SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1...

23
Protocol Date: Version: 2 Protocol Author: MCERTS Number: MCERTS Level: Technical Endorsements: Protocol Approved By: MCERTS Number: Business Title: Technical Endorsements: Signature: Name of Client Client Approval Granted Approval Date David Hay MM 04 552 MCERTS Level 2 - Business Manager TE1, TE2, TE3 & TE4 SSP Approval Andrew O'Meara Yes / No TE1, TE2, TE3 & TE4 Installation: Clonmel Sampling Date(s) 18-20 Feb 2020 Permit Reference: IPPC Licence: P0027-04 LEK 12100 14 February 2020 Enda Flood MM12 1170 MCERTS Level 2 - Team Leader SOCOTEC UK Job Number Medite Europe Limited Tel: 01355 246 730 Fax: 01355 249 669 Your Contact at SOCOTEC UK LTD David Hay Business Manager - North Tel: 01355 246 730 Email: [email protected] Commissioned by: Medite Europe Limited Operator / Company: G75 0YF SITE SPECIFIC PROTOCOL (SSP) Prepared by SOCOTEC UK LTD 2-4 Langlands Place Kelvin South Business Park East Kilbride SOCOTEC UK SSP Template v2 For inspection purposes only. Consent of copyright owner required for any other use. EPA Export 27-05-2020:04:00:40

Transcript of SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1...

Page 1: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

Protocol Date:Version: 2Protocol Author:MCERTS Number:MCERTS Level:Technical Endorsements:Protocol Approved By:MCERTS Number:Business Title:Technical Endorsements:Signature:

Name of ClientClient Approval GrantedApproval Date

David HayMM 04 552MCERTS Level 2 - Business ManagerTE1, TE2, TE3 & TE4

SSP ApprovalAndrew O'Meara

Yes / No

TE1, TE2, TE3 & TE4

Installation:Clonmel

Sampling Date(s)18-20 Feb 2020

Permit Reference:IPPC Licence: P0027-04

LEK 1210014 February 2020

Enda FloodMM12 1170MCERTS Level 2 - Team Leader

SOCOTEC UK Job Number

Medite Europe Limited

Tel: 01355 246 730Fax: 01355 249 669

Your Contact at SOCOTEC UK LTDDavid Hay

Business Manager - NorthTel: 01355 246 730

Email: [email protected]

Commissioned by:Medite Europe Limited

Operator / Company:

G75 0YF

SITE SPECIFIC PROTOCOL (SSP)

Prepared by SOCOTEC UK LTD2-4 Langlands Place

Kelvin South Business ParkEast Kilbride

SOCOTEC UK SSP Template v2

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:00:40

Page 2: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

Commissioned by:Operator Name:Operator Address: Medite Europe Limited

Redmonstown,Clonmel,Co. Tipperary,Ireland

IPPC Licence

DetailsContact NamePositionTelephone NumberFax NumberEmail Address

Historical InformationDate of Previous Sampling Campaign 20-23 Nov-2019

Current InformationJob Number LEK 12100Sampling Dates 18-20 Feb 2020Expected Number of Days on Site 3

Monitoring OrganisationSOCOTEC UK2-4 Langlands PlaceKelvin South Business ParkEast KilbrideG75 0YF

Level Expiry TE1 TE2 TE3 TE4 H&SEnda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun 2023 Nov 2023 Apr 2023Daniel Sculy MM19 1563 MCERTS Trainee Oct 2024 - - - - Oct 2024

The appointed project manager is Enda Flood

Job Number of Previous Sampling Campaign LEK 11974

MONITORING TEAM

Personnel MCERTS Number MCERTS Qualification TE / H&S Qualifications and Expiry Date

+353 (0) 87 [email protected]

Main Contact Secondary ContactAndrew O'MearaEHS Manager

SOCOTEC UK were commissioned by Medite Europe Limited to carry out a stack emissions monitoring campaign, to perform compliance monitoring on the following plant(s).

Operator DetailsMedite Europe LimitedMedite Europe Limited

P0027-04

Medite Europe Limited operates a prescribed process in Clonmel which is subject to a IPPC Licence under the EPA Act 1992.

Site Specific Protocol (SSP) - Part 1

To comply with the requirements of the Environment Agency's MCERTS Performance Standard, UKAS accredited emissions monitoring organisations are required to submit to theOperator a Site Specific Protocol (SSP). The SSP is an installation specific measurement plan which details the sampling methods and technical procedures that apply to theproposed emission monitoring. Where applicable the SSP will be updated to include any feedback that is gathered during the sitework.

2 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:00:40

Page 3: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

Overall Aim:

P P P P P P P P O O

20 20 20 15 15 15 15 15 - -EN 13284-1 EN 13284-1 EN 13284-1 BS EN 13284-1 BS EN 13284-1 BS EN 13284-1 BS EN 13284-1 BS EN 13284-1 - -

P P P O O O P P O O

0.6 0.06 0.06 - - - 0.06 0.06 - -CTM 036 CTM 036 CTM 036 - - - CTM 036 CTM 036 - -

P P P P P P P P O O

15 15 15 10 6 6 5 5 - -US EPA M316 US EPA M316 US EPA M316 US EPA M316 US EPA M316 US EPA M316 US EPA M316 US EPA M316 - -

P P P P P P P P O O

120 120 120 20 100 100 100 100 - - EN 12619:2013 EN 12619:2013 EN 12619:2013 EN 12619:2013 EN 12619:2013 EN 12619:2013 EN 12619:2013 EN 12619:2013 - -

P P P P O O O O O O

110 110 110 100 - - - - - -EN 14792 EN 14792 EN 14792 EN 14792 - - - - - -

P P P P O O O O O O

300 600 600 100 - - - - - -EN 15058 EN 15058 EN 15058 EN 15058 - - - - - -

P P P P P P P P O O

EN 14790 EN 14790 EN 14790 EN 14790 EN 14790 EN 14790 EN 14790 EN 14790 - -

P P P P P P P P O O

EN 16911-1 EN 16911-1 EN 16911-1 EN 16911-1 EN 16911-1 EN 16911-1 EN 16911-1 EN 16911-1 - -

SSP Part 2 - Monitoring Objectives

Velocity & Temperature TraverseMethod

MoistureMethod

Carbon Monoxide

Limit (mg/m³)Method

Limit (mg/m³)Method

Oxides of Nitrogen

Limit (mg/m³)Method

VOCs

FormaldehydeLimit (mg/m³)Method

Compliance Monitoring

Isocyanates

Limit (mg/m³)Method

Limit (mg/m³)Method

-

Reference Conditions STP, dry gas STP, dry gas STP, dry gas STP, dry gas STP, dry gas STP, dry gas STP, Wet STP, dry gas

A2-21 EP 9 (Cyclone Line 2)

Drier Stage 1

A2-5 EP 34 (Cyclone Line 1)

Core Dryer

A2-6 EP 35 (Cyclone Line 1)

Face Dryer

A2-15 EP 25 (Press Fan) Drier

Stage 1

A2-22 EP 5 (Press Fan) Vent

1 Line 2

A2-23 EP 6 (Press Fan) Vent

2 Line 2

A2-12 EP 37 (Press Fan)

Press Vent 1

A2-13 EP 38 (Press Fan) Vent

2 Line 1-

- -

Particulate Matter

3 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:00:40

Page 4: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

AE 104 EN 13284-1 SRM Yes 15 Yes Glass Fibre

AE 116 CTM 036 SRM Yes 25 Yes 1, 2 - PPAE114 US EPA M316 SRM Yes 10 Yes WaterAE 105 EN 14790 SRM Yes 20 Yes WaterAE 154 EN 16911-1 SRM Yes 10 - -

AE 102 BS EN 12619 SRM Yes 15 - -

AE 102 EN 14792 SRM Yes 10 - -

AE 102 EN 15058 SRM Yes 6 - -

Oxides of Nitrogen (as NO2) Chemiluminscence

Carbon Monoxide NDIR

Volatile Organic Compounds FID

Stack Gas Temperature & Velocity Calculation

Moisture Gravimetric

Formaldehyde Spectrophotomotry

Isocyanates HPLC - UV

Total Particulate Matter Gravimetric

Method MU (%)UKAS Accredited

Lab Analysis

Absorption Solution / Filter

TypeAnalysis TechniqueSpecies

SOCOTEC UK Technical Procedure

StandardStandard Reference

/ Alternative (SRM/AM) Method

MCERTS Sampling Accreditation

Status

SSP Part 2 - Monitoring Objectives - Instrumental Method Information (Cont.)

4 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:00:40

Page 5: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

Details of data information system None None None None None

Operating records to be collected Yes Yes Yes Yes Yes

Type of CEMs installed None None None None None

Abatement Cyclone Cyclone Cyclone None None

Expected process variations/unusual occurrences

Swirling/negative flow Swirling/negative flow Swirling/negative flow None None

Fuel requirements during monitoring N/A N/A N/A N/A N/A

Normal load, throughput or continuous rating

Normal Load TBC TBC TBC TBC

Part of batch to be sampled during monitoring

N/A N/A N/A N/A N/A

Duration / frequency of batch N/A N/A N/A N/A N/A

Continuous or batch Continuous Continuous Continuous Continuous Continuous

Description of process Wood Fibre Drier Wood Fibre Drier Wood Fibre Drier Wood Fibre Drier Wood Fibre Drier

Details of product Wood fibre board Wood fibre board Wood fibre board Wood fibre board Wood fibre board

SSP Part 2 - Process and Operating Information

Release PointA2-21 EP 9 (Cyclone Line 2) Drier

Stage 1A2-5 EP 34 (Cyclone Line 1) Core

DryerA2-6 EP 35 (Cyclone Line 1) Face

DryerA2-15 EP 25 (Press Fan) Drier

Stage 1A2-22 EP 5 (Press Fan) Vent 1 Line 2

5 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:00:40

Page 6: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

Details of data information system None None None - -

Operating records to be collected Yes Yes Yes - -

Type of CEMs installed None None None - -

Abatement None None None - -

Expected process variations/unusual occurrences

None None None - -

Fuel requirements during monitoring N/A N/A N/A - -

Normal load, throughput or continuous rating

TBC TBC TBC - -

Part of batch to be sampled during monitoring

N/A N/A N/A - -

Duration / frequency of batch N/A N/A N/A - -

Continuous or batch Continuous Continuous Continuous - -

Description of process Wood Fibre Drier Wood Fibre Drier Wood Fibre Drier - -

Details of product Wood fibre board Wood fibre board Wood fibre board - -

SSP Part 2 - Process and Operating Information (Cont.)

Release Point A2-23 EP 6 (Press Fan) Vent 2 Line 2 A2-12 EP 37 (Press Fan) Press Vent 1A2-13 EP 38 (Press Fan) Vent 2

Line 1- -

6 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:00:52

Page 7: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

A2-21 EP 9 (Cyclone Line 2) Drier Stage 1

A2-5 EP 34 (Cyclone Line 1)

Core Dryer

A2-6 EP 35 (Cyclone Line 1)

Face Dryer

A2-15 EP 25 (Press Fan) Drier Stage 1

A2-22 EP 5 (Press Fan) Vent 1 Line 2

A2-23 EP 6 (Press Fan) Vent 2 Line 2

A2-12 EP 37 (Press Fan) Press Vent 1

Circular Circular Circular Circular Circular Circular Circular2.30 2.30 2.30 1.24 1.00 1.00 1.00

- - - - - - -Outside Outside Outside Outside Outside Outside Outside

50 50 50 15 15 15 15

No No No No Yes Yes Yes

Vertical Vertical Vertical Vertical Vertical Vertical Vertical

No No No Yes Yes Yes Yes

4" Non BSP 90mm

4" Non BSP 90mm

4" Non BSP 90mm

4" Non BSP 65mm

4" BSP 90mm

4" BSP 90mm

4" BSP 90mm

1 / 20 1 / 1 1 / 1 2 / 4 2 / 2 2 / 2 2 / 2- - / - - / - - / - - / - - / - - / -

1 / 1 1 / 1 1 / 1 1 / 1 - / - - / - - / -Yes Yes Yes Yes Yes Yes YesNo No No Yes Yes Yes Yes

Yes Yes Yes Yes Yes Yes Yes

Available Utilities Yes Yes Yes Yes Yes Yes YesNo No No Yes Yes Yes Yes

TBC TBC TBC 15.42 15.82 10.39 11.04TBC TBC TBC 18.96 19.14 13.91 14.41No No No Yes Yes Yes YesNo No No Yes Yes Yes YesYes Yes Yes No No No No60 52 60 26 32 28 2315 10.9 15.3 TBC 0.27 1.3 1.5

N/A N/A N/A N/A N/A N/A N/A

N/A N/A N/A N/A N/A N/A N/AIs it an intrinsically safe area? Yes / No No No No No No No No

No No No No No No No

For WID / LCPD Processes: Has a BS EN 15259 Homogeneity test been performed?

Yes / No / N/A, if yes state when performed and previous job ID

Is the sampling location compliant with BS EN 15259? Yes / No / N/A

Any physical restrictions to using required sampling kit? If yes, state the nature of the restriction

Angle of gas flow <=15o

Any localised negative flow

Temperature oCMoisture %

Size of sampling location Adequate work area

Does platform have all safety requirements400 kg point load, handrails, kickboards, ladder guards? Power sockets, Lighting, Water

A velocity traverse will be carried out in accordance with BS EN 13284-1, using a type K thermocouple and a suitable flow

device.

Lowest Differential Pressure >5PaLowest Gas Velocity (m/sec)Highest Gas Velocity (m/sec)Ratio of Gas Velocities <3:1

Number of sampling lines / points per lineCEN Isokinetic StandardsNon CEN Isokinetic StandardsNon-Isokinetic Standards

Access to platform Secured

Distance to nearest upstream / downstream flow disturbance >5 hydraulic diameters

Size & depth of sampling ports>= 125mm diameter for ducts >= 0.7 m diameter

Height of sampling platform from the ground m

Distance from sampling port to edge of platform or obstruction>Stack depth / diameter + wall and port thickness + 1.5m

Orientation of Duct Vertical / Horizontal / Diagonal

Stack Diameter mStack Depth x Width m x mSampling Location Inside / Outside

SSP Part 2 - Sampling Location Details

Parameter Requirement

Stack Shape Circular, Square, Rectangular etc

7 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:00:59

Page 8: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

A2-13 EP 38 (Press Fan) Vent 2 Line 1

- - - - - -

Circular - - - - - -

1.24 - - - - - -

- - - - - - -

Outside - - - - - -

10 - - - - - -

No - - - - - -

Vertical - - - - - -

Yes - - - - - -

4" Non BSP 65mm - - - - - -

2 / 4 - - - - - -

- / - - - - - - -

1 / 1 - - - - - -

Yes - - - - - -

Yes - - - - - -

Yes - - - - - -

Available Utilities Yes - - - - - -

Yes - - - - - -

9.15 - - - - - -

11.46 - - - - - -

Yes - - - - - -

Yes - - - - - -

No - - - - - -

30 - - - - - -

1.43 - - - - - -

N/A - - - - - -

N/A - - - - - -

Is it an intrinsically safe area? Yes / No No - - - - - -

No - - - - - -

For WID / LCPD Processes: Has a BS EN 15259 Homogeneity test been performed?

Yes / No / N/A, if yes state when performed and previous job ID

Is the sampling location compliant with BS EN 15259? Yes / No

Any physical restrictions to using required sampling kit? If yes, state the nature of the restriction

Power sockets, Lighting, Water

A velocity traverse will be carried out in accordance with BS EN 13284-1, using a type K thermocouple and a suitable flow

device.

Lowest Differential Pressure >5Pa

Lowest Gas Velocity (m/sec)

Highest Gas Velocity (m/sec)

Ratio of Gas Velocities <3:1

Angle of gas flow <=15o

Any localised negative flow

Temperature oC

Moisture %

Access to platform Secured

Size of sampling location Adequate work area

Does Platform have all safety requirements400 kg point load, handrails, kickboards, ladder guards?

Size & depth of sampling ports>= 125mm diameter for ducts >= 0.7 m diameter

Number of sampling lines / points per line

CEN Isokinetic Standards

Non CEN Isokinetic Standards

Non-Isokinetic Standards

Distance from sampling port to edge of platform or obstruction>Stack depth / diameter + wall and port thickness + 1.5m

Orientation of Duct Vertical / Horizontal / Diagonal

Distance to nearest upstream / downstream flow disturbance >5 hydraulic diameters

Stack Depth x Width m x m

Sampling Location Inside / Outside

Height of sampling platform from the ground m

Parameter Requirement

Stack Shape Circular, Square Rectangular etc...

Stack Diameter m

SSP Part 2 - Sampling Location Details (cont..)

8 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:00:59

Page 9: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

Accreditation (Testing / Analysis)

Expected Emission at Reference Conditions

Limit of Detection Equipment used Sampling Technique &

Flow Rate

Minimum Sampling Time

(mins)

Estimated Sampling

Volume (m³)

Number of Samples /

Blanks

Analysis Laboratory

Analysis Method

MCERTS / None <ELV mg/m³ ~0.25 mg/m³ Manual Sampling TrainIsokinetic

~20 litres/min60 ~1.2 1 / 1 In House Gravimetric

MCERTS / UKAS < ELV mg/m³ ~0.00006 mg/m³ Manual Sampling TrainIsokinetic

~20 litres/min60 ~1.2 1 / 1 RPS HPLC

MCERTS / UKAS < ELV mg/m³ ~0.083 mg/m³Manual Sampling

TrainIsokinetic 20

Litres/Min60 ~1.2 1 / 1 RPS Spectrophotometry

MCERTS 13.2 % ~0.01% Manual Sampling TrainIsokinetic

~20 litres/min60 ~1.2 1 / 0 In House Gravimetric

Accreditation (Testing / Analysis)

Analytical Technique

Proposed Equipment

Expected Emission at Reference Conditions

Limit of Detection Minimum Sampling Time

(mins)

Proposed Instrument

Range

Proposed Calibration Gas

Conc

MCERTS FID Thermo FID <ELV mg/m³ 0.4 ppm 60 0-100 ppm 80 ppm

MCERTS Chemiluminescene Horiba PG-250 <ELV mg/m³ 0.1 ppm 60 250 ppm 200 ppm

MCERTS NDIR Horiba PG-250 <ELV mg/m³ 0.1 ppm 60 200 ppm 160 ppm

Oxides of Nitrogen

Carbon Monoxide

SSP Part 2 - Monitoring Details for A2-21 EP 9 (Cyclone Line 2) Drier Stage 1 (Instrumental Sampling)Species

VOCs

Formaldehyde

Moisture

Isocyanates

SSP Part 2 - Monitoring Details for A2-21 EP 9 (Cyclone Line 2) Drier Stage 1 (Manual Extractive)Species

Particulate Matter

9 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:01:00

Page 10: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

Accreditation (Testing / Analysis)

Expected Velocity Limit of Detection Equipment used Sampling Technique &

Flow Rate

Minimum Sampling Time

(mins)

Estimated Sampling

Volume (m³)

Number of Traverses / Samples &

Blanks

Analysis Laboratory

Analysis Method

MCERTS <ELV m/s ~0.6 m/secS - Type Pitot & Thermocouple

- - - 1 In House Calculation

Sampling Points

There are no ISO Standard isokinetic tests to be performed on this stackIce Requirements 1.5 kgPhoto Reference Number Not applicable

Isokinetic CEN Standards 2.2, 3.9, 6.7, 9.7, 12.9, 16.5, 20.4, 25, 30.6, 38.8, 61.2, 69.4, 75, 79.6, 83.5, 87.1, 90.3, 93.3, 96.1, 97.8%As a % of sampling line Non CEN Isokinetic Standards

COSHH data COSHH data where applicable for impinger solutions, calibration gases, etc that are used by the sampling team are available on the team leaders laptop.

Additional InformationSpecial Reporting Requirements There are no special reporting requirements related to this installation.

Deviation 4 Due to the erratic nature of the flow at the sampling position a 45 point flow traverse was carried out on each line.Flow Traverse

Deviation 2 As this sampling location shows high levels of turbulence throughout the results from the standard flow traverse are indicative. In the past, reports detailing thevolumetric flow rate according to fan rating have been used to calculate mass emission rates for this stack.Velocity & Volumetric Flow Rates

Deviation 3 Formaldehyde samples will be filtered at the request of Medite therefore the monitoring does not completely adhere to US EPA Method 316.Formaldehyde Monitoring

Velocity & Temperature Traverse

Deviations & COSHH DataDeviation 1 Only one sample line will be accessed safely, the other sample line will not be accessed safely due to excessive probe overhang. It may only be possible to sample from

one representative sampling point for all isokinetic monitoring due to a number of factors i.e. flow being excessively high, swirl being greater than 15° & negative flowexperienced throughout sample point locations. This sampling location will therefore not comply with all the requirements of AG1 & IS EN 16911-1.

Sample Line & Sample point

SSP Part 2 - Velocity TraverseSpecies

10 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:01:00

Page 11: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

Accreditation (Testing / Analysis)

Expected Emission at Reference Conditions

Limit of Detection Equipment used Sampling Technique &

Flow Rate

Minimum Sampling Time

(mins)

Estimated Sampling

Volume (m³)

Number of Samples /

Blanks

Analysis Laboratory

Analysis Method

MCERTS / UKAS <ELV mg/m³ ~0.25 mg/m³ Manual Sampling TrainIsokinetic

~20 litres/min60 ~1.2 1 / 1 In House Gravimetric

MCERTS / UKAS <ELV mg/m³ ~0.00006 mg/m³ Manual Sampling TrainIsokinetic

~20 litres/min60 ~1.2 1 / 1 RPS HPLC

MCERTS / UKAS < ELV mg/m³ ~0.083 mg/m³Manual Sampling

TrainIsokinetic 20

Litres/Min60 ~1.2 1 / 1 RPS Spectrophotometry

MCERTS 13.6 % 0.01% MFCNon Isokinetic 20

Litres/Min60 ~1.2 1 / 0 In House Gravimetric

Accreditation (Testing / Analysis)

Analytical Technique

Proposed Equipment

Expected Emission at Reference Conditions

Limit of Detection Minimum Sampling Time

(mins)

Proposed Instrument

Range

Proposed Calibration Gas

Conc

MCERTS FID Thermo FID <ELV mg/m³ 0.4 ppm 60 0-100 ppm 80 ppm

MCERTS Chemiluminescene Horiba PG-250 < ELV mg/m³ 0.1 ppm 60 250 ppm 200 ppm

MCERTS NDIR Horiba PG-250 < ELV mg/m³ 0.1 ppm 60 200 ppm 160 ppm

Oxides of Nitrogen

Carbon Monoxide

SSP Part 2 - Monitoring Details for A2-5 EP 34 (Cyclone Line 1) Core Dryer (Instrumental Sampling)Species

VOCs

Formaldehyde

Moisture

Isocyanates

SSP Part 2 - Monitoring Details for A2-5 EP 34 (Cyclone Line 1) Core Dryer (Manual Extractive)Species

Particulate Matter

11 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:01:00

Page 12: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

Accreditation (Testing / Analysis)

Expected Velocity Limit of Detection Equipment used Sampling Technique &

Flow Rate

Minimum Sampling Time

(mins)

Estimated Sampling

Volume (m³)

Number of Traverses / Samples &

Blanks

Analysis Laboratory

Analysis Method

MCERTS <ELV m/s ~0.6 m/secS - Type Pitot & Thermocouple

- - - 1 In House Calculation

Sampling Points

Ice Requirements 1.5 kgPhoto Reference Number Not applicable

Isokinetic CEN Standards 2.2, 3.9, 6.7, 9.7, 12.9, 16.5, 20.4, 25, 30.6, 38.8, 61.2, 69.4, 75, 79.6, 83.5, 87.1, 90.3, 93.3, 96.1, 97.8%As a % of sampling line Non-Isokinetic Sampling 40%

COSHH data COSHH data where applicable for impinger solutions, calibration gases, etc that are used by the sampling team are available on the team leaders laptop.

Additional InformationSpecial Reporting Requirements There are no special reporting requirements related to this installation.

Deviation 4 Due to the erratic nature of the flow at the sampling position a 45 point flow traverse was carried out on each line.Flow Traverse

Deviation 2 As this sampling location shows high levels of turbulence throughout the results from the standard flow traverse are indicative. In the past, reports detailing thevolumetric flow rate according to fan rating have been used to calculate mass emission rates for this stack.Velocity & Volumetric Flow Rates

Deviation 3 Formaldehyde samples will be filtered at the request of Medite therefore the monitoring does not completely adhere to US EPA Method 316.Formaldehyde Monitoring

Velocity & Temperature Traverse

Deviations & COSHH DataDeviation 1 Only one sample line will be accessed safely, the other sample line will not be accessed safely due to excessive probe overhang. It may only be possible to sample from

one representative sampling point for all isokinetic monitoring due to a number of factors i.e. flow being excessively high, swirl being greater than 15° & negative flowexperienced throughout sample point locations. This sampling location will therefore not comply with all the requirements of AG1 & IS EN 16911-1.

Sample Line & Sample point

SSP Part 2 - Velocity TraverseSpecies

12 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:01:00

Page 13: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

Accreditation (Testing / Analysis)

Expected Emission at Reference Conditions

Limit of Detection Equipment used Sampling Technique &

Flow Rate

Minimum Sampling Time

(mins)

Estimated Sampling

Volume (m³)

Number of Samples /

Blanks

Analysis Laboratory

Analysis Method

MCERTS / UKAS <ELV mg/m³ ~0.25 mg/m³ Manual Sampling TrainIsokinetic

~20 litres/min60 ~1.2 1 / 1 In House Gravimetric

MCERTS / UKAS <ELV mg/m³ ~0.00006 mg/m³ Manual Sampling TrainIsokinetic

~20 litres/min60 ~1.2 1 / 1 RPS HPLC

MCERTS / UKAS <ELV mg/m³ ~0.083 mg/m³Manual Sampling

TrainIsokinetic 20

Litres/Min60 ~1.2 1 / 1 RPS Spectrophotometry

MCERTS 11.7 % ~0.01% Manual Sampling TrainIsokinetic

~20 litres/min60 ~1.2 1 / 0 In House Gravimetric

Accreditation (Testing / Analysis)

Analytical Technique

Proposed Equipment

Expected Emission at Reference Conditions

Limit of Detection Minimum Sampling Time

(mins)

Proposed Instrument

Range

Proposed Calibration Gas

Conc

MCERTS FID Thermo FID <ELV mg/m³ 0.4 ppm 60 0-100 ppm 80 ppm

MCERTS Chemiluminescene Horiba PG-250 <ELV mg/m³ 0.1 ppm 60 250 ppm 200 ppm

MCERTS NDIR Horiba PG-250 <ELV mg/m³ 0.1 ppm 60 200 ppm 160 ppm

Oxides of Nitrogen

Carbon Monoxide

SSP Part 2 - Monitoring Details for A2-6 EP 35 (Cyclone Line 1) Face Dryer (Instrumental Sampling)Species

VOCs

Formaldehyde

Moisture

Isocyanates

SSP Part 2 - Monitoring Details for A2-6 EP 35 (Cyclone Line 1) Face Dryer (Manual Extractive)Species

Particulate Matter

13 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:01:00

Page 14: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

Accreditation (Testing / Analysis)

Expected Velocity Limit of Detection Equipment used Sampling Technique &

Flow Rate

Minimum Sampling Time

(mins)

Estimated Sampling

Volume (m³)

Number of Traverses / Samples &

Blanks

Analysis Laboratory

Analysis Method

MCERTS <ELV m/s ~0.6 m/secS - Type Pitot & Thermocouple

- - - 1 In House Calculation

Sampling Points

Ice Requirements 1.5 kgPhoto Reference Number Not applicable

Isokinetic CEN Standards 2.2, 3.9, 6.7, 9.7, 12.9, 16.5, 20.4, 25, 30.6, 38.8, 61.2, 69.4, 75, 79.6, 83.5, 87.1, 90.3, 93.3, 96.1, 97.8%As a % of sampling line Non-Isokinetic Sampling 40%

COSHH data COSHH data where applicable for impinger solutions, calibration gases, etc that are used by the sampling team are available on the team leaders laptop.

Additional InformationSpecial Reporting Requirements There are no special reporting requirements related to this installation.

Deviation 4 Due to the erratic nature of the flow at the sampling position a 45 point flow traverse was carried out on each line.Flow Traverse

Deviation 2 As this sampling location shows high levels of turbulence throughout the results from the standard flow traverse are indicative. In the past, reports detailing thevolumetric flow rate according to fan rating have been used to calculate mass emission rates for this stack.Velocity & Volumetric Flow Rates

Deviation 3 Formaldehyde samples will be filtered at the request of Medite therefore the monitoring does not completely adhere to US EPA Method 316.Formaldehyde Monitoring

Velocity & Temperature Traverse

Deviations & COSHH DataDeviation 1 Only one sample line will be accessed safely, the other sample line will not be accessed safely due to excessive probe overhang. It may only be possible to sample from

one representative sampling point for all isokinetic monitoring due to a number of factors i.e. flow being excessively high, swirl being greater than 15° & negative flowexperienced throughout sample point locations. This sampling location will therefore not comply with all the requirements of AG1 & IS EN 16911-1.

Sample Line & Sample point

SSP Part 2 - Velocity TraverseSpecies

14 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:01:00

Page 15: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

Accreditation (Testing / Analysis)

Expected Emission at Reference Conditions

Limit of Detection Equipment used Sampling Technique &

Flow Rate

Minimum Sampling Time

(mins)

Estimated Sampling

Volume (m³)

Number of Samples /

Blanks

Analysis Laboratory

Analysis Method

MCERTS / UKAS <ELV mg/m³ ~0.25 mg/m³ Manual Sampling TrainIsokinetic

~20 litres/min60 ~1.2 1 / 1 In House Gravimetric

MCERTS / UKAS <ELV mg/m³ ~0.083 mg/m³Manual Sampling

TrainIsokinetic 20

Litres/Min60 ~1.2 1 / 1 RPS Spectrophotometry

MCERTS 2.46 % ~0.01% Manual Sampling TrainIsokinetic

~20 litres/min60 ~1.2 1 / 0 In House Gravimetric

Accreditation (Testing / Analysis)

Analytical Technique

Proposed Equipment

Expected Emission at Reference Conditions

Limit of Detection Minimum Sampling Time

(mins)

Proposed Instrument

Range

Proposed Calibration Gas

Conc

MCERTS FID Thermo FID <ELV mg/m³ 0.4 ppm 60 0-100 ppm 80 ppm

MCERTS Chemiluminescene Horiba PG-250 <ELV mg/m³ 0.1 ppm 60 250 ppm 199 ppm

MCERTS NDIR Horiba PG-250 <ELV mg/m³ 0.1 ppm 60 200 ppm 163 ppm

Oxides of Nitrogen

Carbon Monoxide

SSP Part 2 - Monitoring Details for A2-15 EP 25 (Press Fan) Drier Stage 1 (Instrumental Sampling)Species

VOCs

Formaldehyde

Moisture

SSP Part 2 - Monitoring Details for A2-15 EP 25 (Press Fan) Drier Stage 1 (Manual Extractive)Species

Particulate Matter

15 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:01:00

Page 16: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

Accreditation (Testing / Analysis)

Expected Velocity Limit of Detection Equipment used Sampling Technique &

Flow Rate

Minimum Sampling Time

(mins)

Estimated Sampling

Volume (m³)

Number of Traverses / Samples &

Blanks

Analysis Laboratory

Analysis Method

MCERTS <ELV m/s ~0.6 m/secS - Type Pitot & Thermocouple

- - - 1 In House Calculation

Sampling Points

Ice Requirements 1.5 kgPhoto Reference Number Not applicable

Isokinetic CEN Standards 6.7, 25, 75, 93.3%As a % of sampling line Non-Isokinetic Sampling 50%

COSHH data COSHH data where applicable for impinger solutions, calibration gases, etc that are used by the sampling team are available on the team leaders laptop.

Additional InformationSpecial Reporting Requirements There are no special reporting requirements related to this installation.

Velocity & Temperature Traverse

Deviations & COSHH DataDeviation 1 There are no planned deviations from any of the methods used to sample this installation.

SSP Part 2 - Velocity TraverseSpecies

16 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:01:00

Page 17: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

Accreditation (Testing / Analysis)

Expected Emission at Reference Conditions

Limit of Detection Equipment used Sampling Technique &

Flow Rate

Minimum Sampling Time

(mins)

Estimated Sampling

Volume (m³)

Number of Samples /

Blanks

Analysis Laboratory

Analysis Method

MCERTS / None 1.23 mg/m³ ~0.25 mg/m³ Manual Sampling TrainIsokinetic

~20 litres/min60 ~1.2 1 / 1 In House Gravimetric

MCERTS / UKAS <ELV mg/m³ ~0.083 mg/m³Manual Sampling

TrainIsokinetic 20

Litres/Min60 ~1.2 1 / 1 RPS Spectrophotometry

MCERTS 0.29 % ~0.01% Manual Sampling TrainIsokinetic

~20 litres/min60 ~1.2 1 / 0 In House Gravimetric

Accreditation (Testing / Analysis)

Analytical Technique

Proposed Equipment

Expected Emission at Reference Conditions

Limit of Detection Minimum Sampling Time

(mins)

Proposed Instrument

Range

Proposed Calibration Gas

Conc

MCERTS FID Thermo FID <ELV mg/m³ 0.4 ppm 60 0-100 ppm 80 ppm

Accreditation (Testing / Analysis)

Expected Velocity Limit of Detection Equipment used Sampling Technique &

Flow Rate

Minimum Sampling Time

(mins)

Estimated Sampling

Volume (m³)

Number of Traverses / Samples &

Blanks

Analysis Laboratory

Analysis Method

MCERTS <ELV m/s ~0.6 m/secS - Type Pitot & Thermocouple

- - - 1 In House Calculation

Ice Requirements 1.5 kgPhoto Reference Number Not applicable

COSHH data COSHH data where applicable for impinger solutions, calibration gases, etc that are used by the sampling team are available on the team leaders laptop.

Additional InformationSpecial Reporting Requirements There are no special reporting requirements related to this installation.

Formaldehyde mon itoring

Velocity & Temperature Traverse

Deviations & COSHH DataDeviation 1 Formaldehyde samples will be filtered at the request of Medite therefore the monitoring does not completely adhere to US EPA Method 316.

SSP Part 2 - Velocity TraverseSpecies

SSP Part 2 - Monitoring Details for A2-22 EP 5 (Press Fan) Vent 1 Line 2 (Instrumental Sampling)Species

VOCs

Formaldehyde

Moisture

SSP Part 2 - Monitoring Details for A2-22 EP 5 (Press Fan) Vent 1 Line 2 (Manual Extractive)Species

Particulate Matter

17 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:01:00

Page 18: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

Accreditation (Testing / Analysis)

Expected Emission at Reference Conditions

Limit of Detection Equipment used Sampling Technique &

Flow Rate

Minimum Sampling Time

(mins)

Estimated Sampling

Volume (m³)

Number of Samples /

Blanks

Analysis Laboratory

Analysis Method

MCERTS / UKAS <ELV mg/m³ ~0.47 mg/m³ Manual Sampling TrainIsokinetic

~20 litres/min32 ~0.64 1 / 1 In House Gravimetric

MCERTS / UKAS <ELV mg/m³ ~0.083 mg/m³Manual Sampling

TrainIsokinetic 20

Litres/Min60 ~1.2 1 / 1 RPS Spectrophotometry

MCERTS 0.3 % ~0.01% Manual Sampling TrainIsokinetic

~20 litres/min32 ~0.64 1 / 0 In House Gravimetric

Accreditation (Testing / Analysis)

Analytical Technique

Proposed Equipment

Expected Emission at Reference Conditions

Limit of Detection Minimum Sampling Time

(mins)

Proposed Instrument

Range

Proposed Calibration Gas

Conc

MCERTS FID Thermo FID <ELV mg/m³ 0.4 ppm 60 0-100 ppm 80 ppm

Accreditation (Testing / Analysis)

Expected Velocity Limit of Detection Equipment used Sampling Technique &

Flow Rate

Minimum Sampling Time

(mins)

Estimated Sampling

Volume (m³)

Number of Traverses / Samples &

Blanks

Analysis Laboratory

Analysis Method

MCERTS <ELV m/s ~0.6 m/secS - Type Pitot & Thermocouple

- - - 1 In House Calculation

Sampling Points

Ice Requirements 1 kgPhoto Reference Number Not applicable

Isokinetic CEN Standards 14.6, 85.4%As a % of sampling line Non-Isokinetic Sampling -%

COSHH data COSHH data where applicable for impinger solutions, calibration gases, etc that are used by the sampling team are available on the team leaders laptop.

Additional InformationSpecial Reporting Requirements There are no special reporting requirements related to this installation.

Velocity & Temperature Traverse

Deviations & COSHH DataDeviation 1 Formaldehyde samples will be filtered at the request of Medite therefore the monitoring does not completely adhere to US EPA Method 316.Formaldehyde mon itoring

SSP Part 2 - Velocity TraverseSpecies

SSP Part 2 - Monitoring Details for A2-23 EP 6 (Press Fan) Vent 2 Line 2 (Instrumental Sampling)Species

VOCs

SSP Part 2 - Monitoring Details for A2-23 EP 6 (Press Fan) Vent 2 Line 2 (Manual Extractive)Species

Particulate Matter

Moisture

Formaldehyde

18 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:01:00

Page 19: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

Accreditation (Testing / Analysis)

Expected Emission at Reference Conditions

Limit of Detection Equipment used Sampling Technique &

Flow Rate

Minimum Sampling Time

(mins)

Estimated Sampling

Volume (m³)

Number of Samples /

Blanks

Analysis Laboratory

Analysis Method

MCERTS / UKAS <ELV mg/m³ ~0.25 mg/m³ Manual Sampling TrainIsokinetic

~20 litres/min60 ~1.2 1 / 1 In House Gravimetric

MCERTS / UKAS <ELV mg/m³ ~0.00006 mg/m³ Manual Sampling TrainIsokinetic

~20 litres/min60 ~1.2 1 / 1 RPS HPLC

MCERTS / UKAS <ELV mg/m³ ~0.083 mg/m³Manual Sampling

TrainIsokinetic 20

Litres/Min60 ~1.2 1 / 1 RPS Spectrophotometry

MCERTS 0.9 % ~0.01% Manual Sampling TrainIsokinetic

~20 litres/min60 ~1.2 1 / 0 In House Gravimetric

Accreditation (Testing / Analysis)

Analytical Technique

Proposed Equipment

Expected Emission at Reference Conditions

Limit of Detection Minimum Sampling Time

(mins)

Proposed Instrument

Range

Proposed Calibration Gas

Conc

MCERTS FID Thermo FID <ELV mg/m³ 0.4 ppm 60 0-100 ppm 80 ppm

Accreditation (Testing / Analysis)

Expected Velocity Limit of Detection Equipment used Sampling Technique &

Flow Rate

Minimum Sampling Time

(mins)

Estimated Sampling

Volume (m³)

Number of Traverses / Samples &

Blanks

Analysis Laboratory

Analysis Method

MCERTS <ELV m/s ~0.6 m/secS - Type Pitot & Thermocouple

- - - 1 In House Calculation

Sampling Points Isokinetic CEN Standards 14.6, 85.4%As a % of sampling line Non-Isokinetic Sampling -%

COSHH data COSHH data where applicable for impinger solutions, calibration gases, etc that are used by the sampling team are available on the team leaders laptop.

Additional InformationSpecial Reporting Requirements There are no special reporting requirements related to this installation.

Velocity & Temperature Traverse

Deviations & COSHH DataDeviation 1 Formaldehyde samples will be filtered at the request of the site theremore monitoring does not adhere to the US EPA Method 316.Formaldehyde sampling

SSP Part 2 - Velocity TraverseSpecies

SSP Part 2 - Monitoring Details for A2-12 EP 37 (Press Fan) Press Vent 1 (Instrumental Sampling)Species

VOCs

Moisture

Formaldehyde

Isocyanates

SSP Part 2 - Monitoring Details for A2-12 EP 37 (Press Fan) Press Vent 1 (Manual Extractive)Species

Particulate Matter

19 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:01:00

Page 20: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

Ice Requirements 1.5 kgPhoto Reference Number Not applicable

20 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:01:00

Page 21: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

Accreditation (Testing / Analysis)

Expected Emission at Reference Conditions

Limit of Detection Equipment used Sampling Technique &

Flow Rate

Minimum Sampling Time

(mins)

Estimated Sampling

Volume (m³)

Number of Samples /

Blanks

Analysis Laboratory

Analysis Method

MCERTS / UKAS <ELV mg/m³ ~0.47 mg/m³ Manual Sampling TrainIsokinetic

~20 litres/min32 ~0.64 1 / 1 In House Gravimetric

MCERTS / UKAS <ELV mg/m³ ~0.00006 mg/m³ Manual Sampling TrainIsokinetic

~20 litres/min60 ~1.2 1 / 1 RPS HPLC

MCERTS / UKAS <ELV mg/m³ ~0.083 mg/m³Manual Sampling

TrainIsokinetic 20

Litres/Min60 ~1.2 1 / 1 RPS Spectrophotometry

MCERTS 0.4 % ~0.01% Manual Sampling TrainIsokinetic

~20 litres/min32 ~0.64 1 / 0 In House Gravimetric

Accreditation (Testing / Analysis)

Analytical Technique

Proposed Equipment

Expected Emission at Reference Conditions

Limit of Detection Minimum Sampling Time

(mins)

Proposed Instrument

Range

Proposed Calibration Gas

Conc

MCERTS FID Thermo FID <ELV mg/m³ 0.4 ppm 60 0-100 ppm 80 ppm

Accreditation (Testing / Analysis)

Expected Velocity Limit of Detection Equipment used Sampling Technique &

Flow Rate

Minimum Sampling Time

(mins)

Estimated Sampling

Volume (m³)

Number of Traverses / Samples &

Blanks

Analysis Laboratory

Analysis Method

MCERTS <ELV m/s ~0.6 m/secS - Type Pitot & Thermocouple

- - - 1 In House Calculation

Sampling Points Isokinetic CEN Standards 6.7, 25, 75, 93.3%As a % of sampling line Non-Isokinetic Sampling 50%

COSHH data COSHH data where applicable for impinger solutions, calibration gases, etc that are used by the sampling team are available on the team leaders laptop.

Additional InformationSpecial Reporting Requirements There are no special reporting requirements related to this installation.

Deviations & COSHH DataDeviation 1 Formaldehyde samples will be filtered at the request of Medite therefore the monitoring does not completely adhere to US EPA Method 316.Formaldehyde Monitoring

SSP Part 2 - Velocity TraverseSpecies

Velocity & Temperature Traverse

SSP Part 2 - Monitoring Details for A2-13 EP 38 (Press Fan) Vent 2 Line 1 (Instrumental Sampling)Species

VOCs

Moisture

Formaldehyde

Isocyanates

SSP Part 2 - Monitoring Details for A2-13 EP 38 (Press Fan) Vent 2 Line 1 (Manual Extractive)Species

Particulate Matter

21 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:01:00

Page 22: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

Ice Requirements 1 kgPhoto Reference Number Not applicable

22 of 23 Medite Europe Limited

Clonmel

LEK 12100 Version 1

18-20 Feb 2020

For

insp

ectio

n pur

pose

s only

.

Conse

nt of

copy

right

owne

r req

uired

for a

ny ot

her u

se.

EPA Export 27-05-2020:04:01:00

Page 23: SITE SPECIFIC PROTOCOL (SSP) · Kelvin South Business Park East Kilbride G75 0YF Level Expiry TE1 TE2 TE3 TE4 H&S Enda Flood MM12 1170 MCERTS Level 2 Apr 2023 Mar 2024 Mar 2024 Jun

SOCOTEC UK LTD

socotec.co.uk

It is confirmed that:

• This SSP adequately reflects the scope of work described in the  corresponding proposal with no anomalies.• Adequate resources are available to complete the work specified in this SSP.• SOCOTEC UK has the capability to complete the work specified in this SSP.• The expected report turnaround for the work specified in this SSP is 20 working days.

End of Site Specific Protocol