Site Inspection Report

4
Form Information Form Name: WW Site Inspection Report Submitter Name: Wayne Chissell (waynechissell) Submission Date: Mar 24, 2014 10:05:27 PM GMT Project Details: Insert Project Name: Newspaper house Insert Project Address: Test Lane, Southampton Project Details: Overlay to existing Sika Sarnafil roof Client Details: Insert Client Name: Stewart Chessell Approved Contractor Details: Company Name: Kevin Hardie Roofing and Building Contracts Manager: Kevin Hardie Approved Operatives: Mike O'malley / Steve Cameron / Zach Baserable Contact Details: 01202 532400 / 07973890781 Roof Construction and Westwood System Installed: Batch Number: Wecryl 230 Thix - 116-743-005 Substrate: Prepared existing Sika Sarnafil PVC Membrane. Cold Roof: No Warm Roof: Existing insulation underneath the existing single ply. Primer Installed: N/A Waterproofing System: Wecryl 230 Hardwearing Layer: Wecryl 233 and quarts sand to walkway areas Finish: Wecryl 288 applied to walkway areas. Areas Inspected: Site Storage of Products: Satisfactory Substrate Suitability/Condition: Satisfactory Installation of Primer: N/A Detailing Application: Satisfactory. Outlets/Pipes: Satisfactory. Field Area Application: Satisfactory. Comments: Comments: No problems to mention, application proceeding along well. Photographic Report: 1

description

Newspaper House, Southampton

Transcript of Site Inspection Report

Page 1: Site Inspection Report

 Form Information    Form Name: WW Site Inspection ReportSubmitter Name: Wayne Chissell (waynechissell)Submission Date: Mar 24, 2014 10:05:27 PM GMT

    Project Details: Insert Project Name: Newspaper houseInsert Project Address: Test Lane, SouthamptonProject Details: Overlay to existing Sika Sarnafil roof Client Details: Insert Client Name: Stewart Chessell Approved Contractor Details: Company Name: Kevin Hardie Roofing and BuildingContracts Manager: Kevin HardieApproved Operatives: Mike O'malley / Steve Cameron / Zach BaserableContact Details: 01202 532400 / 07973890781 Roof Construction and Westwood System Installed: Batch Number: Wecryl 230 Thix - 116-743-005Substrate: Prepared existing Sika Sarnafil PVC Membrane.Cold Roof: NoWarm Roof: Existing insulation underneath the existing single ply.Primer Installed: N/AWaterproofing System: Wecryl 230Hardwearing Layer: Wecryl 233 and quarts sand to walkway areasFinish: Wecryl 288 applied to walkway areas. Areas Inspected: Site Storage of Products: SatisfactorySubstrate Suitability/Condition: SatisfactoryInstallation of Primer: N/ADetailing Application: Satisfactory.Outlets/Pipes: Satisfactory.Field Area Application: Satisfactory. Comments: Comments: No problems to mention, application proceeding

along well. Photographic Report: 

1

  

Page 2: Site Inspection Report

Picture 1

Picture 1 Comments: Area to be installed.Picture 2

Picture 2 Comments: Installation of the upstand underway.Picture 3

Picture 3 Comments: Embedment coat being applied.Picture 4

Picture 4 Comments: Vertical detailing being installed.

2

  

Page 3: Site Inspection Report

Picture 5

Picture 5 Comments: Satisfactory application so far.Picture 6

Picture 6 Comments: Flat area installation underway.Picture 7

Picture 7 Comments: Embedment coat being installed.Picture 8

 Remedial Action if Required: 

3

  

Page 4: Site Inspection Report

Remedial action if required: No remedial action required at this time. Report Completion: After an inspection has been made of a Westwood roof that is to be covered by a warranty, the area inspected isdeemed to be complete. All other trades must therefore ensure that full adequate projection of the completed worksis undertaken using hardboard sheets or ply wood with tapped joints. The company reserces the right to re-inspectcompleted areas at their discretion if deemed necessary.

Interim inspection reports are to be supported by a final inspection report on completion of the works.

"Copies of the report are to be issued to the Westwood approved contractor, Please note that it is theresponsibility of the approved contractor to pass a copy to their clients."Further visits required: YesPassed for warranty: NoReport complied by: Wayne ChissellSignature

 

4