SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F...

17
SITRANS F flowmeters SITRANS F M Transmitter MAGFLO MAG 5000/6000 4/26 Siemens FI 01 · 2008 4 Overview Transmitter MAG 5000/6000 compact version (left) and 19“ insert version (right) The MAG 5000 and 6000 are microprocessor-based transmitters engineered for high performance, easy installation, commission- ing and maintenance. The transmitters evaluate the signals from the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F, MAG 3100 and MAG 5100 W. Transmitter types: MAG 5000: Max. measuring error 0.5% of rate (incl. sensor) MAG 6000: Max. measuring error 0.25% of rate (incl. sensor, see also sensor specifications) and with additional features such as: Plug & Play insert bus modules; integrated batch functions. Benefits Superior signal resolution for optimum turn down ratio Digital signal processing with many possibilities Automatic reading of SENSORPROM data for easy commis- sioning User configurable operation menu with password protection. 3 lines, 20 characters display in 11 languages. Flow rate in various units Totalizer for forward, reverse and net flow as well as additional information available Multiple functional outputs for process control, minimum con- figuration with analogue, pulse/frequency and relay output (status, flow direction, limits) Comprehensive self-diagnostic for error indication and error logging (see under SITRANS F M MAGFLO diagnostics) Batch control Custody transfer approval: PTB, OIML R75, R117, OIML R 49 and MI-001, MAG 6000 with add-on bus modules for HART, MODBUS RTU/RS485, PROFIBUS PA and DP Application The MAG flowmeters are suitable for measuring the flow of al- most all electrically conductive liquids, pastes and slurries. The main applications can be found in: Water and waste water Chemical and pharmaceutical industries Food & beverage industries Power generation and utility Design The transmitter is designed as either IP67 NEMA 4X enclosure for compact or wall mounting or 19" version as a 19” insert as a base to be used in: 19" rack systems Panel mounting IP65/NEMA 4 Back of panel mounting IP20/NEMA 2 Wall mounting IP66/NEMA 4 Several options on 19” versions are available such as: Transmitters mounted in safe area for Ex ATEX approved flow sensors (incl. barriers) Transmitters with electrode cleaning unit Function The MAG 5000/6000 are microprocessor-based transmitters with a build-in alphanumeric display in several languages. The transmitters evaluate the signals from the associated electro- magnetic sensors and also fulfil the task of a power supply unit which provides the magnet coils with a constant current. Further information on connection, mode of operation and instal- lation can be found in the data sheets for the sensors. Displays and controls Operation of the transmitter can be carried out using: Control and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communica- tion PC/laptop and SIMATIC PDM software using PROFIBUS or MODBUS communication HART communication PROFIBUS PA communication © Siemens AG 2007

Transcript of SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F...

Page 1: SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F flowmeters SITRANS F M ... the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F,

SITRANS F flowmetersSITRANS F M

Transmitter MAGFLO MAG 5000/6000

4/26 Siemens FI 01 · 2008

4

Overview

Transmitter MAG 5000/6000 compact version (left) and 19“ insert version (right)

The MAG 5000 and 6000 are microprocessor-based transmitters engineered for high performance, easy installation, commission-ing and maintenance. The transmitters evaluate the signals from the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F, MAG 3100 and MAG 5100 W.

Transmitter types:• MAG 5000: Max. measuring error 0.5% of rate (incl. sensor)• MAG 6000: Max. measuring error 0.25% of rate (incl. sensor,

see also sensor specifications) and with additional features such as: Plug & Play insert bus modules; integrated batch functions.

Benefits

• Superior signal resolution for optimum turn down ratio• Digital signal processing with many possibilities• Automatic reading of SENSORPROM data for easy commis-

sioning• User configurable operation menu with password protection. • 3 lines, 20 characters display in 11 languages.• Flow rate in various units• Totalizer for forward, reverse and net flow as well as additional

information available• Multiple functional outputs for process control, minimum con-

figuration with analogue, pulse/frequency and relay output (status, flow direction, limits)

• Comprehensive self-diagnostic for error indication and error logging (see under SITRANS F M MAGFLO diagnostics)

• Batch control• Custody transfer approval: PTB, OIML R75, R117, OIML R 49

and MI-001,• MAG 6000 with add-on bus modules for HART,

MODBUS RTU/RS485, PROFIBUS PA and DP

Application

The MAG flowmeters are suitable for measuring the flow of al-most all electrically conductive liquids, pastes and slurries. The main applications can be found in:• Water and waste water• Chemical and pharmaceutical industries• Food & beverage industries• Power generation and utility

Design

The transmitter is designed as either IP67 NEMA 4X enclosure for compact or wall mounting or 19" version as a 19” insert as a base to be used in:• 19" rack systems• Panel mounting IP65/NEMA 4• Back of panel mounting IP20/NEMA 2• Wall mounting IP66/NEMA 4

Several options on 19” versions are available such as:• Transmitters mounted in safe area for Ex ATEX approved flow

sensors (incl. barriers)• Transmitters with electrode cleaning unit

Function

The MAG 5000/6000 are microprocessor-based transmitters with a build-in alphanumeric display in several languages. The transmitters evaluate the signals from the associated electro-magnetic sensors and also fulfil the task of a power supply unit which provides the magnet coils with a constant current.

Further information on connection, mode of operation and instal-lation can be found in the data sheets for the sensors.

Displays and controls

Operation of the transmitter can be carried out using:• Control and display unit• HART communicator• PC/laptop and SIMATIC PDM software via HART communica-

tion• PC/laptop and SIMATIC PDM software using PROFIBUS or

MODBUS communication

HART communication

PROFIBUS PA communication

98&

: !""

;'9<&6

6 ! "

=6> &

<

/

<

© Siemens AG 2007

Page 2: SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F flowmeters SITRANS F M ... the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F,

SITRANS F flowmetersSITRANS F M

Transmitter MAGFLO MAG 5000/6000

4/27Siemens FI 01 · 2008

4

Technical specifications

Mode of operation and design

Measuring principle Electromagnetic with pulsed con-stant field

Empty pipe Detection of empty pipe (special cable required in remote mounted installation)

Excitation frequency Depend on sensor size

Electrode input impedance > 1 x 1014 Ω

Input

Digital input 11 ... 30 V DC, Ri = 4. 4 KΩ

• Activation time 50 ms

• Current IDC 11 V = 2.5 mA, IDC 30 V = 7 mA

Output

Current output

• Signal range 0 ... 20 mA or 4 ... 20 mA

• Load < 800 Ω

• Time constant 0.1 … 30 s, adjustable

Digital output

Frequency 0 ... 10 kHz, 50% duty cycle (uni/bidirectional)

Pulse (active) DC 24 V, 30 mA, 1 KΩ ≤ Ri ≤ 10 KΩ, short-circuit-protected (power supplied from flowmeter)

Pulse (passive) DC 3 … 30 V, max. 110 mA, 200 Ω ≤ Ri ≤ 10 KΩ (powered from connected equipment)

Time constant 0.1 … 30 s, adjustable

Relay output

Time constant Changeover relay, same as cur-rent output

Load 42 V AC/2 A, 24 V DC/1 A

Low flow cut off 0 ... 9.9% of maximum flow

Galvanic isolation All inputs and outputs are galvan-ically isolated

Max. measuring error (incl. sen-sor and zero point)

MAG 5000 0.5% of rate

MAG 6000 0.25% of rate

Rated operation conditions

Ambient temperature

• Operation • Display version:-20 ... +50 °C (-4 ... +122 °F)

• Blind version:-20 ... +60 °C (-4 ... +140 °F)

• Storage -40 ... +70 °C (-40 ... +158 °F)

Mechanical load

Compact version 18 ... 1000 Hz, 3,17 G rms, sinu-soidal in all directions to IEC 68-2-36

19“ insert 1 ... 800 Hz, 1 G, sinusoidal in all directions to IEC 68-2-36

Degree of protection

Compact version IP67/NEMA 4X to IEC 529 and DIN 40050 (1 mH2O 30 min.)

19“ insert IP20/NEMA 2 to IEC 529 and DIN 40050

EMC performance

Emitted interference To EN 50081-1 (Light industry)

Noise immunity To EN 50082-1 (Industry)

Display and keypad

Totalizer Two eight-digit counters for for-ward, net or reverse flow

Display Background illumination with alphanumeric text, 3 x 20 charac-ters to indicate flow rate, totalized values, settings and faults; Reverse flow indicated by nega-tive sign

Time constant Time constant as current output time constant

Design

Enclosure material

• Compact version Fiber glass reinforced polyamide; optional (IP67 only): AISI 316 stainless steel

• 19“-insert Standard 19“ insert of alumin-ium/steel (DIN 41494), width: 21 TE, height: 3 HE

• Back of panel IP20/NEMA 2; Aluminium

• Panel mounting IP65/NEMA 4; ABS plastic

• Wall mounting IP66/NEMA 4; ABS plastic

Dimensional drawings

Compact version See dimensional drawings

19“ insert See dimensional drawings

Weight

Compact version 0.75 kg (2 lb)

19“ insert See dimensional drawings

Power supply • 115 ... 230 V AC +10% -15%, 50 ... 60 Hz, 17 VA

• 11 ... 30 V DC or 11 ... 24 V AC

Power consumption • 230 V AC: 17 VA• 24 V AC : 9 W, IN = 380 mA,

IST = 8 A (30 ms)• 12 V DC : 11 W, IN = 920 mA,

IST = 4 A (250 ms)

Certificates and approvals CE, ULc general purpose, C-tick; FM/CSA Class 1, div 2

Custody transfer approval (MAG 5000/6000 CT)

• PTB OIML R49 (cold water); MI-001

• PTB and DANAK OIML R75 (hot water)

• PTB and DANAK OIML R117 (cold water/milk, beer etc.)

Communication

Standard

• MAG 5000 Without serial communication or HART as option

• MAG 6000 Prepared for client mounted add-on modules

Optional (MAG 6000 only) HART, MODBUS RTU/RS485, PROFIBUS PA, PROFIBUS DP as add-on modules

• MAG 5000/6000 CT no communication moduls approved

© Siemens AG 2007

Page 3: SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F flowmeters SITRANS F M ... the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F,

SITRANS F flowmetersSITRANS F M

Transmitter MAGFLO MAG 5000/6000

4/28 Siemens FI 01 · 2008

4

Safety barrier (e/ia)

Electrode cleaning unit

Cleaning unit

The Siemens cleaning unit can be used with MAG 5000 or 6000 in 19” insert version.The cleaning unit can be used in applications where the liner and subsequently the electrodes may be coated with deposits. If the coating is electrically insulating, the electrode signal will be reduced. If the coating is electrically inductive, the electrode sig-nal will be partly short-circuited and in both cases the accuracy of the meter will decrease (dependent on coating type and thick-ness).

Note:

The cleaning unit cannot be used for inflammable or explosive media!

Application For use with MAG 5000/6000 19” and MAG 1100 Ex ATEX/MAG 3100 Ex ATEX

Ex approval MAG 1100 Ex [EEx e ia] IIB ATEX

MAG 3100 Ex [EEx e ia] IIC ATEX

Cable parameter• Electrode

Group Capacity in µF Inductance in mH

IIC ≤ 4.1 ≤ 80

IIB ≤ 45 ≤ 87

IIA ≤ 45 ≤ 87

Ambient temperature

• During operation -20 ... +50 °C (-4 ... +122 °F)

• During storage -20 ... +70 °C (-4 ... +158 °F)

Enclosure

• Material Standard 19” insert in aluminium/steel (DIN 41494)

• Width 21 TE (4.75”)

• Height 3 HE (5.25”)

• Rating IP20 / NEMA 2 to EN 60529 and DIN 40050

• Mechanical load 1 g, 1 … 800 Hz sinusoidal in all directions to EN 60068-2-36

EMC performance

• Emission EN 50081-1 (Light industry)

• Immunity EN 50082-2 (Industry)

Application For use with transmitters MAG 5000 and 6000 19” to clean the electrodes on sensors MAG 1100 or MAG 3100

NB: Must not be used with intrinsically safe ATEX sensorsNB: Not to be used with sensors with Hastelloy and Tantalum electrodes

Cleaning voltage

AC cleaning 60 V AC

DC cleaning 30 V DC

Cleaning period 60 s + 60 s pause period

Relay

• Load 42 V/2 A

Operation Switch relay activated when cleaning is in progress

• Automatic Yes

• Manual No

Indicator lamps LEDs: “ON” and “CLEANING”

Supply voltage and power consumption

115 … 230 V AC, +10% … -15%, 50 … 60 Hz, 7 VA cleaning, 5 VA stand by11 … 30 V DC / 11 … 24 V AC, 50 … 60 Hz, 7 VA cleaning, 5 VA stand by

Ambient temperature

• During operation -20 ... +50 °C (-4 ... +122 °F)

• During storage -20 ... +70 °C (-4 ... +158 °F)

Enclosure

• Material Standard 19” insert in aluminium/steel (DIN 41494)

• Width 21 TE (4.75”)

• Height 3 HE (5.25”)

• Rating IP20 / NEMA 2 to EN 60529 and DIN 40050

• Mechanical load 1 g, 1 … 800 Hz sinusoidal in all directions to EN 60068-2-36

© Siemens AG 2007

Page 4: SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F flowmeters SITRANS F M ... the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F,

SITRANS F flowmetersSITRANS F M

Transmitter MAGFLO MAG 5000/6000

4/29Siemens FI 01 · 2008

4

Mode of operation

The cleaning unit cleans the electrodes electro-chemically by applying a voltage to the electrodes for approx. 60 seconds. While cleaning, the transmitter stores and holds the latest mea-sured flow reading on the display and also the signal outputs. Af-ter an additional pausing period of 60 seconds the flowmeter re-sumes normal measurement and the cleaning is now completed.

The relay in the transmitter activates the cleaning cycle. In the re-lay output menu (under cleaning) the cleaning interval can be set between 1 hour and 24 hours.

Cleaning should only take place with liquid in the pipe.This can be detected via the empty pipe function. It is therefore recom-mended to select “empty pipe detection” ON when using the cleaning.

The cleaning sequence can also be controlled manually through the electrical input of the transmitter. Before this is done, ensure that the measuring pipe is full.

AC cleaning

AC-cleaning is used to remove fatty deposits on the electrodes. These fatty deposits are seen in waste water applications, in ab-attoirs and water applications with oil residuals. During the cleaning process, the surface of the electrodes get warmer, which tends to soften grease particles and the gas bubbles gen-erated mechanically lift deposits away from the surface of the electrodes.

DC cleaning

DC-cleaning is used to eliminate electrically conductive depos-its in the measuring pipe influencing the measuring accuracy.

Particularly in district heating applications an electrically con-ductive deposit (magnetite) may occur and short-circuit the electrode signal. In this case the accuracy of the meter de-creases and the signal/noise conditions of the meter become in-ferior. The problem only arises if the conductivity of the water is less than approx. 250 µS/cm.

During DC-cleaning electrolysis takes place where the flow of electrons removes the particle deposits from the electrode area.

Note:

Do not use DC-cleaning on sensors with Tantalum or Hastelloy electrodes.

© Siemens AG 2007

Page 5: SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F flowmeters SITRANS F M ... the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F,

SITRANS F flowmetersSITRANS F M

Transmitter MAGFLO MAG 5000/6000

4/30 Siemens FI 01 · 2008

4

Selection and Ordering DataTransmitter MAG 5000

Transmitter MAG 6000

Description Order No.F) Symbol

Transmitter MAG 5000 Blindfor compact and wall mount-ing; IP67/NEMA 4X, fibre-glass reinforced polyamide

• 11 ... 30 V DC / 11 ... 24 V AC

7ME6910-1AA30-0AA0

• 115/230 V AC, 50/60 Hz 7ME6910-1AA10-0AA0

Transmitter MAG 5000 Dis-play for compact and wall mounting;IP67/NEMA 4X, fibre-glass reinforced polyamide

• 11 ... 30 V DC / 11 ... 24 V AC

7ME6910-1AA30-1AA0

• 115/230 V AC, 50/60 Hz 7ME6910-1AA10-1AA0

• 115/230 V AC, 50/60 Hz, with HART

7ME6910-1AA10-1BA0

Transmitter MAG 5000 CTfor compact and wall mount-ing, approved for custody transfer;IP67/NEMA 4X, fibre-glass reinforced polyamide

• 11 ... 30 V DC / 11 ... 24 V AC

7ME6910-1AA30-1AB0

• 115/230 V AC, 50/60 Hz 7ME6910-1AA10-1AB0

Transmitter MAG 5000 for 19” rack and wall mount-ing

• 11 ... 30 V DC / 11 ... 24 V AC

7ME6910-2CA30-1AA0

• 115/230 V AC, 50/60 Hz 7ME6910-2CA10-1AA0

Description Order No.F) Symbol

Transmitter MAG 6000 Blindfor compact and wall mount-ing;IP67/NEMA 4X, fibre-glass reinforced polyamide

• 11 ... 30 V DC / 11 ... 24 V AC

7ME6920-1AA30-0AA0

• 115/230 V AC, 50/60 Hz 7ME6920-1AA10-0AA0

Transmitter MAG 6000 for compact and wall mount-ing;

IP67/NEMA 4X, fibre-glass reinforced polyamide

• 11 ... 30 V DC / 11 ... 24 V AC

7ME6920-1AA30-1AA0

• 115/230 V AC, 50/60 Hz 7ME6920-1AA10-1AA0

IP67/NEMA 4X, AISI 316 stainless steel (only for sen-sor with SS terminal box )

• 11 ... 30 V DC / 11 ... 24 V AC

7ME6920-1QA30-1AA0

• 115/230 V AC, 50/60 Hz 7ME6920-1QA10-1AA0

Available ex stock

Transmitter MAG 6000 CTfor compact and wall mount-ing, approved for custody transfer (no communication moduls possible); IP67/NEMA 4X, fibre-glass reinforced polyamide

• 11 ... 30 V DC / 11 ... 24 V AC

7ME6920-1AA30-1AB0

• 115/230 V AC, 50/60 Hz 7ME6920-1AA10-1AB0

Transmitter MAG 6000 SVfor compact and wall mount-ing; special excitation 44 Hz settings for Batch applica-tion DN ≤ 25/1“IP67/NEMA 4X, fibre-glass reinforced polyamide

11 ... 30 V DC / 11 ... 24 V AC

7ME6920-1AB30-1AA0

115/230 V AC, 50/60 Hz 7ME6920-1AB10-1AA0

Transmitter MAG 6000 for 19“ rack and wall mounting

• 11 ... 30 V DC / 11 ... 24 V AC

7ME6920-2CA30-1AA0

• 115/230 V AC, 50/60 Hz 7ME6920-2CA10-1AA0

Transmitter MAG 6000 SVfor 19“ rack and wall mount-ing; special excitation 44 Hz settings for Batch applica-tion DN ≤ 25/1“

• 11 ... 30 V DC / 11 ... 24 V AC

7ME6920-2CB30-1AA0

• 115/230 V AC, 50/60 Hz 7ME6920-2CB10-1AA0

MAG 6000 with IP66/NEMA 4X enclosure;115/230 V AC, 50/60 Hz

7ME6920-2EA10-1AA0

MAG 6000 with electrode cleaning unit, complete mounted with IP66/NEMA 4X mounting enclosure

• 11 ... 30 V DC / 11 ... 24 V AC

7ME6920-2PA30-1AA0

• 115/230 V AC, 50/60 Hz 7ME6920-2PA10-1AA0

MAG 6000 with safety bar-rier for ATEX 2G D approved sensors, complete mounted with IP66/NEMA 4X wall mounting enclosure, ATEX,115/230 V AC, 50/60 Hz

• For ATEX 2G D sensors 7ME6920-2MA11-1AA0

MAG 6000 SV, 19” insert, in IP66/NEMA 4X , ABS plas-tic enclosure, excitation fre-quency 44 Hz for Batch application DN ≤ 25/1“,11 … 30 V DC, 11 … 24 V AC, 50/60 Hz

7ME6920-2EB30-1AA0

Description Order No.F) Symbol

F) All products on this page subject to export regulations AL: 9I999, ECCN: N.

© Siemens AG 2007

Page 6: SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F flowmeters SITRANS F M ... the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F,

SITRANS F flowmetersSITRANS F M

Transmitter MAGFLO MAG 5000/6000

4/31Siemens FI 01 · 2008

4

Communication modules for MAG 6000

Accessories for MAG 5000 and MAG 6000

Description Order No.F) Symbol

HART (not for MAG 6000 I)

FDK-085U0226

MODBUS RTU/RS485 FDK-085U0234

PROFIBUS PA Profile 3 FDK-085U0236

PROFIBUS DP Profile 3 FDK-085U0237

Description Order No.F) Symbol

Wall mounting unit for IP67/NEMA 4X version, wall bracket, terminal box in polyamide

• 4 x M20 cable glands FDK-085U1018

• 4 x ½“ NPT cable glands FDK-085U1053

Cable for standard elec-trode or coil, 3 x 1.5 mm² / 18 gage with shield PVC

• 10 m (33 ft) FDK-083F0121

• 20 m (65 ft) FDK-083F0210

• 40 m (130 ft) FDK-083F0211

• 60 m (200 ft) FDK-083F0212

• 100 m (330 ft) FDK-083F0213

• 150 m (500 ft) FDK-083F3052

• 200 m (650 ft) FDK-083F3053

• 500 m (1650 ft) FDK-083F3054

Electrode cable for empty pipe or low conductivity, double shielded, 3 x 0.25 mm²

• 10 m (33 ft) FDK-083F3020

• 20 m (65 ft) FDK-083F3095

• 40 m (130 ft) FDK-083F3094

• 60 m (200 ft) FDK-083F3093

• 100 m (330 ft) FDK-083F3092

• 150 m (500 ft) FDK-083F3056

• 200 m (650 ft) FDK-083F3057

• 500 m (1650 ft) FDK-083F3058

Cable kit with standard coil cable, 3 x 1.5 mm²/18 gage with shield PVC and elec-trode cable double shielded, 3 x 0.25 mm²

• 10 m (33 ft) A5E01181647

• 20 m (65 ft) A5E01181656

• 40 m (130 ft) A5E01181686

• 60 m (200 ft) A5E01181689

• 100 m (330 ft) A5E01181691

• 150 m (500 ft) A5E01181699

• 200 m (650 ft) A5E01181703

• 500 m (1640 ft) A5E01181705

Cable glands, for above cable, 2 pcs.

• M20 A5E00822490

• ½“ NPT A5E00822501M20½“ NPT

Sealing screws for sensor/ transmitter, 2 pcs

FDK-085U0221

Terminal box, in polyamide, inclusive lid

• M20 FDK-085U1050

• ½" NPT FDK-085U1052

Terminal box lid, in polyamid FDK-085U1003

Terminal box for MAG 6000, in stainless steel, inclusive lid

• M20 A5E00836867

• ½" NPT A5E00836868

Terminal box (3A) for MAG 1100 Food in polya-mide, inclusive lid

• M20 A5E00822478

• ½" NPT A5E00822479

Potting kit for terminal box of MAG sensors for IP68/NEMA 6P

FDK-085U0220

19“ cleaning unit for elec-trode cleaning (21TE) incl. back plate

• 11 ... 30 V DC / 11 ... 24 V AC

FDK-083F5039

• 115 ... 230 V AC, 50/60 Hz FDK-083F5036

19“ safety barrier (21 TE) [EEx e ia] IIC for MAG 1100 ATEX and MAG 3100 ATEX, incl. back plate

FDK-083F5034

Panel mounting enclosure for 19“ insert (21 TE); IP65/NEMA 4 enclosure in ABS plastic for front panel mounting

FDK-083F5030

Panel mounting enclosure for 19“ insert (42 TE); IP65/NEMA 4 enclosure in ABS plastic for front panel mounting

FDK-083F5031

Back of panel mounting enclosure for 19“ insert (21 TE); IP20/NEMA 2 enclo-sure in aluminium

FDK-083F5032

Back of panel mounting enclosure for 19“ insert (42 TE); IP20/NEMA 2 enclo-sure in aluminium

FDK-083F5033

Available ex stock

Description Order No.F) Symbol

F) All products on this page subject to export regulations AL: 9I999, ECCN: N.

© Siemens AG 2007

Page 7: SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F flowmeters SITRANS F M ... the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F,

SITRANS F flowmetersSITRANS F M

Transmitter MAGFLO MAG 5000/6000

4/32 Siemens FI 01 · 2008

4

Back plates (if wall enclosure IP66 is used as part)

Spare parts

Sun Shields for MAG 5000/6000 transmitters

IP66/NEMA 4, wall mounting enclosure for 19“ inserts(without backplates)

• 21 TE FDK-083F5037

• 42 TE FDK-083F5038

Front cover (7TE) FDK-083F4525

Available ex stock

Description Order No.F) Symbol

Wall unit enclosure IP66, 12 ... 24 V, 115 ... 230 V

• Transmitter FDK-083F4121

• Transmitter ia/e and safety barrier

FDK-083F4122

• Transmitter ia/ib and safety barrier (only for sensors produced before October 2007)

FDK-083F4120

• Transmitter and cleaning unit

FDK-083F4124

Description Order No.F) SymbolDescription Order No.F) Symbol

Connection plate

• 12 ... 24 V FDK-083F4149

• 115 ... 230 V FDK-083F4148

19“ enclosure, 12 ... 24 V, 115 ... 230 V

• Transmitter FDK-083F4117

• Transmitter ia and safety barrier

FDK-083F4118

• Transmitter ia/ib and safety barrier (only for sensors produced before October 2007)

FDK-083F4119

• Transmitter and cleaning unit

FDK-083F4123

SENSORPROM memory unit(Sensor code and serial numbers must be specified on order)

• 2 kB (for MAG 5000/6000/ MAG 6000 I)

FDK-085U1005

• 250 B (for MAG 2500/3000)

FDK-085U1008

Display unit for MAG 5000/6000

• black neutral front FDK-085U1038

• Siemens front FDK-085U1039

Description Order No.F) Symbol

Sun shield for remote MAG 5000/6000 transmit-ters

A5E01209496

Sun Shield for compact MAG 5000/6000 transmit-ters on MAG 3100 (DN 15 ... 2000 (½" ... 78") or MAG 5100 (DN 150 ... 1200 (6" ... 48")

A5E01209500

F) All products on this page subject to export regulations AL: 9I999, ECCN: N.

© Siemens AG 2007

Page 8: SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F flowmeters SITRANS F M ... the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F,

SITRANS F flowmetersSITRANS F M

Transmitter MAGFLO MAG 5000/6000

4/33Siemens FI 01 · 2008

4

Dimensional drawings

Transmitter IP67/NEMA 4X compact polyamide

Transmitter compact mountedTransmitter wall mounted

Transmitter, 19” IP20/ NEMA 2 standard unit

155 (6.10)6 (0.24)

131 (5.16)

128

(7.1

6)

© Siemens AG 2007

Page 9: SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F flowmeters SITRANS F M ... the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F,

SITRANS F flowmetersSITRANS F M

Transmitter MAGFLO MAG 5000/6000

4/34 Siemens FI 01 · 2008

4

Transmitter, wall mounting IP66/NEMA 4, 21 TE

Transmitter, wall mounting IP66/NEMA 4, 42 TE

© Siemens AG 2007

Page 10: SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F flowmeters SITRANS F M ... the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F,

SITRANS F flowmetersSITRANS F M

Transmitter MAGFLO MAG 5000/6000

4/35Siemens FI 01 · 2008

4

Transmitter, panel front IP65/NEMA 4, 21 TE

Transmitter, panel front IP65/NEMA 4, 42 TE

© Siemens AG 2007

Page 11: SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F flowmeters SITRANS F M ... the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F,

SITRANS F flowmetersSITRANS F M

Transmitter MAGFLO MAG 5000/6000

4/36 Siemens FI 01 · 2008

4

Transmitter, back of panel IP20/NEMA 2, 21 TE

Transmitter, back of panel IP20/NEMA 2, 42 TE

© Siemens AG 2007

Page 12: SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F flowmeters SITRANS F M ... the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F,

SITRANS F flowmetersSITRANS F M

Transmitter MAGFLO MAG 5000/6000

4/37Siemens FI 01 · 2008

4

Schematics

Electrical connection

Grounding

PE must be connected due to safety class 1 power supply.

Mechanical counters

When mounting a mechanical counter to terminals 57 and 58 (active output), a 1000 µF capacitor must be connected to the terminals 56 and 58. Capacitor + is connected to terminal 56 and capacitor - to terminal 58.

Output cables

If the output cable length is long in noisy environment, we recommend to use screened cable.

1)

1) Note Special cable with individual wire shields (shown as dotted lines) are only required when using empty pipe function or long cables

Shield

© Siemens AG 2007

Page 13: SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F flowmeters SITRANS F M ... the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F,

SITRANS F flowmetersSITRANS F MTransmitterMAGFLO MAG 6000 I/6000 I Ex d

4/38 Siemens FI 01 · 2008

4

Overview

The SITRANS F M MAGFLO MAG 6000 I/I Ex d transmitter is de-signed for the demands in the process industry. The robust die cast aluminium housing provides superb protection, even in the most harsh industrial environments. Full input and output func-tionality is given even in the Ex version.

Benefits

• Full range of ATEX rated flowmeters with intrinsically safe rated input and outputs

• For compact or remote installation• HART, PROFIBUS PA/DP, MODBUS RTU/RS485 add-on com-

munication modules available• Superior signal resolution for optimum turn down ratio• Digital signal processing with many possibilities• Automatic reading of SENSORPROM data for easy commis-

sioning• User configurable operation menu with password protection

- 3 lines, 20 characters display in 11 languages- Flow rate in various units- Totalizer for forward, reverse and net flow as well as much

more information available.• Multiple functional outputs for process control, minimum con-

figuration with analogue, pulse/frequency and relay output (status, flow direction, limits)

• Comprehensive self-diagnostic for error indication and error logging

• Batch control

Design

The transmitter is designed for either compact or remote instal-lation in non-hazardous or hazardous areas (compact mounted transmitter to be ordered together with the sensors).

Function

The following functions are available:• Flow rate• 2 measuring ranges• 2 totalizers• Low flow cut-off• Flow direction• Error system• Operating time• Uni-/bidirectional flow• Limit switches and pulse output• Batch control

The MAG 6000 I/6000 I Ex d is a microprocessor-based trans-mitter with a build-in alphanumeric display in several languages. The transmitters evaluate the signals from the associated elec-tromagnetic sensors and also fulfil the task of a power supply unit which provides the magnet coils with a constant current.

Further information on connection, mode of operation and instal-lation can be found in the data sheets for the sensors.

Displays and keypads

Operation of the transmitter can be carried out using:• Keypad and display unit• HART communicator• PC/laptop and SIMATIC PDM software via HART communica-

tion• PC/laptop and SIMATIC PDM software using PROFIBUS or

MODBUS communication

Technical specifications

Mode of operation and design

Measuring principle Electromagnetic with pulsed con-stant field

Empty pipe Detection of empty pipe (special cable required in remote mounted installation)

Excitation frequency Depend on sensor size

Electrode input impedance > 1 x 1014 Ω

Input

Digital input DC 11 ... 30 V, Ri = 4.4 kΩ

• Activation time 50 ms

• Current IDC 11 V = 2.5 mA, IDC 30 V = 7 mA

Output

Current output

• Signal range 0 ... 20 mA or 4 ... 20 mA (active/ passive)

• Load < 560 Ω

• Time constant 0.1 … 30 s, adjustable

Digital output

Frequency 0 … 10 kHz, 50% duty cycle (uni-/bidirectional)

Time constant 0.1 … 30 s, adjustable

Pulse (passive) 3 … 30 V DC, max 110 mA (30 mA Ex version), 200 Ω ≤ Ri ≤ 10 kΩ (powered from connected equipment)

Time constant 0.1 … 30 s, adjustable

Relay output

Time constant Changeover relay, same as cur-rent output

Load 42 V AC/2 A, 24 V DC/1 A

Low flow cut off 0 … 9.9% of maximum flow

Galvanic isolation All inputs and outputs are galvanic isolated

Max. measuring error

MAG 6000 I/MAG 6000 I Ex d 0.25% of rate

© Siemens AG 2007

Page 14: SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F flowmeters SITRANS F M ... the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F,

SITRANS F flowmetersSITRANS F M

TransmitterMAGFLO MAG 6000 I/6000 I Ex d

4/39Siemens FI 01 · 2008

4

Technical specifications (continued)

Communication modules for MAG 6000 I (All standard outputs can still be used)

Rated operation conditions

Ambient temperature

• Operation

- MAG 6000 I -20 … +60 °C (-4 … +140 °F)

- MAG 6000 I Ex -10 … +60 °C (+14 … +140 °F)

• Storage -40 … +70 °C (-40 … +158 °F)

Mechanical load 18 ... 1000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36Transmitter: 1.14 grms

Degree of protection IP67/NEMA 4X to IEC 529 and DIN 40050 (1 mH2O 30 min.)

EMC performance EN 61326

Display and keypad

Totalizer Two eight-digit counters for for-ward, net or reverse flow

Display Background illumination with alphanumeric text, 3 x 20 charac-ters to indicate flow rate, totalized values, settings and faults; Reverse flow indicated by nega-tive sign

Keypad Capacitive touch keypad with LED light for feedback indication

Time constant Time constant as current output time constant

Design

Enclosure material Die cast aluminium, painted

• Wall mounting Wall mounting bracket enclosed for remote version

Dimensional drawings See dimensional drawings

Weight See dimensional drawings

Power supply • Non Ex d: 18 ... 90 V DC; 115 ... 230 V AC; 50 ... 60 Hz

• Ex d: 18 ... 30 V DC• Ex d: 115 ... 230 V AC;

50 ... 60 Hz

Power consumption • 230 V AC: 21.5 VA• 24 V DC: 12 W, IN = 380 mA,

IST = 1 A (3 ms)

Certificates and approvals

MAG 6000 I • CE• C-tick• FM Class 1, div 2• FM Class 1, Zone 2• CSA Class 1, div 2• CSA Class 1, Zone 2

MAG 6000 I Ex (to be used with ATEX 2G D sensors)

• SIRA 03 ATEX 2072X• EX II 2 (1) (2) G D • EEx d e [ia] ia [ib] ib IIC, T6

Cable entries Remote installation• MAG 6000 I: 2 x M25(for sup-

ply/output) and 2 x M16 (for sen-sor connection) or 2 x ½" NPT (for supply/output) and 2 x M16 (for sensor connection)

• MAG 6000 I Ex ATEX 2G D: 2 x M20 (for supply/output) and 2 x M16 (for sensor connection)

Communication

Non ATEX versions HART, MODBUS RTU/RS 485, PROFIBUS PA, PROFIBUS DP add-on modules

ATEX 2G D HART, PROFIBUS PA available as integrated version

Selection and Ordering data Order-No.

SITRANS F M TransmitterMAGFLO MAG 6000 I / Ex dRemote, local display, die cast aluminium

F) 7ME6930-

2 B A77 - 1 7 A 7

Supply voltage115 ... 230 V AC, 50 ... 60 Hz; 18 ... 90 V DC 2ATEX 2G D, 18 ... 30 V DC 4ATEX 2G D, 115 ... 230 V AC, 50 ... 60 Hz 5

Ex approval

None ATEX; FM/CSA class1 div 2 0ATEX 2G D 2

Communication

None (add-on modules can be ordered separately, see below)

A

HART BPROFIBUS PA Profile 3 FPROFIBUS DP Profile 3 (not Ex version) GMODBUS RTU/RS 485 (not Ex version) E

Cable gland entries

Metric 0½" NPT 2

Description Order No. Symbol

HART (only for MAG 6000 I/Ex)

F) FDK-085U0321

MODBUS RTU/RS485 F) FDK-085U0234

PROFIBUS PA Profile 3 F) FDK-085U0236

PROFIBUS DP Profile 3 F) FDK-085U0237

F) Subject to export regulations AL: 9I999, ECCN: N.

© Siemens AG 2007

Page 15: SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F flowmeters SITRANS F M ... the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F,

SITRANS F flowmetersSITRANS F MTransmitterMAGFLO MAG 6000 I/6000 I Ex d

4/40 Siemens FI 01 · 2008

4

Accessories MAG 6000 I

Spare parts

Complete spare part PCB unit

Please use online Product selector to get latest updates.

Product selector link:www.pia-selector.com/its_main_en.asp

Please also see www.siemens.com/SITRANSForderingfor practical examples of ordering

Dimensional drawings

Dimensions in mm (inch), weight: 6 kg (13.5 lbs)

Description Order No.F) Symbol

Cable for standard elec-trode or coil, 3 x 1.5 mm²/18 gage with shield PVC

• 10 m (33 ft) FDK-083F0121

• 20 m (65 ft) FDK-083F0210

• 40 m (130 ft) FDK-083F0211

• 60 m (200 ft) FDK-083F0212

• 100 m (330 ft) FDK-083F0213

• 150 m (500 ft) FDK-083F3052

• 200 m (650 ft) FDK-083F3053

• 500 m (1650 ft) FDK-083F3054

Electrode cable for empty pipe or low conductivity, double shielded, 3 x 0.25 mm² (cannot be used for Ex applications)

• 10 m (33 ft) FDK-083F3020

• 20 m (65 ft) FDK-083F3095

• 40 m (130 ft) FDK-083F3094

• 60 m (200 ft) FDK-083F3093

• 100 m (330 ft) FDK-083F3092

• 150 m (500 ft) FDK-083F3056

• 200 m (650 ft) FDK-083F3057

• 500 m (1650 ft) FDK-083F3058

Cable kit with standard coil cable, 3 x 1.5 mm²/18 gage with shield PVC and elec-trode cable double shielded, 3 x 0.25 mm²

• 10 m (33 ft) A5E01181647

• 20 m (65 ft) A5E01181656

• 40 m (130 ft) A5E01181686

• 60 m (200 ft) A5E01181689

• 100 m (330 ft) A5E01181691

• 150 m (500 ft) A5E01181699

• 200 m (650 ft) A5E01181703

• 500 m (1640 ft) A5E01181705

Available ex stock

Description Order No.F) Symbol

Display FDK-085U3122

Accessory bag including cable gland inserts coil & elec-trode connectors

FDK-085U3144

Electronics cover with glas-plate Non Ex

7ME5933-0AC01

Cover for connection board incl. gasket

7ME5933-0AC02

Cover for connection board incl. gasket

7ME5933-0AC03

Safety clamp 7ME5933-0AC06

Description Order No.F) Symbol

Not Ex FDK-085U3123

MAG 6000 I Ex d 18 ... 30 V DC Spare PCB unit for use with ATEX sensors with increased safety e

A5E01013340

MAG 6000 I Ex d 115 ... 230 V AC Spare PCB unit for use with ATEX sensors with increased safety e

A5E01013127

Ex d version 18 ... 30 V DCfor sensors with intrinsic safety ib 7ME633 and 7ME613≤ DN 300 (12")

FDK-085U3124

Ex d version 115 ... 230 V AC for sensors with intrinsic safety ib 7ME633 and 7ME613 ≤ DN 300 (12")

FDK-085U3125

153 (6.08)205 (8.07)

248

(9.7

6)

Ø 80 (3.15)

100 (3.94)

250

(9.8

4)

220

(8.6

6)

98.5 (3.88)33.5 (1.32)

F) All products on this page subject to export regulations AL: 9I999, ECCN: N.

© Siemens AG 2007

Page 16: SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F flowmeters SITRANS F M ... the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F,

SITRANS F flowmetersSITRANS F M

TransmitterMAGFLO MAG 6000 I/6000 I Ex d

4/41Siemens FI 01 · 2008

4

Schematics

Ω

Ω

© Siemens AG 2007

Page 17: SITRANS F flowmeters SITRANS F Mliterature.puertoricosupplier.com/017/JI17251.pdf · SITRANS F flowmeters SITRANS F M ... the SITRANS F M MAGFLO sensors type MAG 1100, MAG 1100 F,

SITRANS F flowmetersSITRANS F M

MAGFLO MAG 1100

4/42 Siemens FI 01 · 2008

4

Overview

The SITRANS F M MAGFLO MAG 1100 is an electromagnetic flow sensor in a compact wafer design designed for flow appli-cations in the process industry.

Benefits

• Sensor sizes: DN 2 to 100 (1/12” to 4”)• Compact wafer design meets EN 1092, DIN and ANSI flange

standards• Corrosion resistant AISI 316 stainless steel sensor housing• Highly resistant liner and electrodes fitting most extreme pro-

cess media• Temperature rating up to 200 °C (390 °F)• Hose proof IP67/NEMA 4X/6 enclosure rating• Designed that patented in-situ verification can be conducted.

Using SENSORPROM fingerprints.

Application

The main applications of the SITRANS F M MAGFLO electro-magnetic flow sensors can be found in the following fields:• Process industry• Chemical industry• Pharmaceutical industry• Water treatment like e.g. chemical dosing

Design

• Compact or remote mounting possible• Easy "plug & play" field changeability of transmitter• Simple on site upgrade to IP68/NEMA 6P• Ex ATEX 2G D version• FM/CSA Class 1 Div 2

Mode of operation

The flow measuring principle is based on Faraday’s law of elec-tromagnetic induction were the sensor converts the flow into an electrical voltage proportional to the velocity of the flow.

Integration

The complete flowmeter consists of a flow sensor and an asso-ciated transmitter SITRANS F M MAGFLO MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies in-tegration and update to a variety of fieldbus systems such as HART, PROFIBUS DP & PA, MODBUS RTU/RS 485.

© Siemens AG 2007