SIMULATION AND IMPLEMENTATION O F THE THREE SWITCH … · SIMULATION AND IMPLEMENTATION O F THE...
Transcript of SIMULATION AND IMPLEMENTATION O F THE THREE SWITCH … · SIMULATION AND IMPLEMENTATION O F THE...
SIMULATION AND IMPLEMENTATION OF THE THREE SWITCH
SERIAL INPUT INTERLEAVED FORWARD CONVERTER
R. Lakshmi1, Dr Joseph Henry
2, Dr K. Rajan
3
1Research Scholar, Vel Tech Dr.RR & Dr.SR University, Chennai-62,
2Professor, Vel Tech Dr.RR & Dr.SR University, Chennai-62,
3Professor, Vel Tech Engineering College, Chennai-62, India.
ABSTRACT
Forward converter used for producing isolated and controlled DC voltage from the unregulated dc
input supply. This paper deals with simulation and implementation of three switch Interleaved Forward
Converter for telecommunication application. The simulation results of three switch forward converter with
LC filter and experimental results obtained from the hardware prototype confirm the theoretical analysis
and the performance of the proposed converter. The experimental results are compared with those of the
simulation.
Keywords: Interleaved Forward Converter, DC-DC Converter, Matlab, and Microcontroller.
1. INTRODUCTION
Many industrial applications require DC power and there is a great need for the stepping down of the
voltage of DC in many an electronic gadget such as mobile phones, laptops, etc. This kind of conversion of the
voltage of the same type of current is achieved by what is called DC to DC converter which is an Electronic
Converter that converts DC voltage from one level to another. DC to DC converters (with isolation) effectuate the
conversion, by storing the input energy temporarily and then releasing it to the output at a different voltage level.
DC to DC converters are indispensable in portable electronic devices such as cellular phones and computers which
get their power from their batteries.
DC to DC converters (with isolation) use what is called Galvanic isolation. It is the principle of isolating
functional sections of electrical system by preventing the flow of charge carrying particles from one section to
another, i.e., there is electric current flowing directly from one section to the next. Energy and/or information can
still be exchanged between the sections by other means such as capacitance, inductance, electromagnetic waves,
optical, acoustic or mechanical means. Converters with galvanic isolation are of two types, namely Flyback
converter and Forward converter. Forward converter is a popular switched mode power supply (SMPS) circuit that
is used for producing isolated and controlled DC voltage from the unregulated DC input supply. Forward converters
find applications in Power supply for DC motor, Battery charging, Battery operated Electric vehicle, Telecom
industry etc.
“Simulation and Implementation of the Two Switch Serial Input Interleaved Forward Converter” Indian
Journal of Science and Technology by R. lakshmi (June 2015). “Comparison of Two Switch and Three Switch
Serial Input Interleaved Forward Converters” International Journal of Innovative Research in Science, Engineering
and Technology by R. lakshmi (February 2014). Analysis and Design of Forward Converter with Energy
Regenerative Snubber is given by Smedley (2010). Reducing common-mode noise in two-switch forward converter
is given by Kong (2011). Design of High Efficiency Flyback Converter with Energy Regenerative Snubber is given
by Liao (2008). An Efficient Active LC Snubber for Forward Converters is given by Jinno (2009). Zero-voltage
switching post regulation scheme for multi output forward converter with synchronous switches is given by Kim
(2011). Wide Range Dual Switch Forward-Flyback Converter with Symmetrical RCD Clamp is given by Wei
(2005). Transformerless Double-Conversion UPS Using a Regenerative Snubber Circuit is given by Reinert (2009).
Spike Suppression Method of Bidirectional High Frequency Inverter using a Regenerative Snubber is given by
Ramli (2004). Efficiency Improvement for SR Forward Converters with LC Snubber is given by Jinno (2001). A
International Journal of Pure and Applied MathematicsVolume 119 No. 10 2018, 1105-1115ISSN: 1311-8080 (printed version); ISSN: 1314-3395 (on-line version)url: http://www.ijpam.euSpecial Issue ijpam.eu
1105
New Interleaved Series Input Parallel Output (ISIPO) Forward Converter with Inherent Demagnetizing Features is
given by Taotao (2008). As the literature cited above does not give instances of studies comparing simulation and
experimental results of three switch interleaved forward converter, this work chooses to compare the experimental
results with those of simulation. The implementation of three switch forward converter using PIC controller is also
not available in the reports of recent research. Hence this work proposes embedded controller for the control of
TSFC system.
2. FORWARD CONVERTER
The block diagram of Three switch Forward converter system is shown in Fig1. This converter converts
unregulated DC power to regulated DC power. It comprises high frequency transformer which is also called
isolation transformer. This provides isolation between the load and the main circuit. As the frequency increases, the
size of the transformer decreases. This is because the flux decreases with the increase in the frequency of the
transformer.
Fig 1 Block Diagram of Forward Converter system
2.1 DC LOAD
The output power is regulated DC power which can be used in applications like speed control of the motor,
battery charging, telecommunication, computers, cellular phones, electrical drives, and other applications which
need DC power.
2.2 THREE SWITCH FORWARD CONVERTER
The three switch forward converter as three switches T1, T2 and T3 which turns on, transferring energy
through the transformer primary into the secondary. On the secondary, the forward rectifying diode conducts,
transferring the energy into the output filter and load.
2.3 MICRO CONTROLLER
Micro controller is used to generate triggering pulses for the MOSFETs. The triggering pulses are of same
width and have equal intervals of time. It is also used to control the output of the Forward converter by varying the
pulse width applied to the MOSFET. Microcontrollers have more advantages like fast response, low cost, small
size, and improved reliability etc., compared with to the analog circuits.
3. SIMULATION RESULTS
The simulink model for three switch DC-DC converter is shown in Fig 2. The scopes are connected to measure
output voltage, output current and output power. The output power is obtained by multiplying the output voltage and
International Journal of Pure and Applied Mathematics Special Issue
1106
the output current. The energies in the transformer secondaries are added and stored in the LC filter and then it is
released to the load.
Fig 2 Circuit diagram of three switch forward converter
DC input voltage is shown in Fig 3 and its value is 300Volts.
Fig 3 Input voltage
The switching pulses for M1, M2 and M3 of three switch forward converter system are shown in Fig 4.
Fig 4 Switching pulses for M1, M2 & M3
International Journal of Pure and Applied Mathematics Special Issue
1107
The volage across primary and secondary of the transformer 1 are shown in Fig 5.
Fig 5 Primary and secondary voltages of the Transformer1
The voltage across the primary and secondary of the Transformer 2 are shown in Fig 6.
Fig 6 Primary and secondary voltages of theTransformer2
The DC output voltage is shown in Fig 7. The output voltage is 48.35V
Fig 7 Output voltage
The output current and output power are shown in Figs 8 and 9 respectively. The output current is 9.7A and
the output power is 469 Watts.
International Journal of Pure and Applied Mathematics Special Issue
1108
Fig 8 Output current
Fig 9 Output power
Fig 10 Output voltage ripple with LC filter
4. HARDWARE PARAMETERS
Hardware parameters of two switch forward converter with resistive load are shown in the table1. A step-down
230/15V transformer is used to give input supply to the power circuit. The 15V AC input is rectified into 15V pulsating DC
with the help of full bridge rectifier circuit.
An output voltage of 12V obtained from the output pin of 7812 is fed as the supply to the pulse amplifier. An output
voltage of 5V obtained from the output pin of 7805 is fed as the supply to the pic controller. Pic controller generates gate
pulses for mosfet. These generated pulses are amplified by pulse amplifier and fed to mosfets. The load used in this two
switch forward converter is 330ohm. The hardware is fabricated and tested. The experimental results are also described.
International Journal of Pure and Applied Mathematics Special Issue
1109
Vin 48V
L 1µH
C1,C2 47µF
C3 104µF
C4,C5 1000µF
RL 330Ω
MOSFET(IRF840) 500V/8A
DIOED 230V/1A
V0 12V
Table 1 Hardware Parameters of Three switch Forward Converter
4. HARDWARE INVESTIGATIONS
The hardware setup of three switch forward converter with R load is shown in Fig 11. The hardware
consists of control circuit and power circuit. DC input voltage is shown in Fig 12. Switching pulse1 and
output of driver1 are shown in Figs 13 & 14 respectively. The Drain to source voltage and switching pulse 2 is
shown in Fig 15. Transformer primary and secondary voltages are shown in Figs 16 & 17 respectively. DC
output voltage is shown in Fig 18.
International Journal of Pure and Applied Mathematics Special Issue
1110
Fig 11 Hardware setup
Fig 12 Input Voltage (48V)
Fig 13 Switching pulse for M1 (5V)
International Journal of Pure and Applied Mathematics Special Issue
1111
Fig 14 Output of Driver1 (12V)
Fig 15 Drain to Source Voltage and switching pulse for M2 (5V)
Fig 16 Voltage across the Primary of the Transformer
International Journal of Pure and Applied Mathematics Special Issue
1112
Fig 17 Voltage across the secondary of the transformer
Fig 18 DC Output Voltage (12V)
CONCLUSION
The three switch serial input interleaved forward converters were modeled and simulated using MATLAB
Simulink. The simulation results were found to be inline with the predictions. The hardware was fabricated and
tested. The experimental results obtained from the hardware prototype were found to support the theoretical
analysis and the performance of the proposed converter. They are almost similar to the simulation results.
The scope of this study includes the modeling, the simulation and the implementation of closed loop
controlled three switch ILFC system.
REFERENCES
1. R.Lakshmi , Dr. K.Rajan, ”Comparison of Two Switch And Three Switch Serial Input Interleaved Forward
Converters” International Journal of Innovative Research in Science, Engineering and Technology.,Vol. 3,
Issue 2, February 2014, pp 9349 to 9359.
2. R.Lakshmi , Dr K.Rajan, “Closed Loop Control Of Two Switch Serial Input Interleaved Forward
Converter” International Journal of Research in Engineering & Advanced Technology., Volume 2, Issue 1,
Feb-Mar 2014, pp 1 to 8.
3. R.Lakshmi , Dr K.Rajan, “Closed Loop Control Of The Two Switch Serial Input Interleaved Forward
Converter Fed DC Drive” The International Journal Of Science & Technoledge., Vol 2 Issue 3 March,
2014, pp 45 to 48.
International Journal of Pure and Applied Mathematics Special Issue
1113
4. R.Lakshmi , Dr K.Rajan, “Comparison of Transient Responses of Closed Loop Controlled Two
Switch and Three Switch Interleaved Forward Converter Systems” International Journal of Applied
Engineering Research, Volume 9, Number 23 (2014) pp. 20797-20804.
5. R.Lakshmi , K. Diwakar and K.Rajan, “Simulation and Implementation of the Two Switch Serial Input
Interleaved Forward Converter” Indian Journal of Science and Technology, Vol 8(11), June 2015.
6. Alexander Abramovitz, Tang Cheng, and Keyue Smedley, “Analysis and Design of Forward Converter
With Energy Regenerative Snubber,” IEEE Transactions On Power Electronics, Vol. 25, No. 3, March
2010.
7. P. Kong, S. Wang, F. C. Lee, and Z. Wang, “Reducing common-mode noise in two-switch forward
converter,” IEEE Trans. Power Electron., vol. 26, no. 5, pp. 1522–1533, May 2011.
8. C.S. Liao and K.M. Smedley, “Design of High Efficiency Flyback Converter with Energy Regenerative
Snubber,” in Proc. Appl. Power Electron.Conf. Expo. (APEC 2008), 24–28 Feb., pp. 796–800.
9. M. Jinno, P. Y. Chen and K. C. Lin, “An Efficient Active LC Snubber for Forward Converters,” IEEE
Trans. Power Electron., vol. 24, no. 6, pp. 1522–1531, Jun. 2009.
10. J. K. Kim, S.-W. Choi, and G.-W. Moon, “Zero-voltage switching post regulation scheme for multi output
forward converter with synchronous switches,” IEEE Trans. Ind. Electron., vol. 58, no. 6, pp. 2378– 2386,
Jun. 2011.
11. Y. Wei, X. Wu, Y. Gu and H. Ma, “Wide Range Dual Switch Forward-Flyback Converter with
Symmetrical RCD Clamp,” IEEE Trans. Power Electron, 2005.
12. M. R. Reinert, C. Rech, M. Mezaroba and L. Michels, “Transformerless Double-Conversion UPS Using a
Regenerative Snubber Circuit,” IEEE Trans. Power Electron, 2009.
13. Z. Sajam, M. Z. Ramli and L. S. Toh, “Spike Suppression Method of Bidirectional High Frequency Inverter
using a Regenerative Snubber,” IEEE Trans. Power Electron, 2004.
14. M. Jinno, “Efficiency Improvement for SR Forward Converters with LC Snubber,” IEEE Trans. Power
Electron., vol. 16, no. 6, pp. 812–820, Nov. 2001.
15. J. Taotao, K. Zhang and K. Smedley, “A New Interleaved Series Input Parallel Output (ISIPO) Forward
Converter with Inherent Demagnetizing Features,” IEEE Trans. Power Electr., vol. 23, no. 2, pp. 888–895,
Mar. 2008.
International Journal of Pure and Applied Mathematics Special Issue
1114
1115