114
Weather Box
p. 115
Acce
sori
es
Ener
gy m
anag
emen
t sol
utio
n
PRODUCT RANGEALL OUR PRODUCTS ARE CERTIFIED ACCORDING TO
INTERNATIONAL STANDARDS
HYBRID MS
30-120 kW
p. 74
7
PowerStation SHELTER300-2100 kW
p. 56
PowerMax
275-1019 kW
p. 32
PowerStation CONTAINER
300-2100 kW
p. 60
EMS Plants
275-1019 kW
p. 84
EMS Plant Manager
p. 100
Manager
p. 119
Planner
p. 121
SCADA y Telemando
p. 122
iSun Monitor
p. 120
μWIND Interface
2.5-18 kW
p. 108
μWIND
2.5-6 kW
p. 104
Mic
ro-w
ind
inve
rter
sPower
50-250 kW
p. 28
ON-GRID PV INVERTERS
10
11
On-g
rid
PV in
vert
ers
The INGECON® SUN 1Play single-phase PV inverter family
has been designed to achieve maximum energy performance
and also to facilitate user access to the PV plant.
1Play inverters are valid for low kilowatt residential
applications and also for decentralised commercial and
industrial systems rated up to several hundred kilowatts.
Plug & Play TechnologyExtremely easy to install. The fast-on connectors for the DC
and AC sides means that the inverters simply need to be
connected and are ready for use, whilst the country-specifi c
confi guration and language can be easily selected from the
inverter screen.
Models to suit all types of technologies
This new inverter family is fully compatible with all the PV
module technologies on the market.
The 1Play inverter family comprises three models with
different characteristics, making it possible to adapt to the
specifi c needs of each and every system:
INGECON® SUN 1Play HF. Inverters with outputs from
2.5 to 6 KW, with galvanic isolation provided through
a high frequency transformer, with the possibility of
grounding the PV generator.
INGECON® SUN 1Play TL. Transformerless inverters with
outputs from 2.5 to 10 kW, with a maximum power point
tracker (MPPT).
INGECON® SUN 1Play TL M. Transformerless inverters
with outputs from 2.5 to 6 kW, with two maximum power
point trackers (MPPT) and a wider input voltage range,
offering greater PV solar array confi guration possibilities.
Maximum effi ciency valuesThrough the use of innovative electronic conversion
topologies, effi ciency values of up to 98% can be achieved.
Furthermore, an advanced MPPT algorithm makes it
possible to harness the maximum energy from the PV array
at all times, even in diffi cult situations, such as scattered
clouds and partial shading.
Easy to operateIngeteam is at the forefront of innovative fi rmware. As a
result, the INGECON® SUN 1Play inverters are extremely
easy to operate. The menu displayed on the LCD screen
has been designed so that it is simple and easy to use.
The display also features a number of LEDs to indicate the
inverter operating status. These LEDs light up whenever
any incident is detected, thereby simplifying and facilitating
equipment maintenance tasks.
Monitoring and communicationThe internal operating variables and the historical production
data can be monitored through a number of media such as
RS-485, Ethernet, GSM/GPRS and Bluetooth.
The following applications are included at no extra cost:
INGECON® SUN Manager, INGECON® SUN Monitor and
its iSun Monitor smartphone version, for monitoring and
recording the inverter data over the internet.
Updating the fi rmware (FW)The 1play HF and 1Play TL M allow the user to download the
latest inverter fi rmware version from the www.ingeteam.com
website, using a simple SD memory card.
Able to withstand extreme conditionsThe 1Play inverter housing is suitable for outdoor use (IP65
protection rating). Likewise, its innovative ventilation system
allows it to be used in extreme atmospheric conditions with
temperature ranges from -20ºC to +70ºC.
Service life of more than 20 yearsIngeteam takes every care in the selection and sizing of
the electronic components used for its inverters. The 1Play
inverters have been designed to guarantee a service life of
more than 20 years, as demonstrated by the stress tests
they are subjected to.
Twinned with the INGECON® SUN 3Play three-phase inverter familyThis single-phase family is completed with the new
INGECON® SUN 3Play TL M three-phase inverters, with an
output range from 10 to 40 kW, and which are also intended
for the residential, commercial and industrial markets.
A new family of single-phase inverters
Power (kW)
3.5 40
90
93
98
94
91
99
97
95
96
92
1 1.50.5 2 2.5 3 4.5 5
Effi
cie
ncy
(%)
EFFICIENCY
INGECON® SUN 5TL M
Vdc = 330 V
12
HF
generator is also facilitated through built-
in fuse holders. The country-specifi c
confi guration and language can be
easily selected from the inverter screen.
Effi ciency and versatilityNew design valid for indoor and outdoor
installations (IP65), able to withstand
extreme temperatures. What’s more
these inverters feature an innovative
electronic conversion topology which,
together with an advanced maximum
power point tracking system (MPPT),
leads of high effi ciency, positioning
these inverters as market leaders.
The INGECON® SUN 1Play HF is
equipped with four digital, multi-
purpose inputs which can be used, for
example, to reduce the inverter power
output through an external setpoint.
Confi gurable for self-consumption mode.
OPTIONAL ACCESSORIES
DC breaker.
Inverter communication via Bluetooth,
Ethernet or RS-485.
GSM/GPRS remote communication.
Display-confi gurable potential free
contact, to indicate insulation fault or grid
connection.
PROTECTIONS
Galvanic isolation between
the DC and AC sides.
Reverse polarity.
Input and output overvoltages with
type 3 surge arresters.
Output short-circuits and overloads.
Insulation failures.
Anti-islanding with automatic
disconnection.
Grounding kit if required for the PV
modules.
Galvanic isolation in a compact size
2.5HF / 2.7HF / 3HF / 3.3HF / 3.68HF / 4.6HF / 5HF / 5.5HF / 6HF
A new family of single phase inverters,
intended for the residential sector and
for larger, decentralised projects.
High frequency technologyA high frequency transformer provides
galvanic isolation between the input and
output. This reduces the weight of the
converter and increases the effi ciency in
relation to low frequency inverters with
conventional galvanic isolation (50/60 Hz).
The INGECON® SUN 1Play HF
inverters are compatible with all the PV
module technologies on the market,
whilst allowing the PV generator to be
grounded whenever required.
Easy to installThe inverter features fast-on connectors
on the DC side (type 4) and the AC
side for a fast and easy connection to
the system. The grounding of the PV
0
88
91
94
92
89
95
96
97
93
90
1 2 3 4 5
Power (kW)
Effi
cie
ncy
(%)
EFFICIENCY
INGECON® SUN 5HF
Vdc = 430 V
Simple operation and maintenanceInternal datalogger for several months
data storage, accessible from a PC or
SD card. Inverter operation from either
a remote PC or on-site from the inverter
front keypad through its LCD screen.
Status and alarm LED indicators.
Software includedIncluded at no extra cost are the
INGECON® SUN Manager, INGECON®
SUN Monitor and its iSun Monitor
smartphone version for monitoring
and recording the inverter data over
the internet. In addition, users can
download the latest version of the
fi rmware from the Ingeteam website:
www.ingeteam.com, and update it
using a simple SD memory card.
Standard 5 year warranty, extendable for up to 25 years
13
On-g
rid
PV in
vert
ers
INGECON® SUN 1Play HF
1Play HF
Size and weight (mm)
3.3HF / 3.68HF22 kg.
2.5HF 2.7HF 3HF 3.3HF 3.68HF 4.6HF 5HF 5.5HF 6HF
Input (DC)
Recommended PV array power range(1) 2.8 - 3.3 kWp 3 - 3.6 kWp 3.2 - 4 kWp 3.8 - 4.3 kWp 3.9 - 4.8 kWp 5.2 - 6 kWp 5.7 - 6.5 kWp 6 - 6.75 kWp 6.3 - 7 kWp
Voltage range MPP 170 - 450 V 180 - 450 V 190 - 450 V 170 - 450 V 170 - 450 V 155 - 450 V 170 - 450 V 180 - 450 V 185 - 450 V
Voltage range DC(2) 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V
Maximum current DC 17 A 17 A 17 A 22 A 22 A 33 A 33 A 33 A 33 A
DC inputs 3 3 3 3 3 4 4 4 4
MPPT 1 1 1 1 1 1 1 1 1
Output (AC)Rated power AC 2.5 kW 2.7 kW 3 kW 3.3 kW 3.68 kW 4.6 kW 5 kW 5.5 kW 6 kW
Maximum current AC 13.5 A 13.5 A 13.5 A 17 A 17 A 26.2 A 26.2 A 26.2 A 26.2 A
Rated voltage AC 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine 1 1 1 1 1 1 1 1 1
Phi Cosine adjustableYes.
Smax=2.5 kVA
Yes.
Smax=2.7 kVA
Yes.
Smax=3 kVA
Yes.
Smax=3.3 kVA
Yes.
Smax=3.68 kVA
Yes.
Smax=4.6 kVA
Yes.
Smax=5 kVA
Yes.
Smax=5.5 kVA
Yes.
Smax=6 kVA
THD <3% <3% <3% <3% <3% <3% <3% <3% <3%
Effi ciencyMaximum effi ciency 96% 96% 96% 96% 96% 96% 96% 96% 96%
Euroeffi ciency 95.2% 95.2% 95.2% 95.2% 95.2% 95.2% 95.2% 95.2% 95.2%
General InformationAir cooling 30 m3/h 30 m3/h 30 m3/h 45 m3/h 45 m3/h 90 m3/h 90 m3/h 90 m3/h 90 m3/h
Stand-by consumption(3) <10 W <10 W <10 W <10 W <10 W <10 W <10 W <10 W <10 W
Consumption at night 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 W
Ambient temperature -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC
Relative humidity
(non-condensing)0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95%
Protection class IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65
2.5HF / 2.7HF / 3HF20 kg.
360
180
47
0
Notes: (1) Depending on the type of installation and geographical location (2) Must not be exceeded under any circumstances. Consider the voltage increase of the ‘Voc’ at low temperatures (3) AC Power for 45ºC ambient temperature (4) Consumption from PV fi eld.
Compliance with standards: EN62109-1, EN62109-2, EN61000-6-2, EN61000-6-3, EN50438, RD1699/2011, P.O.12.3, VDE-AR-N-4105, VDE0126-1-1, CEI 11-20 V1, CEI 0-21, Allegato
70 TERNA, CEI 0-16 Ed. III, G83/1-1, G83/2, AS4777.2, AS4777.3, AS3100.
Optional
Filt
er
High frequency
transformerL
N
AC output
for grid
connectionPV input
4.6HF / 5HF / 5.5HF / 6HF25 kg.
14
TL
1Play TL Size and weight (mm)
360
180
47
0
2.5TL 2.7TL / 3TL18.3 kg.
3.3TL / 3.68TL19.7 kg.
4.6TL / 5TL5.5TL / 6TL
7.5TL / 8.2TL 8.6TL / 10TL
23.3 kg.
25.2 kg.
Simple installation and maintenanceFast-on connectors on the DC side (type
4) and the AC side and RS-485 serial
communications. The country-specifi c
confi guration and language can be
easily selected from the inverter screen.
The INGECON® SUN 1Play TL inverters
feature an internal datalogger for three
months’ data storage with control from
either a remote PC or on-site from the
from the inverter front keypad through
its LCD screen. Status and alarm LED
A single phase inverter, intended for
the residential sector and for larger,
decentralised projects.
Wide range of AC power outputsThe INGECON® SUN 1Play TL single
phase inverters offer an extensive range
of power outputs from 2.5 to 10 kW. As
a new addition, this range of inverters
can now be supplied for 7.5 kW, 8.2 kW,
8.6 kW and 10 kW.
indicators. Fans are easily replaceable
by the user.
Confi gurable for self-consumption mode.
Software includedIncluded at no extra cost are the
INGECON® SUN Manager, INGECON® SUN
Monitor and its iSun Monitor smartphone
version for monitoring and recording the
inverter data over the internet.
Standard 5 year warranty, extendable for up to 25 years
An inverter family with a wide range of outputs from 2.5 to 10 kW
2.5TL / 2.7TL / 3TL / 3.3TL / 3.68TL / 4.6TL / 5TL / 5.5TL / 6TL / 7.5TL / 8.2TL / 8.6TL / 10TL
0
75
83
95
85
78
100
98
93
88
90
80
2 31 4 5 76 8 9 10
Power (kW)
Effi
cie
ncy
(%)
EFFICIENCY
INGECON® SUN 10TL
Vdc = 330 V
OPTIONAL ACCESSORIES
DC breaker.
Inverter communication via Bluetooth,
Ethernet or RS-485.
GSM/GPRS remote communication.
Display-confi gurable potential free
contact, to indicate insulation fault or grid
connection.
PROTECTIONS
Reverse polarity.
Input and output
overvoltages with type 3
surge arrester monitoring.
Output short-circuits and
overloads.
Insulation failures.
Anti-islanding with
automatic disconnection.
L
NOptional
PV input
AC output
for grid
connection
Inverter
Filt
er
15
On-g
rid
PV in
vert
ers
INGECON® SUN 1Play TL
Notes: (1) Depending on the type of installation and geographical location (2) Must not be exceeded under any circumstances. Consider the voltage increase of the ‘Voc’ at low temperatures (3) AC Power for 45ºC ambient temperature (4) Voltage confi gurable through the display (5) Consumption from PV fi eld.
Compliance with standards: EN50438, EN62109-1, EN62109-2, EN61000-6-2, EN61000-6-3, RD1699/2011, P.O.12.3, VDE-AR-N4105, CEI 11-20 V1, CEI 0-21, Allegato 70 TERNA, CEI 0-16 Ed. III, VDE0126-1-1,
G83/1-1, G83/2, AS4777.2, AS4777.3, AS3100.
2.5TL 2.7TL 3TL 3.3TL 3.68TL 4.6TL 5TL
Input (DC)
Recommended PV array power range(1) 2.8 - 3.3 kWp 3 - 3.6 kWp 3.2 - 4 kWp 3.8 - 4.3 kWp 3.9 - 4.8 kWp 5.2 - 6 kWp 5.7 - 6.5 kWp
Voltage range MPP 160 - 450 V 180 - 450 V 195 - 450 V 155 - 450 V 175 - 450 V 145 - 450 V 160 - 450 V
Voltage range DC(2) 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V
Maximum current DC 17 A 17 A 17 A 22 A 22 A 33 A 33 A
DC inputs 3 3 3 3 3 4 4
MPPT 1 1 1 1 1 1 1
Output (AC)
Rated power AC(3) 2.5 kW 2.7 kW 3 kW 3.63 kW 3.68 kW 4.6 kW 5 kW
Maximum current AC 13 A 13 A 13.5 A 17 A 17 A 24.2 A 26.2 A
Rated voltage AC 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine 1 1 1 1 1 1 1
Phi Cosine adjustable Yes. Smax=2.5 kVA Yes. Smax=2.7 kVA Yes. Smax=3 kVA Yes. Smax=3.63 kVA Yes. Smax=3.68 kVA Yes. Smax=4.6 kVA Yes. Smax=5 kVA
THD <3% <3% <3% <3% <3% <3% <3%
Effi ciency
Maximum effi ciency 96.6% 96.6% 96.6% 96.8% 96.8% 97% 97%
Euroeffi ciency 95% 95% 95.1% 95.2% 95.2% 96% 96.1%
General InformationAir cooling 30 m3/h 30 m3/h 30 m3/h 45 m3/h 45 m3/h 90 m3/h 90 m3/h
Stand-by consumption(5) <10 W <10 W <10 W <10 W <10 W <10 W <10 W
Consumption at night 0 W 0 W 0 W 0 W 0 W 0 W 0 W
Ambient temperature -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95%
Protection class IP65 IP65 IP65 IP65 IP65 IP65 IP65
5.5TL 6TL 7.5TL 8.2TL 8.6TL 10TL
Input (DC)Recommended PV array power range(1) 6 - 6.75 kWp 6.3 - 7 kWp 8.7 - 10.3 kWp 9.5 - 11.2 kWp 10 - 11.8 kWp 11.6 - 13.7 kWp
Voltage range MPP 180 - 450 V 190 - 450 V 215 - 450 V 235 - 450 V 245 - 450 V 300 - 450 V
Voltage range DC(2) 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V
Maximum current DC 33 A 33 A 35 A 35 A 35 A 35 A
DC inputs 4 4 4 4 4 4
MPPT 1 1 1 1 1 1
Output (AC)Rated power AC(3) 5.5 kW 6 kW 7.5 kW 8.2 kW 8.6 kW 10 kW
Maximum current AC 26.2 A 26.2 A 36.1 A 36.1 A 36.1 A 36.1 A
Rated voltage AC 230 / 240 V 230 / 240 V 208 / 230 / 240 / 277 V(4) 230 / 240 / 277 V(4) 240 / 277 V(4) 277 V
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine 1 1 1 1 1 1
Phi Cosine adjustable Yes. Smax=5.5 kVA Yes. Smax=6 kVA Yes. Smax=7.5 kVA Yes. Smax=8.2 kVA Yes. Smax=8.6 kVA Yes. Smax=10 kVA
THD <3% <3% <3% <3% <3% <3%
Effi ciencyMaximum effi ciency 97% 97% 97.5% 97.6% 97.65% 98%
Euroeffi ciency 96.2% 96.1% 96.5% 96.55% 96.6% 96.8%
General InformationAir cooling 90 m3/h 90 m3/h 90 m3/h 90 m3/h 90 m3/h 90 m3/h
Stand-by consumption(5) <10 W <10 W <10 W <10 W <10 W <10 W
Consumption at night 0 W 0 W 0 W 0 W 0 W 0 W
Ambient temperature -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95%
Protection class IP65 IP65 IP65 IP65 IP65 IP65
16
TL M
topology allows these inverters to
reach maximum effi ciency values of
more than 98%, whilst eliminating
eddy currents from the PV array and
permitting the use of 30mA differential
circuit breakers in the system.
Four digital, multi-purpose inputs
are available. These can be used, for
example, to reduce the inverter power
output through an external setpoint.
Confi gurable for self-consumption
mode.
Plug & Play TechnologyInstallation is fast and simple, thanks
to the fast-on connectors on the
DC (type 4) and AC sides. The
country-specifi c confi guration and
language can be easily selected from
the inverter screen.
Maximum performance with multi-string technology
2.5TL M / 2.7TL M / 3TL M / 3.3TL M / 3.68TL M / 4.6TL M / 5TL M / 5.5TL M / 6TL M
A new family of single-phase inverters
with two maximum power point trackers
and a wide range of input voltages,
intended for the residential sector and
for larger, decentralised projects.
Double MPPT inputThe INGECON® SUN 1Play TL M
inverter family features two maximum
power point trackers (MPPT) and a
wide input voltage range, offering great
fl exibility for confi guring the PV array
and the possibility of asymmetrical
confi gurations.
Enhanced functionalityThanks to its innovative design, intended
for indoor and outdoor installation
(IP65), these inverters are able to
withstand extreme climatic conditions.
Furthermore, their high performance
Ease of maintenanceInternal datalogger for several months
data storage readable from a PC or SD
card. Control either from a remote PC or
on-site from the inverter front keypad.
Status and alarm LED indicators.
Software includedIncluded at no extra cost are the
INGECON® SUN Manager, INGECON®
SUN Monitor and its iSun Monitor
smartphone version for monitoring
and recording the inverter data over
the internet. In addition, users can
download the latest version of the
fi rmware from the Ingeteam website:
www.ingeteam.com, and update it
using a simple SD memory card.
Standard 5 year warranty, extendable for up to 25 years
0
75
83
95
85
78
100
98
93
88
90
80
1 1.50.5 2 2.5 3.53 4 4.5 5
Power (kW)
Effi
cie
ncy
(%)
EFFICIENCY
INGECON® SUN 5TL M
Vdc = 330 V
OPTIONAL ACCESSORIES
DC breaker.
Inverter communication via Bluetooth,
Ethernet or RS-485.
GSM/GPRS remote communication.
Display-confi gurable potential free
contact, to indicate insulation fault or grid
connection.
PROTECTIONS
Reverse polarity.
Input and output
overvoltages with type 3
surge arrester monitoring.
Output short-circuits and
overloads.
Insulation failures.
Anti-islanding with
automatic disconnection.
17
On-g
rid
PV in
vert
ers
INGECON® SUN 1Play TL M
N
Size and weight (mm)
2.5TL M / 2.7TL M / 3TL M17.3 kg.
3.3TL M / 3.68TL M18.7 kg.
4.6TL M / 5TL M / 5.5TL M / 6TL M22.3 kg.
360
180
47
0
1Play TL M
Optional
Filt
er
PV input
PV input
AC output
for grid
connection
MPP1
MPP2
Compliance with standards: EN50438, EN62109-1, EN62109-2, EN61000-6-2, EN61000-6-3, RD1699/2011, P.O.12.3, VDE-AR-N4105, CEI 11-20 V1, CEI 0-21, Allegato 70 TERNA,
CEI 0-16 Ed. III, VDE0126-1-1, G83/1-1, G83/2, AS4777.2, AS4777.3, AS3100.
Notes: (1) Depending on the type of installation and geographical location (2) The output power will be conditioned by the voltage and current confi guration selected at each input (3) To
drop to 90 V, the other input must at least be at 125 V (4) Must not be exceeded under any circumstances. Consider the voltage increase of the ‘Voc’ at low temperatures (5) AC Power
for 45ºC ambient temperature (6) Consumption from PV fi eld.
2.5TL M 2.7TL M 3TL M 3.3TL M 3.68TL M 4.6TL M 5TL M 5.5TL M 6TL M
Input (DC)
Recommended PV array power range(1) 2.8 - 3.3 kWp 3 - 3.6 kWp 3.2 - 4 kWp 3.8 - 4.4 kWp 3.9 - 4.8 kWp 5.2 - 6 kWp 5.7 - 6.5 kWp 6 - 6.75 kWp 6.3 - 7 kWp
Voltage range MPP(2) 125 - 750 V 125 - 750 V 125 - 750 V 125 - 750 V 125 - 750 V 125 - 750 V 125 - 750 V 125 - 750 V 125 - 750 V
Voltage range MPP2(2) (3) 90 - 750 V 90 - 750 V 90 - 750 V 90 - 750 V 90 - 750 V 90 - 750 V 90 - 750 V 90 - 750 V 90 - 750 V
Min. voltage for Pnom with parallel
DC inputs125 V 135 V 150 V 165 V 184 V 230 V 250 V 275 V 300 V
Maximum DC voltage(4) 900 V 900 V 900 V 900 V 900 V 900 V 900 V 900 V 900 V
Maximum current DC (Input 1/ Input 2) 10 / 10 A 10 / 10 A 10 / 10 A 10 / 10 A 10 / 10 A 10 / 10 A 10 / 10 A 10 / 10 A 10 / 10 A
DC inputs (Input 1/ Input 2) 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1
MPPT 2 2 2 2 2 2 2 2 2
Output (AC)Rated power AC(5) 2.5 kW 2.7 kW 3 kW 3.3 kW 3.68 kW 4.6 kW 5 kW 5.5 kW 6 kW
Maximum current AC 13.5 A 13.5 A 13.5 A 17 A 17 A 26.2 A 26.2 A 26.2 A 26.2 A
Rated voltage AC 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine 1 1 1 1 1 1 1 1 1
Phi Cosine adjustableYes.
Smax=2.5 kVA
Yes.
Smax=2.7 kVA
Yes.
Smax=3 kVA
Yes.
Smax=3.3 kVA
Yes.
Smax=3.68 kVA
Yes.
Smax=4.6 kVA
Yes.
Smax=5 kVA
Yes.
Smax=5.5 kVA
Yes.
Smax=6 kVA
THD <3% <3% <3% <3% <3% <3% <3% <3% <3%
Effi ciencyMaximum effi ciency 97.6% 97.6% 97.7% 97.7% 97.8% 97.9% 98% 98% 98%
Euroeffi ciency 97.3% 97.3% 97.4% 97.4% 97.5% 97.5% 97.6% 97.6% 97.6%
General InformationAir cooling 30 m3/h 30 m3/h 45 m3/h 45 m3/h 45 m3/h 90 m3/h 90 m3/h 90 m3/h 90 m3/h
Stand-by consumption(6) <10 W <10 W <10 W <10 W <10 W <10 W <10 W <10 W <10 W
Consumption at night 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 W 0 W
Ambient temperature -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC
Relative humidity
(non-condensing)0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95%
Protection class IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65
18
Transformerless
fast-on connectors for the DC (type
4) and AC sides, whilst the country-
specifi c confi guration and language
can be easily selected from the inverter
screen.
Rugged designSteel and aluminium casing, specially
designed for indoor and outdoor
applications (IP65). Able to withstand
extreme temperatures. The 3Play
inverters have been designed to
guarantee a service life of more than
20 years, as demonstrated by the
stress tests they are subjected to.
Ease of maintenanceInternal datalogger for up to 3 months
data storage. Control either from a
remote PC or on-site from the inverter
A three-phase inverter family for domestic,
industrial and PV fi eld applications.
Maximum effi ciency with two independent MPPT inputsA single power conversion stage with
an advanced maximum power point
tracking system (MPPT), making it
possible to harness the maximum energy
from the PV array at all times, including
diffi cult situations such as scattered
clouds and partial shading. Great
fl exibility for confi guring the solar array,
thanks to the two MPPT trackers with a
wide input voltage range. Possibility of
asymmetrical confi gurations.
Plug & Play technologyExtremely easy to install. The inverter
connection is fast and simple through
front keypad. Status and alarm LED
indicators. LCD screen. Fans are easily
replaceable by the user.
Software includedIncluded at no extra cost are the
INGECON® SUN Manager, INGECON®
SUN Monitor and its iSun Monitor
smartphone version for monitoring
and recording the inverter data over
the internet. In addition, users can
download the latest version of the
fi rmware from the Ingeteam website:
www.ingeteam.com, and update it
using a simple SD memory card.
Standard 5 year warranty, extendable for up to 25 years
Maximum effi ciency with multi-MPPT three-phase technology
10TL M / 12.5TL M / 15TL M / 20TL M / 28TL M / 33TL M / 40TL M
OPTIONAL ACCESSORIES
DC breaker.
Type 2 additional surge arrester to protect
against overvoltages at the AC output.
Inverter communication via Bluetooth, Ethernet
or RS-485.
GSM/GPRS remote communication.
DC input overvoltage surge arrester, type 2.
Display-confi gurable potential free contact, to
indicate insulation fault or grid connection.
AC selector.
Multi-contact kit.
Multi-contact kit + DC fuses.
Multi-contact kit + DC fuses + DC current
measurement.
PROTECTIONS
Overvoltages at the AC
output with type 3
surge arresters.
Short-circuits and
overloads at the output.
Insulation faults.
Anti-islanding with
automatic disconnection.
Reverse polarity.90
93
96
94
91
97
98
99
95
92
0 2 4 6 108 12 14 16 18 20
Power (kW)
Effi
cie
ncy
(%)
EFFICIENCY
INGECON® SUN 20TL M
Vdc = 650 V
19
On-g
rid
PV in
vert
ers
INGECON® SUN 3Play transformerless
Size and weight (mm)
10TL M / 12,5TL M / 15TL M / 20TL M60 kg.
65
0
250
650
75
0
250
750
28TL M / 33TL M / 40TL M 75 kg.
Notes: (1) Depending on the type of installation and geographical location (2) The output power will be conditioned by the voltage and current confi guration selected at each input (3) Must
not be exceeded under any circumstances. Consider the voltage increase of the ‘Voc’ at low temperatures (4) PG input. Kit MC available (5) AC Power for 45ºC ambient temperature (6) For
Pout>25% of the rated power (7) Consumption from PV fi eld.
Compliance with standards: EN62109-1, EN62109-2, EN61000-6-2, EN61000-6-3, RD1699/2011, P.O.12.3, VDE-AR-N-4105, VDE0126-1-1, CEI 11-20 V1, CEI 0-21, Allegato 70 TERNA, CEI 0-16 Ed. III, BDEW,
AS4777.2, AS4777.3, AS3100, G83/1-1, G83/2, G59/2.
10TL M 12.5TL M 15TL M 20TL M 28TL M 33TL M 40TL M
Input (DC)
Recommended PV array power range(1) 10 - 13 kW 12.5 - 16.25 kW 15 - 19.5 kW 20 - 26 kW 28 - 36.4 kW 33 - 42.9 kW 40 - 52 kW
Voltage range MPP1(2) 200 - 820 V 200 - 820 V 200 - 820 V 200 - 820 V 200 - 820 V 200 - 820 V 200 - 820 V
Voltage range MPP2(2) 200 - 820 V 200 - 820 V 200 - 820 V 200 - 820 V 200 - 820 V 200 - 820 V 200 - 820 V
Min. voltage for Pnom with parallel
DC inputs250 V 312.5 V 300 V 400 V 400 V 412.5 V 444.44 V
Maximum DC voltage(3) 1,000 V 1,000 V 1,000 V 1,000 V 1,000 V 1,000 V 1,000 V
Maximum current DC
(Input 1/Input 2)20 / 20 A 20 / 20 A 30 / 20 A 30 / 20 A 40 / 30 A 40 / 40 A 50 / 40 A
DC inputs(4) (Input 1/Input 2) 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1
MPPT 2 2 2 2 2 2 2
Output (AC)Rated power AC(5) 10 kW 12,5 kW 15 kW 20 kW 28 kW 33 kW 40 kW
Maximum current AC 14 A 18 A 22 A 29 A 40 A 48 A 58 A
Rated voltage AC 400 V 400 V 400 V 400 V 400 V 400 V 400 V
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(6) 1 1 1 1 1 1 1
Phi Cosine adjustable Yes. Smax=10 kVA Yes. Smax=12.5 kVA Yes. Smax=15 kVA Yes. Smax=20 kVA Yes. Smax=28 kVA Yes. Smax=33 kVA Yes. Smax=40 kVA
THD <3% <3% <3% <3% <3% <3% <3%
Effi ciencyMaximum effi ciency 98.4% 98.4% 98.4% 98.4% 98.5% 98.5% 98.5%
Euroeffi ciency 98.1% 98.2% 98.2% 98.2% 98.2% 98.2% 98.2%
General InformationAir cooling 150 m3/h 150 m3/h 300 m3/h 300 m3/h 385 m3/h 385 m3/h 385 m3/h
Stand-by consumption(7) 20 W 20 W 20 W 20 W 20 W 20 W 20 W
Consumption at night 1 W 1 W 1 W 1 W 1 W 1 W 1 W
Ambient temperature -20ºC to 65ºC -20ºC to 65ºC -20ºC to 65ºC -20ºC to 65ºC -20ºC to 65ºC -20ºC to 65ºC -20ºC to 65ºC
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95%
Protection class IP65 IP65 IP65 IP65 IP65 IP65 IP65
* Also available without DC measurement or DC fuses.
3Play TL M
OptionalOptionalOptional*
Inverter
Optional Optional
MPP1
MPP2
L1
L2
L3
N N
L3
L2
L1
PV input
PV input
AC output for
connection to
the grid
Filt
er
20
0
65
80
95
85
70
100
90
75
1 1.50.5 2 2.5 3.53 4 4.5 5
Power (kW)
Effi
cie
ncy
(%)
EFFICIENCY
INGECON® SUN 5
Vdc = 330 V
OPTIONAL ACCESSORIES
PROTECTIONSGreater fl exibility for PV system sizingCompatible with the various PV module
technologies available on the market.
Maximum effi ciencyAdvanced maximum power point tracking
system (MPPT).
Robust designGalvanic isolation. Aluminium housing for
indoor and outdoor installation.
It withstands extreme temperatures.
Easy to installFast on connectors for the DC and AC sides,
transformer and RS-485 communications.
No additional items required. Manual grid
disconnection feature.
Confi gurable for self-consumption mode.
Ease of maintenanceInternal datalogger for up to 3 months
data storage, which can be controlled
from either a remote PC or on-site from
the inverter front key pad. LED status and
alarm indicators and LCD screen. Useful
life of more than 20 years.
Software includedIncluded at no extra cost are the
INGECON® SUN Manager, INGECON® SUN
Monitor and its iSun Monitor smartphone
version for monitoring and recording the
inverter data over the internet.
Standard 5 year warranty, extendable for up to 25 years
A single phase inverter designed for use in the residential sector and for larger, decentralised projects
Galvanic isolation between
the DC and AC sides.
Reverse polarity.
Input and output overvoltage,
type 3.
Output short circuits
and overloads.
Insulation failures.
Anti-islanding with automatic
shutdown.
DC breaker.
Inter-inverter communication via
Ethernet, Bluetooth or RS-485.
GSM/GPRS remote
communication.
Grounding kit if required for
the PV modules.
Potential free contact for
insulation fault indication
(by default) or inverter connected
to the grid (optional).
2.5 / 3.3 / 5
With transformer
21
On-g
rid
PV in
vert
ers
INGECON® SUN Lite with transformer
Size and weight (mm)
Lite
Inverter
Optional
Filt
er
TransformerL
N
AC output
for grid
connectionPV input
Transformer
47
0
180
360
320
140
32
0
2.543.3 kg.
3.344.7 kg.
565 kg.
2.5 3.3 5
Input (DC)
Recommended PV array power range(1) 2.8 - 3.3 kWp 3.8 - 4.3 kWp 5.8 - 6.5 kWp
Voltage range MPP 160 - 450 V 155 - 450 V 160 - 450 V
Voltage range DC(2) 125 - 550 V 125 - 550 V 125 - 550 V
Maximum current DC 17 A 22 A 33 A
DC inputs 3 3 4
MPPT 1 1 1
Output (AC)Rated power AC(3) 2.7 kW 3.7 kW 5.5 kW
Maximum current AC 12 A 16 A 22 A
Rated voltage AC 230 / 240 V 230 / 240 V 230 / 240 V
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine 1 1 1
Phi Cosine adjustable Yes. Smax=2.7 kVA Yes. Smax=3.7 kVA Yes. Smax=5.5 kVA
THD <3% <3% <3%
Effi ciencyMaximum effi ciency 94.9% 95% 95.1%
Euroeffi ciency 93.8% 94.5% 94.3%
General InformationAir cooling 0 m3/h 45 m3/h 90 m3/h
Stand-by consumption(4) <10 W <10 W <10 W
Consumption at night 0 W 0 W 0 W
Ambient temperature -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP65 IP65 IP65
Notes: (1) Depending on the type of installation and geographical location (2) Must not be exceeded under any circumstances. Consider the voltage increase of the ‘Voc’ at low
temperatures (3) AC Power for 45ºC ambient temperature. For each ºC of increase, the output power will be reduced at the rate of 1.8% (4) Consumption from PV fi eld.
Compliance with standards: CE, EN50438, IEC61000-6-2, IEC61000-6-3, EN50178, RD1699/2011, P.O.12.3, VDE-AR-N-4105, VDE0126-1-1, CEI 11-20 V1, CEI 0-21, Allegato 70 TERNA, CEI 0-16 Ed. III, G83/1-1,
G83/2, AS4777.2, AS4777.3, AS3100.
22
Transformerless
Lite TL Size and weight (mm)
2.5TL / 3TL18.3 kg.
3.3TL / 3.68TL19.7 kg.
4.6TL5TL / 6TL
7.5TL / 8.2TL 8.6TL / 10TL
23.3 kg.
25.2 kg.
Simple installation and maintenanceFast-on connectors on the DC side (type
4) and the AC side and RS-485 serial
communications. The country-specifi c
confi guration and language can be
easily selected from the inverter screen.
The INGECON® SUN Lite TL TL
inverters feature an internal datalogger
for three months’ data storage with
control from either a remote PC or
on-site from the from the inverter front
keypad through its LCD screen. Status
A new family of single-phase
transformerless inverters, intended for
the residential sector and for larger,
decentralised projects.
Wide range of AC power outputsThe INGECON® SUN Lite TL single
phase inverters offer an extensive range
of power outputs from 2.5 to 10 kW. As
a new addition, this range of inverters
can now be supplied for 7.5 kW, 8.2 kW,
8.6 kW and 10 kW.
and alarm LED indicators. Fans are easily
replaceable by the user.
Confi gurable for self-consumption mode.
Software includedIncluded at no extra cost are the
INGECON® SUN Manager, INGECON® SUN
Monitor and its iSun Monitor smartphone
version for monitoring and recording the
inverter data over the internet.
Standard 5 year warranty, extendable for up to 25 years
An inverter family with a wide range of outputs from 2.5 to 10 kW
2.5TL / 3TL / 3.3TL / 3.68TL / 4.6TL / 5TL / 6TL / 7.5TL / 8.2TL / 8.6TL / 10TL
OPTIONAL ACCESSORIES
DC breaker.
Inter-inverter communication via Ethernet,
Bluetooth or RS-485.
GSM/GPRS remote communication.
Potential free contact for insulation fault
indication (by default) or inverter connected
to the grid (optional).
PROTECTIONS
Reverse polarity.
Overvoltages at the AC
output with type 3
surge arresters.
Output short circuits
and overloads.
Insulation failures.
Anti-islanding with
automatic shutdown.
EFFICIENCY
INGECON® SUN 10TL
Vdc = 330 V
0
75
83
95
85
78
100
98
93
88
90
80
2 31 4 5 76 8 9 10
Power (kW)
Effi
cie
ncy
(%)
47
0
180
360
L
NOptional
PV input
AC output
for grid
connection
Inverter
Filt
er
23
On-g
rid
PV in
vert
ers
INGECON® SUN Lite transformerless
Notes: (1) Depending on the type of installation and geographical location (2) Must not be exceeded under any circumstances. Consider the voltage increase of the ‘Voc’ at low
temperatures (3) AC Power for 45ºC ambient temperature (4) Voltage confi gurable through the display (5) Consumption from PV fi eld.
Compliance with standards: EN50438, EN62109-1, EN62109-2, EN61000-6-2, EN61000-6-3, RD1699/2011, P.O.12.3, VDE-AR-N4105, CEI 11-20 V1, CEI 0-21, Allegato 70 TERNA, CEI 0-16 Ed. III, VDE0126-1-1, G83/1-1,
G83/2, AS4777.2, AS4777.3, AS3100.
6TL 7.5TL 8.2TL 8.6TL 10TL
Input (DC)Recommended PV array power range(1) 6.3 - 7 kWp 8.7 - 10.3 kWp 9.5 - 11.2 kWp 10 - 11.8 kWp 11.6 - 13.7 kWp
Voltage range MPP 190 - 450 V 215 - 450 V 235 - 450 V 245 - 450 V 300 - 450 V
Voltage range DC(2) 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V
Maximum current DC 33 A 35 A 35 A 35 A 35 A
DC inputs 4 4 4 4 4
MPPT 1 1 1 1 1
Output (AC)Rated power AC(3) 6 kW 7.5 kW 8.2 kW 8.6 kW 10 kW
Maximum current AC 26.2 A 36.1 A 36.1 A 36.1 A 36.1 A
Rated voltage AC 230 / 240 V 208 / 230 / 240 / 277 V (4) 230 / 240 / 277 V (4) 240 / 277 V (4) 277 V
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine 1 1 1 1 1
Phi Cosine adjustable Yes. Smax=6 kVA Yes. Smax=7.5 kVA Yes. Smax=8.2 kVA Yes. Smax=8.6 kVA Yes. Smax=10 kVA
THD <3% <3% <3% <3% <3%
Effi ciencyMaximum effi ciency 97% 97.5% 97.6% 97.65% 98%
Euroeffi ciency 96.1% 96.5% 96.55% 96.6% 96.8%
General InformationAir cooling 90 m3/h 90 m3/h 90 m3/h 90 m3/h 90 m3/h
Stand-by consumption(5) <10 W <10 W <10 W <10 W <10 W
Consumption at night 0 W 0 W 0 W 0 W 0 W
Ambient temperature -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95%
Protection class IP65 IP65 IP65 IP65 IP65
2.5TL 3TL 3.3TL 3.68TL 4.6TL 5TL
Input (DC)
Recommended PV array power range(1) 2.8 - 3.3 kWp 3.2 - 4 kWp 3.8 - 4.3 kWp 3.9 - 4.8 kWp 5.2 - 6 kWp 5.7 - 6.5 kWp
Voltage range MPP 160 - 450 V 195 - 450 V 155 - 450 V 175 - 450 V 145 - 450 V 160 - 450 V
Voltage range DC(2) 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V
Maximum current DC 17 A 17 A 22 A 22 A 33 A 33 A
DC inputs 3 3 3 3 4 4
MPPT 1 1 1 1 1 1
Output (AC)Rated power AC(3) 2.7 kW 3 kW 3.63 kW 3.68 kW 4.6 kW 5.5 kW
Maximum current AC 13 A 13.5 A 17 A 17 A 24.2 A 26.2 A
Rated voltage AC 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V 230 / 240 V
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine 1 1 1 1 1 1
Phi Cosine adjustable Yes. Smax=2.7 kVA Yes. Smax=3 kVA Yes. Smax=3.63 kVA Yes. Smax=3.68 kVA Yes. Smax=5 kVA Yes. Smax=5.5 kVA
THD <3% <3% <3% <3% <3% <3%
Effi ciencyMaximum effi ciency 96.6% 96.6% 96.8% 96.8% 97% 97%
Euroeffi ciency 95% 95.1% 95.2% 95.2% 96% 96.1%
General InformationAir cooling 30 m3/h 30 m3/h 45 m3/h 45 m3/h 90 m3/h 90 m3/h
Stand-by consumption(5) <10 W <10 W <10 W <10 W <10 W <10 W
Consumption at night 0 W 0 W 0 W 0 W 0 W 0 W
Ambient temperature -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95%
Protection class IP65 IP65 IP65 IP65 IP65 IP65
24
PROTECTIONS
OPTIONAL ACCESSORIES
Transformerless
Maximum effi ciency with three independent MPPT inputsPower conversion stage comprising three
independent power modules with an
advanced maximum power point tracker
system (MPPT).
Easy to installFast-on connectors. Manual disconnection
from the grid.
Robust designStainless steel housing for indoor and
outdoor installation (IP65). Able to
withstand extreme temperatures.
Easy to maintainInternal datalogger for up to 3 months data
storage. Control from either a remote PC
or on-site from the inverter front key pad.
Status and alarm LED indicators. LCD
Screen. Useful life of more than 20 years.
Software includedIncluded at no extra cost are the
INGECON® SUN Manager, INGECON® SUN
Monitor and its iSun Monitor smartphone
version for monitoring and recording the
inverter data over the internet. It also
includes RS-485 communications.
Standard 5 year warranty, extendable for up to 25 years
Three phase inverter for medium sized industrial roofs and for plants with solar tracking systems
Reverse polarity.
Input and output overvoltages with
type 3 surge arrester monitoring.
Output short-circuits and
overloads.
Insulation failures.
Anti-islanding with automatic
disconnection.
DC breaker.
Comunicación entre inversores mediante
Ethernet, Bluetooth or RS-485.
GSM/GPRS remote communication.
Additional type 2 surge arrester to
protect against overvoltage at the
AC output.
Potential free contact, factory set
to indicate an insulation failure or,
optionally, that the inverter is connected
to the grid.
10TL / 12.5TL / 15TL / 18TL
0
75
83
95
85
78
100
98
93
88
90
80
6 7.53 4.51.5 9 10.5 13.512 15 16.5 18
Power (kW)
Effi
cie
ncy
(%)
EFFICIENCY
INGECON® SUN 18TL
Vdc = 330 V
25
On-g
rid
PV in
vert
ers
INGECON® SUN Smart transformerless
Notes: (1) Depending on the type of installation and geographical location (2) Must not be exceeded under any circumstances. Consider the voltage increase of the ‘VOC’ at low temperatures (3) AC Power for 40ºC ambient temperature (4) Voltage phase to phase neutral required (5) For Pout>25% of the rated power (6) Consumption from PV fi eld.
Compliance with standards: CE, IEC61000-6-2, IEC61000-6-3, EN50178, RD1699/2011, P.O.12.3, VDE-AR-N-4105, VDE0126-1-1, CEI 11-20 V1, CEI 0-21, Allegato 70 TERNA, CEI 0-16
Ed. III, Arrêté 23-04-2008, G83/1-1, G83/2, G59/2.
Size and weight (mm)
66
8
280
644
10TL56 kg.
12.5TL / 15TL / 18TL65 kg.
Optional
Inverter
Filt
er
Optional
MPP1
MPP2
MPP3
L1
L2
L3
N N
L3
L2
L1
PV input
PV input
PV input
AC output for
grid connection
10TL 12.5TL 15TL 18TL
Input (DC)
Recommended PV array power range(1) 11.4 - 12.9 kWp 14.25 - 16.25 kWp 17.1 - 19.5 kWp 18.9 - 21 kWp
Voltage range MPP 155 - 450 V 145 - 450 V 160 - 450 V 190 - 450 V
Voltage range DC(2) 125 - 550 V 125 - 550 V 125 - 550 V 125 - 550 V
Maximum current DC (MPPT) 22 A 33 A 33 A 33 A
DC inputs 12 12 12 12
MPPT 3 3 3 3
Output (AC)Rated power AC(3) 11 kW 13.8 kW 16.5 kW 18 kW
Maximum current AC 17 A 24.2 A 25.5 A 26.2 A
Rated voltage AC(4) 400 V 400 V 400 V 400 V
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(5) 1 1 1 1
Phi Cosine adjustable Yes. Smax=11 kVA Yes. Smax=13.8 kVA Yes. Smax=6.5 kVA Yes. Smax=18 kVA
THD(5) <3% <3% <3% <3%
Effi ciencyMaximum effi ciency 96.8% 97% 97% 97%
Euroeffi ciency 95.2% 96.1% 96.1% 96.1%
General InformationAir cooling 234 m3/h 234 m3/h 234 m3/h 234 m3/h
Stand-by consumption(6) <30 W <30 W <30 W <30 W
Consumption at night 0 W 0 W 0 W 0 W
Ambient temperature -20ºC to +70°C -20ºC to +70°C -20ºC to +70°C -20ºC to +70°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95% 0 - 95%
Protection class IP65 IP65 IP65 IP65
Smart TL
26
PROTECTIONS
OPTIONAL ACCESSORIES
Maximum effi ciencyAdvanced maximum power point tracker
system (MPPT).
Easy to installQuick connectors. Manual disconnection
from the grid.
Easy to maintain Electronics block is easily replaceable from outside. Internal datalogger for up to 3 months data storage. Control from either a remote PC or on-site from the inverter front key pad. Status and alarm LED indicators. LCD Screen. Useful life of more
than 20 years.
Robust designStainless steel housing for indoor and outdoor installation (IP54). Able to withstand extreme temperatures.
Standard 5 year warranty, extendable for up to 25 years
Three phase inverter for medium sized industrial roofs and for plants with solar tracking systems
Transformer for galvanic isolation between DC
and AC.
Protection class IP54 (protection class IP65
conversion block).
Simple installation.
Easy maintenance thanks to removable block of
power conversion and built-in diagnostics.
LCD display integrated graphics.
Integrated data logger for storing data up to 3 months.
Ingecon® Sun Manager software for parameter
display and data recording system.
Display of system data via the web portal
Ingecon® Web Monitor.
Compliant with the main guidelines for low and
medium voltage.
DC load break.
Surge Protection DC and AC Class II.
Grounding Kit Positive / Negative.
AC circuit breaker (only for models 20, 25, 30)
Inter-inverter communication via RS485, Ethernet or
Bluetooth.
Card Ethernet or GSM / GPRS modem for remote
communication.
Interface module RS485 for communication with local PC.
Analog Input Board for the acquisition of signals from
environmental sensors.
Control of communication Ingecon® Sun ComBox.
10 / 12.5 / 15 / 20 / 25 / 30
With transformer
Power (kW)
0
50
80
65
95
55
85
70
100
60
90
75
5 10 15 20 25 30
Effi
cie
ncy
(%)
EFFICIENCY
INGECON® SUN 30
Vdc = 450 V
27
On-g
rid
PV in
vert
ers
+
-
+++
---
++
--
INGECON® SUN Smart with transformer
Notes: (1) Depending on the type of installation and geographical location (2) Must not be exceeded under any circumstances. Consider the voltage increase of the ‘VOC’ at low temperatures (3) AC Power for 40ºC ambient temperature. For each ºC of increase, the output power will be reduced at the rate of 1.8% (4) For Pout>25% of the rated power (5) For Pout>25% of the rated
power and voltage in accordance with IEC 61000-3-4 (6) Consumption from PV fi eld.
Size and weight (mm)
L1
L2
L3
N
InverterTransformer
Optional Optional Optional
Optional
Filt
er AC output for
grid connection
PV input
545 500
1,1
50
1,2
70
550 705
10 / 12,5192 kg.
15242 kg.
20 / 25 / 30323.5 kg.
Compliance with standards: CE, IEC61000-6-2, IEC61000-6-3, EN50178, RD1699/2011, P.O.12.3, VDE-AR-N-4105, VDE0126-1-1, CEI 11-20 V1, CEI 0-21, Allegato 70 TERNA, CEI
0-16 Ed. III, Arrêté 23-04-2008, MV Guideline BDEW, G83/1-1, G83/2, G59/2.
10 12.5 15 20 25 30
Input (DC)
Recommended PV array power range(1) 11 - 13 kWp 13 - 16 kWp 16 - 20 kWp 21 - 26 kWp 26 - 33 kWp 31 - 39 kWp
Voltage range MPP 405 - 750 V 405 - 750 V 405 - 750 V 405 - 750 V 405 - 750 V 405 - 750 V
Maximum voltage DC(2) 900 V 900 V 900 V 900 V 900 V 900 V
Maximum current DC 26 A 32 A 39 A 52 A 65 A 78 A
DC inputs 8 8 8 1 1 1
MPPT 1 1 1 1 1 1
Output (AC)Rated power AC(3) 11 kW 13 kW 16 kW 22 kW 27,5 kW 33 kW
Maximum current AC 19 A 22 A 23 A 37 A 50 A 50 A
Rated voltage AC 400 V 400 V 400 V 400 V 400 V 400 V
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(4) 1 1 1 1 1 1
Phi Cosine adjustable Yes. Smax=11 kVA Yes. Smax=13 kVA Yes. Smax=16 kVA Yes. Smax=22 kVA Yes. Smax=27.5 kVA Yes. Smax=33 kVA
THD(5) <3% <3% <3% <3% <3% <3%
Effi ciencyMaximum effi ciency 94.9% 94.9% 94.9% 96.1% 96.1% 96.1%
Euroeffi ciency 93.3% 93.5% 93.8% 94.5% 94.9% 95.2%
General InformationAir cooling 433 m3/h 433 m3/h 433 m3/h 674 m3/h 674 m3/h 674 m3/h
Stand-by consumption(6) 30 W 30 W 30 W 30 W 30 W 30 W
Consumption at night 1 W <5 W 1 W 1 W 1 W 1 W
Ambient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95%
Protection class IP54 IP54 IP54 IP54 IP54 IP54
Smart
28
Maximum effi ciency at high temperaturesAdvanced maximum power point tracker
system (MPPT). Low voltage ride through
capability, active power control and
reactive power control. Suitable for medium
voltage installations.
Easy to installNo additional items are required.
Manual disconnection from the grid.
Complete electrical protection equipment
supplied as standard.
Easy to maintainInternal datalogger for up to 3 months data
storage. Control from either a remote PC
or on-site from the inverter front key pad.
Status and alarm LED indicators. LCD
Screen. Useful life of more than 20 years.
Standard 5 year warranty, extendable for up to 25 years
Three phase inverter for medium and large power outputs on-roof applications and also for ground-based multi-megawatt applications
50 / 60 / 70 / 80 / 90 / 100
With transformer
50
80
65
95
55
85
70
100
60
90
75
0 10 3020 5040 7060 80 90 100
Power (kW)
Effi
cie
ncy
(%)
EFFICIENCY
INGECON® SUN 100
Vdc = 450 V
PROTECTIONS
OPTIONAL ACCESSORIES
Transformer for galvanic isolation between DC and AC.
Maximum effi ciency of 97.5%.
Complete with standard equipment of DC and AC
electrical protections.
Simple installation.
Maintenance simplifi ed by blocking power
conversion removable and built-in diagnostics.
LCD display integrated graphics.
Integrated data logger for storing data up to 3 months.
Ingecon® Sun Manager software for parameter
display and data recording system.
Display of system data via the web portal
Ingecon® Web Monitor.
Complies with the main guidelines for low and
medium voltage.
Kit LVFRT insensitivity to voltage dips.
Supply Kit Night.
Grounding Kit Positive / Negative.
Inter-inverter communication via RS485, Ethernet or
Bluetooth.
Card Ethernet or GSM / GPRS modem for remote
communication.
Interface module RS485 for communication with local PC
Analog Input Board for the acquisition of signals from
environmental sensors.
Control of communication Ingecon® Sun ComBox.
Monitoring of current PV array string with Ingecon®
Sun String Control.
29
On-g
rid
PV in
vert
ers
INGECON® SUN Power with transformer
Notes: (1) Depending on the type of installation and geographical location (2) Must not be exceeded under any circumstances. Consider the voltage increase of the ‘VOC’ at low temperatures (3) AC Power for 40ºC ambient temperature. For each ºC of increase, the output power will be reduced at the rate of 1.8% (4) For Pout>25% of the rated power (5) For Pout>25% of the rated
power and voltage in accordance with IEC 61000-3-4 (6) Consumption from PV fi eld.
Size and weight (mm)
Compliance with standards: CE, IEC61000-6-2, IEC61000-6-4, EN50178, RD1699/2011, P.O.12.3, VDE-AR-N-4105, VDE0126-1-1, CEI 11-20 V1, CEI 0-21, Allegato 70 TERNA, CEI 0-16
Ed. III, Arrêté 23-04-2008, MV Guideline BDEW, G59/2.
50 / 60900 kg.
70 / 801,026 kg.
90 / 1001,162 kg.
1,7
61
1,031 877
50 60 70 80 90 100
Input (DC)
Recommended PV array power range(1) 52 - 65 kWp 63 - 78 kWp 73 - 91 kWp 83 - 104 kWp 93 - 117 kWp 104 - 130 kWp
Voltage range MPP 405 - 750 V 405 - 750 V 405 - 750 V 405 - 750 V 405 - 750 V 405 - 750 V
Maximum voltage DC(2) 900 V 900 V 900 V 900 V 900 V 900 V
Maximum current DC 130 A 156 A 182 A 208 A 234 A 260 A
DC inputs 4 4 4 4 4 4
MPPT 1 1 1 1 1 1
Output (AC)Rated power AC(3) 55 kW 66 kW 77 kW 88 kW 99 kW 110 kW
Maximum current AC 93 A 118 A 131 A 156 A 161 A 161 A
Rated voltage AC 400 V 400 V 400 V 400 V 400 V 400 V
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(4) 1 1 1 1 1 1
Phi Cosine adjustable Yes. Smax=55 kVA Yes. Smax=66 kVA Yes. Smax=77 kVA Yes. Smax=88 kVA Yes. Smax=99 kVA Yes. Smax=110 kVA
THD(5) <3% <3% <3% <3% <3% <3%
Effi ciencyMaximum effi ciency 96.3% 96.4% 97.2% 97.5% 96.9% 96.8%
Euroeffi ciency 94.3% 94.7% 96.1% 96.2% 95.8% 95.7%
General InformationAir cooling 2,600 m3/h 2,600 m3/h 2,600 m3/h 2,600 m3/h 2,600 m3/h 2,600 m3/h
Stand-by consumption(6) 30 W 30 W 30 W 30 W 30 W 30 W
Consumption at night 1 W 1 W 1 W 1 W 1 W 1 W
Ambient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 IP20 IP20 IP20 IP20 IP20
Power
+
-
InverterTransformer
L1
L2
L3
PV input AC output for
grid connectionFilt
er
30
Maximum effi ciency at high temperaturesAdvanced maximum power point tracker
system (MPPT). Low voltage ride through
capability, active power control and
reactive power control. Suitable for medium
voltage installations.
Easy to installNo additional items are required.
Manual disconnection from the grid.
Complete electrical protection equipment
supplied as standard.
Easy to maintainInternal datalogger for up to 3 months data
storage. Control from either a remote PC
or on-site from the inverter front key pad.
Status and alarm LED indicators. LCD
Screen. Useful life of more than 20 years.
Standard 5 year warranty, extendable for up to 25 years
Transformerless
Three phase inverter for medium and large power outputs on-roof applications and also for ground-based multi-megawatt applications
100 113 125
75
90
85
100
80
95
0 13 3825 6350 8875
Power (kW)
Effi
cie
ncy
(%)
EFFICIENCY
INGECON® SUN 125TL
Vdc = 450 V
110TL B220 / 140TL B220 / 175TL B275 / 190TL B300 / 200TL B320 220TL B345 / 230TL B360 / 250TL B400
PROTECTIONS
OPTIONAL ACCESSORIES
Maximum effi ciency of 98.8%.
System “Long Life System” Ingeteam to reduce
parasitic inductances in the IGBT components and
polypropylene capacitors for a period of useful life of
the device more than 20 years.
Reactive power control up to + / - 48.43 of Pnom.
Complete with standard equipment of DC and AC
electrical protections.
Simple installation.
Easy maintenance thanks to removable block of power
conversion and built-in diagnostics.
LCD display integrated graphics.
Integrated data logger for storing data up to 3 months.
Ingecon® Sun Manager software for parameter display
and data recording system.
Display of system data via the web portal Ingecon®
Web Monitor.
Compliant with the main directives for medium and
high voltage.
Kit LVFRT insensitivity to voltage dips.
Supply Kit Night.
Grounding Kit Positive / Negative.
Option 1000 V DC.
Inter-inverter communication via RS485, Ethernet or
Bluetooth.
Card Ethernet or GSM / GPRS modem for remote
communication.
Interface module RS485 for communication with local PC
Analog Input Board for the acquisition of signals from
environmental sensors.
Control of communication Ingecon® Sun ComBox.
Monitoring of current PV array string with Ingecon®
Sun String Control.
31
On-g
rid
PV in
vert
ers
INGECON® SUN Power transformerless
110TL B220560 kg.
140TL B220 / 175TL B275 / 190TL B300 / 200TL B320 220TL B345 / 230TL B360 / 250TL B400600 kg.1
,761
1,031 877
Size and weight (mm)
110TL B220 140TL B220 175TL B275 190TL B300 200TL B320 220TL B345 230TL B360 250TL B400
Input (DC)
Recommended PV array
power range(1)
103 - 130 kWp 141 - 163 kWp 172 - 195 kWp 193 - 224 kWp 205 - 238 kWp 224 - 260 kWp 233 - 273 kWp 254 - 295 kWp
Voltage range MPP 405 - 820 V 405 - 820 V 405 - 820 V 437 - 820 V 468 - 820 V 502 - 820 V 524 - 820 V 578 - 820 V
Maximum voltage DC(2) 1,000 V 1,000 V 1,000 V 1,000 V 1,000 V 1,000 V 1,000 V 1,000 V
Maximum current DC 400 A 400 A 400 A 400 A 400 A 400 A 400 A 450 A
DC inputs 4 4 4 4 4 4 4 4
MPPT 1 1 1 1 1 1 1 1
Output (AC)Rated power AC(3) 110 kW 137 kW 173 kW 189,2 kW 201,3 kW 220 kW 229 kW 250 kW
Maximum current AC 326 A 368 A 368 A 368 A 368 A 368 A 368 A 368 A
Rated voltage AC 220 V
IT System
220 V
IT System
275 V
IT System
300 V
IT System
320 V
IT System
345 V
IT System
360 V
IT System
400 V
IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(4) 1 1 1 1 1 1 1 1
Phi Cosine adjustable Yes.
Smax=110 kVA
Yes.
Smax=137 kVA
Yes.
Smax=173 kVA
Yes.
Smax=189.2 kVA
Yes.
Smax=201.3 kVA
Yes.
Smax=220 kVA
Yes.
Smax=229 kVA
Yes.
Smax=250 kVA
THD(5) <3% <3% <3% <3% <3% <3% <3% <3%
Effi ciencyMaximum effi ciency 98.4% 98.1% 98.5% 98.7% 98.7% 98.8% 98.8% 98.9%
Euroeffi ciency 97.5% 97.7% 98.2% 98.4% 98.4% 98.5% 98.6% 98.6%
General InformationAir cooling 2,600 m3/h 2,600 m3/h 2,600 m3/h 2,600 m3/h 2,600 m3/h 2,600 m3/h 2,600 m3/h 2,600 m3/h
Stand-by consumption(6)
30 W 30 W 30 W 30 W 30 W 30 W 30 W 30 W
Consumption at night 1 W <5 W <5 W <5 W <5 W <5 W <5 W <5 W
Ambient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity
(non-condensing)0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20
Power TL
Notes: (1) Depending on the type of installation and geographical location (2) Never exceed 1,000 V. Consider the voltage increase of the ‘VOC’ at low temperatures (3) AC Power for 40ºC
ambient temperature. For each ºC of increase, the output power will be reduced at the rate of 1.8% (4) For Pout>25% of the rated power (5) For Pout>25% of the rated power and voltage in
accordance with IEC 61000-3-4 (6) Consumption from PV fi eld.
Compliance with standards: CE, IEC61000-6-2, IEC61000-6-4, EN50178, RD1699/2011, P.O.12.3, VDE-AR-N-4105, VDE0126-1-1, CEI 11-20 V1, CEI 0-21, Allegato 70 TERNA, CEI
0-16 Ed. III, Arrêté 23-04-2008, MV Guideline BDEW, G59/2.
Inverter
L1
L2
L3
PV input
AC output for
connection to
a private LV network
AC output for
connection to a
MV network
Filt
er
32
The INGECON® SUN PowerMax central inverters for multi-megawatt plants with a direct connection to a
medium voltage transformer, are now more powerful and effi cient than ever. They can reach a maximum
power output of 1 MW, with effi ciency levels of up to 98.8%
Modular transformerless central inverters from 275 to 1019 kW
Enhanced functionalityThe new INGECON® SUN PowerMax range features
a revamped, improved enclosure which, together with
its innovative air cooling system, makes its possible to
increase the ambient operating temperature to deliver its
rated power up to 45 ºC.
Long-lasting designThe inverters have been designed to guarantee a service
life of more than 20 years, as demonstrated by the stress
tests they are subjected to.
Maximum effi ciency valuesThrough the use of innovative electronic conversion
topologies, effi ciency values of up to 98.8% can be
achieved. Furthermore, an advanced MPPT algorithm
makes it possible to harness the maximum energy from the
PV array at all times, even in diffi cult situations, such as
scattered clouds and partial shading.
A complete range or equipment for all types of projectsThe PowerMax inverters are fully adaptable to all types of
engineering projects. This is made possible thanks to their
wide range of power outputs (from 275 to 1019 kW) and to
the variety of possible confi gurations.
Grid supportThe INGECON® SUN PowerMax family has been designed
to comply with the grid connection requirements in
different countries, contributing to the quality and stability
of the electricity system. Theses inverters therefore
feature a low voltage ride-through capability, and can
deliver reactive power and control the active power
delivered to the grid.
Ease of maintenanceEasily replaceable modular power blocks for shorter
maintenance times.
Also available in an Outdoor versionThe inverter is available in two versions: Indoor (IP20) and
Outdoor (IP54). These inverters can provide a maximum
power output up to an ambient temperature of 45ºC.
Its innovative ventilation system, with a uniform internal
circulation of fresh air, ensures that these inverters are
able to withstand extreme ambient conditions. In the
Outdoor version, the fresh air intake is made from the top,
thereby reducing the infl ux of particles and the obstruction
of the fi lters.
Easy to operateThe INGECON® SUN PowerMax inverters feature an
LCD screen for the simple and convenient monitoring of
the inverter status and a range of internal variables. The
display also includes a number of LEDs to show the inverter
operating status with warning lights to indicate any incidents.
All this helps to simplify and facilitate maintenance tasks.
Monitoring and communicationFor monitoring the internal operating variables (alarms, real
time production, etc) in addition to the historical production
data through a number of media such as RS-485, Ethernet,
GSM/GPRS and Bluetooth. The following applications
are included at no extra cost: INGECON® SUN Manager,
INGECON® SUN Monitor and its iSun Monitor smartphone
version for monitoring and recording the inverter data over
the internet.
33
On-g
rid
PV in
vert
ers
Multi-MPPT central inverters Transformerless
The central multi-MPPT inverter model, in
any of its confi gurations, can be supplied
with either two, three or four independent
power blocks. Each of these modules has its
own maximum power point tracking system
(MPPT), delivering optimum power output
levels in each specifi c case.
These inverters operate in a wide output voltage
range: 220, 275, 300, 320, 345, 360 and 400
Vac. It is also possible to connect up to two
inverters, with four power blocks each, to the
same medium voltage transformer winding.
Versions available:
Indoor inverters with integrated
DCAC cabinet.
Indoor inverters with DC cabinet.
Outdoor inverters with integrated
DCAC cabinet.
Symmetrical indoor inverters, with the
connection cabinet on the opposite side, to
make it possible to install two inverters facing
each other, with a common power supply point.
PROTECTIONS
For each power module:
Reverse polarity.
Short-circuits and overloads at the
output.
Anti-islanding system with automatic
disconnection.
DC load breaker with door control.
DC insulation monitor.
3 pairs of DC fuse-holders per power
block (only for the DCAC inverters).
DC and AC surge arresters, type 2.
DC contactor to automatically
disconnect the inverter from the
PV array.
OPTIONAL ACCESSORIES
AC thermal magnetic breaker with door control
(only for the DCAC inverters).
AC thermal magnetic breaker monitoring kit.
Inter-inverter communication via RS-485,
Ethernet or Bluetooth.
Insulation failure AC.
Kit for operating at ambient temperatures of
down to -30ºC.
Monitoring of the group currents at the DC
input (only for the DCAC inverters).
Remote tripping of the AC protection
(only for the DCAC inverters).
DC fuses (only for the DCAC inverters).
Wattmeter on the AC side
(only for the DCAC inverters).
Voltage ride through kit.
Extendable up to 4 pairs of fuse holders per
power block.
Central inverters with a Master-Slave confi gurationTransformerless
The central inverter with the Master-Slave
confi guration, in any of its confi gurations,
is equipped with two to four power blocks
connected in parallel to the same PV
generator and to the same medium voltage
transformer. Thanks to a sophisticated control
algorithm, this equipment can guarantee
maximum effi ciency through the selective
operation of its power blocks, based on the PV
power available. This maximizes the effi ciency
and service life of the equipment. In this
way, in periods of low irradiance, it is able to
increase performance by up to 1.8 points.
These inverters operate at a wide range of
output voltages: 220, 275,300, 320, 345 and
360 Vac.
Versions available:
Indoor inverters with integrated
DCAC cabinet.
Indoor inverters with DC cabinet.
Outdoor inverters with integrated
DCAC cabinet.
Symmetrical indoor inverters, with the
connection cabinet on the opposite side, to
facilitate installing two facing inverters with a
common power supply point.
OPTIONAL ACCESSORIES
AC thermal magnetic breaker
(only for the DCAC inverters).
Motorization kit for the AC thermal magnetic
breaker.
Inter-inverter communication via RS-485,
Ethernet, Bluetooth or GSM/GPRS.
Insulation failure AC.
Earthing kit.
Kit for operating at an ambient temperature of
up to -30ºC.
DC fuses.
Blown fuse sensor at the DC input.
Monitoring of the group currents at the DC
input (only for the DCAC inverters).
Remote tripping of the AC protection
(only for the DCAC inverters).
Wattmeter on the AC side.
(only for the DCAC inverters).
Voltage ride through kit.
Extendable up to 16 fuse holders per inverter.Enhanced performance.
In the event of the failure of one of the
blocks, the power is then distributed
amongst the remaining blocks.
Lightweight spares, for shorter
delivery times.
Permite aterrar el campo fotovoltaico.
PROTECTIONS
DC reverse polarity.
Short-circuits and overloads at
the output.
Anti-islanding with automatic
disconnection.
Insulation failure DC.
DC load breaker.
12 pairs of fuse-holders for inverters
with 3 and 4 power blocks, and 8
pairs of fuse-holders for inverters
with 2 power blocks.
Lightning induced class 2 DC and AC
surge arrestors.
DC contactor to automatically
disconnect the inverter from the
PV array.
ADVANTAGES OF THE MASTER-SLAVE VERSION
34
Master-Slave confi guration
Indoor / Outdoor
DC and AC supplies in the same cabinetThe input and output lines are
integrated into the same cabinet,
facilitating maintenance and repair
work.
Central inverters with a Master-Slave confi guration and integrated DCAC cabinet
Available in indoor and outdoor versionsThese Master-Slave central inverters
feature an innovative ventilation system
for the internal circulation of fresh air.
Furthermore, the selection of casings
makes these inverters suitable for indoor
(IP20) and outdoor (IP54) installation.
PowerMax X DCAC
Maximum protectionThese three phase inverters are
equipped with a motorized DC load
break switch to decouple the PV
generator from the inverter. Optionally,
the inverters can be supplied with an
AC thermal magnetic breaker with door
control, in addition to fuses, grounding
kit and input current monitoring.
Size and weight (mm)
4 blocks Indoor2,500 kg.
3 blocks Indoor1,900 kg.
2 blocks Indoor1,300 kg.
2,0
40
2,310
925
2,0
40
2,910
925
2,0
40
3,510
925
2,1
40
2,310
1,000
2 blocks Outdoor1,500 kg.
3 blocks Outdoor2,050 kg.
4 blocks Outdoor2,700 kg.
2,1
40
3,510
1,000
2,1
40
2,910
1,000
M
+16...
+3
+2
+1
-1
-2
-3
...
-16
Inverter
Filt
er
InverterOptional
Filt
er
AC output for
connection to a
MV network
L1L2L3
Optional
35
On-g
rid
PV in
vert
ers
INGECON® SUN PowerMax Master-Slave
Optimised space and investmentThis model requires less space as the
AC supply is not grouped together.
This is a versatile solution, which is
particularly advantageous for medium
voltage transformer substations with
two inverters and limited space. In
Central inverters with a Master-Slave confi guration and DC cabinet
this way, investment is optimised by
constructing enclosures housing a
number of inverters.
Integrated protectionsThe Master-Slave INGECON® SUN
PowerMax DC inverters are supplied
with DC fuse-holders as standard and,
optionally, they can come with DC
fuses and a grounding kit. In addition,
they have a motorized DC load breaker
to decouple the PV generator from
the inverter.
PowerMax X DC
Size and weight (mm)
4 blocks Indoor2,100 kg.
3 blocks Indoor1,500 kg.
2 blocks Indoor900 kg.
2,0
40
1,910
925
2,0
40
2,510
925
2,0
40
3,110
925
M
Inverter
Inverter
Filt
er
Filt
er
+16
...
+3
+2
+1
-1
-2
-3
...
-16
AC output for
connection to a
MV network
L1
L1
L2
L2
L3
L3
Optional
36
275TL X220 410TL X220 550TL X220
Input (DC)
Recommended PV array power range(1) 283 - 325 kWp 424 - 488 kWp 566 - 650 kWp
Voltage Range MPP 405 - 820 V 405 - 820 V 405 - 820 V
Maximum voltage DC(2) 1,000 V 1,000 V 1,000 V
Maximum current DC 900 A 1,350 A 1,800 A
Nº DC inputs with fuse holders 8 12 (extendable up to 16) 12 (extendable up to 16)
DC fuse dimensions 125 A/1,000 V to 250 A/1,000 V fuses, maximum current from 100 to 200 A for positive and negative poles
Type of connection Connection to fuse-holder copper bars. Cable entry from the ground through D40 cable glands (max. cable diameter: 40 mm)
Power blocks 2 3 4
MPPT 1 1 1
Current at each input 100 to 200 A 100 to 200 A 100 to 200 A
Input protectionsOvervoltage protections DC surge arresters, type 2 (for each power stage)
DC breaker Motorized DC load breaker
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(3) 275 kW 412 kW 550 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 220 V IT System 220 V IT System 220 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(4) 1 1 1
Phi Cosine adjustable Yes. Smax=275 kVA Yes. Smax=412 kVA Yes. Smax=550 kVA
THD (Total Harmonic Distortion)(5) <3% <3% <3%
Output protectionsOvervoltage protections AC surge arresters, type 2
AC breaker Optional AC thermal magnetic breaker with door control, remote trip or motorized (only DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.1% 98.1% 98.1%
Euroeffi ciency 97.9% 97.9% 97.9%
CEC 97.4% 97.4% 97.4%
Stand-by consumptiony(6) 60 W 90 W 120 W
Consumption at night 60 W 90 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(7) 3,000 m 3,000 m 3,000 m
Cooling system Air forced with temperature control (230 V phase + neutral power supply)
Air fl ow 2,670 m3/h (fans: 1,230 W) 4,640 m3/h (fans: 2,050 W) 5,340 m3/h (fans: 2,460 W)
Acoustic emission < 55 dB (A) at 4 m. and < 67 dB (A) at 1 m. with fans working at maximum power
Certifi cation CE
EMC and security standards EN 50178, EN 62109-1, EN 62109-2, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 0-16, CEI 11-20, CEI 11-20 V1, CEI 0-21, Allegato A70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA,IEEE 1547, Arrêté 23-04-08, G59/2, South African Grid Code Draft Rev.0
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Consider the voltage increase of the ‘VOC’ at low temperatures (3) AC Power for 45ºC ambient temperature. For each ºC of increase, the output
power will be reduced at the rate of 1.8% (4) For Pout>25% of the rated power (5)
For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (6) Over 1,000 m temperature for rated power (45 ºC) is reduced at the rate of 4.5 ºC
for each 1,000 m.
Effi ciency INGECON® SUN 550TL X220 Vdc = 500 V
PowerMax Master-Slave 220 Vac
Power (kW)
0 150 350250 450 550
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
50
37
On-g
rid
PV in
vert
ers
350TL X275 520TL X275 695TL X275
Input (DC)Recommended PV array power range(1) 354 - 410 kWp 531 - 650 kWp 709 - 819 kWp
Voltage Range MPP 460 - 820 V 460 - 820 V 460 - 820 V
Maximum voltage DC(2) 1,000 V 1,000 V 1,000 V
Maximum current DC 900 A 1,350 A 1,800 A
Nº DC inputs with fuse holders 8 12 (extendable up to 16) 12 (extendable up to 16)
DC fuse dimensions 125 A/1,000 V to 250 A/1,000 V fuses, maximum current from 100 to 200 A for positive and negative poles
Type of connection Connection to fuse-holder copper bars. Cable entry from the ground through D40 cable glands (max. cable diameter: 40 mm)
Power blocks 2 3 4
MPPT 1 1 1
Current at each input 100 to 200 A 100 to 200 A 100 to 200 A
Input protectionsOvervoltage protections DC surge arresters, type 2 (for each power stage)
DC breaker Motorized DC load breaker
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(3) 346 kW 519 kW 693 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 275 V IT System 275 V IT System 275 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(4) 1 1 1
Phi Cosine adjustable Yes. Smax=346 kVA Yes. Smax=519 kVA Yes. Smax=693 kVA
THD (Total Harmonic Distortion)(5) <3% <3% <3%
Output protectionsOvervoltage protections AC surge arresters, type 2
AC breaker Optional AC thermal magnetic breaker with door control, remote trip or motorized (only DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.5% 98.5% 98.5%
Euroeffi ciency 98.2% 98.3% 98.3%
CEC 97.8% 97.9% 97.8%
Stand-by consumptiony(6) 60 W 90 W 120 W
Consumption at night 60 W 90 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(7) 3,000 m 3,000 m 3,000 m
Cooling system Air forced with temperature control (230 V phase + neutral power supply)
Air fl ow 2,670 m3/h (fans: 1,230 W) 4,640 m3/h (fans: 2,050 W) 5,340 m3/h (fans: 2,460 W)
Acoustic emission < 55 dB (A) at 4 m. and < 67 dB (A) at 1 m. with fans working at maximum power
Certifi cation CE
EMC and security standards EN 50178, EN 62109-1, EN 62109-2, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 0-16, CEI 11-20, CEI 11-20 V1, CEI 0-21, Allegato A70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA, IEEE 1547, Arrêté 23-04-08, G59/2, South African Grid Code Draft Rev.0
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Consider the voltage increase of the ‘VOC’ at low temperatures (3) AC Power for 45ºC ambient temperature. For each ºC of increase, the output
power will be reduced at the rate of 1.8% (4) For Pout>25% of the rated power (5)
For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (6) Over 1,000 m temperature for rated power (45 ºC) is reduced at the rate of 4.5 ºC
for each 1,000 m.
Effi ciency INGECON® SUN 695TL X275 Vdc = 550 V
PowerMax Master-Slave 275 Vac
Power (kW)
0 300 500400 600 700
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
200100
38
380TL X300 570TL X300 760TL X300
Input (DC)Recommended PV array power range(1) 386 - 447 kWp 580 - 671 kWp 773 - 894 kWp
Voltage Range MPP 505 - 820 V 505 - 820 V 505 - 820 V
Maximum voltage DC(2) 1,000 V 1,000 V 1,000 V
Maximum current DC 900 A 1,200 A 1,800 A
Nº DC inputs with fuse holders 8 12 (extendable up to 16) 12 (extendable up to 16)
DC fuse dimensions 125 A/1,000 V to 250 A/1,000 V fuses, maximum current from 100 to 200 A for positive and negative poles
Type of connection Connection to fuse-holder copper bars. Cable entry from the ground through D40 cable glands (max. cable diameter: 40 mm)
Power blocks 2 3 4
MPPT 1 1 1
Current at each input 100 to 200 A 100 to 200 A 100 to 200 A
Input protectionsOvervoltage protections DC surge arresters, type 2 (for each power stage)
DC breaker Motorized DC load breaker
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(3) 378 kW 568 kW 757 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 300 V IT System 300 V IT System 300 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(4) 1 1 1
Phi Cosine adjustable Yes. Smax=378 kVA Yes. Smax=568 kVA Yes. Smax=757 kVA
THD (Total Harmonic Distortion)(5) <3% <3% <3%
Output protectionsOvervoltage protections AC surge arresters, type 2
AC breaker Optional AC thermal magnetic breaker with door control, remote trip or motorized (only DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.6% 98.6% 98.6%
Euroeffi ciency 98.4% 98.4% 98.4%
CEC 97.9% 97.9% 97.9%
Stand-by consumptiony(6) 60 W 90 W 120 W
Consumption at night 60 W 90 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(7) 3,000 m 3,000 m 3,000 m
Cooling system Air forced with temperature control (230 V phase + neutral power supply)
Air fl ow 2,670 m3/h (fans: 1,230 W) 4,640 m3/h (fans: 2,050 W) 5,340 m3/h (fans: 2,460 W)
Acoustic emission < 55 dB (A) at 4 m. and < 67 dB (A) at 1 m. with fans working at maximum power
Certifi cation CE
EMC and security standards EN 50178, EN 62109-1, EN 62109-2, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 0-16, CEI 11-20, CEI 11-20 V1, CEI 0-21, Allegato A70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA, IEEE 1547, Arrêté 23-04-08, G59/2, South African Grid Code Draft Rev.0
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Consider the voltage increase of the ‘VOC’ at low temperatures (3) AC Power for 45ºC ambient temperature. For each ºC of increase, the output
power will be reduced at the rate of 1.8% (4) For Pout>25% of the rated power (5)
For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (6) Over 1,000 m temperature for rated power (45 ºC) is reduced at the rate of 4.5 ºC
for each 1,000 m.
Effi ciency INGECON® SUN 760TL X300 Vdc = 550 V
PowerMax Master-Slave 300 Vac
Power (kW)
0 400 600500 700 800
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
100 200 300
39
On-g
rid
PV in
vert
ers
400TL X320 605TL X320 800TL X320
Input (DC)Recommended PV array power range(1) 409 - 475 kWp 617 - 715 kWp 819 - 949 kWp
Voltage Range MPP 540 - 820 V 540 - 820 V 540 - 820 V
Maximum voltage DC(2) 1,000 V 1,000 V 1,000 V
Maximum current DC 900 A 1,350 A 1,800 A
Nº DC inputs with fuse holders 8 12 (extendable up to 16) 12 (extendable up to 16)
DC fuse dimensions 125 A/1,000 V to 250 A/1,000 V fuses, maximum current from 100 to 200 A for positive and negative poles
Type of connection Connection to fuse-holder copper bars. Cable entry from the ground through D40 cable glands (max. cable diameter: 40 mm)
Power blocks 2 3 4
MPPT 1 1 1
Current at each input 100 to 200 A 100 to 200 A 100 to 200 A
Input protectionsOvervoltage protections DC surge arresters, type 2 (for each power stage)
DC breaker Motorized DC load breaker
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(3) 401 kW 605 kW 803 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 320 V IT System 320 V IT System 320 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(4) 1 1 1
Phi Cosine adjustable Yes. Smax=401 kVA Yes. Smax=605 kVA Yes. Smax=803 kVA
THD (Total Harmonic Distortion)(5) <3% <3% <3%
Output protectionsOvervoltage protections AC surge arresters, type 2
AC breaker Optional AC thermal magnetic breaker with door control, remote trip or motorized (only DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.7% 98.7% 98.7%
Euroeffi ciency 98.5% 98.5% 98.5%
CEC 97.9% 97.9% 97.9%
Stand-by consumptiony(6) 60 W 90 W 120 W
Consumption at night 60 W 90 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(7) 3,000 m 3,000 m 3,000 m
Cooling system Air forced with temperature control (230 V phase + neutral power supply)
Air fl ow 2,670 m3/h (fans: 1,230 W) 4,640 m3/h (fans: 2,050 W) 5,340 m3/h (fans: 2,460 W)
Acoustic emission < 55 dB (A) at 4 m. and < 67 dB (A) at 1 m. with fans working at maximum power
Certifi cation CE
EMC and security standards EN 50178, EN 62109-1, EN 62109-2, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 0-16, CEI 11-20, CEI 11-20 V1, CEI 0-21, Allegato A70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA, IEEE 1547, Arrêté 23-04-08, G59/2, South African Grid Code Draft Rev.0
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Consider the voltage increase of the ‘VOC’ at low temperatures (3) AC Power for 45ºC ambient temperature. For each ºC of increase, the output
power will be reduced at the rate of 1.8% (4) For Pout>25% of the rated power (5)
For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (6) Over 1,000 m temperature for rated power (45 ºC) is reduced at the rate of 4.5 ºC
for each 1,000 m.
Effi ciency INGECON® SUN 800TL X320 Vdc = 550 V
PowerMax Master-Slave 320 Vac
0 400 600500 700 800
82
94
88
100
84
96
90
86
98
92
100 200 300
Power (kW)
Effi
cie
ncy
(%)
40
440TL X345 660TL X345 880TL X345
Input (DC)Recommended PV array power range(1) 448 - 520 kWp 673 - 780 kWp 896 - 1.040 kWp
Voltage Range MPP 580 - 820 V 580 - 820 V 580 - 820 V
Maximum voltage DC(2) 1,000 V 1,000 V 1,000 V
Maximum current DC 900 A 1,350 A 1,600 A
Nº DC inputs with fuse holders 8 12 (extendable up to 16) 12 (extendable up to 16)
DC fuse dimensions 125 A/1,000 V to 250 A/1,000 V fuses, maximum current from 100 to 200 A for positive and negative poles
Type of connection Connection to fuse-holder copper bars. Cable entry from the ground through D40 cable glands (max. cable diameter: 40 mm)
Power blocks 2 3 4
MPPT 1 1 1
Current at each input 100 to 200 A 100 to 200 A 100 to 200 A
Input protectionsOvervoltage protections DC surge arresters, type 2 (for each power stage)
DC breaker Motorized DC load breaker
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(3) 440 kW 660 kW 880 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 345 V IT System 345 V IT System 345 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(4) 1 1 1
Phi Cosine adjustable Yes. Smax=440 kVA Yes. Smax=660 kVA Yes. Smax=880 kVA
THD (Total Harmonic Distortion)(5) <3% <3% <3%
Output protectionsOvervoltage protections AC surge arresters, type 2
AC breaker Optional AC thermal magnetic breaker with door control, remote trip or motorized (only DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.8% 98.8% 98.8%
Euroeffi ciency 98.6% 98.6% 98.6%
CEC 98% 98% 98%
Stand-by consumptiony(6) 60 W 90 W 120 W
Consumption at night 60 W 90 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(7) 3,000 m 3,000 m 3,000 m
Cooling system Air forced with temperature control (230 V phase + neutral power supply)
Air fl ow 2,670 m3/h (fans: 1,230 W) 4,640 m3/h (fans: 2,050 W) 5,340 m3/h (fans: 2,460 W)
Acoustic emission < 55 dB (A) at 4 m. and < 67 dB (A) at 1 m. with fans working at maximum power
Certifi cation CE
EMC and security standards EN 50178, EN 62109-1, EN 62109-2, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 0-16, CEI 11-20, CEI 11-20 V1, CEI 0-21, Allegato A70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA,IEEE 1547, Arrêté 23-04-08, G59/2, South African Grid Code Draft Rev.0
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Consider the voltage increase of the ‘VOC’ at low temperatures (3) AC Power for 45ºC ambient temperature. For each ºC of increase, the output
power will be reduced at the rate of 1.8% (4) For Pout>25% of the rated power (5)
For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (6) Over 1,000 m temperature for rated power (45 ºC) is reduced at the rate of 4.5 ºC
for each 1,000 m.
Effi ciency INGECON® SUN 880TL X345 Vdc = 600 V
PowerMax Master-Slave 345 Vac
Power (kW)
0 200 600300 800 900
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
100 700500400
41
On-g
rid
PV in
vert
ers
460TL X360 690TL X360 920TL X360
Input (DC)Recommended PV array power range(1) 466 - 546 kWp 702 - 819 kWp 933 - 1,092 kWp
Voltage Range MPP 606 - 820 V 606 - 820 V 606 - 820 V
Maximum voltage DC(2) 1,000 V 1.,000 V 1,000 V
Maximum current DC 900 A 1.350 A 1,800 A
Nº DC inputs with fuse holders 8 12 (extendable up to 16) 12 (extendable up to 16)
DC fuse dimensions 125 A/1,000 V to 250 A/1,000 V fuses, maximum current from 100 to 200 A for positive and negative poles
Type of connection Connection to fuse-holder copper bars. Cable entry from the ground through D40 cable glands (max. cable diameter: 40 mm)
Power blocks 2 3 4
MPPT 1 1 1
Current at each input 100 to 200 A 100 to 200 A 100 to 200 A
Input protectionsOvervoltage protections DC surge arresters, type 2 (for each power stage)
DC breaker Motorized DC load breaker
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(3) 458 kW 688 kW 917 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 360 V IT System 360 V IT System 360 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(4) 1 1 1
Phi Cosine adjustable Yes. Smax=458 kVA Yes. Smax=688 kVA Yes. Smax=917 kVA
THD (Total Harmonic Distortion)(5) <3% <3% <3%
Output protectionsOvervoltage protections AC surge arresters, type 2
AC breaker Optional AC thermal magnetic breaker with door control, remote trip or motorized (only DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.8% 98.8% 98.8%
Euroeffi ciency 98.6% 98.7% 98.7%
CEC 98.1% 98.1% 98.1%
Stand-by consumptiony(6) 60 W 90 W 120 W
Consumption at night 60 W 90 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(7) 3,000 m 3,000 m 3,000 m
Cooling system Air forced with temperature control (230 V phase + neutral power supply)
Air fl ow 2,670 m3/h (fans: 1,230 W) 4,640 m3/h (fans: 2,050 W) 5,340 m3/h (fans: 2,460 W)
Acoustic emission < 55 dB (A) at 4 m. and < 67 dB (A) at 1 m. with fans working at maximum power
Certifi cation CE
EMC and security standards EN 50178, EN 62109-1, EN 62109-2, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 0-16, CEI 11-20, CEI 11-20 V1, CEI 0-21, Allegato A70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA,IEEE 1547, Arrêté 23-04-08, G59/2, South African Grid Code Draft Rev.0
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Consider the voltage increase of the ‘VOC’ at low temperatures (3) AC Power for 45ºC ambient temperature. For each ºC of increase, the output
power will be reduced at the rate of 1.8% (4) For Pout>25% of the rated power (5)
For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (6) Over 1,000 m temperature for rated power (45 ºC) is reduced at the rate of 4.5 ºC
for each 1,000 m.
Effi ciency INGECON® SUN 920TL X360 Vdc = 625 V
PowerMax Master-Slave 360 Vac
Power (kW)
0 300 700500 900 1000
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
800600400100 200
42
DC and AC supplies in the same cabinetThe input and output lines are
integrated into the same cabinet,
facilitating maintenance and repair
work, whilst still maintaining the
highest level of safety.
Central multi-MPPT inverters with an integrated DCAC CABINET
Available in indoor and outdoor versionsThese multi-string central inverters
can be supplied with either an indoor
(IP20) or outdoor (IP54) casing.
Maximum protectionThese three phase inverters are
equipped with a manual DC load break
PowerMax M DCAC
Inverter
Inverter
Optional
PV input
Module 1
PV input
Module 4
AC output for
connection to a
MV network
L1L2L3
switch and a DC automatic contactor
for each power block, in order to
decouple the PV generator from the
inverter. Optionally, the inverters
can be supplied with an AC thermal
magnetic breaker with door control,
in addition to fuses and current
monitoring.
Multi-MPPT transformerless
Indoor / Outdoor
Filt
er
Filt
er
Optional
Size and weight (mm)
4 blocks Indoor2,500 kg.
3 blocks Indoor1,900 kg.
2 blocks Indoor1,300 kg.
2,0
40
2,310
925
2,0
40
2,910
925
2,0
40
3,510
925
2,1
40
2,310
1,000
2 blocks Outdoor1,500 kg.
3 blocks Outdoor2,050 kg.
4 blocks Outdoor2,700 kg.
2,1
40
3,510
1,000
2,1
40
2,910
1,000
43
On-g
rid
PV in
vert
ers
Optimised space and investmentThis model requires less space as the
AC supply is not grouped together.
This is a versatile solution, which is
particularly advantageous for medium
voltage transformer substations with
two inverters and limited space.
Central multi-MPPT inverters with a DC CABINET
In this way, investment is optimised
by constructing enclosures housing a
number of inverters.
Integrated protectionsThe INGECON® SUN PowerMax DC
multi-string inverters are supplied with
PowerMax M DC
Inverter
Inverter
PV input
Module 1
PV input
Module 4
AC output for
connection to a
private LV network
AC output for
connection to a
private LV network
L1
L2
L3
L1
L2
L3
AC output for
connection to a
MV network
manual DC breaker and an automatic
DC contactor for each power block,
in order to decouple the PV generator
from the inverter.
INGECON® SUN PowerMax Multi-MPPT
Filt
er
Filt
er
Size and weight (mm)
4 blocks Indoor2,100 kg.
3 blocks Indoor1,500 kg.
2 blocks Indoor900 kg.
2,0
40
1,910
925
2,0
40
2,510
925
2,0
40
3,110
925
44
PowerMax Multi-MPPT 220 Vac
275TL M220 410TL M220 550TL M220
Input (DC)
Recommended PV array power range(1) 283 - 325 kWp 424 - 488 kWp 566 - 650 kWp
Voltage Range MPP 405 - 820 V 405 - 820 V 405 - 820 V
Maximum voltage DC(2) 1,000 V 1,000 V 1,000 V
Maximum current DC 900 A 1,350 A 1,800 A
Nº DC inputs with fuse holders 6 (extendable up to 8) 9 (extendable up to 12) 12 (extendable up to 16)
DC fuse dimensions(3) 125 A / 1,000 V to 250 A / 1,000 V fuses, maximum current from 100 to 200 A for positive and negative poles (only DCAC models)
Type of connection Connection to fuse-holder copper bars. Cable entry from the ground through D40 cable glands (max. cable diameter: 40 mm)
Power blocks 2 3 4
MPPT(4) 2 3 4
Input protectionsOvervoltage protections DC surge arresters, type 2 (for each power stage)
DC breaker Manual DC breaker with door control (for each power block)
DC contactor DC contactor to automatically disconnect the inverter from the PV fi eld
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(5) 275 kW 412 kW 550 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 220 V IT System 220 V IT System 220 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(6) 1 1 1
Phi Cosine adjustable Yes. Smax=275 kVA Yes. Smax=412 kVA Yes. Smax=550 kVA
THD (Total Harmonic Distortion)(7) <3% <3% <3%
Output protectionsOvervoltage protections AC surge arresters, type 2
AC breaker Optional AC thermal magnetic breaker with door control, motorized or remote trip (only DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.1% 98.1% 98.1%
Euroeffi ciency 97.7% 97.7% 97.7%
CEC 97.3% 97.3% 97.3%
Stand-by consumptiony(8) 60 W 90 W 120 W
Consumption at night 60 W 90 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(9) 3,000 m 3,000 m 3,000 m
Cooling system Air forced with temperature control (230 V phase + neutral power supply)
Air fl ow 2,670 m3/h (fans: 1,230 W) 4,640 m3/h (fans: 2,050 W) 5,340 m3/h (fans: 2,460 W)
Acoustic emission < 55 dB (A) at 4 m. and < 67 dB (A) at 1 m. with fans working at maximum power
Certifi cation CE
EMC and security standards EN 50178, EN 62109-1, EN 62109-2, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 0-16, CEI 11-20, CEI 11-20 V1, CEI 0-21, Allegato A70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA,IEEE 1547, Arrêté 23-04-08, G59/2, South African Grid Code Draft Rev.0
Effi ciency INGECON® SUN 550TL M220 Vdc = 500 V
Power (kW)
0 150 350250 450 550
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
50
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Consider the voltage increase of the ‘VOC’ at low temperatures (3) For other confi gurations, consult with Ingeteam (4) The MPPT connected to the
same transformer through TL inverters must have the same voltage confi guration (5) AC Power for 45ºC ambient temperature. For each ºC of increase, the output
power will be reduced at the rate of 1.8% (6) For Pout>25% of the rated power (7)
For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (8) Consumption from PV fi eld (9) Over 1,000 m temperature for rated power (45 ºC) is
reduced at the rate of 4.5 ºC for each 1,000 m.
45
On-g
rid
PV in
vert
ers
PowerMax Multi-MPPT 275 Vac
350TL M275 520TL M275 695TL M275
Input (DC)
Recommended PV array power range(1) 354 - 410 kWp 531 - 650 kWp 709 - 819 kWp
Voltage Range MPP 405 - 820 V 405 - 820 V 405 - 820 V
Maximum voltage DC(2) 1,000 V 1,000 V 1,000 V
Maximum current DC 900 A 1,350 A 1,800 A
Nº DC inputs with fuse holders 6 (extendable up to 8) 9 (extendable up to 12) 12 (extendable up to 16)
DC fuse dimensions(3) 125 A / 1,000 V to 250 A / 1,000 V fuses, maximum current from 100 to 200 A for positive and negative poles (only DCAC models)
Type of connection Connection to fuse-holder copper bars. Cable entry from the ground through D40 cable glands (max. cable diameter: 40 mm)
Power blocks 2 3 4
MPPT(4) 2 3 4
Input protectionsOvervoltage protections DC surge arresters, type 2 (for each power stage)
DC breaker Manual DC breaker with door control (for each power block)
DC contactor DC contactor to automatically disconnect the inverter from the PV fi eld
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(5) 346 kW 519 kW 693 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 275 V IT System 275 V IT System 275 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(6) 1 1 1
Phi Cosine adjustable Yes. Smax=346 kVA Yes. Smax=519 kVA Yes. Smax=693 kVA
THD (Total Harmonic Distortion)(7) <3% <3% <3%
Output protectionsOvervoltage protections AC surge arresters, type 2
AC breaker Optional AC thermal magnetic breaker with door control, motorized or remote trip (only DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.5% 98.5% 98.5%
Euroeffi ciency 98.2% 98.2% 98.2%
CEC 97.7% 97.7% 97.7%
Stand-by consumptiony(8) 60 W 90 W 120 W
Consumption at night 60 W 90 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(9) 3,000 m 3,000 m 3,000 m
Cooling system Air forced with temperature control (230 V phase + neutral power supply)
Air fl ow 2,670 m3/h (fans: 1,230 W) 4,640 m3/h (fans: 2,050 W) 5,340 m3/h (fans: 2,460 W)
Acoustic emission < 55 dB (A) at 4 m. and < 67 dB (A) at 1 m. with fans working at maximum power
Certifi cation CE
EMC and security standards EN 50178, EN 62109-1, EN 62109-2, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 0-16, CEI 11-20, CEI 11-20 V1, CEI 0-21, Allegato A70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA,IEEE 1547, Arrêté 23-04-08, G59/2, South African Grid Code Draft Rev.0
Effi ciency INGECON® SUN 695TL M275 Vdc = 550 V
Power (kW)
0 300 500400 600 700
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
200100
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Consider the voltage increase of the ‘VOC’ at low temperatures (3) For other confi gurations, consult with Ingeteam (4) The MPPT connected to the
same transformer through TL inverters must have the same voltage confi guration (5) AC Power for 45ºC ambient temperature. For each ºC of increase, the output
power will be reduced at the rate of 1.8% (6) For Pout>25% of the rated power (7)
For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (8) Consumption from PV fi eld (9) Over 1,000 m temperature for rated power (45 ºC) is
reduced at the rate of 4.5 ºC for each 1,000 m.
46
PowerMax Multi-MPPT 300 Vac
380TL M300 570TL M300 760TL M300
Input (DC)
Recommended PV array power range(1) 386 - 447 kWp 580 - 671 kWp 773 - 894 kWp
Voltage Range MPP 437 - 820 V 437 - 820 V 437 - 820 V
Maximum voltage DC(2) 1,000 V 1,000 V 1,000 V
Maximum current DC 900 A 1,350 A 1,800 A
Nº DC inputs with fuse holders 6 (extendable up to 8) 9 (extendable up to 12) 12 (extendable up to 16)
DC fuse dimensions(3) 125 A / 1,000 V to 250 A / 1,000 V fuses, maximum current from 100 to 200 A for positive and negative poles (only DCAC models)
Type of connection Connection to fuse-holder copper bars. Cable entry from the ground through D40 cable glands (max. cable diameter: 40 mm)
Power blocks 2 3 4
MPPT(4) 2 3 4
Input protectionsOvervoltage protections DC surge arresters, type 2 (for each power stage)
DC breaker Manual DC breaker with door control (for each power block)
DC contactor DC contactor to automatically disconnect the inverter from the PV fi eld
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(5) 378 kW 568 kW 757 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 300 V IT System 300 V IT System 300 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(6) 1 1 1
Phi Cosine adjustable Yes. Smax=378 kVA Yes. Smax=568 kVA Yes. Smax=757 kVA
THD (Total Harmonic Distortion)(7) <3% <3% <3%
Output protectionsOvervoltage protections AC surge arresters, type 2
AC breaker Optional AC thermal magnetic breaker with door control, motorized or remote trip (only DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.6% 98.6% 98.6%
Euroeffi ciency 98.3% 98.3% 98.3%
CEC 97.9% 97.9% 97.9%
Stand-by consumptiony(8) 60 W 90 W 120 W
Consumption at night 60 W 90 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(9) 3,000 m 3,000 m 3,000 m
Cooling system Air forced with temperature control (230 V phase + neutral power supply)
Air fl ow 2,670 m3/h (fans: 1,230 W) 4,640 m3/h (fans: 2,050 W) 5,340 m3/h (fans: 2,460 W)
Acoustic emission < 55 dB (A) at 4 m. and < 67 dB (A) at 1 m. with fans working at maximum power
Certifi cation CE
EMC and security standards EN 50178, EN 62109-1, EN 62109-2, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 0-16, CEI 11-20, CEI 11-20 V1, CEI 0-21, Allegato A70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA,IEEE 1547, Arrêté 23-04-08, G59/2, South African Grid Code Draft Rev.0
Effi ciency INGECON® SUN 760TL M300 Vdc = 550 V
Power (kW)
0 400 600500 700 800
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
100 200 300
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Consider the voltage increase of the ‘VOC’ at low temperatures (3) For other confi gurations, consult with Ingeteam (4) The MPPT connected to the
same transformer through TL inverters must have the same voltage confi guration (5) AC Power for 45ºC ambient temperature. For each ºC of increase, the output
power will be reduced at the rate of 1.8% (6) For Pout>25% of the rated power (7)
For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (8) Consumption from PV fi eld (9) Over 1,000 m temperature for rated power (45 ºC) is
reduced at the rate of 4.5 ºC for each 1,000 m.
47
On-g
rid
PV in
vert
ers
PowerMax Multi-MPPT 320 Vac
400TL M320 605TL M320 800TL M320
Input (DC)
Recommended PV array power range(1) 409 - 475 kWp 617 - 715 kWp 819 - 949 kWp
Voltage Range MPP 468 - 820 V 468 - 820 V 468 - 820 V
Maximum voltage DC(2) 1,000 V 1,000 V 1,000 V
Maximum current DC 900 A 1,350 A 1,800 A
Nº DC inputs with fuse holders 6 (extendable up to 8) 9 (extendable up to 12) 12 (extendable up to 16)
DC fuse dimensions(3) 125 A / 1,000 V to 250 A / 1,000 V fuses, maximum current from 100 to 200 A for positive and negative poles (only DCAC models)
Type of connection Connection to fuse-holder copper bars. Cable entry from the ground through D40 cable glands (max. cable diameter: 40 mm)
Power blocks 2 3 4
MPPT(4) 2 3 4
Input protectionsOvervoltage protections DC surge arresters, type 2 (for each power stage)
DC breaker Manual DC breaker with door control (for each power block)
DC contactor DC contactor to automatically disconnect the inverter from the PV fi eld
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(5) 401 kW 605 kW 803 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 320 V IT System 320 V IT System 320 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(6) 1 1 1
Phi Cosine adjustable Yes. Smax=401 kVA Yes. Smax=605 kVA Yes. Smax=1,472 kVA
THD (Total Harmonic Distortion)(7) <3% <3% <3%
Output protectionsOvervoltage protections AC surge arresters, type 2
AC breaker Optional AC thermal magnetic breaker with door control, motorized or remote trip (only DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.7% 98.7% 98.7%
Euroeffi ciency 98.4% 98.4% 98.4%
CEC 97.9% 97.9% 97.9%
Stand-by consumptiony(8) 60 W 90 W 120 W
Consumption at night 60 W 90 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(9) 3,000 m 3,000 m 3,000 m
Cooling system Air forced with temperature control (230 V phase + neutral power supply)
Air fl ow 2,670 m3/h (fans: 1,230 W) 4,640 m3/h (fans: 2,050 W) 5,340 m3/h (fans: 2,460 W)
Acoustic emission < 55 dB (A) at 4 m. and < 67 dB (A) at 1 m. with fans working at maximum power
Certifi cation CE
EMC and security standards EN 50178, EN 62109-1, EN 62109-2, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 0-16, CEI 11-20, CEI 11-20 V1, CEI 0-21, Allegato A70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA,IEEE 1547, Arrêté 23-04-08, G59/2, South African Grid Code Draft Rev.0
Effi ciency INGECON® SUN 800TL M320 Vdc = 550 V
0 400 600500 700 800
82
94
88
100
84
96
90
86
98
92
100 200 300
Power (kW)
Effi
cie
ncy
(%)
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Consider the voltage increase of the ‘VOC’ at low temperatures (3) For other confi gurations, consult with Ingeteam (4) The MPPT connected to the
same transformer through TL inverters must have the same voltage confi guration (5) AC Power for 45ºC ambient temperature. For each ºC of increase, the output
power will be reduced at the rate of 1.8% (6) For Pout>25% of the rated power (7)
For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (8) Consumption from PV fi eld (9) Over 1,000 m temperature for rated power (45 ºC) is
reduced at the rate of 4.5 ºC for each 1,000 m.
48
PowerMax Multi-MPPT 345 Vac
440TL M345 660TL M345 880TL M345
Input (DC)
Recommended PV array power range(1) 448 - 520 kWp 672 - 780 kWp 896 - 1.040 kWp
Voltage Range MPP 502 - 820 V 502 - 820 V 502 - 820 V
Maximum voltage DC(2) 1,000 V 1,000 V 1,000 V
Maximum current DC 900 A 1,350 A 1,800 A
Nº DC inputs with fuse holders 6 (extendable up to 8) 9 (extendable up to 12) 12 (extendable up to 16)
DC fuse dimensions(3) 125 A / 1,000 V to 250 A / 1,000 V fuses, maximum current from 100 to 200 A for positive and negative poles (only DCAC models)
Type of connection Connection to fuse-holder copper bars. Cable entry from the ground through D40 cable glands (max. cable diameter: 40 mm)
Power blocks 2 3 4
MPPT(4) 2 3 4
Input protectionsOvervoltage protections DC surge arresters, type 2 (for each power stage)
DC breaker Manual DC breaker with door control (for each power block)
DC contactor DC contactor to automatically disconnect the inverter from the PV fi eld
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(5) 440 kW 660 kW 880 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 345 V IT System 345 V IT System 345 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(6) 1 1 1
Phi Cosine adjustable Yes. Smax=440 kVA Yes. Smax=660 kVA Yes. Smax=880 kVA
THD (Total Harmonic Distortion)(7) <3% <3% <3%
Output protectionsOvervoltage protections AC surge arresters, type 2
AC breaker Optional AC thermal magnetic breaker with door control, motorized or remote trip (only DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.8% 98.8% 98.8%
Euroeffi ciency 98.5% 98.5% 98.5%
CEC 98% 98% 98%
Stand-by consumptiony(8) 60 W 90 W 120 W
Consumption at night 60 W 90 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(9) 3,000 m 3,000 m 3,000 m
Cooling system Air forced with temperature control (230 V phase + neutral power supply)
Air fl ow 2,670 m3/h (fans: 1,230 W) 4,640 m3/h (fans: 2,050 W) 5,340 m3/h (fans: 2,460 W)
Acoustic emission < 55 dB (A) at 4 m. and < 67 dB (A) at 1 m. with fans working at maximum power
Certifi cation CE
EMC and security standards EN 50178, EN 62109-1, EN 62109-2, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 0-16, CEI 11-20, CEI 11-20 V1, CEI 0-21, Allegato A70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA,IEEE 1547, Arrêté 23-04-08, G59/2, South African Grid Code Draft Rev.0
Effi ciency INGECON® SUN 880TL M345 Vdc = 600 V
Power (kW)
0 200 600300 800 900
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
100 700500400
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Consider the voltage increase of the ‘VOC’ at low temperatures (3) For other confi gurations, consult with Ingeteam (4) The MPPT connected to the
same transformer through TL inverters must have the same voltage confi guration (5) AC Power for 45ºC ambient temperature. For each ºC of increase, the output
power will be reduced at the rate of 1.8% (6) For Pout>25% of the rated power (7)
For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (8) Consumption from PV fi eld (9) Over 1,000 m temperature for rated power (45 ºC) is
reduced at the rate of 4.5 ºC for each 1,000 m.
49
On-g
rid
PV in
vert
ers
PowerMax Multi-MPPT 360 Vac
460TL M360 690TL M360 920TL M360
Input (DC)
Recommended PV array power range(1) 466 - 546 kWp 700 - 819 kWp 933 - 1,092 kWp
Voltage Range MPP 524 - 820 V 524 - 820 V 524 - 820 V
Maximum voltage DC(2) 1,000 V 1,000 V 1,000 V
Maximum current DC 900 A 1,350 A 1,800 A
Nº DC inputs with fuse holders 6 (extendable up to 8) 9 (extendable up to 12) 12 (extendable up to 16)
DC fuse dimensions(3) 125 A / 1,000 V to 250 A / 1,000 V fuses, maximum current from 100 to 200 A for positive and negative poles (only DCAC models)
Type of connection Connection to fuse-holder copper bars. Cable entry from the ground through D40 cable glands (max. cable diameter: 40 mm)
Power blocks 2 3 4
MPPT(4) 2 3 4
Input protectionsOvervoltage protections DC surge arresters, type 2 (for each power stage)
DC breaker Manual DC breaker with door control (for each power block)
DC contactor DC contactor to automatically disconnect the inverter from the PV fi eld
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(5) 458 kW 688 kW 917 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 360 V IT System 360 V IT System 360 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(6) 1 1 1
Phi Cosine adjustable Yes. Smax=458 kVA Yes. Smax=688 kVA Yes. Smax=917 kVA
THD (Total Harmonic Distortion)(7) <3% <3% <3%
Output protectionsOvervoltage protections AC surge arresters, type 2
AC breaker Optional AC thermal magnetic breaker with door control, motorized or remote trip (only DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.8% 98.8% 98.8%
Euroeffi ciency 98.6% 98.6% 98.6%
CEC 98.1% 98.1% 98.1%
Stand-by consumptiony(8) 60 W 90 W 120 W
Consumption at night 60 W 90 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(9) 3,000 m 3,000 m 3,000 m
Cooling system Air forced with temperature control (230 V phase + neutral power supply)
Air fl ow 2,670 m3/h (fans: 1,230 W) 4,640 m3/h (fans: 2,050 W) 5,340 m3/h (fans: 2,460 W)
Acoustic emission < 55 dB (A) at 4 m. and < 67 dB (A) at 1 m. with fans working at maximum power
Certifi cation CE
EMC and security standards EN 50178, EN 62109-1, EN 62109-2, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 0-16, CEI 11-20, CEI 11-20 V1, CEI 0-21, Allegato A70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA,IEEE 1547, Arrêté 23-04-08, G59/2, South African Grid Code Draft Rev.0
Effi ciency INGECON® SUN 920TL M360 Vdc = 625 V
Power (kW)
0 300 700500 900 1000
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
800600400100 200
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Consider the voltage increase of the ‘VOC’ at low temperatures (3) For other confi gurations, consult with Ingeteam (4) The MPPT connected to the
same transformer through TL inverters must have the same voltage confi guration (5) AC Power for 45ºC ambient temperature. For each ºC of increase, the output
power will be reduced at the rate of 1.8% (6) For Pout>25% of the rated power (7)
For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (8) Consumption from PV fi eld (9) Over 1,000 m temperature for rated power (45 ºC) is
reduced at the rate of 4.5 ºC for each 1,000 m.
50
PowerMax Multi-MPPT 400 Vac
500TL M400 750TL M400 1000TL M400
Input (DC)
Recommended PV array power range(1) 518 - 607 kWp 777 - 910 kWp 1,036 - 1,213 kWp
Voltage Range MPP 578 - 820 V 578 - 820 V 578 - 820 V
Maximum voltage DC(2) 1,000 V 1,000 V 1,000 V
Maximum current DC 900 A 1,350 A 1,800 A
Nº DC inputs with fuse holders 6 (extendable up to 8) 9 (extendable up to 12) 12 (extendable up to 16)
DC fuse dimensions(3) 125 A / 1,000 V to 250 A / 1,000 V fuses, maximum current from 100 to 200 A for positive and negative poles (only DCAC models)
Type of connection Connection to fuse-holder copper bars. Cable entry from the ground through D40 cable glands (max. cable diameter: 40 mm)
Power blocks 2 3 4
MPPT(4) 2 3 4
Input protectionsOvervoltage protections DC surge arresters, type 2 (for each power stage)
DC breaker Manual DC breaker with door control (for each power block)
DC contactor DC contactor to automatically disconnect the inverter from the PV fi eld
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(5) 510 kW 764 kW 1,019 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 400 V IT System 400 V IT System 400 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(6) 1 1 1
Phi Cosine adjustable Yes. Smax=510 kVA Yes. Smax=764 kVA Yes. Smax=1,019 kVA
THD (Total Harmonic Distortion)(7) <3% <3% <3%
Output protectionsOvervoltage protections AC surge arresters, type 2
AC breaker Optional AC thermal magnetic breaker with door control, motorized or remote trip (only DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.8% 98.8% 98.8%
Euroeffi ciency 98.6% 98.6% 98.6%
CEC 98.1% 98.1% 98.1%
Stand-by consumptiony(8) 60 W 90 W 120 W
Consumption at night 60 W 90 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(9) 3,000 m 3,000 m 3,000 m
Cooling system Air forced with temperature control (230 V phase + neutral power supply)
Air fl ow 2,670 m3/h (fans: 1,230 W) 4,640 m3/h (fans: 2,050 W) 5,340 m3/h (fans: 2,460 W)
Acoustic emission < 55 dB (A) at 4 m. and < 67 dB (A) at 1 m. with fans working at maximum power
Certifi cation CE
EMC and security standards EN 50178, EN 62109-1, EN 62109-2, EN 61000-6-2, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 0-16, CEI 11-20, CEI 11-20 V1, CEI 0-21, Allegato A70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA,IEEE 1547, Arrêté 23-04-08, G59/2, South African Grid Code Draft Rev.0
Effi ciency INGECON® SUN 1000TL M400 Vdc = 650 V
Power (kW)
0 300 700500 900 1000
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
800600400100 200
Notes: (1) Depending on the type of installation and geographical location. Data for
STC conditions (2) Consider the voltage increase of the ‘VOC’ at low temperatures (3) For other confi gurations, consult with Ingeteam (4) The MPPT connected to the
same transformer through TL inverters must have the same voltage confi guration (5) AC Power for 45ºC ambient temperature. For each ºC of increase, the output
power will be reduced at the rate of 1.8% (6) For Pout>25% of the rated power (7)
For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (8) Consumption from PV fi eld (9) Over 1,000 m temperature for rated power (45 ºC) is
reduced at the rate of 4.5 ºC for each 1,000 m.
51
On-g
rid
PV in
vert
ers
Integrated Optional Not available
M DCAC Indoor M DC Indoor M DCAC Outdoor X DCAC Indoor X DC Indoor X DCAC Outdoor
ProtectionsReverse Polarity DC
Output overvoltage DC
(type 2 surge suppressors)
Output overvoltage AC
(type 2 surge suppressors)
Output short circuits and overloads
Insulation failure DC
Insulation failure AC
Anti-islanding with automatic shutdown
DC fuse holder
DC fuses
DC automatic contactor
DC load breaker
Motorized DC load breaker
AC thermal magnetic breaker
with remote tripping(1)
Integrated accessoriesPotential free contact to indicate an
insulation fault
Heating resistor
Grounding kit
Sync kit
Night power supply
Input current monitoring per fuse
Detection of blown DC fuse
AC Wattmeter
Firmware updatable
via communication
CommunicationCommunication RS-485
Communication ethernet
Communication GPRS
Plant power control(2)
Wireless ISM868
Bluetooth
SoftwareINGECON® SUN Manager for plant
monitoring
INGECON® SUN Monitor for
data viewing
Notes: (1) It can also be resettable (2) Equipment prepared, an external control is required.
INTEGRATED AND OPTIONAL ACCESSORIES
PowerMax Multi-MPPT PowerMax Master-Slave
5252
BOX Outdoor
M220 / M275 / M300 / M320 / M345 / M360 / M400 OutdoorX220 / X275 / X300 / X320 / X345 / X360
Designed for outdoor installationSuitable for direct outdoor installation
thanks to its compact, weatherproof
enclosure. Used together with the
INGECON® SUN MV Box it allows
for direct connection to the MV
electricity grid.
Maximum effi ciency with independent conversion modulesThanks to its modular composition and
to the fact that no galvanic isolation
transformer is required, it is possible
to considerably increase the PV plant
effi ciency. Each independent module is
equipped with an advanced maximum
power point tracking system (MPPT)*.
Ease of maintenanceThe distribution of the work load
between the independent power
conversion blocks leads to maximum
effi ciency and a useful life of more than
20 years.
Compliance with the most demanding standards and regulationsThe INGECON® SUN Box inverters are
equipped with all the functions, and
DC and AC electrical protections,
required by the most demanding
standards and regulations.
Standard 5 year warranty, extendible up to 25 years
Inverters for outdoor installation, ideal for large multi-megawatt plants
EFFICIENCY
INGECON® SUN Box
Vdc = 625 V
80
92
86
98
82
94
88
100
84
96
90
0 63 188125 313250 375 438 500 563 625
Power (kW)
Effi
cie
ncy
(%
)
* The confi guration of the PV generator strings going into the MPPT modules connected to the same transformer, must be as similar as possible.
5353
On-g
rid
PV in
vert
ers
LVRT Kit for low voltage ride through.
Kit for a parallel connection to the HV grid.
Night-time power supply kit.
Inter-inverter communications via Ethernet or Bluetooth.
Ethernet or GSM/GPRS modem board for remote
communication.
Analogue input board to receive the signals coming from the
climatic sensors.
INGECON® SUN ComBox communications centre.
PV array string current monitoring through the INGECON®
SUN StringControl.
Size and weight (mm)
INGECON® SUN Box M220 / M275 / M300 / M320 / M345 / M360 / M400 Outdoor
INGECON® SUN Box X220 / X275 / X300 / X320 / X345 / X360
FEATURES
Suitable for outdoor installation and IP54 protection class for use
in any climatic conditions.
Maximum effi ciency 98.8%
Useful life of more than 20 years, thanks to the polypropylene
capacitors and Ingeteam’s “Long Life System.” for reducing the
interfering inductance of the IGBTs.
“Fire Safety System” based on DC contactors to disconnect the
PV generator in the event of fi re.
Reactive power control up to +/- 35% of the rated power in supply
condition with an active power of ≥ 5%.
Lower inverter production losses in the event of a power block failure,
thanks to its modular architecture.
Low maintenance costs: the same spare parts kit for all power modules.
Ease of maintenance thanks to the modular architecture of the power
conversion blocks and to the built-in diagnostic system.
Integrated LCD graphic display.
Inter-inverter communication through integrated RS-485.
Integrated datalogger for up to 3 months data storage.
INGECON® SUN Manager software for parameter display and plant
data recording.
INGECON® SUN Monitor portal to view the plant data.
Compliant with the principal medium and high voltage directives.
Manufacturer’s 5 year warranty, extendible up to 25 years on request.
Box Outdoor
Connection
to the MV grid
PV input
PV input
Box Outdoor2 conversion modules
2,080 kg.
Box Outdoor3 conversion modules
2,780 kg.
Box Outdoor4 conversion modules
3,480 kg.
+16
...
+3
+2
+1
-1
-2
-3
...
-16
F
F
F
F
F
F
F
F
F
Inverter 1
Inverter 2
Inverter 3
Inverter 4
FilterEMC
FilterEMC
FilterEMC
FilterEMC
F
F
F
F
TAUTF
TVUTF
1600 A
1,067
2,6
81
2,9871,0
67
2,6
81
3,587
1,067
2,6
81
4,029
OPTIONAL ACCESSORIES
5454
From 275 kW to 2000 kW - 15 / 20 / 36 kV
Simplifi es the PV installation procedureIt links the outdoor inverters and the
MV grid. Housing everything required
to complete the connection of the
INGECON® SUN outdoor inverters to the
utility company’s MV grid, including the
LV/MV transformer, the MV cells and the
LV auxiliary services switchgear. A range
of accessories are available to confi gure
the INGECON® SUN MV Box to suit the
requirements of each specifi c customer.
Ease of maintenanceA low-maintenance structure with a
useful life of more than 20 years. In the
event of a failure, the doors ensure ease
of access to the internal components,
shortening repair times and lowering
maintenance costs.
Designed for outdoor installationSuitable for direct outdoor installation
thanks to its compact, weatherproof
enclosure. Simple mounting on a
cement base, telescopic guides for the
access conduits to the cable protection.
Standard 2 year warranty, extendible up to 25 years
Medium voltage transformer box designed for outdoor installation, ideal for large multi-megawatt plants
AC
AC
AC
Public grid
5555
On-g
rid
PV in
vert
ers
15 kVA / 400 Vac auxiliary transformer.
UPS for auxiliary services.
Fiscal energy meter with a GSM system for remote readings.
Metering of the AC energy produced through approved TV
voltage sensors and TA current sensors.
Version for a 36 kV transformer.
Forced ventilation system under the transformer.
INGECON® SUN ComBox, centralised communication system
with RS-485/USB/Ethernet interface.
INGECON® SUN Manager software for parameter display and
plant data recording.
INGECON® SUN Monitor portal to view the plant data.
Compliant with the principal medium and high voltage
directives and regulations.
Medium voltage safety provisions: class 2 gloves and 30 kV
insulating platform.
Portable 5 kg CO2 fi re extinguisher.
Manufacturer’s 2 year warranty, extendible up to 25 years
on request.
Suitable for outdoor installation and IP54 protection class for use
in any climatic conditions.
LV/MV transformer up to 2,300 kVA and 36 kV.
Compatible with resin and oil transformers.
Forced air cooling system through the transformer compartment,
with temperature probes and central thermometric control.
Ease of access for normal and extraordinary maintenance.
Hot galvanised structure for a useful life of more than 20 years.
Ease of access to the MV transformer in order to connect the
cables running from the PV array.
Built-in LV-Aux low voltage switchgear with everything required to
complete the PV installation.
Extensive selection of medium voltage cells, for either a radial or
ring connection.
It is possible to mount cells with a General Protection and
Interface Protection.
Lower installation and connections costs.
Communication with the INGECON® SUN Box inverters through
integrated RS-485.
Opto-couplers for an RS-485 connection by means of string boxes
through the LV-Aux switchgear.
Complete internal lighting system with emergency lights from
60 minutes onwards.
INGECON® SUN MV Box
Size (mm)
MV Box
LV connection Inverter 1
MCM2
LV connection Inverter 2
Measurement Inverter 1
Measurement Inverter 2
LV/MV transformer
up to 2,000 kVA
LV - AUX PANEL
MVC SF-LS-LS
MV GRID
MCM2
CF CF
Sealable terminal blocks
M2 meters energy prodced
ServiciosAUX
Transformer 15 kVA
Insulation meters
I.M
.
I.M
.
M
Y01
YC
FU
2,2003,200
3,200 4,400
2,200 2,200
FEATURES
OPTIONAL ACCESSORIES
5656
SHE 15
Maximize your investment with minimal effortINGECON® SUN PowerStation SHE 15
is a compact, customisable and fl exible
solution that can be confi gured to suit
each customer’s requirements. Thanks
to its panel-based structure, the internal
layout can be customised to incorporate
various INGECON® SUN inverters.Ideal
for low environmental impact applications.
Extremely robust and long-lasting
The shelter can be easily transported by
road, thanks to its small dimensions and
low overall weight. The hot galvanised
steel structure is designed to guarantee
maximum mechanical strenght and
durability. The walls and roof contain
a 50 mm rigid fi re-proof polyurethane
foam fi lling, to guarantee perfect water
resistance and correct thermal insulation.
Equipped with everything necessaryInverters, Low Voltage parallel cabinet,
auxiliary services panel, medium voltage
cubicle and LV/MV transformer.
Maximum stability All the devices are anchored to the
base, to guarantee the maximum
stability of the structure. The varnish
used guarantees maximum protection
against adverse weather conditions.
80
92
86
98
82
94
88
100
84
96
90
0 63 188125 313250 375 438 500 563 625
Power (kW)
Effi
cie
ncy
(%
)
EFFICIENCY
INGECON® SUN PowerStation
Vdc = 550-625 V
MAIN FEATURES
Power from 300
to 1150 kWp.
Compact design.
Plug & Play solution.
Customizable.
Extremely versatile.
Industry-leading performances.
Maximum return of investment.
Guarantee of quality.
BENEFITS
ELECTRICAL PROTECTIONS
DC and AC Class II surge arresters.
DC breaker with door control.
DC fuses.
AC thermal magnetic circuit breaker
with door control.
DC insulation monitor.
Anti-islanding monitoring system with
automatic disconnection.
Protection against short-circuits and
output overloads.
Emergency button for the inverters.
Disconnection system in case of LV/MV
transformer overheat.
Emergency disconnecting pushbutton
accessible from the outside.
275... 1000 kWThe most compact solution on the market designed by Ingeteam. All the devices required for a multi-megawatt system incorporated into a single shelter.
5757
On-g
rid
PV in
vert
ers
INGECON® SUN PowerStation SHE 15
OPTIONAL EQUIPMENT
In addition to the standard equipment, the
INGECON® SUN Power Station SHE15 can
be supplied with the following options:
Fiscal energy meter with GSM
communication module for remote
monitoring.
LV/LV transformer for auxiliary services
switchgear power supply.
UPS for auxiliary services.
INGECON® SUN ComBox centralized
communication system with
RS485/USB/ETHERNET interfaces.
GSM/GPRS modem
SCADA system for photovoltaic
plant monitoring.
On-site plant start-up.
Complete accessibility Thanks to its innovative design, all
devices are readily accessible, thereby
making it easier to inspect, maintain and
repair the INGECON® SUN PowerStation
SHE 15. The transformer compartment
door is equipped with an Arel safety lock
with a blocking code.
Innovative ventilation system
The internal temperature is controlled
by a centrifugal fan system. A number
of internal and external probes
guarantee a constant ambient
temperature. The incoming air is fi ltered
through special grids mounted on the
bottom of the walls.
Dimensions (mm)
SHE 15with all doors closed
SHE 15with all doors open
2.437
2.8
96
4.4005.622
2.8
96
5.761
5858
SHE 20
EFFICIENCY
80
92
86
98
82
94
88
100
84
96
90
0 63 188125 313250 375 438 500 563 625
Power (kW)
Effi
cie
ncy
(%
)
INGECON® SUN PowerStation
Vdc = 550-625 V
The very latest technological
development by Ingeteam. All the
devices required for a multi-megawatt
system incorporated into a single shelter.
Maximize your investment with minimal effortINGECON® SUN PowerStation SHE 20
is a compact, customisable and fl exible
solution that can be confi gured to suit
each customer’s requirements. Thanks
to its panel-based structure, the internal
layout can be customised to incorporate
various INGECON® SUN inverters.Ideal
for low environmental impact applications.
Extremely robust and long-lasting
The shelter can be easily transported by
road, thanks to its small dimensions and
low overall weight. The hot galvanised
steel structure is designed to guarantee
maximum mechanical strenght and
durability. The walls and roof contain
a 50 mm rigid fi re-proof polyurethane
foam fi lling, to guarantee perfect water
resistance and correct thermal insulation.
Equipped with everything necessaryInverters, Low Voltage parallel cabinet,
auxiliary services panel, medium voltage
cubicle and LV/MV transformer.
Maximum stability All the devices are anchored to the
base, to guarantee the maximum
stability of the structure. The varnish
used guarantees maximum protection
against adverse weather conditions.
MAIN FEATURES
Power from 300
to 2,300 kWp.
Compact design.
Plug & Play solution.
Customizable.
Extremely versatile.
Industry-leading performances.
Maximum return of investment.
Guarantee of quality.
BENEFITS
ELECTRICAL PROTECTIONS
DC and AC Class II surge arresters.
DC breaker with door control.
DC fuses.
AC thermal magnetic circuit breaker
with door control.
DC insulation monitor.
Anti-islanding monitoring system with
automatic disconnection.
Protection against short-circuits and
output overloads.
Emergency button for the inverters.
Disconnection system in case of LV/MV
transformer overheat.
Emergency disconnecting pushbutton
accessible from the outside.
275... 2000 kW
Complete turnkey solution, personalized and fully equipped. Up to 2.300 kWp
5959
On-g
rid
PV in
vert
ers
INGECON® SUN PowerStation SHE 20
OPTIONAL EQUIPMENT
In addition to the standard equipment, the
INGECON® SUN Power Station SHE20 can
be supplied with the following options:
Fiscal energy meter with GSM
communication module for remote
monitoring.
LV/LV transformer for auxiliary services
switchgear power supply.
UPS for auxiliary services.
INGECON® SUN ComBox centralized
communication system with
RS485/USB/ETHERNET interfaces.
GSM/GPRS modem
SCADA system for photovoltaic
plant monitoring.
On-site plant start-up.
Complete accessibility Thanks to its innovative design, all
devices are readily accessible, thereby
making it easier to inspect, maintain and
repair the INGECON® SUN PowerStation
SHE 20. The transformer compartment
door is equipped with an Arel safety lock
with a blocking code.
Innovative ventilation system
The internal temperature is controlled
by a centrifugal fan system. A number
of internal and external probes
guarantee a constant ambient
temperature. The incoming air is fi ltered
through special grids mounted on the
bottom of the walls.
6.831
2.8
96
9.364
Dimensions (mm)
SHE 20with all doors closed
SHE 20with all doors open
2.424
2.8
96
6.074
6060
CON 20
EFFICIENCY
INGECON® SUN PowerStation
Vdc = 550-625 V
80
92
86
98
82
94
88
100
84
96
90
0 63 188125 313250 375 438 500 563 625
Power (kW)
Effi
cie
ncy
(%)
The INGECON® SUN PowerStation CON
20 offers a standard solution, designed
to be marketed at a world level. Thanks
to its optional CSC RINA certifi cation, it
can be shipped by sea to anywhere in
the world.
Robust and long-lasting designIts welded galvanised steel monoblock
structure guarantees maximum
mechanical strength and durability. The
walls and roof contain a 50 mm rigid
fi re-proof polyurethane foam feeling, to
guarantee perfect water resistance and
correct thermal insulation.
Equipped with everything necessary Inverters, Low Voltage parallel cabinet,
auxiliary services panel, medium voltage
cubicle and LV/MV transformer.
Maximum stability
All the devices are anchored to the base,
to guarantee the maximum stability
of the structure. The varnish used
guarantees maximum protection against
adverse weather conditions.
MAIN FEATURES
Power from 300
to 2,300 kWp.
Extremely compact
design.
Plug & Play solution.
Customizable.
Extremely versatile.
High effi ciency.
Maximum return of investment.
Guarantee of quality.
BENEFITS
ELECTRICAL PROTECTIONS
Reverse polarity.
Output short-circuits and overloads.
DC breaker with door control.
DC fuses.
AC thermal-magnetic breaker with door control.
DC and AC voltage surge suppressors.
Anti-islanding monitoring system with
automatic disconnections.
Insulation control.
Emergency button.
Disconnection system should the LV/MV
transformer overheat.
Emergency disconnection button,
accessible from outside.
300... 2000 kW
The integrated “turnkey” solution and customized up to 2,300 kWp, available worldwide
6161
On-g
rid
PV in
vert
ers
INGECON® SUN PowerStation CON 20
OPTIONAL EQUIPMENT
In addition to the standard equipment,
the INGECON® SUN Power Station can be
supplied with the following options:
Energy meter with GSM system for
remote metering.
LV/LV transformer for the power supply to
the BT-AUX auxiliary services panel.
UPS for auxiliary services.
INGECON® SUN ComBox, centralised
communication system with RS-485/
USB/ETHERNET interfaces.
GSM/GPRS Modem.
SCADA monitoring system.
Start-up at the place of installation.
CSC RINA certifi cate.
Complete accessibility Thanks to its innovative design, all
devices are readily accessible, thereby
making it easier to inspect, maintain and
repair the INGECON® SUN PowerStation
CON 20. The transformer compartment
door is equipped with an Arel safety lock
with a blocking code.
Innovative ventilation system
The internal temperature is controlled
by a centrifugal fan system. A number
of internal and external probes
guarantee a constant ambient
temperature. The incoming air is fi ltered
through special grids mounted on the
bottom of the walls.
2.424
2.8
96
6.074
6.831
2.8
96
9.364
Dimensions (mm)
CON 20with all doors closed
CON 20with all doors open
6262
CON 40
EFFICIENCY
80
92
86
98
82
94
88
100
84
96
90
0 63 188125 313250 375 438 500 563 625
Power (kW)
Effi
cie
ncy
(%)
INGECON® SUN PowerStation
Vdc = 550-625 V
A technological solution designed to
be marketed and installed all over the
world at sites with particularly adverse
environmental conditions. Thanks to its
CSC RINA certifi cation it can be shipped
by sea to anywhere in the world.
Ideal for extreme environmental conditionsIts welded galvanized steel monoblock
guarantees maximum mechanical
strenght and durability. The container
inverter area can optionally be equipped
with an interior climate control system,
using industrial air conditioners with a
Free Cooling function (IP54 version) or
air recirculation system (IP65 version).
Perfect water resistance and thermal insulation The entire container exterior is
galvanised and varnished with
polyurethane enamel for maximum
protection against adverse weather
conditions. The walls and roof contain
a 50 mm rigid fi re-proof polyurethane
foam feeling, to guarantee perfect water
resistance and correct thermal insulation.
Complete accessibility
Thanks to its innovative design, all devices
are readily accessible, thereby making it
easier to inspect, maintain and repair the
INGECON® SUN PowerStation CON40. The
transformer compartment door is equipped
with an Arel safety lock with a blocking code.
MAIN FEATURES
Power from 300
to 2,300 kWp.
Extremely compact design.
Plug & play solution.
Forced air cooling.
Free Cooling air conditioning.
Air recirculation conditioning.
Available up to 36 kV.
CSC RINA certifi cation.
Extremely versatile.
High effi ciency.
Maximum returns on investment.
Guarantee of quality.
BENEFITS
ELECTRICAL PROTECTIONS
Reverse polarity.
Output short-circuits and overloads.
DC breaker with door control.
DC fuses.
AC thermal-magnetic breaker with door control.
DC and AC voltage surge suppressors.
Anti-islanding monitoring system with
automatic disconnections.
Insulation control.
Emergency button.
Disconnection system should the LV/MV
transformer overheat.
Emergency disconnection button,
accessible from outside.
275... 2000 kW
The integrated “turnkey” solution and customized, up to 2,300 kWp, for harsh environmental conditions
6363
On-g
rid
PV in
vert
ers
INGECON® SUN PowerStation CON 40
OPTIONAL EQUIPMENT
In addition to the standard equipment,
the INGECON® SUN Power Station can be
supplied with the following options:
Energy meter with GSM system for
remote metering.
LV/LV transformer for the power supply to
the BT-AUX auxiliary services panel.
UPS for auxiliary services.
INGECON® SUN ComBox, centralised
communication system with RS-485/
USB/ETHERNET interfaces.
GSM/GPRS Modem.
SCADA monitoring system.
Start-up at the place of installation.
CSC RINA certifi cate.
Innovative ventilation systemThe internal temperature is controlled
by a centrifugal fan system. A number
of internal and external probes
guarantee a constant ambient
temperature. The incoming air is
fi ltered through special grids mounted
on the bottom of the walls. Optionally,
the container can be ordered with
an internal cooling system featuring
a Free Cooling function (only in
IP54 conditioned version), with an
air conditioner sized for each of the
inverters, and with the following
functions:
Pure Free Cooling
Compressor in OFF mode. The
outdoor air temperature is low and the
conditioner operates like a ventilation
system, with an air infl ow and outfl ow.
Assisted Free Cooling
Compressor operates in ON-OFF mode.
The outdoor air temperature is relatively
low to allow operation in Free Cooling
mode. However, it is not low enough to
maintain the desired interior temperature.
Cooling
Compressor in ON mode. The system
operates like a normal air conditioner.
2.8
96
2.8
96
12.192
CON 40
Dimensions (mm)
12.192
CON
2.439
6464
Installation with multiple PowerStations in star connection
Single PowerStation
Different installation confi gurations
Installation with multiple PowerStations in delta connection
This system is very fl exible
and offers different
confi guration possibilities.
A single component can
control all the elements,
reducing production times,
facilitating the maintenance
and making repairing
processes more effi cient.
Confi guration
National grid
administrator
+ MV
National grid
administrator
+ MV
National grid
administrator
+ MV
MT
MT MT
MT
MT
MT
MT
MT
6565
On-g
rid
PV in
vert
ers
Confi guration with PowerMax Master-Slave inverters
Confi guration with PowerMax Multi-MPPT inverters
Electric diagrams
Auxiliary
Services
AC AUXILIARY
15 kVA
1.760 kVA
MV Board
AC Auxiliary electric supply can be done from the 15 kVA transformer or from the grid
1 String Box
2 String Box
n String Box
1 String Box
2 String Box
n String Box
INGECON® SUN PowerMax
from 2 to 4 MPPT
INGECON® SUN PowerMax
from 2 to 4 MPPT
AC Board
Inverter PowerMax X
Inverter PowerMax X
Optional
Interface Protection 27/59/81
AC AUXILIARY
Counter
GSM
Optional
15 kVA transformer
Aux. Services
LV/MV TRANSFORMER
MV Board
AC Auxiliary electric supply can be done from the 15 kVA transformer or from the grid
Board supply Air-ConditionerIllumination
Grid connection 400 V
OFF-GRID AND MICRO-GRID INVERTERS
6868
PROTECTIONS
OPTIONAL ACCESSORIES
ACCESSORIES BY DEFAULT
With transformer
The INGECON® HYBRID AC Link single-
phase inverter complies with the most
demanding international standards.
The core of the off-grid systemThe INGECON® HYBRID AC Link inverter
generates an off-grid AC network and acts
as a grid manager, guaranteeing the correct
balance between generation, consumption
and the storage system. To do so, the
Ingecon® Hybrid AC Link controls the
energy fl ow between the network and the
batteries, based on the situation at any
given time.
An advanced control system, requiring
no communications, manages the power
generated by the INGECON® SUN and
INGECON® µWIND inverters, based on
consumption and the battery charge status.
Furthermore, the INGECON® HYBRID AC
Link permits the connection of a back-up
generator, should this be necessary.
Battery managementThe INGECON® HYBRID AC Link features a
highly advanced battery control technology
that ensures the maximum life of the
storage system. The battery temperature
is controlled at all times ensuring an
enhanced lifespan of the accumulator.
Stand-alone systemsThe system power can be increased by
connecting a number of INGECON® HYBRID
AC Link inverters in parallel.It is also possible
to create three-phase networks from three
INGECON® HYBRID AC Link inverters.
Maximum compatibilityThe generation of renewable energy
is achieved through the connection of
INGECON® SUN and INGECON® HYBRID
AC conventional inverters to the AC network.
The recommended power ratio between
generating inverters and INGECON®
HYBRID AC Link inverters is 2:1.
Standard 3 year warranty, extendable for up to 25 years
Perfect production management, storage and consumption of energy.
2.4 / 3 / 5 / 6
Galvanic isolation between
the DC and AC side.
DC overvoltages.
AC overvoltages.
Insulation faults.
Shortcircuits and overloads at
the output (confi gurable).
Remote GSM/GPRS, o Bluetooth
communication via modem.
RS-485 communication.
Potential free contact for connection
and disconnection the back-up
generator.
Confi gurable potential
free contact.
PT100 (3-wire) battery temperature
measurement.
Size and weight (mm)
Transformer
5 / 665 kg.
2.4 / 343.3 kg.
47
0
180
360
320
140
32
0
e and consumption of energy.
6969
Off-
grid
and
mic
ro-g
rid
inve
rter
s
INGECON® HYBRID AC Link with transformer
2.4 3 5 6
Input (DC) (Battery)
Battery voltage 48 - 250 V 60 - 250 V 96 - 250 V 120 - 250 V
Charge/discharge current 50 A 50 A 50 A 50 A
Battery type Lead, Ni-Cd, Li-ion Lead, Ni-Cd, Li-ion Lead, Ni-Cd, Li-ion Lead, Ni-Cd, Li-ion
Input (AC) (Generator / grid)
Rated voltage 230 V 230 V 230 V 230 V
Voltage range 170 - 265 V 170 - 265 V 170 - 265 V 170 - 265 V
Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Frequency range 40 / 70 Hz 40 / 70 Hz 40 / 70 Hz 40 / 70 Hz
Charge current range 0 - 14 A 0 - 14 A 0 - 26 A 0 - 26 A
Generator or grid maximum power 6,000 W 6,000 W 11,000 W 11,000 W
Output (AC) (Loads)
Rated power AC(1) 2.4 kW 3 kW 5 kW 6 kW
Power AC (25ºC) 30 min, 2 min, 3 s 2,800 / 3,100 / 5,200 W 3,500 / 3,900 / 5,500 W 5,400 / 5,800 / 9,000 W 6,400 / 6,900 / 9,700 W
AC current 11 A 13 A 22 A 26 A
Rated AC voltage(2) 220 / 230 / 240 / 250 V 220 / 230 / 240 / 250 V 220 / 230 / 240 / 250 V 220 / 230 / 240 / 250 V
Rated AC frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Effi ciencyMaximum effi ciency 94% 94% 94.5% 94.5%
General InformationStand-by consumption <10 W <10 W <10 W <10 W
Ambient temperature -20ºC to +70°C -20ºC to +70°C -20ºC to +70°C -20ºC to +70°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95% 0 - 95%
Protection class IP65 IP65 IP65 IP65
Notes: (1) AC Power for 40ºC ambient temperature (2) Voltage confi gurable through the display.
Compliance with standards: EN62109-1, EN62109-2, EN61000-6-2, EN61000-6-3, RD1699/2011, P.O.12.3, VDE-AR-N4105, CEI 11-20, CEI 0-21, Allegato 70 TERNA, CEI 0-16 Ed. III,
VDE0126-1-1, G83/1-1, G83/2.
Wiring diagram
Wind turbine
Consumption
Back-up Generador
(A generator can be connected
instead of the public grid)
AC
DC
PV array
DC
INGECON® SUN 1Play
AC
INGECON® µWIND Interface
DC
INGECON® µWIND
AC
AC
AC
Batteries
DC
INGECON® SUN HYBRID AC Link
AC
Note: scalable power by
parallelization of inverters
INGECON® HYBRID AC Link.
7070
5TL / 6TL23,3 kg.
2,4TL / 3TL18,3 kg.
360
180
47
0
Transformerless
Size and weight (mm)
PROTECTIONS
OPTIONAL ACCESSORIES
ACCESSORIES BY DEFAULT
The INGECON® HYBRID AC Link single-
phase inverters generate an off-grid AC
network with the characteristics of a
conventional grid.
The core of the off-grid systemThe INGECON® HYBRID AC Link inverter
generates an off-grid AC network and acts
as a grid manager, guaranteeing the correct
balance between generation, consumption
and the storage system. To do so, the
INGECON® HYBRID AC Link controls the
energy fl ow between the network and the
batteries, based on the situation at any
given time.
An advanced control system, requiring
no communications, manages the power
generated by the INGECON® SUN and
INGECON® µWIND inverters, based on
consumption and the battery charge status.
Furthermore, the INGECON® HYBRID AC
Link permits the connection of a back-up
generator, should this be necessary.
Battery managementThe INGECON® HYBRID ACLink features a
highly advanced battery control technology
that ensures the maximum life of the
storage system. The battery temperature
is controlled at all times ensuring an
enhanced lifespan of the accumulator.
Maximum compatibilityThe generation of renewable energy
is achieved through the connection of
INGECON® SUN and INGECON® HYBRID
AC conventional inverters to the AC network.
The recommended power ratio between
generating inverters and INGECON®
HYBRID AC Link inverters is 2:1.
Standard 3 year warranty, extendable for up to 25 years
Perfect production management, storage and consumption of energy.
2.4TL / 3TL / 5TL / 6TL
DC overvoltages.
AC overvoltages.
Insulation faults.
Shortcircuits and overloads at
the output (confi gurable).
Remote GSM/GPRS, o Bluetooth
communication via modem.
RS-485 communication.
Potential free contact for connection
and disconnection the back-up
generator.
Confi gurable potential
free contact.
PT100 (3-wire) battery temperature
measurement.
7171
Off-
grid
and
mic
ro-g
rid
inve
rter
s
2.4TL 3TL 5TL 6TL
Input (DC) (Battery)
Battery voltage 48 - 250 V 60 - 250 V 96 - 250 V 120 - 250 V
Charge/discharge current 50 A 50 A 50 A 50 A
Battery type Lead, Ni-Cd, Li-ion Lead, Ni-Cd, Li-ion Lead, Ni-Cd, Li-ion Lead, Ni-Cd, Li-ion
Input (AC) (Generator / grid)
Rated voltage 230 V 230 V 230 V 230 V
Voltage range 170 - 265 V 170 - 265 V 170 - 265 V 170 - 265 V
Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Frequency range 40 / 70 Hz 40 / 70 Hz 40 / 70 Hz 40 / 70 Hz
Charge current range 0 - 14 A 0 - 14 A 0 - 26 A 0 - 26 A
Generator or grid maximum power 6,000 W 6,000 W 11,000 W 11,000 W
Output (AC) (Loads)
Rated power AC(1) 2.4 kW 3 kW 5 kW 6 kW
Power AC (25ºC) 30 min, 2 min, 3 s 2,800 / 3,100 / 5,200 W 3,500 / 3,900 / 5,500 W 5,400 / 5,800 / 9,000 W 6,400 / 6,900 / 9,700 W
AC current 11 A 13 A 22 A 26 A
Rated AC voltage(2) 220 / 230 / 240 / 250 V 220 / 230 / 240 / 250 V 220 / 230 / 240 / 250 V 220 / 230 / 240 / 250 V
Rated AC frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Effi ciencyMaximum effi ciency 94% 94% 94.5% 94.5%
General InformationStand-by consumption <10 W <10 W <10 W <10 W
Ambient temperature -20ºC to +70°C -20ºC to +70°C -20ºC to +70°C -20ºC to +70°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95% 0 - 95%
Protection class IP65 IP65 IP65 IP65
Wiring diagram
Notes: (1) AC Power for 40ºC ambient temperature (2) Voltage confi gurable through the display.
Compliance with standards: EN62109-1, EN62109-2, EN61000-6-2, EN61000-6-3, RD1699/2011, P.O.12.3, VDE-AR-N4105, CEI 11-20, CEI 0-21, Allegato 70 TERNA, CEI 0-16 Ed. III,
VDE0126-1-1, G83/1-1, G83/2.
AC
DC
INGECON® SUN 1Play
AC
INGECON® µWIND Interface
DC
INGECON® µWIND
AC
AC
AC
INGECON® SUN HYBRID AC Link
AC
INGECON® HYBRID AC Link transformerless
Wind turbine
Consumption
Back-up Generador
(A generator can be connected
instead of the public grid)
PV array
DC
Batteries
DC
7272
Single phase inverter for medium sized stand-alone gridsA single phase grid for consumptions
of up to 10 kVA, based on renewable
energy sources and accumulators.
Stainless steel housing. The system
has been designed with an advanced
algorithm MPPT (>99.7% performance) to
optimize the renewable energy production.
Functions as an energy manager To guarantee the balance between
power generation, accumulation and
consumption, connecting the back-up
generator whenever necessary. PV array
ground-fault monitor. Short-circuitable
output suitable for motor start-up.
Auxiliary input automatic management.
Designed for a bidirectional connection to the utility gridIf confi gured for grid operation, it can
inject the PV power not consumed at
the installation.
Easy to install The inverter parameter confi guration,
control and monitoring can either be
performed on-site using the front display
and keypad or remotely through the
INGECON® SUN Manager.
Software includedIt includes, without any extra cost,
the software INGECON® SUN Manager for
displaying and recording the data directly
from the inverter.
Standard 3 year warranty, extendable for up to 25 years
Medium sized stand-alone grids
10
Single phase
Size and weight (mm)
10200 kg.
1,1
40
520550
670
PROTECTIONS
Integrated electrical protections
against transient voltage surges
through varistors.
Detection of PV array insulation
failure.
Output short-circuit and overload
protections.
System monitoring and control
via RS-485, fi bre optics,
wireless or Ethernet.
Modem for GSM/GPRS remote
communication.
OPTIONAL ACCESSORIES
ACCESSORIES BY DEFAULT
Kit for back-up generator input.
Kit for public grid input.
Galvanic isolation transformer.
7373
Off-
grid
and
mic
ro-g
rid
inve
rter
s
INGECON® HYBRID MS single phase
10
PV Input
Voltage range 180 - 450 Vdc
Power 10 kW
Battery InputRated voltage 120 Vdc
Maximum bank current 100 A
Auxiliary Input (back-up generator / grid)
Maximum power for battery charging 10 kW
Maximum power for consumption 10 kVA
OutputRated power 10 kVA
Output voltage 220 - 250 Vac single - phase
Output frequency 50 / 60 Hz
THD <4%
Phi Cosine -1 to 1
Effi ciencyEffi ciency (transformer included) >94%
General InformationAmbient temperature -10ºC to +45ºC
Protection class IP20
Compliance with standards: CE.
Wiring diagram
ACDC
PV array
Batteries Public grid
Consumption
Back-up
Generator
AC
ACDC
7474
Flexibility
Three phase inverters based on an
innovative modular system for shorter
manufacturing and assembly times and
enhanced logistics.
Easily adaptable to suit plant-specifi c
requirements, whilst offering future
expandability. Each system can comprise
a maximum of 4 energy manager modules,
4 inverter modules, 4 PV modules and 4
wind turbine modules.
Photovoltaic modules and modules for wind turbineEach module for each wind turbine and
photovoltaic module has 3 inputs which
can be connected in parallel.
The photovoltaic modules are equipped
with an advanced tracking system
maximum power point tracking (MPPT)
for maximum output power in any working
condition. The modules for wind turbine
are designed for easy connection to
alternating current of wind turbines, both
synchronous and asynchronous.
Grid ManagementThe battery charger module operates as
an energy manager ensures the balance
between the generation, storage and
consumption, connecting the auxiliary
generator in case of need.
Easy installation and maintenanceIntegrated data logger for storing data up to
3 months. Graphic LCD display and built-in
LED status indicators and alarms inverter
and software IngeconSun Manager for
confi guration and parameter display and
data logging system.
Standard 3 year warranty, extendable for up to 25 years
An adaptable system for stand-alone grids and microgrids
30 / 60 / 90 / 120
Three phase
Size and weight (mm)
HYBRID MS120 kg. (each module)
65
0
715590
795
Maximum confi guration fl exibility and
installation for stand-alone systems and
hybrids.
Possibility of further expansion of the
system.
Modular system with connectivity modules
for photovoltaic generators, turbine
modules, turbines, battery management
modules and inverter modules.
LCD display graphs co integrated.
Integrated data logger for storing data up
to 3 months.
IngeconSun Manager software for
parameter display and data recording
system.
Monitoring and control system via
Ethernet or RS485 communication
interfaces.
Card GSM / GPRS modem for
communication from remote PC.
Galvanic isolation transformer.
Kit for connecting auxiliary generator.
OPTIONAL ACCESSORIES
FEATURES
ELECTRICAL PROTECTION
Overvoltage protection by varistor
extractable.
Control of PV array Insulation with alarm.
Protection against short circuits and
overloads.
7575
Off-
grid
and
mic
ro-g
rid
inve
rter
s
INGECON® HYBRID MS three phase
1 Module 2 Modules 3 Modules 4 Modules**
PV Module
Number of inputs 3 6 9 12
Power 3 x 15 kW 6 x 15 kW 9 x 15 kW 12 x 15 kW
Voltage range 150 - 700 Vdc 150 - 700 Vdc 150 - 700 Vdc 150 - 700 Vdc
Maximum current for unit 30 A 30 A 30 A 30 A
1 Module 2 Modules 3 Modules 4 Modules**
Wind Turbine ModuleNumber of Inputs 3 6 9 12
Power 3 x 15 kW 6 x 15 kW 9 x 15 kW 12 x 15 kW
Line voltage range 70 - 495 Vac 70 - 495 Vac 70 - 495 Vac 70 - 495 Vac
Maximum line current per input 24 A 24 A 24 A 24 A
1 Module 2 Modules 3 Modules 4 Modules**
Energy Manager ModulePower 30 kW 60 kW 90 kW 120 kW
Battery input voltage 200 - 500 Vdc 200 - 500 Vdc 200 - 500 Vdc 200 - 500 Vdc
Maximum current 100 A 200 A 300 A 400 A
PV Input*
Rated output 1 x 15 kW 1 x 15 kW 1 x 15 kW 1 x 15 kW
Voltage range 150 - 700 Vdc 150 - 700 Vdc 150 - 700 Vdc 150 - 700 Vdc
Maximum current 30 A 30 A 30 A 30 A
1 Module 2 Modules 3 Modules 4 Modules**
Inverter ModuleRated power 30 kVA 60 kVA 90 kVA 120 kVA
Output voltage 380 - 430 Vac (neutro accesible) 380 - 430 Vac (neutral available) 380 - 430 Vac (neutral available) 380 - 430 Vac (neutral available)
Output frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz
THD <4% <4% <4% <4%
Phi Cosine -1 to 1 -1 to 1 -1 to 1 -1 to 1
System Effi ciencyMaximum effi ciency >96%
General InformationAmbient temperature -10ºC to +45ºC
Protection class IP20
Compliance with standards: CE.*Only the fi rst Energy Manager module. **The combination of modules depends on the dimensions of the intallation.
Wiring diagram
AC AC
DC
DC
AC
Wind turbine
PV array
Batteries
Consumption
Public grid
(A generator can be connected
instead of the public grid)
ENERGY MANAGEMENT SOLUTIONS
7878
MINIMUN ELEMENTS FOR
THE CONNECTION DIAGRAM
INGECON® EMS Manager.
INGECON® EMS Power Meter.
Renewable generation
(INGECON® SUN and/or
INGECON® µWIND).
Public grid
INGECON® EMS
Power Meter
Electric vehicle
IngeREV® Garage
INGECON® EMS
Load Control
INGECON® EMS
Load Control
Boiler
Loads
Wind turbine
INGECON® EMS
Manager
INGECON® SUN
Manager
Radiator
INGECON®
EMS HomeINGECON®
SUN 1Play
INGECON®
µWIND
Batteries
PV panel
INGECON® µWIND
Interface
INGECON® EMS
Load Control
AC
AC or DC
DC
INGECON® EMS Home, if off-
grid operation is necessary.
INGECON® EMS Load Control,
for managing the loads.
ADDITIONAL ELEMENTS
Ingeteam Smart HouseComplete self-consumption and energy management solutions for homes and industries
SYSTEM HIGHLIGHTS
Savings in energy consumption.
Optimisation and maximum use
of own production.
Shorter investment pay-back times
for the renewable system.
Customised consumption
strategy adapted to the specifi c
circumstances of each installation.
Easy installation.
7979
Ener
gy m
anag
emen
t sol
utio
ns
The most effi cient energy management solution for self-consumption
This innovative energy management
solution developed by Ingeteam
Power Technology, for the domestic,
commercial and industrial markets,
allows for increased self-consumption,
by matching energy production and
consumption.
The smart energy managerThe INGECON® EMS Manager manages
the connection and disconnection
of controllable loads and energy
generation, based on the power
production data obtained from the
power converters and on total system
consumption. The INGECON® EMS
Manager implements management
strategies based on the different devices
connected to the system, making it
possible to plan how and when to
consume the power produced. The
INGECON® EMS Manager is designed to
optimise any electricity system in terms
of energy usage and cost savings.
Consumption managementConsumption management is the basis
of a truly effective energy management
system. Thanks to the INGECON® EMS
Load Control it is possible to determine
the connection and disconnection times
for the various loads coupled to the
system. This allows for the connection
of electric boilers, radiators, pumps,
electric vehicles etc, constantly
adapting total system consumption to
the renewable energy produced.
Maximum control of the energy consumedThe system energy manager
constantly controls the amount of
energy exchanged with the public
grid. Thanks to the INGECON® EMS
Power Meter, the system constantly
meters the two-way power fl ow
between the grid and the system.
This information is transferred in real
time to the INGECON® EMS Manager.
Furthermore, the INGECON® EMS
Power Meter allows the system to be
decoupled from the grid, to become an
off-grid network. In order to do
so, the INGECON® Home battery
inverter is required, associated with a
storage system.
Continuous communicationThe INGECON® EMS Manager also
acts as a communications centre,
constantly exchanging information with
the INGECON® EMS Power Meter and
the system converters. It also sends
orders to the INGECON® EMS Load
Control through Bluetooth or RS-485 to
control the loads.
EMS Manager
Power supplyInput voltage 100 - 240 Vac
Nominal frequency 50 / 60 Hz
Power consumption 5 - 8 W
ConnectivityEthernet 1
RS-485 1
USB 1
Potential free outputs 2 x (250 V, 6 A)
Communication interface with other equipment
Ingeteam inverters RS-485, Ethernet, Bluetooth
Monitoring systems Ethernet, GPRS
INGECON® EMS Power Meter RS-485
INGECON® EMS Load Control Bluetooth
Size and weight (mm)
280 g.
150
42
110
8080
With transformer
The INGECON® EMS Home two-way inverter
for batteries plays a key role in optimising
production and self-consumption.
Power controlIn combination with INGECON® EMS
Manager it is possible to control the total
power fl ow in the system, by implementing
a number of strategies.
Stand-alone modeIn the event of a grid outage, the
INGECON® EMS Power Meter, in
combination with the INGECON® EMS
Home, decouples the installation from the
public electricity grid, allowing the system
to operate in stand-alone mode.
System of batteriesThe INGECON® EMS Home controls a
two-way storage system that offers greater
possibilities for effectively managing the home-
based generating system. Batteries also play a
key role in those situations in which the system
needs to operate in stand-alone mode.
Maximum integrationThis system makes it possible to combine
the production coming from wind and PV
power sources, being 100% compatible
with the INGECON® SUN 1Play and
INGECON® µWIND inverters. It features
an integrated RS-485 communication
link, and there is also the possibility of
communication via Ethernet or Bluetooth.
Software included It includes, without any extra cost, the
software INGECON® SUN Manager and
INGECON® SUN Monitor for displaying and
recording the data directly from the inverter
through the Internet.
Standard 5 year warranty, extendable for up to 25 years
Energy storage management for maximun effi ciency
2.4 / 3 / 5 / 6
PROTECTIONS
AC overvoltages.
Shortcircuits and overloads
at the output (confi gurable).
Insulation faults.
Galvanic isolation between
the DC and AC sides.
OPTIONAL ACCESSORIES
Remote GSM/GPRS communication
via modem, or Bluetooth.
Confi gurable potential
free contact.
PT100 (3-wire) battery
temperature measurement.
The INGECON® EMS Manager can be confi gured so that zero energy is delivered to the grid.
0:0
0
3.00
2.50
4.00
2.00
3.50
1.50
1.00
0.50
0.00
0:3
0
15
:00
1:0
0
15
:30
1:3
0
16
:00
2:0
0
16
:30
2:3
0
17:0
0
3:0
0
17:3
0
3:3
0
18
:00
4:0
0
18
:30
4:3
0
19
:00
5:0
0
19
:30
5:3
0
20
:00
6:0
0
20
:30
6:3
0
21:0
0
7:0
0
21:3
0
7:3
0
22
:00
8:0
0
22
:30
8:3
0
23
:00
9:0
0
23
:30
9:3
0
10
:00
10
:30
11:0
0
11:3
0
12
:00
12
:30
13
:00
13
:30
14:0
0
14:3
0
Pow
er (
kW)
Injection into the grid
Consumption from the grid
Battery load
Consumption from batteries
Self-consumed power
ACCESSORIES BY DEFAULT
8181
Ener
gy m
anag
emen
t sol
utio
ns
INGECON® EMS Home with transformer
2.4 3 5 6
Battery (DC)
Battery voltage 48 - 250 V 60 - 250 V 96 - 250 V 120 - 250 V
Charge / discharge current 50 A 50 A 50 A 50 A
Battery type Lead, Ni-Cd, Li-ion Lead, Ni-Cd, Li-ion Lead, Ni-Cd, Li-ion Lead, Ni-Cd, Li-ion
Grid (AC)Rated power AC(1) 2.4 kW 3 kW 5 kW 6 kW
AC current 11 A 13 A 22 A 26 A
Rated AC voltage 220 / 230 / 240 / 250 V 220 / 230 / 240 / 250 V 220 / 230 / 240 / 250 V 220 / 230 / 240 / 250 V
Rated AC frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Stand-alone mode (AC)Power AC (25ºC) 30 min, 2 min, 3 s 2,800 / 3,100 / 5,200 W 3,500 / 3,900 / 5,500 W 5,400 / 5,800 / 9,000 W 6,400 / 6,900 / 9,700 W
Effi ciencyMaximum effi ciency 94% 94% 94.5% 94.5%
General InformationStand-by consumption <10 W <10 W <10 W <10 W
Ambient temperature -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95% 0 - 95%
Protection class IP65 IP65 IP65 IP65
Size and weight (mm)
Transformer
5 / 665 kg.
2.4 / 343.3 kg.
47
0
180
360
320
140
32
0
L
N
Inverter
Battery input AC grid
Transformer
Home
Notes: (1) AC power for 40ºC ambient temperature.
Compliance with standards: EN62109-1, EN62109-2, EN61000-6-2, EN61000-6-3, RD1699/2011, VDE-AR-N4105, CEI 11-20, CEI 0-21, Allegato 70 TERNA, CEI 0-16 Ed. III,
VDE0126-1-1, G83/1-1, G83/2.
Public grid
INGECON® EMS
Power Meter
Wind turbine
INGECON® EMS
Manager
INGECON®
SUN 1Play
PV array
AC
AC or DC
AC network in
back-up mode
DC
Batteries
Radiator
Filt
er
BoilerINGECON®
EMS HomeINGECON®
µWIND
INGECON® µWIND
Interface
8282
Transformerless
2.4TL / 3TL / 5TL / 6TL
Energy storage management for maximun effi ciency
PROTECTIONS
AC overvoltages.
Shortcircuits and overloads at the
output (confi gurable).
Insulation faults.
Galvanic isolation between the DC
and AC side.
OPTIONAL ACCESSORIES
Remote GSM/GPRS communication
via modem.
Confi gurable potential
free contact.
The INGECON® EMS Manager can be confi gured so that zero energy is delivered to the grid.
0:0
0
3.00
2.50
4.00
2.00
3.50
1.50
1.00
0.50
0.00
0:3
0
15
:00
1:0
0
15
:30
1:3
0
16
:00
2:0
0
16
:30
2:3
0
17:0
0
3:0
0
17:3
0
3:3
0
18
:00
4:0
0
18
:30
4:3
0
19
:00
5:0
0
19
:30
5:3
0
20
:00
6:0
0
20
:30
6:3
0
21:0
0
7:0
0
21:3
0
7:3
0
22
:00
8:0
0
22
:30
8:3
0
23
:00
9:0
0
23
:30
9:3
0
10
:00
10
:30
11:0
0
11:3
0
12
:00
12
:30
13
:00
13
:30
14:0
0
14:3
0
Pow
er (
kW)
Injection into the grid
Consumption from the grid
Battery load
Consumption from batteries
Self-consumed power
The INGECON® EMS Home two-way inverter
for batteries plays a key role in optimising
production and self-consumption.
Power controlIn combination with INGECON® EMS
Manager it is possible to control the total
power fl ow in the system, by implementing
a number of strategies.
Stand-alone modeIn the event of a grid outage, the
INGECON® EMS Power Meter, in
combination with the INGECON® EMS
Home, decouples the installation from the
public electricity grid, allowing the system
to operate in stand-alone mode.
System of batteriesThe INGECON® EMS Home controls a
two-way storage system that offers greater
possibilities for effectively managing the home-
based generating system. Batteries also play a
key role in those situations in which the system
needs to operate in stand-alone mode.
Maximum integrationThis system makes it possible to combine
the production coming from wind and PV
power sources, being 100% compatible
with the INGECON® SUN 1Play and
INGECON® µWIND inverters. It features
an integrated RS-485 communication
link, and there is also the possibility of
communication via Ethernet or Bluetooth.
Software included It includes, without any extra cost, the
software INGECON® SUN Manager and
INGECON® SUN Monitor for displaying and
recording the data directly from the inverter
through the Internet.
Standard 5 year warranty, extendable for up to 25 years
PT100 (3-wire) battery
temperature measurement.
ACCESSORIES BY DEFAULT
8383
Ener
gy m
anag
emen
t sol
utio
ns
INGECON® EMS Home transformerless
2.4TL 3TL 5TL 6TL
Battery (DC)
Battery voltage 48 - 250 V 60 - 250 V 96 - 250 V 120 - 250 V
Charge / discharge current 50 A 50 A 50 A 50 A
Battery type Lead, Ni-Cd, Li-ion Lead, Ni-Cd, Li-ion Lead, Ni-Cd, Li-ion Lead, Ni-Cd, Li-ion
Grid (AC)Rated power AC(1) 2,4 kW 3 kW 5 kW 6 kW
AC current 11 A 13 A 22 A 26 A
Rated AC voltage 220 / 230 / 240 / 250 V 220 / 230 / 240 / 250 V 220 / 230 / 240 / 250 V 220 / 230 / 240 / 250 V
Rated AC frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Stand-alone mode (AC)Power AC (25ºC) 30 min, 2 min, 3 s 2,800 / 3,100 / 5,200 W 3,500 / 3,900 / 5,500 W 5,400 / 5,800 / 9,000 W 6,400 / 6,900 / 9,700 W
Effi ciencyMaximum effi ciency 95.5% 95.5% 96% 96%
General InformationStand-by consumption <10 W <10 W <10 W <10 W
Ambient temperature -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95% 0 - 95%
Protection class IP65 IP65 IP65 IP65
Notes: (1) AC power for 40ºC ambient temperature.
Compliance with standards: EN62109-1, EN62109-2, EN61000-6-2, EN61000-6-3, RD1699/2011, VDE-AR-N4105, CEI0-21, CEI11-20, VDE0126-1-1, G83/1-1, G83/2.
Home TL Size and weight (mm)
5TL / 6TL23.3 kg.
2.4TL / 3TL18.3 kg.
360
180
47
0
L
N
Inverter
Battery input AC grid
Filt
er
Public grid
INGECON® EMS
Power Meter
Wind turbine
INGECON® EMS
Manager
INGECON®
SUN 1Play
PV array
AC
AC or DC
AC network in
back-up mode
DC
Batteries
Radiator
BoilerINGECON®
EMS HomeINGECON®
µWIND
INGECON® µWIND
Interface
8484
Ingeteam has developed the INGECON® EMS Plants (EMS:
Energy Management Solutions) family of inverters, designed
to integrate energy storage systems into PV plants.
Integration of batteries into PV plantsThe use of energy storage systems at PV plants helps to
improve the integration of solar energy into the electricity
grid, particularly in the case of a weak grid or one with a
high solar energy penetration.
The INGECON® EMS Plants inverters are compatible with
the range of battery technologies currently available, such
as Lead, Ni-Cd, Redox and Lithium, ensuring that the
most suitable technology can be used for each specifi c
application.
The use of energy storage systems makes it possible to
implement different plant operating strategies, such as
the control of the plant power output variability or the
generation of a constant power output.
Control of the power output variabilityThe variation in irradiance caused by passing clouds
produces power output variations that can be as great as
80% of the rated power of the plant per minute, depending
on the size of the plant and the weather conditions at the site.
The use of INGECON® EMS Plants inverters, together
with their corresponding batteries, makes it possible to
reduce the dynamics of these variations and to adapt to
the requirements imposed by grid operators, improving the
quality of supply and ensuring the high integration of solar
energy into the electricity system.
An energy storage system makes it possible to control the
plant power output ramps, based on pre-established values.
Whenever a cloud passes over, with the subsequent loss of
irradiance, the storage system provides the energy required
to offset the energy shortfall, whilst the power output is
progressively reduced until it is equal to the PV power. Once
the cloud has gone, the available power increases sharply
and this is used to charge the batteries whilst smoothly
increasing the power output.
Smart solutions for seamless integration into the electricity grid
Power management at PV plants with an energy storage system
Acciona PV Plant with an INGECON® EMS 1000 D400 DC Indoor
8585
Ener
gy m
anag
emen
t sol
utio
ns
High penetration for diesel-PV hybrid plantsWhat is more, the INGECON® EMS Plants inverters can
be used to support diesel-PV hybrid systems, to achieve
high PV penetration levels. In this way, the PV production
variations caused by passing clouds are offset with the
power supplied from the storage systems, thereby allowing
greater response time to either vary the diesel load
balance system or to start up new generators. This is of
particular interest to systems comprising a number of diesel
generators operating in parallel, allowing some of the units
to be disconnected when PV energy is being produced.
Solutions availableIngeteam has developed two different strategies for
integrating PV production, energy storage and the delivery
of power to the grid:
Distributed topology
Indoor inverters with an integrated DCAC cabinet.
Indoor inverters with a DC cabinet.
Outdoor inverters with an integrated DCAC cabinet.
Integrated topology
Indoor inverters with an integrated DCAC cabinet.
Indoor inverters with a DC cabinet.
Outdoor inverters with an integrated DCAC cabinet.
Distributed topologyBased on conventional grid-connected inverters for PV
generation and dedicated inverters to connect the batteries
to the electricity grid. This option can be installed in PV
plants that are already operating. It also offers the possibility
of providing reactive energy with the battery inverters,
thereby avoiding the need to over-size the PV inverters
should there be strict reactive power delivery requirements.
For this topology, a plant controller manages the energy
fl ow between the grid and the batteries, adjusting the plant
generation to a pre-established pattern.
Integrated topologyThis option, patented by Ingeteam (Patent pending
WO2012020148), comprises a PV inverter and a DC/DC
converter, battery charger in a single unit. This topology
is particularly recommended for small plants, as it avoids
the redundancy of the medium voltage transformer at the
output and offers the possibility of incorporating energy
control and management strategies in the actual converter,
thereby simplifying the installation.
Example of the system performance in the face of an 80%/min fl uctuation in irradiance (up and down), in accordance with the 10%/min output power variation requirement.
P EMSP FV
100%
20%
Pcha ~ Pdis/3
Battery State of Charge
Pdischarge
P bat
SOC
P out
1 min
8 min 24 min
1 min t
t
t
Constant power control. Shifting the power curveWith the INGECON® EMS Plants inverters, it is also possible
to control the plant output power to ensure that this remains
at a constant, pre-determined value. This value can be
calculated on the basis of grid operator requirements or
weather forecasts. Furthermore, the power curve can be
shifted if required by the grid operator.
8:30 9:30 10:30 11:30 12:30 13:30 14:30 15:30 16:30 17:30 18:30
Regulated output powerAvailable PV power
Output power at an actual 1 MW PV plant on a day with scattered clouds, with and without energy storage systems, implementing constant power control.
Output power at an actual 1 MW PV plant on a day with scattered clouds, with and without energy storage systems, implementing constant power control.
%
8:4
6
120
100
80
60
40
20
0
9:1
2
9:3
8
10
:04
10
:30
10
:56
11:2
2
11:4
8
12
:14
12
:40
13
:06
13
:32
13
:58
14
:24
14
:50
15
:16
15
:42
16
:08
16
:34
17:0
0
17:2
6
17:5
2
18
:18
18
:44
19
:10
19
:36
20
:02
20
:28
20
:54
21:2
0
8686
The INGECON® EMS Plants battery
inverter family operates in a wide range of
output voltages: 220, 275, 300, 320, 345,
360 and 400 Vac. For any of the operating
voltages, these inverters have from
two to four independent power blocks.
Distributed topologyThis topology contemplates a power
converter dedicated to each ESS. This
converter delivers direct current to
the batteries for charging purposes
Battery inverters with a DCAC cabinet
whilst it feeds alternating current into
the grid when it discharges the ESS.
The battery inverter either delivers
or absorbs the power required to
ensure that the overall plant power is
controlled. The equipment can change
from charging to discharging the
batteries in a matter of seconds.
Performance qualitiesFor this topology, a plant controller
manages the energy fl ow between the
grid and the batteries, adjusting the
plant generation to a pre-established
pattern. Therefore, the plant controller
is responsible for adding up the power
outputs from the PV inverters and for
calculating the power received by the
battery inverters as a set point.
Standard 5 year warranty, extendible up to 25 years
Distributed topology
Indoor
Distributed topology DCAC
M
+1
-1
Inverter
Filt
er
Filt
er
Inverter
AC output for
connection to a
MV network
L1L2L3
Optional
Size and weight (mm)
4 blocks Indoor2,500 kg.
3 blocks Indoor1,900 kg.
2 blocks Indoor1,300 kg.
2,0
40
2,310
925
2,0
40
2,910
925
2,0
40
3,510
925
2,1
40
2,310
1,000
2 blocks Outdoor1,500 kg.
3 blocks Outdoor2,050 kg.
4 blocks Outdoor2,700 kg.
2,1
40
3,510
1,000
2,1
40
2,910
1,000
8787
Ener
gy m
anag
emen
t sol
utio
ns
Available in a DC versionThis model has no AC cabinet and
therefore takes up less space. This
is a fl exible solution, particularly
suited to medium voltage transformer
substations with two inverters. The
construction of enclosures to house
a number of inverters, maximises the
investment made.
System highlightsThis topology can be installed in PV
plants that are already operating. It is
also possible to provide reactive energy
with the battery inverters, thereby
avoiding the need to over-size the PV
inverters should there be strict reactive
power delivery requirements.
Software includedThe INGECON® SUN Manager and
INGECON® SUN Monitor applications
for monitoring and recording the
inverter data over the internet, are
included at no extra cost.
Battery inverters with a DC cabinet
INGECON® EMS Plants
Distributed topology DC
M
Inverter
Inverter
Filt
er
Filt
er
+1
-1
AC output for
connection to a
MV network
L1
L1
L2
L2
L3
L3
Size and weight (mm)
4 blocks Indoor2,100 kg.
3 blocks Indoor1,500 kg.
2 blocks Indoor900 kg.
2,0
40
1,910
925
2,0
40
2,510
925
2,0
40
3,110
925
Protections and communications includedThe INGECON® EMS Plants family has
a low-voltage ride through capability
and is equipped with an active and
reactive power control system. RS-485
communications supplied as standard
for inter-inverter communications, and
inverter monitoring (alarms, real time
production, etc.). Featuring status and
alarm LED indicators and the possibility
of remote control from a PC or local
control from the inverter display.
8888
Distributed topology
DISTRIBUTED TOPOLOGY
This option is based on conventional
grid-connected inverters for the PV
generation and dedicated inverters to
connect the batteries to the electricity
grid. This option can be installed in PV
plants that are already operating.
It offers the possibility of providing
reactive energy with the battery
AC
ACDC
ACDC
INGECON® EMS Plants
INGECON® SUN
INGECON® EMS Plant Manager
inverters, thereby avoiding the need
to over-size the PV inverters should
there be strict reactive power delivery
requirements. For this topology, a plant
controller manages the energy fl ow
between the grid and the batteries,
adjusting the plant generation to a
pre-established pattern.
Public MV Grid
Optional
PV array
Battery Bank
Diesel Generator
OPTIONAL ACCESSORIES
PROTECTIONS
Short-circuits and overloads at
the output.
Anti-islanding with automatic
disconnection.
Isolation monitor.
DC load break switch.
Lightning induced DC and AC
surge arresters, class II.
Inter-inverter communications
via Ethernet, Bluetooth or
GSM/GPRS.
Remote tripping of the AC
protection.
AC thermal-magnetic breaker
with door control (only in
DCAC units).
8989
Ener
gy m
anag
emen
t sol
utio
ns275TL D220 410TL D220 550TL D220
Input (DC) (Battery)
Battery voltage range 370 - 820 V 370 - 820 V 370 - 820 V
Maximum current DC 900 A 1,350 A 1,800 A
Type of battery Li-ion, lead, Ni-Cd
DC connection type Connection to fuse holder copper bars, cable entry from the bottom through D40 cable glands (max. cable diameter: 40 mm)
Input protectionsOvervoltage protections Type 2 DC surge arresters (for each power stage)
DC breaker Motorized DC beraker with door control
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(1) 275 kW 412 kW 550 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 220 V IT System 220 V IT System 220 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(2) 1 1 1
Phi Cosine adjustable Yes. Smax=275 kVA Yes. Smax=412 kVA Yes. Smax=550 kVA
THD (Total Harmonic Distortion)(3) <3% <3% <3%
AC connection type Connection to fuse holder copper bars, cable entry from the bottom through D40 cable glands (max. cable diameter: 40 mm)
Output protectionsOvervoltage protections Type 2 AC surge arresters
AC breaker Optional AC thermal magnetic breaker with door control, motorized or remote trip (only available for DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.1% 98.1% 98.1%
Euroeffi ciency 97.9% 97.9% 97.9%
CEC 97.4% 97.4% 97.4%
Stand-by consumption(4) 120 W 120 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(5) 3,000 m 3,000 m 3,000 m
Cooling system Forced air with temperature control (230 V phase + neutral power supply)
Air volume 2,670 (fans: 1,230 W) 4,640 (fans: 2,050 W) 5,340 (fans: 2,460 W)
Noise emission <55 dB(A) at 4 m and <67 dB(A) at 1 m with fans working at maximum power
Certifi cation CE
EMC & Security standards EN 50178, IEC 61000-6-2, IEC 61000-6-4, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI 0-21, Allegato 70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA, Arrêté 23-04-2008,
IEEE 1547, G59/2
Notes: (1) AC Power for 45ºC ambient temperature. For each ºC of increase, the
output power will be reduced at the rate of 1.8% (2) For Pout>25% of the rated power (3) For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (4) Consumption from PV fi eld (5) Over 1,000 m temperature for rated power (45 ºC) is
reduced at the rate of 4.5 ºC for each 1,000 m.
EMS Plants Distributed topology 220 Vac
Effi ciency INGECON® EMS 550TL D220 Vdc = 500 V
Power (kW)
0 150 350250 450 550
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
50
9090
EMS Plants Distributed topology 275 Vac
350TL D275 520TL D275 695TL D275
Input (DC) (Battery)
Battery voltage range 460 - 820 V 460 - 820 V 460 - 820 V
Maximum current DC 900 A 1,350 A 1,800 A
Type of battery Li-ion, lead, Ni-Cd
DC connection type Connection to fuse holder copper bars, cable entry from the bottom through D40 cable glands (max. cable diameter: 40 mm)
Input protectionsOvervoltage protections Type 2 DC surge arresters (for each power stage)
DC breaker Motorized DC beraker with door control
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(1) 346 kW 519 kW 693 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 275 V IT System 275 V IT System 275 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(2) 1 1 1
Phi Cosine adjustable Yes. Smax=346 kVA Yes. Smax=519 kVA Yes. Smax=693 kVA
THD (Total Harmonic Distortion)(3) <3% <3% <3%
AC connection type Connection to fuse holder copper bars, cable entry from the bottom through D40 cable glands (max. cable diameter: 40 mm)
Output protectionsOvervoltage protections Type 2 AC surge arresters
AC breaker Optional AC thermal magnetic breaker with door control, motorized or remote trip (only available for DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.5% 98.5% 98.5%
Euroeffi ciency 98.2% 98.3% 98.3%
CEC 97.8% 97.9% 97.8%
Stand-by consumption(4) 120 W 120 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(5) 3,000 m 3,000 m 3,000 m
Cooling system Forced air with temperature control (230 V phase + neutral power supply)
Air volume 2,670 (fans: 1,230 W) 4,640 (fans: 2,050 W) 5,340 (fans: 2,460 W)
Noise emission <55 dB(A) at 4 m and <67 dB(A) at 1 m with fans working at maximum power
Certifi cation CE
EMC & Security standards EN 50178, IEC 61000-6-2, IEC 61000-6-4, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI 0-21, Allegato 70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA, Arrêté 23-04-2008,
IEEE 1547, G59/2
Notes: (1) AC Power for 45ºC ambient temperature. For each ºC of increase, the
output power will be reduced at the rate of 1.8% (2) For Pout>25% of the rated power (3) For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (4) Consumption from PV fi eld (5) Over 1,000 m temperature for rated power (45 ºC) is
reduced at the rate of 4.5 ºC for each 1,000 m.
Effi ciency INGECON® EMS 695TL D275 Vdc = 550 V
Power (kW)
0 300 500400 600 700
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
200100
9191
Ener
gy m
anag
emen
t sol
utio
ns
EMS Plants Distributed topology 300 Vac
380TL D300 570TL D300 760TL D300
Input (DC) (Battery)
Battery voltage range 505 - 820 V 505 - 820 V 505 - 820 V
Maximum current DC 900 A 1,350 A 1,800 A
Type of battery Li-ion, lead, Ni-Cd
DC connection type Connection to fuse holder copper bars, cable entry from the bottom through D40 cable glands (max. cable diameter: 40 mm)
Input protectionsOvervoltage protections Type 2 DC surge arresters (for each power stage)
DC breaker Motorized DC beraker with door control
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(1) 378 kW 568 kW 757 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 300 V IT System 300 V IT System 300 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(2) 1 1 1
Phi Cosine adjustable Yes. Smax=378 kVA Yes. Smax=568 kVA Yes. Smax=757 kVA
THD (Total Harmonic Distortion)(3) <3% <3% <3%
AC connection type Connection to fuse holder copper bars, cable entry from the bottom through D40 cable glands (max. cable diameter: 40 mm)
Output protectionsOvervoltage protections Type 2 AC surge arresters
AC breaker Optional AC thermal magnetic breaker with door control, motorized or remote trip (only available for DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.6% 98.6% 98.6%
Euroeffi ciency 98.4% 98.4% 98.4%
CEC 97.9% 97.9% 97.9%
Stand-by consumption(4) 120 W 120 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(5) 3,000 m 3,000 m 3,000 m
Cooling system Forced air with temperature control (230 V phase + neutral power supply)
Air volume 2,670 (fans: 1,230 W) 4,640 (fans: 2,050 W) 5,340 (fans: 2,460 W)
Noise emission <55 dB(A) at 4 m and <67 dB(A) at 1 m with fans working at maximum power
Certifi cation CE
EMC & Security standards EN 50178, IEC 61000-6-2, IEC 61000-6-4, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI 0-21, Allegato 70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA, Arrêté 23-04-2008,
IEEE 1547, G59/2
Notes: (1) AC Power for 45ºC ambient temperature. For each ºC of increase, the
output power will be reduced at the rate of 1.8% (2) For Pout>25% of the rated power (3) For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (4) Consumption from PV fi eld (5) Over 1,000 m temperature for rated power (45 ºC) is
reduced at the rate of 4.5 ºC for each 1,000 m.
Effi ciency INGECON® EMS 760TL D300 Vdc = 550 V
Power (kW)
0 400 600500 700 800
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
100 200 300
9292
EMS Plants Distributed topology 320 Vac
400TL D320 605TL D320 800TL D320
Input (DC) (Battery)
Battery voltage range 540 - 820 V 540 - 820 V 540 - 820 V
Maximum current DC 900 A 1,350 A 1,800 A
Type of battery Li-ion, lead, Ni-Cd
DC connection type Connection to fuse holder copper bars, cable entry from the bottom through D40 cable glands (max. cable diameter: 40 mm)
Input protectionsOvervoltage protections Type 2 DC surge arresters (for each power stage)
DC breaker Motorized DC beraker with door control
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(1) 401 kW 605 kW 803 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 320 V IT System 320 V IT System 320 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(2) 1 1 1
Phi Cosine adjustable Yes. Smax=401 kVA Yes. Smax=605 kVA Yes. Smax=803 kVA
THD (Total Harmonic Distortion)(3) <3% <3% <3%
AC connection type Connection to fuse holder copper bars, cable entry from the bottom through D40 cable glands (max. cable diameter: 40 mm)
Output protectionsOvervoltage protections Type 2 AC surge arresters
AC breaker Optional AC thermal magnetic breaker with door control, motorized or remote trip (only available for DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.7% 98.7% 98.7%
Euroeffi ciency 98.5% 98.5% 98.5%
CEC 97.9% 97.9% 97.9%
Stand-by consumption(4) 120 W 120 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(5) 3,000 m 3,000 m 3,000 m
Cooling system Forced air with temperature control (230 V phase + neutral power supply)
Air volume 2,670 (fans: 1,230 W) 4,640 (fans: 2,050 W) 5,340 (fans: 2,460 W)
Noise emission <55 dB(A) at 4 m and <67 dB(A) at 1 m with fans working at maximum power
Certifi cation CE
EMC & Security standards EN 50178, IEC 61000-6-2, IEC 61000-6-4, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI 0-21, Allegato 70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA, Arrêté 23-04-2008,
IEEE 1547, G59/2
Notes: (1) AC Power for 45ºC ambient temperature. For each ºC of increase, the
output power will be reduced at the rate of 1.8% (2) For Pout>25% of the rated power (3) For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (4) Consumption from PV fi eld (5) Over 1,000 m temperature for rated power (45 ºC) is
reduced at the rate of 4.5 ºC for each 1,000 m.
Effi ciency INGECON® EMS 800TL D320 Vdc = 550 V
0 400 600500 700 800
82
94
88
100
84
96
90
86
98
92
100 200 300
Power (kW)
Effi
cie
ncy
(%)
9393
Ener
gy m
anag
emen
t sol
utio
ns
EMS Plants Distributed topology 345 Vac
440TL D345 660TL D345 880TL D345
Input (DC) (Battery)
Battery voltage range 580 - 820 V 580 - 820 V 580 - 820 V
Maximum current DC 900 A 1,350 A 1,800 A
Type of battery Li-ion, lead, Ni-Cd
DC connection type Connection to fuse holder copper bars, cable entry from the bottom through D40 cable glands (max. cable diameter: 40 mm)
Input protectionsOvervoltage protections Type 2 DC surge arresters (for each power stage)
DC breaker Motorized DC beraker with door control
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(1) 440 kW 660 kW 880 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 345 V IT System 345 V IT System 345 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(2) 1 1 1
Phi Cosine adjustable Yes. Smax=440 kVA Yes. Smax=660 kVA Yes. Smax=880 kVA
THD (Total Harmonic Distortion)(3) <3% <3% <3%
AC connection type Connection to fuse holder copper bars, cable entry from the bottom through D40 cable glands (max. cable diameter: 40 mm)
Output protectionsOvervoltage protections Type 2 AC surge arresters
AC breaker Optional AC thermal magnetic breaker with door control, motorized or remote trip (only available for DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.8% 98.8% 98.8%
Euroeffi ciency 98.6% 98.6% 98.6%
CEC 98% 98% 98%
Stand-by consumption(4) 120 W 120 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(5) 3,000 m 3,000 m 3,000 m
Cooling system Forced air with temperature control (230 V phase + neutral power supply)
Air volume 2,670 (fans: 1,230 W) 4,640 (fans: 2,050 W) 5,340 (fans: 2,460 W)
Noise emission <55 dB(A) at 4 m and <67 dB(A) at 1 m with fans working at maximum power
Certifi cation CE
EMC & Security standards EN 50178, IEC 61000-6-2, IEC 61000-6-4, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI 0-21, Allegato 70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA, Arrêté 23-04-2008,
IEEE 1547, G59/2
Notes: (1) AC Power for 45ºC ambient temperature. For each ºC of increase, the
output power will be reduced at the rate of 1.8% (2) For Pout>25% of the rated power (3) For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (4) Consumption from PV fi eld (5) Over 1,000 m temperature for rated power (45 ºC) is
reduced at the rate of 4.5 ºC for each 1,000 m.
Effi ciency INGECON® EMS 880TL D345 Vdc = 600 V
Power (kW)
0 200 600300 800 900
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
100 700500400
9494
EMS Plants Distributed topology 360 Vac
460TL D360 690TL D360 920TL D360
Input (DC) (Battery)
Battery voltage range 606 - 820 V 606 - 820 V 606 - 820 V
Maximum current DC 900 A 1,350 A 1,800 A
Type of battery Li-ion, lead, Ni-Cd
DC connection type Connection to fuse holder copper bars, cable entry from the bottom through D40 cable glands (max. cable diameter: 40 mm)
Input protectionsOvervoltage protections Type 2 DC surge arresters (for each power stage)
DC breaker Motorized DC beraker with door control
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(1) 458 kW 688 kW 917 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 360 V IT System 360 V IT System 360 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(2) 1 1 1
Phi Cosine adjustable Yes. Smax=458 kVA Yes. Smax=688 kVA Yes. Smax=917 kVA
THD (Total Harmonic Distortion)(3) <3% <3% <3%
AC connection type Connection to fuse holder copper bars, cable entry from the bottom through D40 cable glands (max. cable diameter: 40 mm)
Output protectionsOvervoltage protections Type 2 AC surge arresters
AC breaker Optional AC thermal magnetic breaker with door control, motorized or remote trip (only available for DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.8% 98.8% 98.8%
Euroeffi ciency 98.6% 98.7% 98.7%
CEC 98.1% 98.1% 98.1%
Stand-by consumption(4) 120 W 120 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(5) 3,000 m 3,000 m 3,000 m
Cooling system Forced air with temperature control (230 V phase + neutral power supply)
Air volume 2,670 (fans: 1,230 W) 4,640 (fans: 2,050 W) 5,340 (fans: 2,460 W)
Noise emission <55 dB(A) at 4 m and <67 dB(A) at 1 m with fans working at maximum power
Certifi cation CE
EMC & Security standards EN 50178, IEC 61000-6-2, IEC 61000-6-4, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI 0-21, Allegato 70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA, Arrêté 23-04-2008,
IEEE 1547, G59/2
Notes: (1) AC Power for 45ºC ambient temperature. For each ºC of increase, the
output power will be reduced at the rate of 1.8% (2) For Pout>25% of the rated power (3) For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (4) Consumption from PV fi eld (5) Over 1,000 m temperature for rated power (45 ºC) is
reduced at the rate of 4.5 ºC for each 1,000 m.
Effi ciency INGECON® EMS 920TL D360 Vdc = 625 V
Power (kW)
0 300 700500 900 1000
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
800600400100 200
9595
Ener
gy m
anag
emen
t sol
utio
ns
EMS Plants Distributed topology 400 Vac
Notes: (1) AC Power for 45ºC ambient temperature. For each ºC of increase, the
output power will be reduced at the rate of 1.8% (2) For Pout>25% of the rated power (3) For Pout>25% of the rated power and voltage in accordance with IEC 61000-3-4 (4) Consumption from PV fi eld (5) Over 1,000 m temperature for rated power (45 ºC) is
reduced at the rate of 4.5 ºC for each 1,000 m.
Effi ciency INGECON® EMS 1000TL D400 Vdc = 700 V
Power (kW)
0 300 700500 900 1000
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
800600400100 200
500TL D400 750TL D400 1000TL D400
Input (DC) (Battery)
Battery voltage range 673 - 820 V 673 - 820 V 673 - 820 V
Maximum current DC 900 A 1,350 A 1,800 A
Type of battery Li-ion, lead, Ni-Cd
DC connection type Connection to fuse holder copper bars, cable entry from the bottom through D40 cable glands (max. cable diameter: 40 mm)
Input protectionsOvervoltage protections Type 2 DC surge arresters (for each power stage)
DC breaker Motorized DC beraker with door control
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(1) 510 kW 764 kW 1,019 kW
Maximum current AC 736 A 1,104 A 1,472 A
Rated voltage AC 400 V IT System 400 V IT System 400 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine(2) 1 1 1
Phi Cosine adjustable Yes. Smax=510 kVA Yes. Smax=764 kVA Yes. Smax=1,019 kVA
THD (Total Harmonic Distortion)(3) <3% <3% <3%
AC connection type Connection to fuse holder copper bars, cable entry from the bottom through D40 cable glands (max. cable diameter: 40 mm)
Output protectionsOvervoltage protections Type 2 AC surge arresters
AC breaker Optional AC thermal magnetic breaker with door control, motorized or remote trip (only available for DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.8% 98.8% 98.8%
Euroeffi ciency 98.6% 98.6% 98.6%
CEC 98.1% 98.1% 98.1%
Stand-by consumption(4) 120 W 120 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54 IP20 / IP54
Max. altitude(5) 3,000 m 3,000 m 3,000 m
Cooling system Forced air with temperature control (230 V phase + neutral power supply)
Air volume 2,670 (fans: 1,230 W) 4,640 (fans: 2,050 W) 5,340 (fans: 2,460 W)
Noise emission <55 dB(A) at 4 m and <67 dB(A) at 1 m with fans working at maximum power
Certifi cation CE
EMC & Security standards EN 50178, IEC 61000-6-2, IEC 61000-6-4, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI 0-21, Allegato 70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA, Arrêté 23-04-2008,
IEEE 1547, G59/2
9696
The INGECON® EMS Plants inverter
and battery charger family operates at
two output voltages: 275 and 320 Vac.
Each unit has four modules: three
independent PV converters and one
DC/DC converter connecting the PV
array and the batteries.
Integrated topologyThanks to the fact that the PV
converters and the storage system
management are housed in one
unit, these can operate in automatic
PV inverter and battery charger with a DCAC cabinet
mode: controlling the ESS charge level
and the output power, based on the
regulations in force in each specifi c
country. For correct operation, the
battery voltage range must be lower
than the PV voltage range.
Energy management solutionThe new INGECON® EMS Plants
smooths out any sharp fl uctuations
that may occur in the power output as
a result of solar irradiance variations.
Any excess power is used to charge
Integrated topology DCAC
the ESS whilst, during energy
shortfalls, the batteries delivery energy
to the grid.
Performance qualitiesWhen the battery charger is charging the
ESS, the current fl ows from the PV array
to the battery and inverter, charging the
batteries and delivering power to the
grid. If the converter is drawing power
from the ESS, then the batteries and the
PV array provide the power delivered
by the inverter at the output.
Integrated topology
Indoor
Size and weight (mm)
4 blocks Indoor2,500 kg.
3 blocks Indoor1.900 kg.
2 blocks Indoor1,300 kg.
2,0
40
2,310
925
2,0
40
2,910
925
2,0
40
3,510
925
2,1
40
2,310
1,000
2 blocks Outdoor1,500 kg.
3 blocks Outdoor2,050 kg.
4 blocks Outdoor2,700 kg.
2,1
40
3,510
1,000
2,1
40
2,910
1,000
M
+1
-1
Inverter
Filt
er
Inverter
Filt
er
AC output for
connection to a
MV network
L1L2L3
Optional
+2
+3
-2
-3
...
-16
...+16
Optional
9797
Ener
gy m
anag
emen
t sol
utio
ns
M
Available in a DC versionThis indoor model takes up less space
and optimises investment, given the
fact that it has a smaller footprint,
as no AC cabinet is required. This
is a fl exible solution that optimises
investment through the use of one
enclosure to house a number of units.
Accessibility and safetyThe DC models permit fast, completely
safe access to the DC input cabinet,
thanks to the individual protections
for each power module. The inverter
has three power blocks connected in
parallel to the same PV generator and
to the battery charger module.
Software includedThe INGECON® SUN Manager and
INGECON® SUN Monitor applications
for monitoring and recording the
inverter data over the internet, are
included at no extra cost.
Protections and communications includedThe INGECON® EMS Plants family has
a low-voltage ride through capability
and is equipped with an active and
reactive power control system. RS-485
communications supplied as standard
for inter-inverter communications,
and inverter monitoring (alarms,
real time production, etc.). Featuring
status and alarm LED indicators and
offering the possibility of remote
control from a PC or local control from
the inverter display.
Standard 5 year warranty, extendable for up to 25 years
PV inverter and battery charger with a DC cabinet
INGECON® EMS Plants
Integrated topology DC
Inverter-16
L1
Inverter
Filt
er
Filt
er
+16...
+3
+2
+1
-1
-2
-3
...
AC output for
connection to a
MV network
L1
L2
L2
L3
L3
Size and weight (mm)
4 blocks Indoor2,100 kg.
3 blocks Indoor1,500 kg.
2 blocks Indoor900 kg.
2,0
40
1,910
925
2,0
40
2,510
925
2,0
40
3,110
925
9898
Integrated topology
INTEGRATED TOPOLOGY
PROTECTIONS
Short-circuits and overloads at the
output.
Anti-islanding with automatic
disconnection.
DC insulation monitor.
Lightning induced DC and
AC surge arresters, class II.
OPTIONAL ACCESSORIES
Inter-inverter communications via
Ethernet, Bluetooth or
GSM/GPRS.
Remote tripping of the AC
protection.
DC breaker with door control.
AC thermal-magnetic breaker with
door control (only in DCAC units).
Battery
Voltage Range
PV
Voltage Range
MPP
820 V 1,000 V460 V
VOLTAGE OPERATION RANGE
In this option, patented by Ingeteam, the
PV inverter and the battery inverter are
housed in a single unit. This INGECON®
EMS Plants topology comprises a two-
way DC/DC converter connecting the PV
array and the ESS.
AC
AC
DC
PV array
Battery Bank
Diesel Generator
Public MV Grid
Optional
9999
Ener
gy m
anag
emen
t sol
utio
ns520TL I275 605TL I320
Input (DC) (PV fi eld)
Recommended PV array power range(1) 531 - 650 kW 615 - 780 kW
Maximum voltage MPP 820 V 820 V
Maximum voltage DC(2) 1,000 V 1,000 V
Maximum current DC 1,350 A 1,350 A
Fuse size for each DC input 125 A/1000 V to 250 A/1000 V fuses, maximum current 100 A to 200 A for positive and negative poles (only available for DCAC models)
DC connection type Connection to fuse holder copper bars, cable entry from the bottom through D40 cable glands (max. cable diameter: 40 mm)
Input (DC) (Battery)
Minimum battery voltage 460 V 540 V
Charging/discharging power 156 kW 200 kW
Type of battery Li-ion, lead, Ni-Cd
Input protectionsOvervoltage protections Type 2 DC surge arresters (for each power stage)
DC breaker Motorized DC beraker with door control
Other protections Up to 16 pairs of DC fuses, DC insulation monitor with alarm, emergency pushbutton
Output (AC)Rated power AC(3) 519 kW 605 kW
Maximum current AC 1,104 A 1,104 A
Rated voltage AC 275 V IT System 320 V IT System
Frequency AC 50 / 60 Hz 50 / 60 Hz
Phi Cosine(4) 1 1
Phi Cosine adjustable Yes. Smax=519 kVA Yes. Smax=605 kVA
THD (Total Harmonic Distortion)(5) <3% <3%
AC connection type Connection to fuse holder copper bars, cable entry from the bottom through D40 cable glands (max. cable diameter: 40 mm)
Output protectionsOvervoltage protections Type 2 AC surge arresters
AC breaker Optional AC thermal magnetic breaker with door control, motorized or remote trip (only available for DCAC models)
Anti-islanding protection Yes, with automatic disconnection (for each power stage)
Other protections AC fuses, AC short circuits and overloads (for each power stage)
FeaturesMaximum effi ciency 98.5% 98.5%
Euroeffi ciency 98.3% 98.3%
CEC 97.9% 97.9%
Stand-by consumption(6) 120 W 120 W
General InformationAmbient temperature -20ºC to +65°C -20ºC to +65°C
Relative humidity (non-condensing) 0 - 95% 0 - 95%
Protection class IP20 / IP54 IP20 / IP54
Max. altitude(7) 3,000 m 3,000 m
Cooling system Forced air with temperature control (230 V phase + neutral power supply)
Air volume 5,340 (fans: 2,460 W) 5,340 (fans: 2,460 W)
Noise emission <55 dB(A) at 4 m and <67 dB(A) at 1
Certifi cation CE
EMC & Security standards EN 50178, EN 61000-6-2, EN 61000-6-4, FCC Part 15
Grid connection standards BDEW MT, RD 661/2007, P.O.12.3, CEI 11-20, CEI 0-21, Allegato 70 TERNA, CEI 0-16 Ed. III, Allegato 68 TERNA, Arrêté 23-04-2008,
IEEE 1547, G59/2
Notes: (1) Depending on the type of installation and geographical location. Data for STC
conditions (2) Consider the voltage increase of the ‘VOC’ at low temperatures (3) AC
Power for 45ºC ambient temperature. For each ºC of increase, the output power will
be reduced at the rate of 1.8% (4) For Pout>25% of the rated power (5) For Pout>25% of
the rated power and voltage in accordance with IEC 61000-3-4 (6) Consumption from
PV fi eld (7) Over 1,000 m temperature for rated power (45 ºC) is reduced at the rate of
4.5 ºC for each 1,000 m.
EMS Plants Integrated topology
Effi ciency INGECON® EMS 605TL I320 Vdc = 500 V
Power (kW)
0 200 400300 500 600
Effi
cie
ncy
(%)
82
94
88
100
84
96
90
86
98
92
100
100100
PV plant control system
The INGECON® EMS Plant Manager
helps the grid operator to predict
the PV plant performance and to
guarantee the quality and stability of
the electricity supply.
Maximum PV plant controlAn advanced control algorithm
combined with a fast and effi cient
communications system, with
response times of less than one
second, permit precise control of the
active and reactive power delivered by
the plant to the grid.
The INGECON® EMS Plant Manager
controls the PV inverters, ensuring
compliance with the grid operator’s
requirements at the PV plant
connection point. It is also possible
to manage energy storage systems
and other devices such as diesel
generators, through the use of
INGECON® EMS Plants inverters.
This is a fl exible system that can
easily be adapted to the needs and
confi gurations of each particular plant,
whilst complying with the country-
specifi c standards and regulations.
Description of the complete systemA PV plant with plant controller
typically consists of:
INGECON® EMS Plant Manager:
comprising two basic systems:
measurement and control. It
can additionally incorporate a
communication channel with the
grid operator in order to receive the
operating setpoints.
INGECON® SUN PV inverters
connected to the PV array.
INGECON® EMS Plants battery
inverters connected to the energy
storage system. Only when energy
storage systems are required to
cover situations in which the solar
radiation is too low or to provide
energy for night-time use.
SCADA, plant monitoring system.
Communications network:
Connecting the INGECON® EMS
Plant Manager with the different
inverters, transmitting the operating
setpoints and monitoring the status
of the equipment.
Continuous communicationwith all devicesThe INGECON® EMS Plant Manager
permits the dynamic modifi cation of
the grid operator setpoints. For this
purpose, a number of communication
protocols are incorporated such
as Modbus TCP/RTU, IEC 61850,
IEC 60870-5-101 and IEC 60870-
5-104. Likewise, it is equipped with
confi gurable digital and analogue input
modules to transmit the setpoints.
Furthermore, the INGECON® EMS
Plant Manager permits communication
with the plant SCADA to transmit the
connection point data.
ITEMS INCLUDED
PLC.
Wattmeter.
Communications switch.
Power supply.
Protections.
SYSTEM HIGHLIGHTS
Frequency regulation.
Active power reserve regulation.
Constant active power level at the output.
Active power ramp regulation.
Reactive power control.
Power factor control.
Voltage control.
101101
Ener
gy m
anag
emen
t sol
utio
ns
Operating modeFor the control, the INGECON® EMS
Plant Manager takes the following data:
Active power, reactive power,
voltage and frequency at the
connection point, provided by the
integrated measurement unit.
Grid operator requirements. To
establish references for parameters
such as voltage at the point of
connection, active and reactive
power, power ramps, active power
reserve, etc. These requirements
can be predetermined either by
the grid operator or by the plant
operator or dynamically modifi ed
through an external setpoint.
Instantaneous active and reactive
power values for the various
inverters.
With all this data, the control unit can
determine the operating setpoints
for each inverter integrated into the
system and transmit the setpoints
through the communications network.
Active power controlSome of the active power control
functions that can be implemented in
the INGECON® EMS Plant Manager are:
Continuous control of the power
at the output. To control the PV
plant power output, limiting it to the
desired value.
Regulation of the active power
variation rate. To control the power
generated by the inverters, ensuring
that the variation in the plant power
output conforms to the established
setpoint. So as to control variations
in power shortfalls, it is necessary
to add energy storage systems and
INGECON® EMS Plants inverters to
the plant in order to deliver energy
to the system when no PV resources
are available.
Power regulation in the event of a
frequency variation.
Active power reserve. The
INGECON® EMS Plant Manager
incorporates a patented
innovative control strategy (PCT/
ES 2008/000560) to guarantee
an active power reserve with no
need to include storage systems
(depending on the availability of the
PV resource).
Reactive power controlSome of the reactive power control
functions that can be implemented in
the INGECON® EMS Plant Manager are:
Regulation of the reactive power
output. To control the plant reactive
power output, adjusting it to a given
reference, including the possibility
of providing reactive power at night
time.
Regulation of the power factor at the
connection point.
Voltage control The INGECON® EMS
Plant Manager controller makes it
possible to regulate the plant voltage
at the connection point.
EMS Plant Manager
Diesel Generator
DC
Battery Bank
DC
INGECON® SUN
INGECON® EMS Plant Manager
Public Grid
AC
AC
INGECON® EMS
AC
Campo fotovoltaico
GRID OPERATOR
Optional
Optional
SCADA
MICRO-WIND INVERTERS
104104
OPTIONAL ACCESSORIES
DC load break switch.
Conversion device AC / DC and protection of system IngeconR ìWind Interface (IWI).
Option kit for auxiliary power extension range of input voltage.
Connection between inverter and PC communication Local via Ethernet or Bluetooth.
Ethernet card or GSM / GPRS modem for remote communication.
Quick Connectors Plugs and Sockets type 4 and fl ying female connector RS485.
Potential-free relay output for signaling.
Alarm or inverter connected to the network.
Kit for connecting auxiliary generator.
Maximum energy extraction at all timesDesigned to control and convert the
energy captured and deliver it to a single
phase grid. Adaptable to suit a wide range
of wind turbines from 2.5 to 5 kW.
They are equipped with
an advanced tracking system
of maximum power point tracking (MPPT)
to ensure maximum extraction of
energy of wind turbine in compliance
regulations. They can be
installed alone or in combination with
the conversion device AC / DC and
protection Ingecon® μWind Interface.
Easy to installFast on connectors for the DC and AC
sides, and RS-485 communications.
No additional items required.
Manual grid disconnection feature and
protection Ingecon® μWind Interface.
Compact, lightweight design with
aluminum enclosure suitable for
installation in any indoor or outdoor,
designed to withstand extreme
temperatures.
Ease of maintenanceInternal datalogger for up to 3 months
data storage, which can be controlled from
either a remote PC or on-site from the
inverter front keypad. LED status
and alarm indicators and LCD screen.
Useful life of more than 20 years.
Standard 5 year warranty, extendable for up to 25 years
The best option for managing and isolating small micro-wind systems
2.5 / 3.3 / 5
With transformer
Transformer
47
0
180
360
320
140
32
0
50
65
80
95
85
70
100
90
75
1 1.50.5 2 2.5 3.53 4 4.5
Power (kW)
Effi
cie
ncy
(%)
EFFICIENCY
INGECON® μWIND 5
Vdc = 330 V
FEATURES
Maximum effi ciency of 97%.
Adaptable to a wide range of wind turbines with powers between 2 and 5 kW.
Ease of installation.
Protection class IP65.
Integrated RS485 interface for communication between inverter or local PC.
LCD display graphs integrated.
Integrated data logger for storing data up to 3 months.
Software Ingecon®Sun Manager to display parameters and data recording.
Displaying data via portal Web IngeRAS™ PV.
Compliant with the relevant guidelines for low and
the average voltage.
2,543,3 kg.
3,344,7 kg.
565 kg.
Size (mm) and weightELECTRICAL PROTECTION
Surge Protection AC and DC side varistors Class III extractable with signaling.
Protection against reverse polarity.
Control of DC insulation with alarm.
Anti-islanding with automatic disconnection.
Protection against short circuits and overloads.
105105
Mic
ro-w
ind
inve
rter
s
INGECON® μWIND with transformer
2.5 3.3 5
Input (DC)
Voltage range MPP 40 - 450 V 40 - 450 V 40 - 550 V
Maximum voltage DC(1) 550 V 550 V 550 V
Maximum current DC 16 A 22 A 33 A
MPPT 1 1 1
Output (AC)Rated power AC(2) 2.7 kW 3.7 kW 5.5 kW
Maximum current AC 12 A 16 A 22 A
Rated voltage AC 230 V 230 V 230 V
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine 1 1 1
Phi Cosine adjustable Yes. Smax=2.7 kVA Yes. Smax=3.7 kVA Yes. Smax=5.5 kVA
THD 3% 3% 3%
Effi ciencyMaximum effi ciency 94.7% 95% 95.1%
Euroeffi ciency 93.8% 94% 94.3%
General InformationStand-by consumption <10 W <10 W <10 W
Ambient temperature -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95%
Protection class IP65 IP65 IP65
Compliance with standards: EN50178, EN61000-6-2, EN61000-6-3, EN62109-1-2, VDE-AR-N 4105, G83/1-1, G83/2, CEI 11-20, CEI 0-21, Allegato 70 TERNA, CEI 0-16 Ed. III, RD1699/2011,
VDE0126-1-1, EN50438, CE Mark.
Notes: (1) Never exceed 550 V. With no auxiliary supply, the minimum start-up voltage is 80 V (2) AC Power for 45ºC ambient temperature. For each ºC of increase, the output power will be
reduced at the rate of 1.8%.
INGECON® μWIND
Wind turbine
Public grid
Wiring diagramwithout INGECON® μWIND Interface
Wiring diagramwith INGECON® μWIND Interface
Wind turbine
Heating
resistor(optional)
Public grid
INGECON® μWIND Interface INGECON® μWIND
ACDC
ACDC
AC
DC
106106
Maximum energy extraction at all timesDesigned to control and convert the
energy captured and deliver it to a single
phase grid. Adaptable to suit a wide range
of wind turbines from 2.5 to 6 kW.
They are equipped with an advanced
tracking system the maximum power
point tracking (MPPT) to ensure
maximum extraction of energy
dall’aerogeneratore in compliance
regulations. They can be installed alone
or in combination with the conversion
device AC / DC and protection Ingecon®
μWind Interface.
Easy to installFast on connectors for the DC and AC
sides, and RS-485 communications.
No additional items required. Manual
grid disconnection feature.
Ease of maintenanceInternal datalogger for up to 3 months
data storage, which can be controlled
from either a remote PC or on-site from
the inverter front keypad. LED status
and alarm indicators and LCD screen.
Useful life of more than 20 years.
Standard 5 year warranty, extendable for up to 25 years
The best option for managing and isolating small micro-wind systems
2.5TL / 3TL / 3.3TL / 3.68TL / 3.8TL / 4.6TL / 5TL / 6TL
Transformerless
DC load break switch.
Conversion device AC / DC and protection of system IngeconR μWind Interface (IWI).
Option kit for auxiliary power extension range of input voltage.
Connection between inverter and PC communication Local via Ethernet or Bluetooth.
Ethernet card or GSM / GPRS modem for remote communication.
Quick Connectors Plugs and Sockets type 4 and fl ying female connector RS485.
Potential-free relay output for signaling
Alarm or inverter connected to the network (optional).
Kit for connecting auxiliary generator.2.5TL / 3TL18.3 kg.
3.3TL / 3.68TL19.7 kg.
3.8TL / 4.6TL / 5TL / 6TL23.3 kg.
Size and weight (mm)
360
180
47
0
4.5 5
EFFICIENCY
0
75
83
95
85
78
100
98
93
88
90
80
1 1.50.5 2 2.5 3.53 4
Effi ciency (%)
Effi
cie
ncy
(%)
INGECON® μWIND 5TL
Vdc = 330 V
FEATURES
Maximum effi ciency of 97%.
Adaptable to a wide range of wind turbines with powers between 2 and 6 kW.
Ease of installation.
Protection class IP65.
Integrated RS485 interface for communication between inverter or local PC.
LCD display graphs integrated.
Integrated data logger for storing data up to 3 months.
Software Ingecon®Sun Manager to display parameters and data recording.
Displaying data via portal Web IngeRAS™ PV.
Compliant with the relevant guidelines for
low and the average voltage.
OPTIONAL ACCESSORIES
Surge Protection AC and DC side varistors Class III extractable with signaling.
Protection against reverse polarity.
Control of DC insulation with alarm.
Anti-islanding with automatic disconnection.
Protection against short circuits and overloads.
ELECTRICAL PROTECTION
107107
Mic
ro-w
ind
inve
rter
s
INGECON® μWIND transformerless
2.5TL 3TL 3.3TL 3.68TL 3.8TL 4.6TL 5TL 6TL
Input (DC)
Voltage range MPP 40 - 450 V 40 - 450 V 40 - 450 V 40 - 450 V 40 - 450 V 40 - 450 V 40 - 450 V 40 - 450 V
Maximum voltage DC(1) 550 V 550 V 550 V 550 V 550 V 550 V 550 V 550 V
Maximum current DC 16 A 16 A 22 A 22 A 33 A 33 A 33 A 33 A
MPPT 1 1 1 1 1 1 1 1
Output (AC)Rated power AC(2) 2.5 kW 3 kW 3.3 kW 3.68 kW 3.8 kW 4.6 kW 5 kW 6 kW
Maximum current AC 13 A 13.5 A 17 A 17 A 18.8 A 24.2 A 25.5 A 26.2 A
Rated voltage AC 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V
Frequency AC 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Phi Cosine 1 1 1 1 1 1 1 1
Phi Cosine adjustable Yes. Smax=2.7 kVA Yes. Smax=3 kVA Yes. Smax=3.7 kVA Yes. Smax=3.68 kVA Yes. Smax=3.9 kVA Yes. Smax=5 kVA Yes. Smax=5.5 kVA Yes. Smax=6 kVA
THD 3% 3% 3% 3% 3% 3% 3% 3%
Effi ciencyMaximum effi ciency 96.6% 96.6% 96.8% 96.8% 97% 97% 97% 97%
Euroeffi ciency 95% 95.1% 95.2% 95.2% 95.6% 96% 96.1% 96.1%
General InformationStand-by consumption <10 W <10 W <10 W <10 W <10 W <10 W <10 W <10 W
Ambient temperature -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC -20ºC to +70ºC
Relative humidity (non-condensing) 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95% 0 - 95%
Protection class IP 65 IP 65 IP 65 IP 65 IP 65 IP 65 IP 65 IP 65
Compliance with standards: EN50178, EN61000-6-2, EN61000-6-3, EN62109-1-2, VDE-AR-N 4105, G83/1-1, G83/2, CEI 11-20, CEI 0-21, Allegato 70 TERNA, CEI 0-16 Ed. III,
RD1699/2011, VDE0126-1-1, EN50438, CE Mark.
Notes: (1) Never exceed 550 V. With no auxiliary supply, the minimum start-up voltage is 80 V (2) AC Power for 45ºC ambient temperature. For each ºC of increase, the output power will be
reduced at the rate of 1.8%.
INGECON® μWIND
Wind turbine Public grid
Wiring diagramwithout INGECON® μWIND Interface
Wiring diagramwith INGECON® μWIND Interface
Wind turbine
Heating
resistor(optional)
Public grid
INGECON® μWIND Interface INGECON® μWIND
ACDC
ACDC
AC
DC
108108
Maximum protection and safetyfor the wind turbine and inverterThe μWind Interface provides overpower
and overvoltage protection for the inverter
whilst also protecting the wind turbine
against overspeeding through a PWM
progressive braking system with a high
capacity discharge resistor. It extends
the wind turbine operating range to
include high wind speeds, for increased
productivity.
Greater control featuresRemote control and additional monitoring
of meteorological variables. Measurement
of the wind turbine speed of rotation.
Remote operation of the wind turbine
start – stop system.
Suitable for wind turbines with AC or DC outputsAC/DC conversion between the wind
turbine output and the inverter input.
Also valid for DC wind turbines.
Standard 5 year warranty, extendable for up to 25 years
System protection and AC/DC conversion in a single unit
PROTECTIONS
Surge Protection.
Overspeed protection of wind
turbine.
Braking system with progressive
dissipation of the excess energy
of external resistors.
OPTIONAL
Two 0-24 V digital inputs.
Two digital outputs, of type NO
potential free contact and with an
opening capacity of 250 V/2 A.
Interface
Input values
Power range 2.5 - 18 kW
Maximum AC voltage 450 Vrms
Maximum AC current 23 Arms
Maximum DC voltage 600 V
Maximum DC current 30 A
Wind turbine speed
capture range(1)
0 - 600 rpm
Analog inputsNumber 2
Type 0 - 10 V / 0 - 20 mA (confi gurable)
General informationCommunication system RS-485 y bus CAN
Remote control system Through Ethernet and PC application
109109
Mic
ro-w
ind
inve
rter
s
Notes: (1) The maximum limit will depend on the electrical characteristics of the wind turbine.
Compliance with standards: EN 50178, EN61000-6-2, EN61000-6-3, CE Mark.
Size and weight (mm)
INGECON® μWIND Interface
Interface7 kg.
32
0
155
345
Wiring diagram
Wind turbine
INGECON® μWIND
INGECON® μWIND Interface
Interlocking
contactors
Rectifi er
Braking
resistors
Public grid
Accesories
MULTI-OPTIONS FOR PV PLANT CONTROL AND MONITORING
112112
A PC can be used to establish
communications remotely with the
PV inverters in order to control all
the PV plant variables (inverter
operating parameters and data log).
This communication is made possible
through a number of cards that can be
incorporated into the inverter.
A range of PC-to-inverter communication options
Specifi cally, the Bluetooth card offers
the possibility of creating communication
networks between several inverters,
and also communications via Bluetooth
with a PC located in the vicinity. Another
possibility is to use Bluetooth to connect to
the INGECON® SUN ComBox which can
then remotely connect to a PC over the
Internet. Repeater stations facilitate the
connection via Bluetooth when there are
obstacles such as walls or roofs.
Cost saving.
Wireless communication.
Easy to install. No need to chip into walls
and then plaster over.
ADVANTAGES OF THE BLUETOOTH COMMUNICATION
113113
Acce
sori
es
1
2
3
4
5
6
Fibre optics boardImmune to atmospheric
conditions.
RS-485 cardQuick connector for easy
inter-inverter connection.
Bluetooth cardTo create a communication
network between several
inverters and a PC; or between
several inverters the INGECON®
SUN ComBox and a PC. It
includes conversion to RS-485.
Ethernet cardFor communicating with the
inverters via Ethernet. It includes
conversion to RS-485.
GSM/GPRS modem cardFor remote communication with
the inverters over the GSM/GPRS
network. It includes conversion
to RS-485.
Wireless cardFor local wireless communication
on the ISM 868 band.
1
2
5
4
3
6
114114
analogue input data storage and
reading functions are far more accurate
than those of standard cards.
The following inputs are available:
2 inputs for PT100.
4 inputs 0..10 V or 0..20 mA.
Media converterFor added versatility when selecting the
means of communication with the plant.
Power setpoint controlDue to the need to improve the grid
integration of the energy generated
Communications centre
The INGECON® SUN ComBox enables
remote communication with the
inverters in a number of standards,
thanks to its versatility to jointly
process data coming from Ethernet,
RS-485, GSM/GPRS, radio or
Bluetooth networks.
The datalogger is able to store
meteorological information and power
setpoint data for one month.
Measurement of meteorological variablesFor the measurement of meteorological
variables, the INGECON® SUN ComBox
by renewable sources, the new
grid regulations now require these
sources to help maintain the stability
of the power grid, as is already
demanded
of conventional generation.
With 4 digital inputs and control
software specially developed by
Ingeteam Power Technology, the
INGECON® SUN ComBox manages,
for the entire plant, all the power
setpoints established by the grid
operators.
314
15
9
62
2.48 kg.
Size and weight (mm)
USB
RS - 485
ETHERNET
GPRS /GSM
INGECON® SUN ComBox
RADIO
Bluetooth
RS - 485
115115
Acce
sori
es
Maximum control over the PV system parameters
INGECON® SUN WeatherBox offers
the possibility of storing meteorological
data for up to 30 days.
Outdoor installationThe INGECON® SUN WeatherBox has
been specially designed for outdoor
installation, with a protection rating of
IP65. Sensors can be connected to
measure a number of parameters such
as module irradiation, wind speed,
module temperature, etc., for optimum
PV plant control.
Easy communicationINGECON® SUN WeatherBox acts as
one more slave in the communication
network, in addition to the PV inverters.
Communication with the INGECON®
SUN WeatherBox can be established
either by RS-485 cable or with the
Bluetooth wireless version.
Meteorological values measurementThe WeatherBox integrates the
functions of measuring and storing
data received from analog inputs with
a greater precision than normal boards.
The following inputs are available:
Dispone de las siguientes entradas:
2 inputs for PT100.
4 inputs 0..10 V o 0..20 mA.
340 g.
Size and weight (mm)
14
6
75
160
INGECON® SUN WeatherBox
Bluetooth
RS - 485
116116
No external sensors: solar
tracking algorithm with an
accuracy of +/-0.0003º.
Status, communication and
general power supply LEDS.
Isolation through optocouplers
at the inputs, quadrature
decoders and pump drive.
Easy integration into the solar
array control and monitoring
system.
Protection devices to guarantee
the safety of the collector,
actuator and equipment itself.
Local control unit designed to control
high precision solar trackers for solar
thermal plants.
Able to control different types of actuators with any type of driveFor controlling and monitoring parabolic
collectors or heliostats. For controlling
single phase and three phase motors,
with or without rotational control, etc.
It also offers the possibility of controlling
single axis and dual axis actuators.
CE Marking CompliantRS-485, USB On-The-Go and
Ethernet communications. Support for
communication protocols such as Modbus
RTU, Modbus TCP, SNTP, HTTP and
proprietary protocols.
High fl exibility for controlling and monitoring solar arrays in solar thermal plants
ADVANTAGES
Size (mm)
55
0
260
460
General input protection:
Thermal magnetic circuit breaker.
LOC voltage surge protection: varistor.
Pump voltage surge protection: varistor.
Over current protection: Fuse.
Communication via Bluetooth,
SPI, I2C and GPRS.
Emergency button.
OPTIONAL ACCESSORIES
PROTECTIONS
117117
Acce
sori
esElectronic Card
Internal Power Supply
Input Voltage 230 Vac
Microcontroller(1)
Architecture RISC
Program FLASH 512 Kbytes
Program SRAM 64 Kbytes
Data FLASH 512 bytes
Real Time Clock (RTC) with BatteryPrecision +/-3.5 ppm
RAM 236 bytes
Valves DriveNumber 8
Type Mosfet
Voltage Vds 60 Vdc
Current Id 12 Amp
Pump or Engine Drive(4)
Number 6
Type Triac
Voltage 800 Vac
Current 25 Amp
Quadrature Decoders (QDEC)(3)(4)
Number 2
Signals A, /A, B, /B, R y /R
Absolute maximum voltage 30 Vdc
Protection Diodes on reverse
Digital Inputs(3)
Number 4
Absolute maximum voltage 30 Vdc
Protection Diodes on reverse
Filtering Trigger Schmitt
Digital OutputsNumber 4
Type Trigger Schmitt
Nominal Switching 5A@125Vac, 2A@250Vac y 5A@30VDC
Analog Inputs(2)
Number 1
Range 0 – 2 mA
ADC Resolution 24 bits
Protection Transil
PT100 Inputs(2)
Number 1
Type 3-wire
Isolation Optocouplers 5V RMS
ADC Resolution Transil
OthersAmbient temperature -10ºC to +65ºC
Protection class IP66
INGECON® SUN LOC
Notes: (1) It stands the format IEEE double precision fl oating point Standard (2) Expandable (3) State indicating Led’s (4) For parabolic collectors the number would be half of this.
118118
The INGECON® SUN String Control is a
device for measuring each PV generator
string current and detecting defective string
currents through INGECON® SUN Manager
software.
String currents can be monitored through
the RS-485 communication cards, GSM/
GPRS, Ethernet or WIFI.
It is easy to mount and is suitable for
outdoor installations.
It is particularly recommended for three
phase inverters.
String current monitoring
String Control 160 String Control 320
Maximum number
of connectable strings16 16
Maximum number
of measurable channels16 16
Maximum current per string 10 Adc 20 Adc
Maximum total current 160 Adc 320 Adc
Number of protection
fuses16 16
Maximum voltage 1,000 Vdc 1,000 Vdc
Inlet connectors PV connectors type 4 PV connectors type 4
Outlet connectors PG M55 (up to 300 mm2) PG M55 (up to 300 mm2)
CommunicationsRS-485, GSM/GPRS, Ethernet,
WIFI, fi bre optics card
RS-485, GSM/GPRS, Ethernet,
WIFI, fi bre optics card
Ambient temperature -20ºC to +65ºC -20ºC to +65ºC
Protection class IP65 IP65
Grounding connector PG M16 (35 mm2) PG M16 (35 mm2)
Size and weight (mm)
230
720
54
0
15 kg.
PROTECTIONS
Individual string fuse protection.
IP65 protection for outdoor installation.
OPTIONAL
SMS alarm functionality for any faulty currents.
DC overvoltage dischargers.
DC switch.
119119
Acce
sori
es
PC software operating in a
Windows® graphical environment
for PV plant management
and monitoring.
Integration of single phase
and three phase inverters and
string control devices in a single
software package.
Communication through different
ways: RS-485, Ethernet and modem.
This software can be downloaded,
free of charge, from the www.ingeteam.com website.
Individual confi guration of
each PV plant inverter.
On-line display of the inverter
internal variables.
Display of all the plant
inverters on a single screen.
Multi-PV plant management
from a single PC.
Historical data capture and
disc storage possibility.
Data log display in a number
of graph or table formats.
Data storage in XML format.
Modem confi guration
for receiving SMS alarm
messages.
Available in English, Spanish,
German, French, Italian,
Czech and Chinese.
Confi guration of the
INGECON® EMS Manager.
SOFTWARE FEATURES
PV plant monitoring software
Full-screen data display, with
customisable wallpaper, for
viewing the most important
plant parameters:
Accumulated energy.
Instantaneous power.
Irradiance*.
Module temperature*.
Ambient temperature*.
Wind speed*.
*If a ComBox with the appropriate sensors has been installed.
ON-SCREEN DATA DISPLAY
List of the variables that are
viewable on-line, stored in the
inverter memory:
Total energy delivered to
the grid.
Total time in operating status.
Total number of grid
connections.
Total number of errors.
Alarm status.
Internal operating status.
Solar panel voltage.
Solar panel current and
power.
Output current and power
to the grid.
Phi cosine.
Phi sine positive/negative.
Grid voltage.
Grid frequency.
Actual date and time.
VARIABLES VIEWABLE ON-LINE
120120
With the INGECON® SUN Monitor software, PV plant data
can be accessed from any PC with an Internet connection
(www.ingeconsunmonitor.com). Its ease of access facilitates
owner, installer or promoter plant control. This software
provides information on the PV plant status and production,
either in list and graphic format or through an e-mailed
production report. This software has been designed to
facilitate owner, installer or promoter plant control, providing
information on the PV plant status in the form of lists and
graphs, whilst there is also the possibility of receiving an
e-mailed production report. Data are recorded and stored
throughout the useful life of the inverter. An iSun Monitor
iPhone application is available at the App Store.
Web portal for PV plant access
121121
Acce
sori
es
PV plant dimensioning
The new INGECON® SUN Planner software offers the
possibility of optimally customising each specifi c project. In
just three fast, simple steps users can correctly dimension a
PV plant, by selecting the type of PV module and INGECON®
SUN inverter that best suits the system, using a database
comprising an extensive range of different modules for each
manufacturer. There is also the option of selecting different
parameters for the plant, for customized dimensioning, to
meet the end customer’s requirements. Registration and
access are free of charge and can be quickly and easily
made through one of the following websites:
www.ingeconsunplanner.com or www.ingeteam.com, to
quickly enjoy all the advantages offered by this software tool
from any web browser, IPod, IPhone, IPad or Android tablet.
Step 1Select the INGECON® SUN
Inverter
Step 2 Select the
PV panel
Step 3 Dimensioning of the PV
plant completed
Plant confi guration in just 3 simple steps
122122
In the case that signals not coming from the inverter
should be implemented in the SCADA, such as the status
of automatics, temperatures, etc., communication remotes
would need to be installed in each of the enclosures.
In the case of INGECON® SUN PowerMax Inverters, this
remote would need to be installed in the AC and auxiliary
services enclosure.
Communication Remotes
Remote operation and SCADA
Remote control enables real time operation and supervision
of the PV installations and is an essential tool for
guaranteeing the highest level of availability.
It is adapted to the requirements of each installation and
can incorporate new features based on modular SCADA
architecture.
It is scalable and fl exible thanks to its OPC based client/
server architecture.
The Remote Controller can integrate the Substation and
any other device that may be remotely controlled. It is
compatible with a multitude of protocols and supports
(ADSL, RDSI, GSM, GPRS, Internet, fi bre optics, radio,
microwaves, and satellite).
Ethernet-TCP/IP (MODBUS,
IEC-608-70-5-104, etc.).
Interbus-S.
Profi bus-DP.
RS-232 (3964, MODBUS,
IEC-60870-5-101, etc.).
RS-485 (3964, MODBUS, etc.).
CAN.
OPC DA & OPC XML Data Client
and Server.
IEC 61850 Client and Server.
IEC 61400-25 Client and Server.
IEC 60870-5- 101/104 – 102
Master-Slave.
DNP 3.0 Master-Slave.
Modbus ASCII-RTU/TCP
Master-Slave.
Other protocols can be done
through a Client/Server
architecture based on OPC.
SOME POSSIBLE COMMUNICATION PROTOCOLS
Acce
sori
es
123123
124124
INTEGRATED AND OPTIONAL ACCESSORIES
Notes: (1) Optional type 2 overvoltage protection (2) For inter-inverter synchronisation, request a quote (3) Equipment prepared, an external control is required (4) At the battery input (5) At the PV inputs (6) At the AC output and the wind power inputs (7) To measure the battery temperature.
1Play HF 1Play TL 1Play TL M
3 Play TL M Lite Lite TL Smart Smart TL Power
ProtectionsGalvanic isolation DC-AC
Reverse Polarity
Input overvoltage (1) (1)
Output overvoltage (1) (1)
Output short circuits and overloads
Insulation failures
Anti-islanding with automatic shutdown
DC fuses
DC load interrupter switch
AC thermal magnetic
Integrated accessoriesMulticontact 4
Potential free contact to indicate an
insulation fault
Push-pull communications connector
Heating resistor
Grounding kit
Sync kit (2) (2) (2)
Night-time power supply
DC current measurement
Firmware updatable via SD card
Firmware updatable
via communication
CommunicationCommunication RS485
Communication Ethernet
Communication GPRS
USB
Analog input
Plant power control(3)
Wireless ISM868
Bluetooth
SoftwareINGECON® SUN Manager for plant
monitoring
INGECON® SUN Monitor for
data viewing
125125
Acce
sori
es
Power TL PowerMax Master-Slave
PowerMax Multi-MPPT
Hybrid AC Link
Hybrid AC Link TL Hybrid Hybrid MS μWind μWind TL ComBox String
Control
(4)
(5) (5)
(6)
(2) (2) (2)
(7) (7) (7)
Integrated Optional Not available
THE BEST TRAINING PLATFORM FOR PROFESSIONALS
128128
INGECON® SUN Training is a training platform
directed at facilitating the work of all those
professionals whose job involves handling the
Ingeteam PV inverters.
At INGECON® SUN Training, we aim to share our
knowledge and experience in the belief that this
is the best way for all of us to progress together.
What’s more, the site is intended to serve as
a meeting point for all those professionals
working in the PV sector, whatever their area
of specialisation.
More info at:
Training for professionals in the PV sector
On-site courses General and specifi c, commercial and technical; free and subsidised. Get more
information on the training available at: www.ingeconsuntraining.com
Tailored courses Tell us your needs and we’ll design a customised training program. We can even
give the course at your facilities.
Live webinars You can also do a course from your own home or offi ce. You simply need a
computer, Internet connection and a microphone headset.
TRAINING COURSES
Visits You’re welcome to visit our facilities. We’d like you to get to know our equipment
right from its origins.
Audiovisual material Our website offers access to videos, presentations and technical documentation
with relevant information on technological developments, technical support etc.
FAQ The FAQ section on our website allows you to check out the answers to the main
doubts raised by our customers. You even have the opportunity to ask us about
any other doubts or question you may have.
Technical articles Keep up-to-date with technical articles on the very latest technological
developments achieved by our team of engineers.
ADDITIONAL SUPPORT
129
Becoming an INGECON® SUN Service
Partner is fast and easy. You simply need
to attend a special course and meet the
minimum requirements.
You will get a certifi cation which licences you
to perform specifi c handling and manipulation
tasks on the INGECON® SUN equipment.
Effi ciencyOur goal is to ensure that our
inverters deliver the highest energy
effi ciency rates possible. We’ll
help you to get the most out of our
products.
Certifi cationOur training courses are certifi ed by
the most reputed solar education
and renewable energy training
organizations worldwide.
FlexibilityWe can adapt to suit your own
particular needs and circumstances,
with customised courses, either
online or face-to-face, depending on
your own specifi c requirements.
ExcellenceOur training personnel are involved
in R&D work, and are therefore
always up-to-date with the very latest
PV technology.
BENEFITS OF BEING A SERVICE PARTNER
Technical support 24 hours a day, 365 days a year.
Access to specifi c technical documentation.
Specifi c training courses.
Immediate availability of spares.
Authorisation to use our logo on your
communications.
Marketing and Merchandising support.
Worldwide authorised installers.
BEYOND THE PRODUCT
132
Quality, R&D&i, Evironment, and Risk Prevention
Ingeteam’s commitment to customers does not end with the product
delivery. The collaboration and service offered to customers initiated
during the product development stage, continues throughout the
product life. Ingeteam is in a position to work alongside customers and
to offer all the necessary support for their expansion within Spain and
abroad, providing technical assistance services anywhere in the world.
OUR COMMITMENT TO OUR CUSTOMERS
In addition to the 5 years Standard
Guarantee, the company offers an
Extended Guarantee for a furher
5 year period, to warranty that the
Ingecon® Sun PV Inverters are
free from any defects in material
and workmanship that would
prevent normal operation in correct
conditions of usage, installation
and maintenance, for up to a total
period of 10 years.
Extended guarantee
Ingeteam offers service in the fi eld:
While the service is in effect it is
possible to contract:
Remote installation monitoring.
Periodic issuance of
production reports.
Computer aided maintenance
management (CAMM).
Spare parts management.
High voltage corrections
in Substations and
Transformer centres.
Operation and management
of energy centres.
Additional services such as
panel cleaning, etc.
Complete PV plant operations and maintenance
Ingeteam Service is committed to
establishing policies that guarantee
customer satisfaction, worker
health and safety, and which are
environmentally friend. Examples of
this effort are:
Continuous improvement of
systems for overall management
of quality, the environment,
prevention of occupational
hazards, and R&D&i under ISO
9001, ISO 14001, SHAS 18001
and UNE 066002 standards.
Implementation of the EFQM
model for corporate excellence.
Making progress with Corporate
Social Responsibility models.
133
Ingeteam offers its customers a
phone based technical service they
can use for technical questions as
well as to report any incidents.
Quick, effective and effi cient
service is offered through a network
of country-wide offi ces.
This network of Service Centres
has been extended to various
countries for our international
customers.
Technical service by phone
Thermograph Analysis of
Components:
Voltage transformers.
PV Generator.
Inverters.
DC Installation and electrical panels.
AC low voltage installation
(Connections and components).
Overhead lines and Substations.
Auxiliary Service Panels.
Irradiation analysis and
effi ciency/effi ciency study:
Photovoltaic Generation
(series/parallel confi guration).
Inverters.
AC low voltage installation.
Physical-chemical analysis
of Insulating Oils.
Predictive maintenance
Quality and assembly audits.
Commissioning.
Component Inspection.
Design and certifi cation of specifi c tooling.
Waste management.
Management system implementation.
Training courses.
Preparation of Technical Work Instructions
and procedures.
Specialized Technical Assistance.
Maintenance engineering.
Development, manufacture and
standardization of tooling.
Audits/Consulting.
Training.
Development of customized monitoring,
supervision and diagnostic tools.
Support, management, and engineering services
134
Ingeteam also offers fi eld
service to its customers
through Ingeteam Service. The
company pertains to the Energy
division, which among other
things, provides operation and
maintenance of installations
using renewable energy to
generate electricity.
Ingeteam Service unites the
experience, knowledge and
leadership position of Ingeteam’s
SERVICE AND MAINTENANCEOF PV SOLAR INSTALLATIONS
design and manufacture of
photovoltaic inverters with the
capabilities of its solid base and
extensive experience operating
and maintaining PV plants.
It currently provides its
operation and maintenance
services to more than 800 PV
solar energy generation and
solar heating plants, for a total
of more than 90 MW.
AvailabilitySpares guaranteeDiagnostics and repair
Online supervisionCommissioningExtended warranty Maintenance
Select your combination
Ingeteam Service
We offer you 7 service
modules to cover
each and every PV
inverter maintenance
requirement. Select those
modules that are best
suited to your system and
combine them to ensure
a reliable operation.
135
Ingeteam is determined to meet the needs and
expectations of its clients. It offers different levels of
after-sales service for pv solar plants, ranging from
customized maintenance to complete installation
maintenance.
Services offered to customers include:
Corrective and preventative maintenance of all
installation components (modules, one or two axis
trackers, internal panels and lines, transformer
centres, safety systems, civil works...).
Plant management and operation.
Continuous and/or remote monitoring.
Preparation of audits and technical reports.
Periodic thermograph analysis of critical points
of the installation.
Periodic panel cleaning.
After-Sales Service
Ingeteam maintains strategic centres
covering the entire country so as to
provide rapid effi cient service for any of
our customers’ solar energy installations.
Our international brand expansion makes
us capable of offering these services any
place in the world.
Ingeteam Service Centers
REFERENCES
138
Ingeteam boasts a long, proven track record
in the industrial and energy sectors, which
stretches back to 1972, clearly demonstrating
the company’s ongoing policy of technological
development. In the nineties, Ingeteam
became more involved in the development of
electrical and control systems specifi c to the
renewable energies sector; this was initially
directed at the wind power and hydroelectric
sectors and then, from 2001 onwards, our
company broadened its scope to encompass
the PV solar energy sector as well.
Since then we have provided our customers
with more than 3 GW of power with INGECON®
SUN photovoltaic inverters. This confi rms
Ingeteam as one of the world leaders in
the PV sector.
At Ingeteam, we have extensive experience in
the design and supply of on-grid inverters for
power ratings ranging from 2.5 to 1,000 kW,
for large-scale PV plants. We also specialize
in the design and manufacture of high-power
off-grid and micro-grid inverters for stand-
alone installations, having supplied this type
of inverters principally to the regions of Pacifi c
Asia and Africa.
One of our key benchmark projects is the PV
plant at San Bellino (Italy); this plant is one of
the largest of its kind in the world, having an
installed rated power of 70 MWp. The 60 MWp
Nobesol solar plant situated in Olmedilla de
Alarcón (Spain) is another important project
in which Ingeteam has participated, supplying
more than 450 INGECON® SUN 100 inverters.
Ingeteam has also supplied on-grid PV
inverters to some of the most relevant
commercial installations, like the world’s
largest PV greenhouse, a 20 MWp installation
in Sardinia (Italy).
1
1. ISOLUX CORSÁN
PV plant at San Bellino (Italia)70 MWp (60 INGECON® SUN PowerMax Indoor)
139
3 54
2
5. NOBESOL
PV array at Olmedilla de Alarcón (Spain)60 MWp (453 INGECON® SUN 100)
ACCIONA SOLAR
2. IPV installation on facade (Spain) 60 kW (4 INGECON® SUN 10, 1 INGECON® SUN 20)
3. PV array at Amareleja (Portugal)46 MWp (70 INGECON® SUN 500TL)
4. CANTIERI ITALIANI
Concrete housing at Sardegna (Italy)
9 MW (4 INGECON® SUN 500 M275,
2 INGECON® SUN 630 M360)
140
8
7
6
7. GENERAL ELECTRIC AND MOSER BAER CLEAN ENERGY
Installation in Sardegna (Italy) 20 MWp (14 INGECON® SUN PowerStation
with 23 INGECON® SUN 630 M360 Indoor, 4 INGECON® SUN 500 M275
Indoor, 1 INGECON® SUN 315 M275 Indoor)
6. M+H POWER
Stand alone PV array at Innawonga Bellary (Australia) 20 kWp (INGECON® HYBRID)
8. RISING SUN SOLAR
PV array at Hawaii (USA) 250 kW (2 INGECON® SUN 100
U, 2 INGECON® SUN 25 U)
REFERENCES
141
12
11
109
10. GMN
Stand alone PV away at Nembrala (Indonesia) 21 kWp (INGECON® HYBRID)
12. ISOLUX CORSÁN
Installation in the county of Cornwall (England) 15 MWp (24 INGECON® SUN
500 M275 Indoor)
11. GRUPOTEC SOLAR
PV array on an industrial roof at Molina de Segura (Spain) 990 kWp (9 INGECON® SUN 100)
9. SINERGIA SISTEMI
PV on-roof installation at the Lamborghini factory in Sant’Agata Bolognese (Italy)
1.2 MWp (20 INGECON® SUN 6TL, 2 INGECON® SUN
375 M220 Indoor, 1 INGECON® SUN 100)
142
13. MPX
PV array at Tauá (Brasil)1 MWp (9 INGECON® SUN 100TL)
16. GES s.p.a
PV plant at Villasor (CA) (Italy)20 MW (23 INGECON® SUN 630 M360
Indoor, 4 INGECON® SUN 500 M275 Indoor)
15
14
13
14. EMCO LIMITED
PV array at Fatepur (Gujarat, India) 5 MW (7 INGECON® SUN 600 M345 Indoor)
15. SOLARTIA
PV array at Viana (Spain)8.7 MWp (223 INGECON® SUN 5, 106
INGECON® SUN 25, 40 INGECON® SUN 100)
REFERENCES
143
16
19
18
17
17. EOSOL
PV plant at Villeneuve de Marsan (France)8 MWp (14 INGECON® SUN 500 M275 Indoor)
19. CEGELEC
PV array at Midi-Pyrénées (France)8 MWp (13 INGECON® SUN 500 M275 Indoor)
18. ASSYCE
PV array at Mae Chan (Thailand)8 MW (16 INGECON® SUN 500 M275 Indoor)
Ingeteam Power Technology, S.A.Avda. Ciudad de la Innovación, 13
31621 SARRIGUREN (Navarra) - Spain
Tel.: +34 948 288 000 / Fax: +34 948 288 001
e-mail: [email protected]
Ingeteam S.r.l.Via Emilia Ponente, 232
48014 CASTEL BOLOGNESE (RA) - Italy
Tel.: +39 0546 651 490 / Fax: +39 054 665 5391
e-mail: [email protected]
Ingeteam GmbHHerzog-Heinrich-Str. 10
80336 MUNICH - Germany
Tel.: +49 89 99 65 38 0 / Fax: +49 89 99 65 38 99
e-mail: [email protected]
Ingeteam SASLa Naurouze C - 140 rue Carmin
31670 Labège - France
Tel: +33 (0)5 61 25 00 00 / Fax: +33 (0)5 61 25 00 11
e-mail: [email protected]
Ingeteam INC.5201 Great American Parkway, Suite 320
SANTA CLARA, CA 95054 - USA
Tel.: +1 (415) 450 1869 / +1 (408) 524 2929 / Fax: +1 (408) 824 1327
e-mail: [email protected]
Ingeteam INC.3550 W. Canal St.
MILWAUKEE, WI 53208 - USA
Tel.: +1 (414) 934 4100 / +1 (855) 821 7190 / Fax: +1 (414) 342 0736
e-mail: [email protected]
Ingeteam, a.s.Technologická 371/1
70800 OSTRAVA - PUSTKOVEC
Czech Republic
Tel.: +420 59 732 6800 / Fax: +420 59 732 6899
e-mail: [email protected]
Ingeteam Shanghai, Co. Ltd.Shanghai Trade Square, 1105
188 Si Ping Road
200086 SHANGHAI - P.R. China
Tel.. +86 21 65 07 76 36 / Fax: +86 21 65 07 76 38
e-mail: [email protected]
Ingeteam, S.A. de C.V.Ave. Revolución, nº 643, Local 9
Colonia Jardín Español - MONTERREY
64820 - NUEVO LEÓN - México
Tel.: +52 81 8311 4858 / Fax: +52 81 8311 4859
e-mail: [email protected]
Ingeteam Ltda.Rua Luiz Carlos Brunello, 286
Chácara Sao Bento
13278-074 VALINHOS SP - Brazil
Tel.: +55 19 3037 3773 / Fax: +55 19 3037 3774
e-mail: [email protected]
Ingeteam Pty Ltd.Unit 2 Alphen Square South
16th Road, Randjiespark, Midrand 1682 - South Africa
Tel.: +2711 314 3190 / Fax: +2711 314 2420
e-mail: [email protected]
Ingeteam SpABandera , 883 Piso 211
8340743 Santiago de Chile - Chile
Tel.: +56 2 738 01 44
e-mail: [email protected]
Ingeteam Pvt. Ltd.2nd Floor, 431
Udyog Vihar, Phase III
122016 Gurgaon (Haryana) - India
Tel.: +91 124 435 4238 / Fax: +91 124 435 4001
e-mail: [email protected]
Ingeteam Sp. z o.o.Ul. Koszykowa 60/62 m 39
00-673 Warszawa - Poland
Tel.: +48 22 821 9930 / Fax: +48 22 821 9931
e-mail: [email protected]
Ingeteam Power Technology, S.A.
www.ingeteam.com PC00ISA01 _L INFORMATION SUBJECT TO MODIFICATION