SK-SU & SK-TL - Solax Power2 1 4000 550 360 125-530 12/12 15/15 2 1 3300 12 15 1 1 3300 5000 12/12...
Transcript of SK-SU & SK-TL - Solax Power2 1 4000 550 360 125-530 12/12 15/15 2 1 3300 12 15 1 1 3300 5000 12/12...
SOLAR ENERGY
More than just an inverter, the innova�ve X-Hybrid is an intelligent energy management system that stores surplus energy in ba�eries for later use.
X-HYBRID From SolaX
SOLAR ENERGYON DEMAND
Day & Night
Get in touch now:
Global: +86 571-56260008AU: +61 1300 476529Website: www.solaxpower.com
SK-TL / SK-SU
The X-Hybrid works by storing surplus energy in ba�eries for later use, making it possible to u�lise solar power �me-independently by storing unused capacity. It converts and directs solar power to where it is needed, when it is needed. X-Hybrid is also supplied with a built-in EPS, allowing the end-user to use their stored energy in the event of a power outage.
WITH EXTERNAL CHARGER
BMU
DE: +49 7231 4180999UK: +44 2476 586998Email: [email protected]
X1-Hybrid Ready Inverter SK-TL X1-Hybrid Inverter SK-SU
SK-SU3000E SK-SU3700E SK-SU5000ESK-TL3000E SK-TL3700E SK-TL5000EINPUT (DC)
OUTPUT AC
DISPLAY
Max. recommended DC Power [W]
Max. DC Voltage [V]
Nominal DC operating voltage [V]
MPPT voltage range [V]
Max. input current [A]
Max. short circuit current [A]
No. of MPP trackers
Strings per MPP tracker
AC Nominal Power (W)
Nominal AC Voltage; Range (V); Frequency [Hz]
AC Nominal Current (A)
Max. AC Current (A)
Total Harmonic Distortion (THD) [%]
Power Factor (Rated Power)
Displacement power factor
EFFICIENCY
MPPT efficiency [%]
Euro efficiency [%]
Max. efficiency [%]
Standby Losses [W]
LCD
Communications
Led light
Button
BATTERY CHARGER (INTERNAL)
Compatible Battey Type
Nominal Battery Voltage [V]
Battery Voltage Range [V]
Max. Charging Current [A]
Charging Curve
Over Current Protection/Over Temperature Protection
Communication Interfaces
4000
550
360
125-530
12/12
15/15
2
1
4000
550
360
125-530
12/12
15/15
2
1
3300
12
15
1
1
3300 5000
12/12
15/15
2
1
5000
3680
230,180~270; 50/60
16
16
<3
1
0.8 leadlng to 0.8 lagging
99.9
97.0
97.6
<7
3000
13
14.4
4600
20
21.7
Backlight 16*4 character
Ethernet/WiFi/ Dry Contact/Meter(optional)
4
4
Leading-acid battery/lithium battery
48
40-60
50(adjustable)
3-stage adaptive with maintenance
Yes
Can/RS232
3000
13
14.4
3680
230,180~270; 50/60
16
16
<3
1
0.8 leadlng to 0.8 lagging
4600
20
21.7
99.9
97.0
97.6
<7
Backlight 16*4 character
Ethernet/WiFi/Dry Contact/Meter(optional)
4
4
Leading-acid battery/lithium battery
48
40-60
50(adjustable)
3-stage adaptive with maintenance
Yes
Can/RS232
OTHERS
DC switch
MAx. No, of Supported External ChargeroOperating Temperature Range [ C]
oStorage Stability Range [ C]
Altitude Limit [m]
Cooling Concept
Noise Emission (typical) [dB]
Humidity [%]
Protection Class
Overvolatge Category
EMC Standard
Topology
Warranty [years]
Dimensions W*H*D [mm]
Weight [kg]
Certification
Optional
0
-10~+50 (derating at 40)
-20~+60
<2000
Forced airflow
<40
0~95 (non-condensing)
IP20 (indoor use)
III (electic supply side), II (PV SIDE)
IEC61000-6-1/2/3
Transformer-less
5-10
700*591*151
27.7
Optional
1
-10~+50 (derating at 40)
-20~+60
<2000
Forced airflow
<40
0~95 (non-condensing)
IP20 (indoor use)
III (electic supply side), II (PV SIDE)
IEC61000-6-1/2/3
Transformer-less
5-10 (Dependent On Territory)
475*591*151
21.5
X-HYBRID INVERTER (EMERGENCY POWER SUPPLY)EPS (WITH INTERNAL CHARGER)
EPS Rated Power [VA]
EPS rated Voltage[V], Frequency [Hz]
EPS Rated Current [A]
EPS Peak Power [A];Duration [s]
Total Harmonic Distortion (THD) [%]
Switch Time [s]
2000
230,50/60
8.7
1.5xRrated, 10
<3
<5
2000
8.7
1.5xRrated, 10
2000
8.7
1.5xRrated, 10
2000(50A)/3680(100A)
230, 50/60
8.7/16
1.5xRrated, 10
<3
<5
2000(50A)/4000(100A)
8.7/17
1.5xRrated, 10
2000(50A)/3000(100A)
8.7/13
1.5xRrated, 10
VDE 4105 / AS/NZS4777.2 / C10 11 / EN50438-NL / EN50438-DK / OVE/ONORME 8001/ G83,G59 / CEI 0-21 VDE 4105 / AS/NZS4777.2 / C10 11 / EN50438-NL / EN50438-DK / OVE/ONORME 8001/ G83,G59 / CEI 0-21
X1-Hybrid Ready Inverter X1-Hybrid InverterX1-Hybrid X1-Hybrid