Software - Ahlborn · Software 05.07 06/2018 • We reserve the right to make technical changes....

12
05.06 Software 06/2018 We reserve the right to make technical changes. AMR WinControl the software for all ALMEMO ® measuring instruments Software Versions: Order no. Light: For 20 measuring points and one instrument SW5600WC1 Standart: For any number of measuring points and instruments SW5600WC2 Profi: For any number of measuring points and instruments, all options included (except Data server, Web server and additional modules) SW5600WC3 Server: For any number of measuring points and devices, all options included (except add-on modules), with an integrated data server (simultaneous access by several RMT WinControl clients). SW5600WC4 Update: of the latest software version for older versions SW5600WCU3 of the latest software version for newer versions SW5600WCU4 Software Description: • Software for acquiring, displaying and processing measured data of the ALMEMO ® device series (V5, V6, and V7.) • Convenient programming and operation of the devices. • Graphical display, mathematical processing and printing (measurement report) of current and saved data. • Appropriate for long term measurements (GMP) or for control and monitoring tasks. Can be easily adapted to every project. • Fast familiarization and safe operation thanks to Windows interface and the context-sensitive help. • Further information and the current demo version are available under www.akrobit.de. Options: Order no. Network capability (for addressing several ALMEMO ® devices) SW5600WCO1 Automatic generation of measured data files (daily files / weekly files) SW5600WCO2 Alarm function (alarm record, output to ALMEMO ® relays, starting other applications) SW5600WCO5 Data server see 05.15 SW5600WCO8 Web server see 05.16 SW5600WCO9 Extended evaluation functions see page 05.11 SW5600WCO10 Fast scanning of measured values for V7 devices (up to 1000 mops online) SW5600WCO11 new: PIMEX Player: combined measured value display and video display(see 05.17) SW5600WCO12 Additional modules: Order no. Thermal comfort and air-conditioning calculations (as per DIN 1946, EN ISO 7730); (see 05.12) SW 5600 WCZM1 Password protection (see 05.13) SW 5600 WCZM2 Test bench manager (prerequisite : WC3 / WC4 or WC1 / WC2 + WCO2) (see 05.14) SW 5600 WCZM3 Thermal transmittance (U) wizard (see 05.12 and chapter Building physics) SW 5600 WCZM4 Thermal quantity wizard (see 05.13) SW 5600 WCZM5 OPC export (see 05.14) SW 5600 WCZM6 Additional protocol (selectable, requires WC3 / WC4) (see system integration, page 05.15) SW 5600WCZM7 Security package (requires WC3 / WC4) (see 05.16) including watchdog card SW 5600 WCZM8 The memory is read out automatically (see 05.10 connecting options) SW 5600 WCZM9 Automated printing (line diagrams, tables) (needed: WC3/WC4 oder WC1/WC2 + WCO2) SW5600WCZM10 ODBC-Support (export to SQL-databases) (see 05.14) SW5600WCZM11 Assistant for calibrating measuring sensors (needed: WC3/WC4) (see 05.12) SW5600WCZM12 Assistant for calibrating climate cabinets (needed: WC3/WC4) (see 05.13) SW5600WCZM13 new: PIMEX Recorder: combined measured value recording and video recording (requirement: WC3/WC4) SW5600WCZM14 Complete packages (see 05.16 - 05.17): Order no. Long-term / continuous monitoring SW 5600 WCV new: CAN Trace: combined measured data recording and CAN data recording as well as evaluation functions SW5600WCCAN Hardware copy protection (see 05.17): Order no. USB dongle SW 5600 HL USB network dongle SW5600NHL

Transcript of Software - Ahlborn · Software 05.07 06/2018 • We reserve the right to make technical changes....

Page 1: Software - Ahlborn · Software 05.07 06/2018 • We reserve the right to make technical changes. Function overviewy WC1 WC2 WC3 WC4 WCV Measured values - scanning Number of measuring

05.06

Software06/2018 • W

e reserve the right to make technical changes.

AMR WinControl the software for all ALMEMO® measuring instruments

Software Versions: Order no.Light: For20measuringpointsandoneinstrument SW5600WC1Standart:Foranynumberofmeasuringpointsandinstruments SW5600WC2Profi: Foranynumberofmeasuringpointsandinstruments,alloptionsincluded (exceptDataserver,Webserverandadditionalmodules) SW5600WC3Server: Foranynumberofmeasuringpointsanddevices,alloptionsincluded(exceptadd-onmodules), withanintegrateddataserver(simultaneousaccessbyseveralRMTWinControlclients). SW5600WC4Update: ofthelatestsoftwareversionforolderversions SW5600WCU3 ofthelatestsoftwareversionfornewerversions SW5600WCU4

Software Description:•Software for acquiring, displaying and processing measureddataoftheALMEMO®deviceseries(V5,V6,andV7.)

•Convenientprogrammingandoperationofthedevices.•Graphical display, mathematical processing and printing(measurementreport)ofcurrentandsaveddata.

•Appropriateforlongtermmeasurements(GMP)orforcontrolandmonitoringtasks.Canbeeasilyadaptedtoeveryproject.

•Fast familiarization and safe operation thanks to Windowsinterfaceandthecontext-sensitivehelp.

•Furtherinformationandthecurrentdemoversionareavailableunderwww.akrobit.de.

Options: Order no. Networkcapability(foraddressingseveralALMEMO®devices) SW5600WCO1Automaticgenerationofmeasureddatafiles(dailyfiles/weeklyfiles) SW5600WCO2Alarmfunction(alarmrecord,outputtoALMEMO®relays,startingotherapplications) SW5600WCO5Dataserversee05.15 SW5600WCO8Webserversee05.16 SW5600WCO9Extendedevaluationfunctionsseepage05.11 SW5600WCO10FastscanningofmeasuredvaluesforV7devices(upto1000mopsonline) SW5600WCO11new:PIMEXPlayer:combinedmeasuredvaluedisplayandvideodisplay(see05.17) SW5600WCO12Additional modules: Order no. Thermalcomfortandair-conditioningcalculations(asperDIN1946,ENISO7730);(see05.12) SW5600WCZM1Passwordprotection(see05.13) SW5600WCZM2Testbenchmanager(prerequisite:WC3/WC4orWC1/WC2+WCO2)(see05.14) SW5600WCZM3Thermaltransmittance(U)wizard(see05.12andchapterBuildingphysics) SW5600WCZM4Thermalquantitywizard(see05.13) SW5600WCZM5OPCexport(see05.14) SW5600WCZM6Additionalprotocol(selectable,requiresWC3/WC4)(seesystemintegration,page05.15) SW5600WCZM7Securitypackage(requiresWC3/WC4)(see05.16)includingwatchdogcard SW5600WCZM8Thememoryisreadoutautomatically(see05.10connectingoptions) SW5600WCZM9Automatedprinting(linediagrams,tables)(needed:WC3/WC4oderWC1/WC2+WCO2) SW5600WCZM10ODBC-Support(exporttoSQL-databases)(see05.14) SW5600WCZM11Assistantforcalibratingmeasuringsensors(needed:WC3/WC4)(see05.12) SW5600WCZM12Assistantforcalibratingclimatecabinets(needed:WC3/WC4)(see05.13) SW5600WCZM13new:PIMEXRecorder:combinedmeasuredvaluerecordingandvideorecording(requirement:WC3/WC4) SW5600WCZM14Complete packages(see05.16-05.17): Order no.Long-term/continuousmonitoring SW5600WCVnew:CANTrace:combinedmeasureddatarecordingandCANdatarecordingaswellasevaluationfunctions SW5600WCCANHardware copy protection(see05.17): Order no.USBdongle SW5600HLUSBnetworkdongle SW5600NHL

Page 2: Software - Ahlborn · Software 05.07 06/2018 • We reserve the right to make technical changes. Function overviewy WC1 WC2 WC3 WC4 WCV Measured values - scanning Number of measuring

Software

05.07

06/2

018

• W

e res

erve

the r

ight to

mak

e tec

hnica

l cha

nges

.

Function overviewy WC1 WC2 WC3 WC4 WCVMeasured values - scanning Numberofmeasuringpointssupported 20 unlimited. unlimited. unlimited. unlimited.

Numberofconnectionssupported 1 unlimited. unlimited. unlimited. unlimited.

SupportforALMEMO®network FastscanningofmeasuredvaluesforV7devices(upto1000mopsonline) Connection typesSerial(COM),TCP/IP Modem,GSM,andwirelessmodemsupport Schedule-controlledconnectionsetup Measured values - displayDisplayofmeasuredvalues(numeric,barchart,windrose,roundgauges) Linegraph(YT),XYgraph Save/loadpresentationcharacteristicsasformattype Table,overview Zoomfunctions Projecticons Worksurfaces Measured values - saving Savingtoharddisk-manual Savingtoharddisk-automatic Automaticgenerationofdaily,weekly,monthlyfiles Automaticsavingonanevent-controlledbasis Automaticallysavedfiles-sentbye-mail Automatedprintingoffilesaslinediagramortable Automaticallysavedfiles-backedupautomatically Fail-safe(onlydeviceswithfailsafemodeandinternalmemory) Measured values - analysisTwomeasuringcursorswithstatisticsfunction Displayinglocalmaximumandminimumvaluesinalinegraph Loadingcomparativecharacteristicsinalinegraph Arithmetic channelsGlobalarithmeticchannels Localarithmeticchannelsforfilesalreadysaved Calculationsbasedonexternaltablevalues FormeleditormitSyntax-Hervorhebung FormelvorlagenfürvieleAnwendungsfälle Measured values - processing Linking/splittingoffiles Groupingmeasuredvaluefilesinaparticularfolder(wildcardsearch) Groupingmeasuredvaluefilesoveraparticularperiodoftime Exporting measured valuesClipboard Fileformats(MS-ExcelXLS/XLSX,TXT/CSV,FAMOS,QS-STAT,DIAdem,binary) Dynamicdataexchange(DDE,OLE) OnlinedatatransmissiontoMS-Excel Measured values - importASCII(list,columns,tableformats) ALMEMO®Viewfiles Programming of measuring points and devices Programmingthecharacteristicsofmeasuringpointsanddevices Automatedscalingofthird-partysensors Measuringpointsprogramming-savetofile/loadfromfile

Page 3: Software - Ahlborn · Software 05.07 06/2018 • We reserve the right to make technical changes. Function overviewy WC1 WC2 WC3 WC4 WCV Measured values - scanning Number of measuring

05.08

Software06/2018 • W

e reserve the right to make technical changes.

Editingtheprogrammedfile(similartoExceltables) Data reductionAveragingfunction(ONLINEandOFFLINE) Smoothing(overtime/overnumberofvalues,ONLINEandOFFLINE) Data logger functions Programmingthedatalogger(includingaveragingfunctions) Readoutfromdevicememory(all/selectivemeasuredvalues) Displayofmemoryoccupancystatus Alarm functions Alarmvaluedisplayinmeasuringpointslistandinallmeasuredvaluedisplays Alarmreportwithconfirmationandcommentstext Eventslist(audittrail) Startaprogramintheeventofaparticularfault Sende-mail/SMSintheeventofanalarm SwitchALMEMO®outputrelays(specifictomeasuringpoint). Incaseofanalarm,tonesandsoundrecordingareplayedback(viaasoundcard) Controlcommandsdependentonmeasuredvalues(KwikScript) Advancewarningalarm Alarmlogprintout Schedulesforalarmprocessing Automaticcheckingofsystemconfiguration Password protectionProtectionagainstunauthorizedaccess Protectionagainstoperatorerrorbyassigningindividualaccessrights Traceabilityofactivitiesbymeansofaneventslist Alarmconfirmationwithuseridentification Control and regulationTwo-pointcontrollerwithALMEMO®outputrelay?*?s ProportionalcontrollerwithALMEMO®analogoutputmodules PIDcontrollerwithALMEMO®analogoutputmodulesandarithmeticchannels Automation by means of user-defined operating controlsKeysandbuttonsinprojecticonsandasatoolbar Settingconstants Starting/stoppingameasuringoperation Switchingrelays Settinganalogoutputvalues Configuration management Save/loadinterfaceconfiguration PrintoutDiagrams,meas.valuetables,meas.pointlist,fileoverviewincludingcomments Network server functions DisplayingmeasuredvaluesanddiagramsonIntranetorInternet EmbeddingdiagramsandprojecticonsonyourownInternetpages Accessingtheintegratedwebserverviaanybrowser AccessingmeasureddataandhistorydataviaTCP/IP(opentextprotocol) ForwardingmeasureddatatoRMTWinControl Availabilityofalreadyacquiredmeasureddataevenafterprogramrestart Alarmconfirmationviawebserver

AfterinitialinstallationAMRWinControlwillrunindemomode-comprisingthefullfunctionalityoftheprofessionalversion(WC3)-foratrialperiodof30days,afterwhichtimeitwillhavetoberegistered.Allthefunctionsincorporatedintheprofessionalversioncanbetriedwithoutre-strictionandwithoutengagement.Iffurtherfunctions(additionalmodules)areneededfortestpurposes,thesecanalsobeenabledonatemporarybasis.Userscanthustrythesoftwareforthedurationofthetrialperiodwiththefullrangeoffunctionsnormallyneededandthenplaceanorderafterthesystemhasbeenrunningtotheircompletesatisfaction.Registrationdoesnotneedreinstallation.

Page 4: Software - Ahlborn · Software 05.07 06/2018 • We reserve the right to make technical changes. Function overviewy WC1 WC2 WC3 WC4 WCV Measured values - scanning Number of measuring

Software

05.09

06/2

018

• W

e res

erve

the r

ight to

mak

e tec

hnica

l cha

nges

.

•The main window is the platform for all operations withAMRWinControl.Allactionsrunwithinthiswindowandcanbeminimisedtoasymbol,withinthewindowortogetherwiththewindow,andruninthebackground.

•Themeasuringdatacanbepresentedasfollows:Numericpresentationofmeasuredvalues,bardiagram,windrose,roundinstruments,linediagram,XYdiagram,table,fileoverview.

•Windowscanbedistributedovervariousworksurfacesbetweenwhichitispossibletoswitchbymeansoftabs.

•Theprogramcanbeoperatedbymeansofmenucommands.Onlythosecommands,whichcanbeexecutedinthecorrespondingsituation,willbeavailable.Forafasteroperationcontext-sensitivemenus,keyboardcommandsandsymbolsinthetoolbarareavailable.

•Comprehensive help information is available via the function descriptions in thestatusline,notesinthetoolbarandacontext-sensitivehelpsystem.

Main Window/General View

•Assoonastheprogramisstartedandtheserialinterfaceisassigned,allsensorsthatareprogrammedandconnected to themeasuring instrument(s)willbe recognizedautomaticallyanddisplayedinthelistofmeasuringpoints.

•Apart from sensor specific data regarding the measuring range, comment, limitvalues, correctionvalues the list also contains symbols for limit value exceeding,sensorbreakageandonlinestorage.

•Device-specificinformation,e.g.device type,memoryoccupancy,andsettingsforoperatingthedataloggerarealsodisplayed.

•Measuringinstrumentscanbeconnectedviavariousinterfaces(COM,TCP,modem)simultaneously; mixed-mode operation over various connections is possible.Informationregardingthecurrentstatusofconnectionsisdisplayedhere.

List of Measuring Points, devices and connections

•Thelinegraphdisplaysthetemporalevolutionofthevaluesofongoingmeasurementoperationsorofsaveddata.

•Customerspecificsettingsforthelinegraphcanbesavedasatemplateandcanbeappliedintwoclickstootherfiles.Alternativelyitisalsopossibletocreateanewdiagramwiththesavedtemplate.

•Thezoomfunctionandthepossibilitytoshifttheaxeswiththemouseenableaneasynavigationthroughthedata.

•Twomeasuringcursorshelptoanalyzetheacquireddata.•The integrated statistics function calculates differences, minimum, maximum,averagevalueandstandarddeviationoftherangedefinedbythecursorsanddisplaysthedatainatable.

•Thediagramandthetablecanbeprinted,orcanbecopiedtotheclipboard..

Line graph, measuring cursors and statistics function

•Acquiredmeasured values can be further processed and displayed via arithmeticchannelsduringaswellasafterthemeasuringoperation.

•The arithmetic channel feature of the program offers the possibility to calculatefurthervariablesfromthemeasureddata,toderivestatuses,andtoverifyconditions.

•Thenewformulaeditorfacilitatesthecolorhighlightingandcheckingofthesyntax(syntaxhighlighting)aswellastheconvenientselectionandintegrationofmeasuringpoints.

•Forcommoncalculationsandtaskstherearenowformulatemplatesavailablethatcanbedirectlyenteredandcombinedintheformulaeditor.

•Dependingonthedefinition,anarithmeticchannelisavailableeithergloballyintheentireprogramasavirtualmeasuringpointorjust locallyinonedatarecord(linediagramsorXYdiagrams,table).

• It is alsopossible to extendalready saveddata recordsbyanydesirednumberofarithmeticchannels.

•Arithmeticchannelscanbesavedtogetherinonefileandcanbeloadedagainatanytime.Thisenablesaconvenientevaluationofsaveddatawithjustafewclicks.

Arithmetic channels / new formula editor

Page 5: Software - Ahlborn · Software 05.07 06/2018 • We reserve the right to make technical changes. Function overviewy WC1 WC2 WC3 WC4 WCV Measured values - scanning Number of measuring

05.10

Software06/2018 • W

e reserve the right to make technical changes.

•Thismodulegreatlyfacilitatesthetaskofreadingoutfromthedevicememoryofanautonomousdatalogger.

•Saving data to the data logger is interrupted, itsmemory is read out, and, if thisissuccessful,thememorycontentisdeleted.Thetime-of-dayissynchronizedandsavingdatatothedataloggerisresumed.

•Readingoutfrommemorycanbecompletelyautomatedintheformofschedules.•Allstepsandpossibleerrorsaredocumentedintheeventslist..

The memory is read out automatically

•Analarmcanbetriggeredbyacomponentfailureoralimitvalueinfringement.•Alarmprocessingcanbeactivatedindividuallyforeachmeasuringpoint.•Alarmsarereportedvisuallyand/oracoustically.•The cause and the duration of events responsible for triggering the alarm aredocumentedinaneventslist.

•Alarmreportscanbeconfirmedeitherindividuallyoralltogether.• Ifthecauseofanalarmpersistsuncorrectedanalarmreminderisissuedtoensurethatthealarmisnotforgottenafterithasbeenconfirmed.

•A line graphwith settable history can be generated for the variable triggering analarm.

• Intheeventofanalarmbeingtriggerede-mailscanbesent,ALMEMO®outputrelayscanbeswitched,andprogramsorscriptscanbeexecuted.

•Alarmreportscanbeforwardedviathenetwork.• In the event of a limit value being infringed program control commands can beexecuted(KwikScript).

Monitoring Functions

•SettingsnecessaryforoperatingthedataloggercanalsobeprogrammedviatheAMRWinControlsoftware.

•The memory can be read out and deleted. The time of the data logger can besynchronizedwiththeoneofthesystem.

• Important information regarding thememory and the set cycles of the device aredisplayedintheoverviewofthemeasuringdevice.

•The readout of the memory devices can occur individually or combined for alldataloggersinthemeasuringnetwork,whereatapreviewofalreadyreadvaluesisdisplayedinalinediagram.

•Optionally it can be determined that only a selection of the saved values (not allmeasuredvalues)shallbereadoutofthedevicememory.

Data logger functions

•Betteroverviewandfastnavigationbetweendifferentviewsthankstotabsasusedinawebbrowser.

•Divisionofprojectsintodifferentviewswithcleardesignationsofthetabsdonebytheuserhimself.

• It isno longernecessary tominimizeawindow toenable theuser to seewhathewantstosee.

•Automaticswitchingonaneventcontrolledbasisorviaactiveelementsinaprojectillustrationthate.g.servesasanoverview.

•The navigation betweenwork spaces can be restricted by password protection inordertoobligeusertooneparticularview.

•Thestructuraldivisionofthewindowsintoworkspacescanalsobefetchedviathewebserver.

Work spaces

Page 6: Software - Ahlborn · Software 05.07 06/2018 • We reserve the right to make technical changes. Function overviewy WC1 WC2 WC3 WC4 WCV Measured values - scanning Number of measuring

Software

05.11

06/2

018

• W

e res

erve

the r

ight to

mak

e tec

hnica

l cha

nges

.

•Two-pointcontrollers,proportionalcontrollers,andtime-basedcontrolsareavailable.• Itisalsopossible,usingarithmeticchannels,todefinePIDcontrollers.•Setpoint curves und process sequences can be specified by means of files withcoordinatespairs.

•Valuescanbespecifiedandprocesssequencescanbemodified-allviacommandbuttonsinprojecticonsorthetoolbar.

Control and regulation

•Measureddatacanbesavedtomemory-manuallyoronatime-controlledorevent-drivenbasis.

•Notonlydaily/weekly/monthlyfilescanbespecifiedbutalsofileswithanyrandomperiodsoftime.

•Dataissavedtomemoryautomaticallyinthebackground-irrespectiveofanyopeneddiagrams,tables,ordisplays.

•Measured value files can be exported automatically on completion of a save-to-memorycycleandbesentbye-mail(asanoptionwiththeeventslist).

Automatic saving-to-memory

•Measuredvaluefilescanbeincorporatedinneworalreadyexistinglinechartsintheformofcomparativecharacteristics.

•Folders containing a large number of measured value files can be convenientlygroupedusingvariouspatternsbasedonfilenamesandfiltersaccordingtotimeandmeasuringpoint.

•Localmaximumandminimumvaluescanbeshowninalinechartasanymeasuredvaluecurve required. Thesearch radiusbetweenmaximumandminimumcanbefreelyset.

Extended evaluation functions

Project illustrations

•Projectillustrationsallowforvisualizingthesetupofmeasurementsandprocessesbyusingindividuallydesignedgraphicsand/orphotographs(bitmaps).

•Thepresentationoftheacquireddataisprovidedinmeasuredvaluefieldsthatcanbefreelypositioned;sizeandcolors(includinglimitvalueviolation)canbefreelyselected.

•Textfieldscanbefilledwithlegendinformationanddescriptionsandcanbefreelypositioned.

•Bymeansofdynamictextfieldsitispossibletodisplaytextsinrelationtomeasuredvaluesorconditions.

•Allopeneddiagrams(linediagram,bardiagram,etc.)anddisplayscanbeinsertedasaliveelementandarrangedasdesired.

•Commandbuttons(keysandswitches)canbefreelypositionedintheproject iconand allow changes to values for performing calculations or controlling processes(switchingofrelaysorvalves,etc.).

•Thedesignofthecommandbuttonscanbechangedinanywayintheformoficons;themeasurementsetupcanthusbevisualizedinacompletelyintegratedway.

•Anynumberofproject illustrationscanbeopenedat thesame time,allowing, forexample,togiveapresentationofthetotalviewanddetailedviewsofaproject.

Page 7: Software - Ahlborn · Software 05.07 06/2018 • We reserve the right to make technical changes. Function overviewy WC1 WC2 WC3 WC4 WCV Measured values - scanning Number of measuring

05.12

Software06/2018 • W

e reserve the right to make technical changes.

•Combinationoftheoperationsanddisplayelementsintoaclearlystructuredoverallentity,focusingonfundamentalaspects.

•Directcontrolandprogrammingofdevices,testprocedures,andsoftwarefeatures.•Displayofconditions–visuallyorinformofpredefined,explanatory,changingtexts.• Integrationofopenedlinediagrams,bardiagrams,anddisplaysdirectlyinthepanel.•Theuserisabletocreatetheoperationanddisplaypanelsaccordingtohisownneedsbymeansoftheprojectillustration.

•Weoffertheservicetocreatepanelsincaseavisuallyappealingandsophisticatedsolutionisdesired.

Individual operation and display panels

•Thethermaltransmittance(U)wizardisavailableforOnlineandOfflinecalculations;itguidestheuserthroughalltherequiredsteps.

•Theusercanchoosefromaselectionofcalculationmethods-fortheexperimentalthermal transmittancevalue, for the thermal transmittancevalueaccording toDIN4108,andfortheofficialcalculatedvalue.

•Determinationofthecurrentlycalculatedvalueandtheslidingaveragevalue.•Thecalculationmethodswillbedescribedand theallocationof thecorrespondingmeasuringvariableswillbeprovided.

•Aftercompletingallstepsalinediagramwillbecreated,whichwill thenbefilledwiththemeasuringdataandthecalculatedvariables.

•Thecursor functioncanbeused toopen thestatistic table,whichprovidesfurtherevaluationoptions(seeabove).

Thermal transmittance (U) wizard

•CalculationofthermalcomfortasperDIN1946Part2andISO7730•Userguidancebymeansofawizardandeasy-to-understandevaluation•Output in the form of “predicted mean vote” (PMV) and “predicted percent ofdissatisfied“(PPD)

•Online and offline calculation of PMV and PPD in real time or on the basis ofmeasuredvaluesalreadyexisting

•Graphicalrepresentationofmeasureddataandcalculatedvaluesinaformatsuitableforexport(e.g.ASCII,MSExcel,DiaDEM,etc.)

•Calculationparameterscanbesavedasamodelforsubsequentcalculations.•AdditionalPMV/PPDfunctionsareavailableforuseinarithmeticchannels.

PPD / PMV wizard (comfort index measurement)

•Multilevelcalibrationviaself-definedcalibrationprogramswithsetpoint listsandstabilitycriterion

•Hardwareprofilewithsetpoint,referenceandcalibrationmeasuringpoints.•Automatedprocedurewithmeasuredvaluerecording•Driveacalibrator(setpointspecification)•Anydesirednumberofmeasuringpointscanbecalibratedsimultaneously•SavingthevaluesasAMR,CSVorExcelfile•Saving a configurable number of values per calibration step in case the stabilitycriterionismet

•Overviewwindowwithprogressbar•Thepriceforthemoduledependsonthenumberofcalibrationstationandcalibratorsthataretobesupportedsimultaneously.

Assistant for calibrating measuring sensors

Page 8: Software - Ahlborn · Software 05.07 06/2018 • We reserve the right to make technical changes. Function overviewy WC1 WC2 WC3 WC4 WCV Measured values - scanning Number of measuring

Software

05.13

06/2

018

• W

e res

erve

the r

ight to

mak

e tec

hnica

l cha

nges

.

•CalibrationaccordingtodirectiveDAkkS-DKD-R5-7•SupportofmethodsAandBwith9andmoremeasuringpoints• Intuitiveusernavigation•Analysisispossibleonlineaswellasoffline•Directinvolvementoftheclimatechambersintheonlinemeasurementoperation•Onlinevisualizationofthecalibrationprocessforallmeasuringpoints•Calculationoflocalhumiditymeasuredonthetemperaturemonitoringpoints•Determiningmeasurementuncertainties•Loggingofdeviationsfromthedisplayvalue•Automatic,convenientanalysiswithprotocolcreationinPDFformat.

Assistant for the calibration of climate chambers

δQ = cv • m • dT

•The thermal quantity is calculated automatically from the volume flow and thetemperaturedifference.

•Youcanentersettingseasilyandconvenientlyusingthewizard.•Datatablesforwaterareincludedindelivery;userscandefinetheirownextensionsforothermediathemselves.

•Thethermalquantitycanbecalculatedinrealtimeoronthebasisofexistingmeasuredvaluefiles.

Thermal quantity wizard

•Thanks to the integrated user management system, unauthorized access toAMRWinControlisimpossible.Thispolicyreducesthesecurityriskstoaminimum.

•Everychangeofuserisloggedintheeventslistforsubsequentevaluation.•Accessrightscanbedefinedindividuallyperuserorcanbecopied.•Accesslimitationscanbedefinedforeverysingleprogramfeature.•Alarmconfirmationscanbeassignedunequivocallytoparticularusers.•The password protection is the minimum requirement for the system validationaccordingtoFDA21CFRPart11.

Password protection

•The data files can be, Online and/or at any later point in time, stored in thefollowing formats Excel (XLS / XLSX), ASCII (TXT / CSV), WK1, FAMOS,QS-STAT,DIAdem.

•WithODBCmeasured data can be exported in SQL databases (structured querylanguage).ThissupportsalldatasourcesforwhichanODBCdriverisinstalledandsetuponthesystem.

•The line andXYdiagrams and the tables canbe copied to the clipboard and, forexample,beinsertedintoaprotocoltext.

•Viadynamicdataexchange(DDE)itispossibletotransfermeasuredvaluesOnlinetootherapplications,forexampleMS-EXCEL.

•Furthermore,linediagramscanbeembeddedintotextdocuments(e.g.aMSWorddocument)viatheOLEfunction.

Data Export:

Page 9: Software - Ahlborn · Software 05.07 06/2018 • We reserve the right to make technical changes. Function overviewy WC1 WC2 WC3 WC4 WCV Measured values - scanning Number of measuring

05.14

Software06/2018 • W

e reserve the right to make technical changes.

•„Openness,Productivity,andCollaboration”•OPC isanestablished industrial standard foraccessproceduresonamulti-vendorbasisirrespectiveofmanufacturer.

•AMRWinControloperatesasanOPCclient;itwritescurrentmeasuredvaluestotheglobalvariablesprovidedbyanOPCserver.

•DatacanbetransferredinparalleltoseveralOPCservers.•Data fromAMRWinControl can, with the aid of OPC, be visualized online inLabView™.

OPC export: Process control system connection

•Opendatabaseconnectivity•ODBCisastandardizeddatabaseinterfaceusedbySQLasitsdatabaselanguage.•Recordedmeasuredvaluescanthusbetransferredtoadatabase.•Currentmeasuredvaluescanbeinterrogatedfromadatabasepermeasuringcycle.•AsuitableODBCdriverforthedatabasemustbeinstalledandsetuponthesystem.

ODBC support: SQL database connection

•AMRWinControlcanhandlesinglemeasuringinstrumentsaswellasanetworkofmeasuringinstrumentsoftheALMEMO®series.

•Theconnectiontothemeasuringinstrument(s)canbeestablishedviaserialinterface,USB,Bluetooth,ormobilemodem.

• Inasimilarway,themeasuringinstrumentscanbeaddressedviaacomputernetwork(TCP/IPaddress)andVPN.

•Connectionscanbesetuponatime-controlledbasis.ReadingoutfromthememoryonALMEMO®devicescanbeautomated.Thememorycanonrequestbeclearedandsavingtomemorycanberesumedautomatically.Anyproblemsencounteredarenotedintheeventslist.

•Viamobile radio it is possible to establish connections to devices that have beeninstalledinremotelocations.Theconnectioncanbeestablishedinexpensivelyandpermanently,asthebillingisvolume-oriented.

Connecting Options

•Severalautosavemanagerscanbeoperatedandorganizedviaaconvenient,easy-to-usegraphicaluserinterface.

•Measureddatacanthusbesavedsimultaneouslytodifferentfiles.•Autosavemanagers can be started and stopped independently of one another andaccordingtovariouscriteria(time-drivenorevent-driven).

•Differentmeasuringlocations(operatinginparallel)canthusbetreatedseparately.•Measuredvaluefilescanbeindicatedaswrite-protectedalreadyduringrecording.• Including10autosavemanagers(optionallymoreavailable)• Ifrequired,weoffertoimplementindividualautomationsofteststationsincludinginput of test parameters, test procedure, signaling (optical/acoustic), and protocolprintout.

Test bench manager

Page 10: Software - Ahlborn · Software 05.07 06/2018 • We reserve the right to make technical changes. Function overviewy WC1 WC2 WC3 WC4 WCV Measured values - scanning Number of measuring

Software

05.15

06/2

018

• W

e res

erve

the r

ight to

mak

e tec

hnica

l cha

nges

.

•Withthemeasuredvalueserverupto200userssimultaneouslycanaccesscurrentmeasured values and the measured values history via a TCP network (Intranet /Internet).

• Interfacetoanydataacquisitionandprocesscontrolsystem•Online transmission of measured data to other operating systems (e.g. LINUX,WINDOWSCE,UNIX,etc.)

•Datadistributionaccordingtoanyspecifiedcriteria•CustomizedsolutionscanbeimplementedusingstraightforwardASCIIcommandsissuedviatheTCPprotocol;allthesecommandsarefullydocumented.

•Open“read-only”interfaceforanyuser-definedconnectionsoftware•“REMOTEWinControl”and“WinControlClientOCX”providepowerfulstandardsolutionsforthemeasuredvalueclients.

Measured value server

•Optionally,AMRWinControlofferssupportforprotocolsformeasuredvalueenquiryfromdevicesfromothermanufacturerssimultaneouslyforanynumberofconnections.

•MODBUS:flexibleprotocolandindustrystandard•CANBus:withPEAK-CANorUSB2CANadapter•OPCDA:measureddataacquisitionfrommeasuringdevices/systemsordatatransfertoanOPCserver(e.g.LabView)

•ODBC:SQLdatabase(Oracle,MSSQL,MySQL,…)•Climate chambers: Feutron®, CTC, Binder, Memmert, Vötsch, and WeissUmwelttechnik,ESPEC

•Dewpointmirror:DPM373,DewMaster•Gasanalyzers:ECOPhysicsCLD8xx,ABB,MRUNovaH8,aswellasEmersondevicesX-Stream,MLT,CLD,andNGA

•Power meters & energy meters:YokogawaWT230 &WT310, Janitza®, Infratek106A&108A,Simeas-T,andHioki

•Calibrators:Julabo,ISOTECH,AMETEK®(JofraTM),JOFRA(ATC/RTC)•Precisionmeasuringdevice:Fluke8508A(withfullprecision)•Barcodescannerprotocol:network-compatibleandserialscanners•SimpleASCII:implementationofyourownmeasuringdevices•The use of AMRWinControl for acquiring measured data of further devices ispossibleuponrequest.

System integration

•Acquisition of barcodes in text format via USB, TCP/IP or Bluetooth by usingappropriatescanners.

•Analysisofthebarcodetocontrolprogramfeatures(e.g.automaticsaving)andtestprocedures.

•Thebarcodeisautomaticallyimportedintothenameofthefile.•Displayof thescannedbarcode in text formatandstorageofnumericbarcodes inmeasuredvaluefiles.

•Severalscannerscanbeoperatedinparallel.

Barcode scanner protocol

•Withafewclicks,recordedmeasuredvaluescanbeprintedoutasaprotocol.•The customer can create his own individual templates or customize the availablesampletemplates.

•The protocol may include the line graph, measured values, calculated variables,times,andcomments.

• IdealforcompilingmeasurementreportsorprotocolsforcustomerswithouthavingtobotherwithExcelanddataexport

Protocol printout new

Page 11: Software - Ahlborn · Software 05.07 06/2018 • We reserve the right to make technical changes. Function overviewy WC1 WC2 WC3 WC4 WCV Measured values - scanning Number of measuring

05.16

Software06/2018 • W

e reserve the right to make technical changes.

•AMRWinControl provides a full range ofweb server functions for publishingwebpages(HTML)intheIntranet/Internet.ItalsoincorporatesadditionalfunctionsthatcanbeusedtooutputthecontentsofAMRWinControlwindowsdirectlyontowebpages.

•Currentmeasuredvaluesandmeasuredvaluehistoriescanbedisplayedinavarietyofways(linediagrams,XYdiagrams,projectillustrations)intheIntranet/Internet.

•Visualizationofprocessesandsystems•Visualremotemonitoring•Confirmation of alarms via the browser (only with alarm function and passwordprotection)

•Linkingpresentationandreal-timedataonwebpages•Theway inwhichmeasured values are displayed does not depend on the operatingsystem;onlyabrowserisneeded(MSInternetExplorer,Firefox,Chrome,Opera,etc.).

•DiagramsandmeasuredvaluescanalsobedisplayedonsmartphonesandtabletPCs.•SecurityprovidedbySSL/TLSanduserauthentication•Veryeasytouse:Imagesgeneratedfromthecontentsofawindowcanbetransmittedassoonastheprogramstarts-withoutneedinganyfurthersettings.ForparticularlydemandingtaskstheHTMLpagesmustfirstbeadaptedandconnectedtothewebserver.

•Thewidevarietyofimageformatsandspecialparametersmakefortransparencyandloss-free scaling and permit automatic updating. Powerful real-time compressionalgorithmsminimizethevolumeofdatatobetransmitted.

•All the layout facilities available inHTML,DHTML, andCSS can be exploited;combiningwithJavaScriptisalsopossible.

•Graphics,text,andmeasuredvaluedisplayscanbecombinedandmergedcompletelyseamlessly.

•Thewebdesignerisfreetospecify,moreorlessindependentlyofAMRWinControl,howthemeasuredvaluedisplaysaretoappear.

•Theuserreceivescurrentmeasureddatawithoutbeingexposedtoanysortofsecurityrisk-becausethereisnoneedforJavaorspecialplug-ins.

Web server

Thispackage,basedontheAMRWinControl“professional”version,containsalltheoptions andmodules needed to implement long-term and continuousmonitoring ofcriticalmeasurablevariables.• Integratedusermanagementwith individually settable access rights andpasswordprotection

•Tamper-proofeventlistwithsortandfilterfunctions•Trendmonitoring-pre-alarmforsignalingtrenddevelopments•Signalingofalarmsandeventswithuser-specificconfirmationandcomments•Alarmconfirmationperwebserver(authenticationandSSL/TLSavailable)•Schedules:AutomaticswitchingON/OFFofalarmtreatmentforeachmeasuringpoint,e.g.alarmtreatmentonworkingdaysbetween06and18o’clockonly.

•Temporarily withdrawing certainmeasuring points from alarm treatment, e.g. fordefrostingacoldroom

• IntheeventofalarmanMS-Excellogcanbeprintedoutautomatically.Userscanmodifythelogprovidedorcreatetheirown.

•Failsafe:Automaticreadingoutofthedevicememoryafterlossofconnectiontothedevice

•Requirements:ALMEMO®devicewithfailsafemodeandinternalmemory•Systemconfiguration• Integritycheckonallmeasuringpointsandmeasuringinstrumentsafterprogramstart•Processingofmeasuredandcalculatedvariablesincontrolandregulationfunctions•Automaticprintoutand/ore-mailwithdailyfilesandeventlists• Includingsecuritypackage.

Security package •Datasecurity:Automaticbackupofallautomaticallyrecordeddata(dailyandweeklyfiles,measuredvaluesrecordedonanevent-controlledbasis,eventlists,etc.)

•Fail-safe : In the event of failure awatchdog is triggered for PC restart and / orsignalingviarelay.

• Includingwatchdogcard

SW5600WCV Package for long-term / continuous monitoring

Page 12: Software - Ahlborn · Software 05.07 06/2018 • We reserve the right to make technical changes. Function overviewy WC1 WC2 WC3 WC4 WCV Measured values - scanning Number of measuring

Software

05.17

06/2

018

• W

e res

erve

the r

ight to

mak

e tec

hnica

l cha

nges

.

•SimultaneousacquisitionofmeasuredvaluesfromALMEMO®devicestogetherwithvideodatafromadigitalsource

•Themeasureddataandvideosignalaresynchronizedanddisplayedtogether.•Themodesavailablearepreview,record,andplayback.•PIMEXplayerisincludedintheprofessionalversion(WC3).Therecordingfunctionisavailableasmodule(ZM14).

•Possible applications : Documentation / visualization of the process environment(e.g.forsafetyintheworkplace,qualitymanagement,etc.)

PIMEX: combined measured value recording and video recording

•AMR WinControl incorporates a copy protection system which requires a PC-dependent code to enable it. To receive this code the usermust first register thesoftwareby telephone, fax,ore-mail. Per licencepurchased thesoftwaremaybeinstalledandoperatedononecomputer.

• Itisalsopossibleasanoptiontorequestahardwarecopyprotectionmechanism,adongle;withthisthesoftwarecanbeinstalledonanynumberofcomputersbutwillonlyrunonthatPCintowhichthedongleiscurrentlyplugged.

•Anetworkdonglemaycontainmorethanonelicence;withthisitispossible-withouttheinconvenienceofmovingthedongle-torunthesoftwaresimultaneouslyonasmanycomputersinacompanynetworkastherearelicencesencodedinthedongle.

Copy protection

Components: Minimumconfiguration RecommendedconfigurationComputer Windows-PC(x86/x64) Windows-PCOperatingsystem WindowsVista,7,8.1,10,2008,2012 Windows7,8,10 (32and64bit)Memory 2048MB 4096MBFreehard-diskcapacity 30MB 100MBInterfaces USB COM(RS232),USB,networkcard

AMR WinControl system requirements

•SynchronousrecordinganddisplayofmeasureddataandCANmessages•NavigationwithcursorinthelinegraphanddisplayoftheassociatedCANmessagesinatable

•ConfigurabledecodingandcolorhighlightingoftheCANdata•SearchandfilteringoftheCANdata•ExportofCANdatatoaTRCfile• ImportofCANdatafromaTRCfiletomeasureddata•SupportofPEAK-CANadapter(USBorPCIe)

CAN trace: combined measured value recording and CAN data recording new