SIMPLIFIED INSTRUCTIONS FOR JOLLY WITH J-CRX Porte-Cancelli... · SIMPLIFIED INSTRUCTIONS FOR JOLLY...

2
SIMPLIFIED INSTRUCTIONS FOR JOLLY WITH J-CRX 1° Connecting the motor and accessories NC NO C S AD- A*A+ S AD- A*A+ 76054R POWER CLOSE LSC OPEN LSO COM JOLLY ONE JOLLY BIG JOLLY 20 JOLLY 22 JOLLY 22S JOLLY 24 JOLLY ONE FIN MEC JOLLY BIG FIN MEC If the motor is installed facing left (as seen from inside the device), invert V with W. Respect the radius of the curve (15 cm minimum) 12 mm hole (entry of the release cable) 12 mm hole (entry of the power cable) Release knob = Power cable Electric brake = A B C D JOLLY 45 250 200 JOLLY ONE 35 250 200 JOLLY BIG 40 300 200 102 JOLLY 20 JOLLY 22-22S JOLLY 24 JOLLY ONE JOLLY ONE JOLLY BIG JOLLY BIG Ø SPRING 200 220 240 280 Ø SHAFT 48 60 76 102 = = Ø ø A B C D Spring box Shaft 12 mm vertical hole (for the brake cable) JOLLY - JOLLY ONE 12 mm front hole (for the brake cable) JOLLY BIG Foro Ø 12 IMPORTANT 10.5 mm hole - JOLLY BIG 12 mm hole (for the power cable)

Transcript of SIMPLIFIED INSTRUCTIONS FOR JOLLY WITH J-CRX Porte-Cancelli... · SIMPLIFIED INSTRUCTIONS FOR JOLLY...

SIMPLIFIED INSTRUCTIONS FOR JOLLY WITH J-CRX1° Connecting the motor and accessories

NCNOCS

AD-A*A+

SAD-A*A+

7 6 0 5 4 R

POWER

CLOSELSC

OPENLSO

COM

JOLLY ONEJOLLY BIG

JOLLY 20JOLLY 22JOLLY 22SJOLLY 24

JOLLY ONE FIN MECJOLLY BIG FIN MEC

If the motor is installed facing left (as seen from inside the device), invert V with W.

Respect the radius of the curve (15 cm minimum)12 mm hole (entry of the release cable)

12 mm hole (entry of the power cable) Release knob

=

Power cable

Electric brake =

A B C DJOLLY 45 250 200JOLLY ONE 35 250 200JOLLY BIG 40 300 200 102

JOLLY 20 JOLLY 22-22S JOLLY 24JOLLY ONE JOLLY ONE JOLLY BIG JOLLY BIG

Ø SPRING 200 220 240 280Ø SHAFT 48 60 76 102

= =

Ø

ø

A B C

D

Spring box

Shaft

12 mm vertical hole (for the brake cable) JOLLY - JOLLY ONE12 mm front hole (for the brake cable) JOLLY BIGForo Ø 12

IMPORTANT

10.5 mm hole - JOLLY BIG

12 mm hole (for the power cable)

2) Inspection of the direction of travel and power regulation

Note: invert V and W if the motor faces left (as seen from inside the device). N.B.: in this case you need to press and hold the PROG button to operate. Operation is step by step so each press of the button stops-closes-stops-opens, etc.The LEDs confirm whether configuration is correct, as described below.

a) Turn OFF DIP switches 1-2-3-4-5-6-7 and 8.

b) Turn ON DIP switch 1 (the DL1 LED will flash quickly)

c) Set the “TORQUE” trimmer at minimum

d) Press the PROG button (the green LED marked DL7 switches on and the gate opens)

e) Gradually increase the “TORQUE” only if necessary (WARNING: excessive torque could be dangerous for users)

g) After opening, the end travel is pressed by the cams and the motor stops.

h) Release the PROG button (The LED marked DL7 switches off).

i) Press and hold the PROG button again (the red LED marked DL6 switches on and the gates starts to close).

j) The end travel stops the motor when the gate is fully closed.

k) Release the PROG button (DL6 switches off).

l) Turn OFF DIP switch 1 and move to step 3.

WARNING: Make sure the electric end travels act BEFORE the gate reaches the mechanical pads of the end travel. This ensures safe operation.

3) Programming the work and pause time before automatic closure.IMPORTANT: Bridge the COM-PHOT and COM-EDGE if the safety devices are not installed. The LEDs marked DL3 and DL4 must be switched on. An LED that does not switch on means there is a faulty safety device or that there is no connection. The gate will be locked in place.a) Turn ON DIP switch 2 (the LED marked DL1 will flash slowly)b) Briefly press the PROG button (the gate opens until it meets the electrical end travel for opening). Wait for two seconds, and then press

the PROG button again to set the operating time for the gate. Once the gate has fully opened, the board counts down the time before automatic closure can begin.

NB. Automatic closure needs to be taught in even if this function is not enabled (DIP 3 switched off).c) Wait for the required amount of time before pressing the PROG button to register the waiting time. Close the gate.d) The gate is closed. DL1 has stopped flashing. The times are registered. Switch OFF DIP switch 2.

4) Programming the remote control 1) Turn ON DIP switch 1 and then turn ON DIP switch 2 => the LED marked DL1 will flash for 10 seconds.2) Press the remote control button (normally channel A) within the 10 seconds. LED 2 (green) will flash to confirm the remote control is

properly recorded.3) The code programming time is automatically reset for recording the next remote control. 4) To end programming, wait for 10 seconds or briefly press the PROG button => the LED marked DL1 will stop flashing.5) Turn OFF DIP switch 1 and turn OFF DIP switch 2.

5) Personalizing configuration

The micro-switches allow you to change the configuration

Microswitches ON Microswitches OFF

DIP3 Automatic closing activated Automatic closing not activated

DIP4 Photocells active only in closing Photocells active all the time

DIP5 Outside flashing light Inside courtesy light

DIP6 Step-by-step command The command has no effect in opening

DIP7 Safety strip monitoring TEST enabled Safety strip monitoring TEST disabled

DIP8 available available

IMPORTANT: The system must comply with all the standards and Directives currently in force.

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON

1 2 3 4 5 6 7 8

ON