SIMPLIFIED INSTRUCTIONS FOR JOLLY WITH J-CRX1° Connecting the motor and accessories
NCNOCS
AD-A*A+
SAD-A*A+
7 6 0 5 4 R
POWER
CLOSELSC
OPENLSO
COM
JOLLY ONEJOLLY BIG
JOLLY 20JOLLY 22JOLLY 22SJOLLY 24
JOLLY ONE FIN MECJOLLY BIG FIN MEC
If the motor is installed facing left (as seen from inside the device), invert V with W.
Respect the radius of the curve (15 cm minimum)12 mm hole (entry of the release cable)
12 mm hole (entry of the power cable) Release knob
=
Power cable
Electric brake =
A B C DJOLLY 45 250 200JOLLY ONE 35 250 200JOLLY BIG 40 300 200 102
JOLLY 20 JOLLY 22-22S JOLLY 24JOLLY ONE JOLLY ONE JOLLY BIG JOLLY BIG
Ø SPRING 200 220 240 280Ø SHAFT 48 60 76 102
= =
Ø
ø
A B C
D
Spring box
Shaft
12 mm vertical hole (for the brake cable) JOLLY - JOLLY ONE12 mm front hole (for the brake cable) JOLLY BIGForo Ø 12
IMPORTANT
10.5 mm hole - JOLLY BIG
12 mm hole (for the power cable)
2) Inspection of the direction of travel and power regulation
Note: invert V and W if the motor faces left (as seen from inside the device). N.B.: in this case you need to press and hold the PROG button to operate. Operation is step by step so each press of the button stops-closes-stops-opens, etc.The LEDs confirm whether configuration is correct, as described below.
a) Turn OFF DIP switches 1-2-3-4-5-6-7 and 8.
b) Turn ON DIP switch 1 (the DL1 LED will flash quickly)
c) Set the “TORQUE” trimmer at minimum
d) Press the PROG button (the green LED marked DL7 switches on and the gate opens)
e) Gradually increase the “TORQUE” only if necessary (WARNING: excessive torque could be dangerous for users)
g) After opening, the end travel is pressed by the cams and the motor stops.
h) Release the PROG button (The LED marked DL7 switches off).
i) Press and hold the PROG button again (the red LED marked DL6 switches on and the gates starts to close).
j) The end travel stops the motor when the gate is fully closed.
k) Release the PROG button (DL6 switches off).
l) Turn OFF DIP switch 1 and move to step 3.
WARNING: Make sure the electric end travels act BEFORE the gate reaches the mechanical pads of the end travel. This ensures safe operation.
3) Programming the work and pause time before automatic closure.IMPORTANT: Bridge the COM-PHOT and COM-EDGE if the safety devices are not installed. The LEDs marked DL3 and DL4 must be switched on. An LED that does not switch on means there is a faulty safety device or that there is no connection. The gate will be locked in place.a) Turn ON DIP switch 2 (the LED marked DL1 will flash slowly)b) Briefly press the PROG button (the gate opens until it meets the electrical end travel for opening). Wait for two seconds, and then press
the PROG button again to set the operating time for the gate. Once the gate has fully opened, the board counts down the time before automatic closure can begin.
NB. Automatic closure needs to be taught in even if this function is not enabled (DIP 3 switched off).c) Wait for the required amount of time before pressing the PROG button to register the waiting time. Close the gate.d) The gate is closed. DL1 has stopped flashing. The times are registered. Switch OFF DIP switch 2.
4) Programming the remote control 1) Turn ON DIP switch 1 and then turn ON DIP switch 2 => the LED marked DL1 will flash for 10 seconds.2) Press the remote control button (normally channel A) within the 10 seconds. LED 2 (green) will flash to confirm the remote control is
properly recorded.3) The code programming time is automatically reset for recording the next remote control. 4) To end programming, wait for 10 seconds or briefly press the PROG button => the LED marked DL1 will stop flashing.5) Turn OFF DIP switch 1 and turn OFF DIP switch 2.
5) Personalizing configuration
The micro-switches allow you to change the configuration
Microswitches ON Microswitches OFF
DIP3 Automatic closing activated Automatic closing not activated
DIP4 Photocells active only in closing Photocells active all the time
DIP5 Outside flashing light Inside courtesy light
DIP6 Step-by-step command The command has no effect in opening
DIP7 Safety strip monitoring TEST enabled Safety strip monitoring TEST disabled
DIP8 available available
IMPORTANT: The system must comply with all the standards and Directives currently in force.
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON