SIT - Ajutaj 1
Transcript of SIT - Ajutaj 1
-
8/3/2019 SIT - Ajutaj 1
1/8
SIT Group
INTEGRATED SYSTEM
PERFORMING THE GAS/AIR
FLOW CONTROL AND MIXING
Application
Fan assisted gas firedappliances with premixburner. 390 MIXER isparticularly suitable formodulating condensingboilers.
SIT 390 MIXER
9.955.048
048
Subjecttochangewithoutnotice
Main features
Two heat-input models.Wide modulation range.
w w w . s i t g r o u p . i t
-
8/3/2019 SIT - Ajutaj 1
2/8
CONSTRUCTION CHARACTERISTICS
Die casting aluminium body
Air signal to the gas/air control connection
MECHANICAL CONNECTIONS
Mounting Position Downstream of the fan
Gas families 2nd and 3rd
Ambient temperature No inconvenience in operation within standard
working condition of gas appliances (-20....+100 C)
USE SPECIFICATION
Air inlet and mixture outlet M5 (4) Flanges
Gas inlet G 3/4 ISO 228
or: Rp 1/2 ISO 7
or: M4 (4) Flanges
Air signal 6.5 mm
GENERAL DATA
2
1 Gas/Airmixture outlet.
2 Air Inlet.
3 Gas Inlet.
4 Air signal connection.
DESCRIPTION
1
2
3 4
-
8/3/2019 SIT - Ajutaj 1
3/8
3
Maximum heat input available with reference to the pressure drop between the outlet and theinlet of the 390 MIXER in operating condition.Reference conditions: gas G20.
MAXIMUM HEAT INPUT
MINIMUM HEAT INPUT
5 kW
7 kW
Minimum HeatModel MIXER
390. 0xx
390. 1xx
Model MIXER
35 kW
25 kW
# 2
# 1
Reference HeatInput
390. 0xx
390. 1xx
The minimum available heat input is strictly related to the appliance characteristics.As a general guideline the minimum heat input is 20% of the maximum(modulation range 1:5).In the following table the nominal value of the minimum heat input, when theminimum pressure drop between the inlet of 390 MIXER and gas injection section is50 Pa, is reported.Reference conditions: gas G20, gross calorific value.
CAPACITY
0 50 100 150 200 250 300 350 400 450 500 550 600
0
9
18
27
36
45
54
650 700
10
20
30
40
50
60
0
Maximum Heat Input (indicative)
Heat Inputbased on gross CV
Heat Inputbased on nett CV
p [Pa]
# 2
# 1
kW kW
-
8/3/2019 SIT - Ajutaj 1
4/8
4
OPERATION
Stand by - With the appliance in not-operating condition there is no air flow and the gas
way is closed by the gas/air control valves.
Pre-purge - When the appliance is in pre-purge condition there is air flow throughMIXER.
848 SIGMA
390 MIXER
gas
848 SIGMA
air
gas
390 MIXER
-
8/3/2019 SIT - Ajutaj 1
5/8
5
The inner profiles of MIXER are designed and realised in order to ensure the mixingfunctions and to increase the modulating range.
INNER VIEW
390 MIXER
Venturi Pipe
Air signal
compensation chamber
Gas inlet chamber
Gas/Air mixing
chamber
Operating - Automatic shut off valves open. The gas flows through the control andit is injected inside the MIXER in the mixing chamber. Then the gas/air mixture leavesthe MIXER and goes to the burner.
848 SIGMA
gas
air
390 MIXER
OPERATION
-
8/3/2019 SIT - Ajutaj 1
6/8
LAY-OUT ASSEMBLING
GAS
AIR
MIXTURE
BURNER
FAN
390 MIXER
AIR SIGNAL
848 SIGMA
6
-
8/3/2019 SIT - Ajutaj 1
7/8
DIMENSIONS
7
70
70
96
47
60
50
54
6.5
50
60
G3/4
ISO2
28
32
24
24
32
GasConnectio
n:Flangesversion
GasConnection:G
3/4version
-
8/3/2019 SIT - Ajutaj 1