SITE NAME: SITE NUMBER: AUGMENT ID: DN72XC020M17.1 … · may vary due to site specific conditions....
Transcript of SITE NAME: SITE NUMBER: AUGMENT ID: DN72XC020M17.1 … · may vary due to site specific conditions....
TITLE SHEET
T-1
DN72XC020
DN72XC020M17.1
CO0190 - PHASE 1A
4490 E BLANEY ROAD
PEYTON, CO 80831
W I R E L E S S
540 W. MADISON ST.
17TH FLOOR
CHICAGO, IL 60661
www.sacw.com
312.895.4977
A NOKIA COMPANY
ä
ä
LETS America, Inc.
·
·
R
Call before you dig.below.Know what's
TO OBTAIN LOCATION OF PARTICIPANTS
UNDERGROUND FACILITIES BEFORE
YOU DIG IN COLORADO, CALL
COLORADO 811
TOLL FREE: 1-800-922-1987 OR
www.co811.org
COLORADO STATUTE
REQUIRES MIN OF 2
WORKING DAYS NOTICE
BEFORE YOU EXCAVATE
NORTH NORTH
CO0190-PHASE 1A
DN72XC020
DN72XC020M17.1
4496 E BLANEY ROAD
PEYTON, CO 80831
EL PASO COUNTY
PIKES PEAK REGIONAL BUILDING DEPARTMENT
260'-0" SELF-SUPPORT TOWER
MWDO PROJECT
SITE NAME:
SITE NUMBER:
AUGMENT ID:
ADDRESS:
JURISDICTION:
SITE TYPE:
PROGRAM TYPE:
SITE
SITE
10/27/17
X
X
X-X
X
X-X
X
X-X
NEW ANTENNA
EXISTING ANTENNA
EXISTING MW ANTENNA
NEW MW ANTENNA
GROUND ROD
GROUND BUS BAR
MECHANICAL GRND. CONN.
CADWELD
GROUND ACCESS WELL
ELECTRIC BOX
TELEPHONE BOX
LIGHT POLE
FND. MONUMENT
SPOT ELEVATION
SET POINT
REVISION
GRID REFERENCE
DETAIL REFERENCE
ELEVATION REFERENCE
SECTION REFERENCE
GROUT OR PLASTER
EXISTING BRICK
EXISTING MASONRY
CONCRETE
EARTH
GRAVEL
PLYWOOD
SAND
STEEL
WOOD CONT.
WOOD BLOCKING
CENTERLINE
P PROPERTY/LEASE LINE
MATCH LINE
WORK POINT
GROUND CONDUCTOR
TELEPHONE CONDUIT
ELECTRICAL CONDUIT (POWER)
COAXIAL CABLE
FIBER CABLE
TELCO/ELECTRICAL CONDUCTORS
FIBER/ELECTRICAL CONDUITS
CHAIN LINK FENCING
CAT5E/WAVEGUIDE
C
L
L
NEW IBR 1300
DN72XC020
DN72XC020M17.1
CO0190 - PHASE 1A
4490 E BLANEY ROAD
PEYTON, CO 80831
W I R E L E S S
540 W. MADISON ST.
17TH FLOOR
CHICAGO, IL 60661
www.sacw.com
312.895.4977
A NOKIA COMPANY
ä
ä
LETS America, Inc.
GENERAL NOTES,
LEGEND &
ABBREVIATIONS
T-2
10/27/17
XXXXXXXX
XX
XX
XX
XX
X
X X X X X X X X X X X X X
XX
XX
XX
XX
X
XX
X
XX
XX
X X X
XX
OVERALL &
ENLARGED SITE
PLANS
DN72XC020
DN72XC020M17.1
CO0190 - PHASE 1A
4490 E BLANEY ROAD
PEYTON, CO 80831
W I R E L E S S
540 W. MADISON ST.
17TH FLOOR
CHICAGO, IL 60661
www.sacw.com
312.895.4977
A NOKIA COMPANY
ä
ä
LETS America, Inc.
A-1
NORTHNORTH
10/27/17
EXISTING & NEW
ANTENNA LAYOUTS,
MOUNTING &
SCHEDULE
DN72XC020
DN72XC020M17.1
CO0190 - PHASE 1A
4490 E BLANEY ROAD
PEYTON, CO 80831
W I R E L E S S
540 W. MADISON ST.
17TH FLOOR
CHICAGO, IL 60661
www.sacw.com
312.895.4977
A NOKIA COMPANY
ä
ä
LETS America, Inc.
A-2
NORTH
NORTH
±
10/27/17
EXISTING & NEW
ELEVATIONS
DN72XC020
DN72XC020M17.1
CO0190 - PHASE 1A
4490 E BLANEY ROAD
PEYTON, CO 80831
W I R E L E S S
540 W. MADISON ST.
17TH FLOOR
CHICAGO, IL 60661
www.sacw.com
312.895.4977
A NOKIA COMPANY
ä
ä
LETS America, Inc.
A-3
10/27/17
EQUIPMENT
DETAILS & SINGLE
LINE DIAGRAM
DN72XC020
DN72XC020M17.1
CO0190 - PHASE 1A
4490 E BLANEY ROAD
PEYTON, CO 80831
W I R E L E S S
540 W. MADISON ST.
17TH FLOOR
CHICAGO, IL 60661
www.sacw.com
312.895.4977
A NOKIA COMPANY
ä
ä
LETS America, Inc.
A-4
10/27/17
SCHEMATIC
GROUND PLAN &
DETAILS
ANTENNA GROUND BUS BAR NEAR ANTENNA MOUNTS WITH COAX GROUND KIT.
EQUIPMENT GROUND BUS BAR NEAR EQUIPMENT WITH COAX GROUND KIT.
#6 AWG GROUND FROM ANTENNA GROUND BUS BAR TO TIE INTO EXISTING
GROUNDING SYSTEM (TYP OF (2) PLACES).
#6 AWG GROUND FROM ANTENNAS TO ANTENNA GROUND BUS BAR.
#6 AWG GROUND FROM RADIOS TO ANTENNA GROUND BUS BAR.
#6 AWG GROUND MMBTS GROWTH CABINET TO NEW EQUIPMENT GROUND BUSS BAR.
#6 AWG GROUND FROM NEW GROUND BUS BAR TO TIE INTO EXISTING GROUNDING
SYSTEM (TYP OF (2) PLACES).
GROUND FROM CABINETS TO NEW EQUIPMENT GROUND BUS BAR.
1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND CONSTRUCTION
MAY VARY DUE TO SITE SPECIFIC CONDITIONS.
2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC COMPONENTS
USING GROUND WIRES AND CONNECT TO SURFACE MOUNTED BUS BARS, FOLLOW ANTENNA
AND BTS MANUFACTURES PRACTICES FOR GROUNDING REQUIREMENTS. GROUND COAX
SHIELDS AT BOTH ENDS AND EXIT FROM TOWER OR POLE USING MFR'S PRACTICES.
3. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE ABOVE GROUND.
4. CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE. GROUNDING AND OTHER
OPERATIONAL TESTING WILL BE WITNESSED BY AN SPRINT REPRESENTATIVE.
5. REFER TO DIVISION 16 GENERAL ELECTRIC; GENERAL ELECTRICAL PROVISION AND COMPLY
WITH ALL REQUIREMENTS OF GROUNDING STANDARDS.
6. CONTRACTOR TO ABIDE BY ALL SPRINT SAFETY STANDARDS DURING SITE CONSTRUCTION.
7. CONTRACTOR SHALL REFER TO SPRINT STANDARDS FOR GROUNDING CONNECTIONS &
INSTALLATION METHODS.
8. ELECTRICAL CONTRACTOR TO PROVIDE DETAILED DESIGN OF GROUNDING SYSTEM, AND
RECEIVE APPROVAL OF DESIGN BY AUTHORIZED SPRINT REPRESENTATIVE, PRIOR TO
INSTALLATION OF GROUNDING SYSTEM. PHOTO DOCUMENT ALL CADWELDS AND GROUND
RING.
9. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES INSTALLING GROUNDING
SYSTEM DUE TO SITE SOIL CONDITIONS.
10.GROUNDING ROD NOTES (WHERE APPLICABLE)
11.ELECTRICAL CONTRACTOR SHALL ORDER GROUND RESISTANCE TESTING ONCE THE GROUND
SYSTEM HAS BEEN INSTALLED; A QUALIFIED INDIVIDUAL. UTILIZING THE FALL OF POTENTIAL
METHOD, SHOULD PERFORM THE TEST. THE REPORT WILL SHOW THE LOCATION OF THE TEST
AND CONTAIN NO LESS THAN 9 TEST POINTS ALONG THE TESTING LINE, GRAPHED OUT TO
SHOW THE PLATEAU.
12.POINT GROUND TEST OR 3 POINT 62% TESTS WILL NOT BE ACCEPTED AS ALTERNATIVES TO
THE AFORE MENTIONED GROUND TESTS. TEST SHALL BE PERFORMED WHILE THE
COUNTERPOISE IS ISOLATED. TEST SHALL BE PERFORMED WHILE THE COUNTERPOISE IS
ISOLATED FROM THE A/C SYSTEM GRIDS AND EXISTING COMMUNICATIONS FACILITY.
DN72XC020
DN72XC020M17.1
CO0190 - PHASE 1A
4490 E BLANEY ROAD
PEYTON, CO 80831
W I R E L E S S
540 W. MADISON ST.
17TH FLOOR
CHICAGO, IL 60661
www.sacw.com
312.895.4977
A NOKIA COMPANY
ä
ä
LETS America, Inc.
G-1
1
2
3
4
5
6
7
8
10/27/17