Software modules to fulfil the requirements for evaluation ... · Industrial Town, Rajajinagar...

2
©DURAG GROUP 01/2008 · Subject to change without notice DURAG GmbH Kollaustraße 105 22453 Hamburg · Germany Tel.+49 (0)40 55 42 18-0 Fax+49 (0)40 58 41 54 E-Mail: [email protected] DVN - DURAG Vertrieb/Service Nord Kollaustraße 105 22453 Hamburg · Germany Tel.+49 (0)40 55 42 18-0 Fax+49 (0)40 58 41 54 E-Mail: [email protected] DVO - DURAG Vertrieb/Service Ost Meißner Ring 4 09599 Freiberg · Germany Tel. +49 (0)3731 30 04-0 Fax+49 (0)3731 30 04-22 E-Mail: [email protected] DVS - DURAG Vertrieb/Service Süd Weidenweg 16 73087 Boll · Germany Tel. +49 (0)7164 912 25-0 Fax+49 (0)7164 912 25-50 E-Mail: [email protected] DVW- DURAG Vertrieb/Service West An der Pönt 53a 40885 Ratingen · Germany Tel. +49 (0)2102 74 00-0 Fax+49 (0)2102 74 00 28 E-Mail: [email protected] www.durag.de DURAG France S.a.r.l. Parc GIP Charles de Gaulle 49, rue Léonard de Vinci BP 70166 95691 GOUSSAINVILLE CEDEX · France Tel.+33 (0)1 301 811 80 Fax+33 (0)1 393 383 60 E-Mail: [email protected] DURAG, Inc., USA 1355 Mendota Heights Road · Suite 200, Mendota Heights · MN 55120 · USA Tel. +1 651 451-1710 Fax+1 651 457-7684 E-Mail: [email protected] DURAG India Instrumentation Ltd #143/16, Ground Floor, 4th Main Road Industrial Town, Rajajinagar Benga- looru 560 044 Tel.+91 (0)80 23 14 56 26 Fax+91 (0)80 23 14 56 26 Ext. 30 E- Mail: [email protected] DURAG China Room 708 · TSENG CHOW Commercial Mansion 1590 Yan An West Road Shanghai 200052 · P. R. China Tel.+86 (0)21 6280 8277 Fax+86 (0)21 6280 9236 E-Mail: [email protected] Hegwein GmbH Am Boschwerk 7 70469 Stuttgart · Germany Tel.+49 (0)711 135 788-0 Fax+49 (0)711 135 788-5 E-Mail: [email protected] Smitsvonk Holland B.V. P.O. Box 180 · 2700 AD Zoetermeer Loodstraat 57 · 2718 RV Zoetermeer The Netherlands Tel.+31 (0)79 361 35 33 Fax+31 (0)79 361 13 78 E-mail: [email protected] VEREWA Umwelt- und Prozessmesstechnik GmbH Kollaustraße 105 22453 Hamburg · Germany Tel.+49 (0)40 55 42 18-0 Fax+49 (0)40 58 41 54 E-Mail: [email protected] DURAG process & systems technology gmbh Kollaustraße 105 22453 Hamburg · Germany Tel.+49 (0)40 55 42 18-0 Fax+49 (0)40 58 41 54 E-Mail: [email protected] Certified by TÜV Süd Germany acc. to UNFCCC approved methodologies Real-time data collecting and evaluation system with long term data storage Calculation and statistics acc. to methodology requirements and considering EN 14181 Backup data base with correction function for substitution of failed or implausible values Password protected provision of measured and calculated values on the Internet Software modules to fulfil the requirements for evaluation of CDM and JI projects

Transcript of Software modules to fulfil the requirements for evaluation ... · Industrial Town, Rajajinagar...

Page 1: Software modules to fulfil the requirements for evaluation ... · Industrial Town, Rajajinagar Benga-looru 560 044 Tel.+91 (0)80 23 14 56 26 ... evaluation of CDM and JI projects

©DURAG GROUP 01/2008 · Subject to change without notice

DURAG GmbHKollaustraße 10522453 Hamburg · GermanyTel.+49 (0)40 55 42 18-0Fax+49 (0)40 58 41 54E-Mail: [email protected]

DVN - DURAG Vertrieb/Service NordKollaustraße 10522453 Hamburg · GermanyTel.+49 (0)40 55 42 18-0Fax+49 (0)40 58 41 54E-Mail: [email protected]

DVO - DURAG Vertrieb/Service OstMeißner Ring 409599 Freiberg · GermanyTel.+49 (0)3731 30 04-0Fax+49 (0)3731 30 04-22E-Mail: [email protected]

DVS - DURAG Vertrieb/Service SüdWeidenweg 1673087 Boll · GermanyTel.+49 (0)7164 912 25-0Fax+49 (0)7164 912 25-50 E-Mail: [email protected]

DVW- DURAG Vertrieb/Service WestAn der Pönt 53a40885 Ratingen · GermanyTel.+49 (0)2102 74 00-0Fax+49 (0)2102 74 00 28E-Mail: [email protected]

www.durag.de

DURAG France S.a.r.l.Parc GIP Charles de Gaulle49, rue Léonard de VinciBP 7016695691 GOUSSAINVILLE CEDEX · FranceTel.+33 (0)1 301 811 80Fax+33 (0)1 393 383 60E-Mail: [email protected]

DURAG, Inc., USA1355 Mendota Heights Road · Suite 200,Mendota Heights · MN 55120 · USA Tel.+1 651 451-1710Fax+1 651 457-7684E-Mail: [email protected]

DURAG India Instrumentation Ltd#143/16, Ground Floor, 4th Main RoadIndustrial Town, Rajajinagar Benga-looru 560 044Tel.+91 (0)80 23 14 56 26 Fax+91 (0)80 23 14 56 26 Ext. 30 E-Mail: [email protected]

DURAG ChinaRoom 708 · TSENG CHOW Commercial Mansion1590 Yan An West RoadShanghai 200052 · P. R. ChinaTel.+86 (0)21 6280 8277Fax+86 (0)21 6280 9236E-Mail: [email protected]

Hegwein GmbHAm Boschwerk 770469 Stuttgart · GermanyTel.+49 (0)711 135 788-0Fax+49 (0)711 135 788-5E-Mail: [email protected]

Smitsvonk Holland B.V.P.O. Box 180 · 2700 AD ZoetermeerLoodstraat 57 · 2718 RV ZoetermeerThe NetherlandsTel.+31 (0)79 361 35 33Fax+31 (0)79 361 13 78E-mail: [email protected]

VEREWA Umwelt- und ProzessmesstechnikGmbHKollaustraße 10522453 Hamburg · GermanyTel.+49 (0)40 55 42 18-0Fax+49 (0)40 58 41 54E-Mail: [email protected]

DURAG process & systems technology gmbhKollaustraße 10522453 Hamburg · GermanyTel.+49 (0)40 55 42 18-0Fax+49 (0)40 58 41 54E-Mail: [email protected]

● Certified by TÜV Süd Germanyacc. to UNFCCC approvedmethodologies

● Real-time data collecting andevaluation system with long termdata storage

● Calculation and statistics acc. to methodology requirements and consideringEN 14181

● Backup data base with correction function for substitution offailed or implausible values● Password protected provision of measured and

calculated values on the Internet

Software modules to fulfil the requirements for evaluation of CDM and JI projects

Page 2: Software modules to fulfil the requirements for evaluation ... · Industrial Town, Rajajinagar Benga-looru 560 044 Tel.+91 (0)80 23 14 56 26 ... evaluation of CDM and JI projects

GreenhouseGas TradingThe Kyoto Protocol contains amarket-based approach tocombat climate change in theform of the flexible mecha-nism emissions trading andgeneration of tradable emis-sion reduction creditsthrough projects.While many developed countries in theKyoto Protocol accepted a cap of theirtotal greenhouse gas (GHG) emissions,developing countries negotiated thattheir emissions will still be allowed togrow, as more economic growth isneeded. In order to facilitate technol-ogy transfer to help developing coun-tries in their sustainable developmentand at the same time assist the invest-ing (developed) countries with a cap tofulfil their commitment projects result-ing in emission reductions might beundertaken in developing countries.Such emission reductions are verifiedby a third party and can be used in acountry with a cap on emissions tocomply with their emission target. Inorder to generate emission reductionsa project has to prove that its imple-mentation leads to emissions lowerthan what would have happened in theabsence of the project. Examples of such projects are catalyticN2O destruction in the tail gas of nitricacid or caprolactam production plantsor methane capture in landfills. The generation of those emission re-ductions is under very strict supervi-sion of the UN as every emissionreduction generated in a develop-ing country that qualifies under themarket approach can be used to offsetemissions in a developed country.Hence the use of emission reductionsgenerated in third countries by a coun-try with a cap increases the totalamount of emissions possible in thatcountry. As a consequence only proj-ects that have a sound environmentalbasis, generating clearly additionalemission reductions qualify for thismarket mechanism.

D-FL 100: Measuring system to measureflow rate in dry emissions with a probe usingthe differential pressure principle

● Measurement of emission speed ● Calculation of volume flow at standard con-

ditions with the evaluation unit D-FL 100-10(optional)

● Adjustable parameters ● Automatic back purging device (optional) ● Versions with or without counter-support

and for point measurement

D-FL 200: Measuring system for ultra-sonicmeasuring of flow and volume flow, espe-cially for wet and aggressive smoke emis-sions (e.g. waste incineration)

● Measurement possible below dew point andin high dust concentrations

● Continuous measurement of normalvolume flow and gas speed

● Automatic zero point and refer-ence point control

● Direct connection fortemperature andpressure cor-rection

● Parameterinput via keyboard or PC

● D-EMS CDM Internet Module to inform person in charge about thedetails of current and historical data (measured and evaluated val-ues) as well as the results of all realised campaigns

● Access only with valid username and password

Gas volume flow meters to continuously monitor the gas volume flow, temperature and pressure in the stacks

D-EMS 2000 CDMFulfils the minimum requirements for electronic evaluationunits acc. to UNFCCC approved methodologies● Registration, mean average determination, validation and evaluation of all re-

quired data● Validity proof of calibration curves ● Provision of required protocols and print-outs● Permanent quality assurance of the analysers acc. to EN 14181 during plant

operation● Assurance of reliable and correct operation incl. complete documentation of

the monitoring equipment.

Required measurement equipment to fulfil approved UNFCCCmethodologies