SM-CS-ART2-L SM-CS-ART2-XL - Staub Electronics Ltd.SM-CS-ART2-L SM-CS-ART2-XL Strong™ Contractor...
Transcript of SM-CS-ART2-L SM-CS-ART2-XL - Staub Electronics Ltd.SM-CS-ART2-L SM-CS-ART2-XL Strong™ Contractor...
SM-CS-ART2-LSM-CS-ART2-XL
Strong™ Contractor Series Universal Articulating Mount With Dual Arms
INSTRUCTION MANUAL
WARNINGS:• Makesuretheseinstructionsarereadandthoroughlyunderstoodbeforeattemptinginstallation.Ifyouareunsureofanypartoftheinstallation
process,contactaprofessionalinstallerforassistance.
• Thewallormountingsurfacemustbecapableofsupportingthecombinedweightofthemountandthedisplay;otherwisethestructuremustbereinforced.Installerisresponsibleforverifyingthewall/mountingsurfaceandtheanchorsusedcansupportthetotalloadoftheinstallation.
• Safetygearandpropertoolsmustbeused.Failuretodosocanresultinpropertydamageand/orseriousinjury.
• Aminimumoftwopeopleisrequiredforthisinstallation.Donotattempttoinstallthismountaloneunderanycircumstance.Wehighlyrecom-mendthisproductbeinstalledbyaqualifiedprofessionalperson.
• Followallinstructionsandrecommendationsregardingadequateventilationandsuitablelocationsformountingyourdisplay.Consulttheowner’smanualforyourdisplayformoreinformation.
PACKAGE CONTENTS:
SPECIFICATIONS:• MaximumLoad:150lbs.(68.04kg)
• DisplaySize:42”to63”
• MaximumExtension:30-5/8”
• Wiremanagement
• Pan/SwivelRange:180°
• TiltRange:-5°/+15°
BOX CONTENTS:• WallArmAssembly(1)
• AdapterBracket(2)
• AdapterPanel(1)
• Hardwarekit(1)
TOOLS REQUIRED: • PowerDrill
• 1/4”&5/16”DrillBits
• Level
• 13mm(1/2”)SocketWrenchorShifter
• Hammer
• StudFinder
(A)M4x15mmPhilipsHeadScrew(x4)
(D)M8x15mmPhilipsHeadScrew(x4)
(N)M6x12mmPhilipsHeadScrew(x4)
(O)M8x15mmPhilipsHeadScrew(x4)
(P)36.2x36.2x2.5mmSquareWasher
(Q)M10x70ConcreteWallAnchors(x6)
(R)6x13x1.2mmMetalWasher(x4)
(S)AllenKey(x1)
(T)RecessedHoleSpacer(x4)
(U)Spacer(x4)
Template(x1)
WireManagementCaps
WallArmAssembly(x1)
AdapterBracket(x2)
AdapterPanel(x1)
(E)M4x35mmPhilipsHeadScrew(x4)
(F)M5x35mmPhilipsHeadScrew(x4)
(G)M6x35mmPhilipsHeadScrew(x4)
(H)M8x35mmPhilipsHeadScrew(x4)
(I)M4x45mmPhilipsHeadScrew(x4)
(K)M6x45mmPhilipsHeadScrew(x4)
(J)M5x45mmPhilipsHeadScrew(x4)
(L)M8x45mmPhilipsHeadScrew(x4)
(M)FlangeBolt(x6)
(B)M5x15mmPhilipsHeadScrew(x4)
(C)M6x15mmPhilipsHeadScrew(x4)
CAUTION: This wall mount is intended for use only with the maximum weight of 150 lbs. Use with heavier than the maximum weight indicated may result in instability causing possible injury.
M4x20PhilipsHeadScrew(x4)
M5x20PhilipsHeadScrew(x4)
M6x20PhilipsHeadScrew(x4)
M8x20PhilipsHeadScrew(x4)
PG 1
INSTALLATION
Step 1: Use template to mark mounting hole locations for flange boltsNote:Cornersfolduptocatchdebris,ifneeded.
Step 2: Pre-drilling
For Mounting on a Stud WallPre-drillholesintostudsusinga1/4”drillbit.
WARNING:
Tighten screws so that wall plate is firmly attached, but do not overtighten. Overtightening can dam-age the screws, greatly reducing their holding strength.
Make sure that mounting screws are anchored into the center of the studs. The use of a stud finder is highly recommended.
For Mounting on a Concrete Wall
Pre-drillholesintoconcreteusing5/16”drillbits.Insertconcretewallanchorsandtapinwithhammer,ifnecessary.
WARNING:
When installing wall arm assembly on cinder block, verify first that you have a minimum of 1-3/8” of concrete thickness to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally1” minimum from the side of the block. Cinder block must meet ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
Concrete must be 2000 psi density minimum. Lighter density concrete may not hold con-crete anchor.
Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
Drill holes and insert anchors.
Place wall assembly arm with plate
over anchors and secure bolts.
Tighten all fasteners.
flange bolts
wall plate
concretewall
Correct
concreteconcrete
plaster/drywall
plaster/drywall
Incorrect
Cuta
way
Vie
w
PG 2
Step 3: Mount the Arm Assembly
For Mounting on a Stud Wall or Concrete Wall
Insertflangeboltsthroughthewallplateintothestudsorthewall
anchors.WhenInstallingonconcrete,6boltsareneeded.Insertfour
throughtopsetofholes;twoonthefarholes,andtwonearthecenter.
Inserttheremainingtwoboltsonthebottomsetofholes.
Step 4 : Mounting the Assembled Adapter Plate to Screen
Modify the Assembled Adapter Plate
SlidetheAdapterBracketsontoAssembledAdapterPlate
rods.PlacetheassembledAdapterPlateonthebackofthe
displaywithoneAdapterBracketalignedwithasetofvertical
mountingholes.Then,slidetheotherAdapterBracketinor
outuntilitalignswiththesecondsetofverticalmounting
holes.TheAdapterPlateshouldbehorizontallycenteredonthe
backoftheflatpaneldisplay.
UsefourM6x12screwsandfourmetalwashersandtighten
AdapterBracketstoAdapterPlaterodswithaPhillipsHeadScrew
Driver.
NOTE: There are eight positions for flexibility. Move the Adapter Brackets to desired location. Adapter Brackets can be flipped around (if required).
AttachtheAdapterBracketsusingfourmountingscrewsand
foursquarewashers(sizewilldependonthreadpatternonflat
panelbeinginstalled).Oncealigned,tightenallscrewsdown
withaPhillipsHeadScrewDriver.
InserttwoM8HexheadscrewsonthetopoftheAdapterPlate
withtheM6AllenWrench.DO NOT IMMEDIATELY TIGHTEN
DOWN!
M8 Hex head screws w/washers
Back ofDisplay
MountingScrew
Square Washer
Adapter Plate
AdapterBracket
Metal Washer(6 x 13 x 1.2)
M6 x 12Screw
PG 3
Mounting Head
Tilt Levers
M8 Hex head screws w/washers
wall plateCONCRETE WALL
wall anchor
flange bolt
Step 5: Attaching Screen to Wall Arm Assembly
LiftthedisplayandhookthetwoHexheadscrews
withmetalwashersingroovesontopoftheMounting
Head.InserttwomoreHexheadscrewswithwashersin
bottomtwoholesoftheMountingHead,securingitto
theAdapterPlate.Thentightenallfourscrewswiththe
AllenWrench.
NOTE: For demonstration purposes, the wall has been omitted from the illustrations.
NOTE: This procedure will require two persons. Ensure that the arm is set to its maximum negative tilt prior to attaching the display.
Step 6: Running Cables
RunasshownandinstallWireManagementCaps.
NOTE: Make sure cords have enough slack to allow full movement of the arm.
Wire Management Caps
Figure 14Rubber AdhesiveSafety Pads (W)
Figure 15
PG 4
ADJUSTMENTS:Adjust Horizontal Level and TiltStep 5: Tilt Adjustment
A. LoosenTilt Leversoneachsideofmounthead
(Onlyenoughtoallowcontrolledadjustment)
B. AdjustTilt
C. LockTilt Levers( Tighten)
D. OnceTilt Leversarelocked,thepositionofthe
leverscanbeadjusted,withoutlooseningor
tighteningtheunit, bypullingtheleversoutwards
andthenrepositioningthemtoavertical, less
obtrusiveposition.
Step 6: Horizontal Adjustment
A. Toadjustthehorizontalangleofthedisplay,f irstsl ightlyloosenthetoptwoscrewsonbacksideofWall ArmAssemblymountingheadusingAllenKey( T ). Thenfirmlyholdoppositecornersofthedisplayandgentlyturnit intothedesiredposition.Whenlevel, re -tightenscrewstolockintheposition.
OTHER FEATURES:Cable ManagementInstall cordcoversasshown.Besuretoleaveenough
slacktoallowformovementofthearms.
Optional Adhesive Rubber PadIncludedwithhardwarepackarerubberpads(W )
forcushioningimpactofarmagainstthewall when
retractingmount.Placepadsonoppositesideofcable
managementcoverswherepossibleimpactpointswill
occur.
PG 5
CONTACTING TECHNICAL SUPPORT
Phone: (866) 838-5052Email: [email protected]
PG 6
LIFETIME LIMITED WARRANTY
Strong™ Mounts have a Lifetime Limited Warranty. This warranty includes parts and labor repairs on all components found to be defective in material or workmanship under normal conditions of use. This warranty shall not apply to products which have been abused, modified or disassembled. Products to be repaired under this warranty must be returned to Snap AV or a designated service center with prior notification and an assigned return authorization number (RA).
Lifetime
120822-1100©2012STRONG
engineered by