DB2 Developer Workbench, Part 3: Developer Workbench and XML
SimDesignerâ„¢ Workbench Edition - MSC Software
Transcript of SimDesignerâ„¢ Workbench Edition - MSC Software
SimDesigner™
Workbench Edition for CATIA
Release Guide
SD*R2*Z*CV5R17*Z*DC-REL
Corporate
MSC.Software Corporation
2 MacArthur Place
Santa Ana, CA 92707 USA
Telephone: (800) 345-2078
Fax: (714) 784-4056
Europe
MSC.Software GmbH
Am Moosfeld 13
81829 Munich, Germany
Telephone: (49) (89) 43 19 87 0
Fax: (49) (89) 43 61 71 6
Asia Pacific
MSC.Software Japan Ltd.
Shinjuku First West 8F
23-7 Nishi Shinjuku
1-Chome, Shinjuku-Ku
Tokyo 160-0023, JAPAN
Telephone: (81) (3)-6911-1200
Fax: (81) (3)-6911-1201
www.mscsoftware.com
DISCLAIMER
MSC.Software Corporation reserves the right to make changes in specifications and other
information contained in this document without prior notice.
The concepts, methods, and examples presented in this text are for illustrative and
educational purposes only, and are not intended to be exhaustive or to apply to any particular
engineering problem or design. MSC.Software Corporation assumes no liability or
responsibility to any person or company for direct or indirect damages resulting from the use
of any information contained herein.
User Documentation: Copyright 2007 MSC.Software Corporation. Printed in U.S.A. All
Rights Reserved.
This notice shall be marked on any reproduction of this documentation, in whole or in part.
Any reproduction or distribution of this document, in whole or in part, without the prior
written consent of MSC.Software Corporation is prohibited.
The MSC.Software logo, Adams, Marc, MD Nastran, MSC, MSC Nastran, SimDesigner,
SimEnterprise, SimManager and SimXpert are trademarks or registered trademarks of
MSC.Software Corporation or its subsidiaries in the United States and/or other countries.
NASTRAN is a registered trademark of NASA. FLEXlm is a registered trademark of Macrovision
Corporation. CATIA is a registered trademark of Dassault Systemes S.A. Windows is a
registered trademark of Microsoft Corporation. UNIX is a registered trademark of The Open
Group.
All other brand names, product names or trademarks belong to their respective owners.
Publication Date: June 2007
C o n t e n t s
SimDesigner for CATIA Release Guide
1Release Notes å=Requirements 6
å=Enhancements 7
è=Motion 7è=Structures 7è=Enterprise Manager 7
å=Frequently Asked Questions 8
å=Limitations 13
å=Product Training and Support 15
2Features Supported
å=Overview 18
å=SimDesigner Structures Workbench 19
è=Analysis Cases 19è=Modulation 20è=Model Manager 20è=Mesh Specifications 22è=Groups 22è=Analysis Connections 23è=Connection Properties 24è=Analysis Assembly 26è=Virtual Parts 26è=Mass Equipment 27è=Restraints 28è=Loads 28è=Sensors 31è=Results Computation 31
SimDesigner for CATIA Release Guide
==
4
è=Results Visualization 32è=Contextual Menu 34è=Contact 37è=Material 37
å=SimDesigner Nonlinear Workbench 38
è=Analysis Cases 38è=Model Manager 38è=Mesh Creation 39è=Mesh Specifications 40è=Adaptivity 40è=Analysis Assembly 40è=Virtual Parts 41è=Contact 41è=Material 42è=Mass Equipment 42è=Restraints 42è=Loads 43è=Sensors 45è=Groups 45è=Result Computation 46è=Results Visualization 46è=Contextual Menu 48
Ch. 1: Release Notes
1 Release Notes
� Requirements
� Enhancements
� Frequently Asked Questions
� Limitations
� Product Training and Support
6
Requirements
MSC SimDesigner R2 requires a minimum of CATIA V5 R17 SP1.
7EnhancementsMotion
Enhancements
The following enhancements are new for MSC SimDesigner R2:
Motion• New Point Measures command allows user to measure displacement, velocity or acceleration at
any point on geometry.
Structures• Solver upgrade to MD Nastran R2 for Structures & Nonlinear workbenches.
• Implicit Nonlinear solution method with SOL 600 of the MD Nastran is supported within the
Structures workbench.
• Isotropic Elastic Plastic Materials of the MD Nastran is supported within the Structures
workbench.
• Contact Bodies of the MD Nastran are supported within the Structures workbench.
• CASI Iterative Solver option for nonlinear simulations is now supported in the Structures and
Nonlinear workbenches.
• True Windows 64bit solver is now supported for Marc.
• Positional Control of Rigid Body motion is now supported within the Structures workbench.
Enterprise Manager• Execute SimXpert templates from SimManager for structural and motion analyses.
Enterprise Manager
8
Frequently Asked Questions
Question: Can I open CATAnalysis documents saved in previous/earlier releases of
CATIA?
Answer: Previously saved CATAnalysis databases can be opened but composite and orthotropic
properties may need to be redefined.
Question: Why are the transmitted DOF for RBE3 properties not getting exported
properly?
Answer: As of SimDesigner 2005 r3 for CATIA V5R14, the RBE3 property, or ‘smooth
property’, was enhanced to properly include transmitted degrees of freedom on the
RBE3 card. For databases created by earlier versions, you must validate the RBE3
property by double-clicking on it, re-selecting the DOF and clicking OK.
Question: I cannot get my licensing to work. What could be the problem?
Answer: Starting with the release of SimDesigner 2006 r1 for CATIA V5R16, you must
upgrade to, and use FLEXlm v10.8.0 license server tools.
Question: Why do I see negative Element IDs?
Answer: Integer values are used to store the element IDs which allows a maximum value of
2,147,483,647 - if that value is exceeded, the element IDs will be negative. It should
be noted that unassigned mesh part IDs will start after the highest assigned mesh part
IDs.
Question: Why are stress values for Shell elements different between SimDesigner for
CATIA V5 and CATIA GPS?
Answer: The values can be different because SimDesigner for CATIA V5 uses the Global axis
system while CATIA GPS uses a Local axis system.
Question: How can I perform solver-specific checks?
Answer: MD Nastran-specific checks are performed using SD Model Checker, so any elements
causing a fatal error can be pinpointed for further mesh modifications. A generic
quality check can be performed using CATIA V5 FMS.
9Frequently Asked QuestionsEnterprise Manager
Question: After I set up the loads and boundary conditions and clicked on the "Compute"
button, CATIA came back with a "Singularity detected (relative pivot too
small)". What went wrong?
Answer: Selecting “All” on “Compute” will run all the available cases in the specification tree.
And it is likely that you have a case with no Restraints defined or incomplete boundary
conditions. Delete that case and then rerun by selecting “Analysis Case Solution
Selection,” and click on the SimDesigner Case Solution you wanted to run.
Question: In SimDesigner Thermal workbench, and for shell element parts, why is the part
not being meshed and assigned with material properties?
Answer: For shell element parts, part bodies must be children of the main part in order to mesh
and assign material properties. If this is not the case, use the Change Body command
in your part file to move it.
Question: Why am I not able to compute after I export a solver input file?
Answer: The case gets updated after export. To recompute, use “Force Compute”.
Question: Why do I see different Von Mises values from the Image toolbar icon versus the
Camera icon?
Answer: The Image icon shows raw data from the external solvers - whereas the Camera icon
data is derived from a calculation done in SimDesigner.
Question: How do I modify the Scratch directory setting specified during installation?
Answer: By using the SimDesigner Storage Manager facility.
Question: How can I change the default External Storage Directory setting?
Answer: By changing the CATTemp setting in the SimDesigner environment file
(<install_dir>\v5ienv\). It can also be changed for each SimDesigner session by using the
Storage Manager facility from within SimDesigner.
Enterprise Manager
10
Question: Why doesn’t SimDesigner for CATIA V5 recognize the CATSettings' modifications
I did?
Answer: SimDesigner CATSettings are based on the default CATIA settings. To change the
settings specific to SimDesigner, modify the SimDesigner environment file
(<install_dir>\v5ienv\).
Question: When I run an MD Nastran analysis with the Gateway Analysis Manager (GAM), it
fails, why?
Answer: A common reason is the licensing - during the installation process, the auto-configuration
for GAM will pick up SimDesigner-specific versions of MD Nastran and Marc. Make
sure the correct version number is specified in the SimDesigner Solution Parameters
dialog.
Question: When the Gateway Analysis Manager services are not running, after selecting Setup
Batch, why does it take a while for the setup batch to respond with a message?
Answer: In such a case, services need to be started manually. Please refer to the SimDesigner
Installation Guide for information concerning the configuration of the Gateway Analysis
Manager.
Question: What causes batch job submission to fail with a job ID of zero?
Answer: When defining a new job, ensure that the name of the input file and its location does not
contain any spaces.
Question: How can I include multiple load cases in one bulk data file for MD Nastran?
Answer: Use the Restraint Set/LoadSet and Combined LoadSet icons available in the SimDesigner
toolbar.
Question: Does SimDesigner use the Computations and Results link seen in the Analysis
Manager spec tree?
Answer: The Computations and Results link (CATAnalysisComputations and
CATAnalysisResults file) is not relevant for SimDesigner products.
11Frequently Asked QuestionsEnterprise Manager
Question: When I look through the SimDesigner Structures Nonlinear Workbench Solution
Parameters, and click OK without changing any settings, the solution case gets
inactivated.
Answer: Click Cancel if you plan on not changing any parameters.
Question: How are the external CATAnalysis files managed in SimDesigner?
Answer: By using the Storage Manager within SimDesigner. Their location can be modified in the
scratch directory settings. An HTML browser is used for UNIX platforms and Notepad
for windows platforms.
Question: When using SimDesigner Thermal workbench and SimDesigner Structures
Nonlinear workbench, why are my images unclear?
Answer: For proper display, the mesh needs to be hidden using the contextual hide/show
command.
Question: Why can't I find the SD Temp Dependency option when I right-click on thermal
material?
Answer: You may not be in the SimDesigner Thermal workbench.
Question: Why is the scratch directory and results directory greyed out in GAM?
Answer: The scratch dir in “setup batch” is not used currently and the results directory is for
information only.
Question: Whenever I click on the “Expert Gateway” icon, sometimes I get a message: “Unable
to initialize and start GAM. Check QueMgr and RmtMgr services. Check GAM
installation.” Why?
Answer: There are two possibilities:
(a) This error message usually appears when the GAM remote manager does not respond
within a minute. In such a case, contact your system administrator to ensure speedier
network access.
(b) If it takes a while to respond back with a similar message, it is possible that the
MSCQueMgr services may not have been started.
Enterprise Manager
12
Question: After I submitted my job in batch, when I click on “Check Job”, why do I see the job
in queue for a long time?
Answer: Check if the MSCRmtMgr service is running. If not, it is normal to see this message.
Now, if you close the setup batch window and reopen it to check the job status, you may
see a message: “Unable to reach host. Check Host and configuration service”. In this case,
restart the MSCRmtMgr service. See the GAM configuration section in the Installation
Guide for details.
Question: After I submit a job, I see a “Job Failed” message when I check the status. How do
I fix this?
Answer: A log file should be available for viewing. In the GAM Setup Batch dialog, click on the
Browse button and select the stderr file for your job and then click on the View Log File
button to view the file. Based on the error messages, consult the relevant solver
documentation for resolution. Usually, it is a licensing issue - either there is no valid
license or the licensing declaration is not done properly.
Question: Where can I find information about SimDesigner for CATIA V5 online
documentation?
Answer: The SimDesigner for CATIA V5 online documentation (PDF and HTML) is located in:
<install_dir>/Documentation
Question: Sometimes, when I import large MD Nastran bulk data files, I get a “command
interrupted” and a “full memory address space condition” message and nothing is
imported. How do I import such files?
Answer: As the current buffer size is not enough to read large files, the NIFIMP_BUFFER_SIZE
variable should be increased to a higher value. This variable can be defined in the
SimDesigner environment file or as an env variable in the windows control panel.
13LimitationsEnterprise Manager
Limitations• If, during the installation of Analysis Manager 2005r8, the SimDesigner embedded MD Nastran
and Marc solvers are selected, the MD Nastran and Marc paths have to be changed afterwards to
point to the proper solver. This is done in the configuration file:
<..>\MSC.Analysis_Manager\2005r8\default\conf\host.cfg
See the Installation Guide for the correct format.
• In this release, when you export a case to a solver deck, any result attached to the solution set of
that case will be detached. If you just want to see the deck, click on the storage manager next to
the compute command and select the deck for viewing.
• In setting up the GAM configuration file, host.cfg, if "NONE" were used in place of the rc file,
then a global environment variable, MSC_LICENSE_FILE, must be set to point to the proper
MD Nastran license.
• In general, if Compute All fails to cycle through and compute on all cases, you might have to
select the uncomputed cases one by one.
• Changes to flex body animation are as follows:
• When you animate multiple flexible parts, CATIA will superimpose the color maps from the
CATAnalysis documents. You can select each color map individually and drag it to another
location.
• To ensure a constant stress range for each color in the color map during an animation, you can
impose maximum and minimum stress values on the color map in the CATAnalysis
document.
• SimDesigner session may hang during the import of an XDB file that contains 6000 or more
bar/beam elements that share the same pair of nodes.
• When exporting MD Nastran bulk data file via Gateway for MD Nastran, Beam properties,
dynamic load combinations, and restraints set combinations (i.e. PBEAML/PBEAM, DLOAD,
and SPCADD) are always written in single precision.
• In a SimDesigner Nonlinear solution case, when more than two contact bodies are initially in
contact along a common edge, the Marc solution may fail.
• In a SimDesigner Dynamic case, the displacement plot in the xy-plotter would only show the
real component. The imaginary component and the overall magnitudes would be available in
future releases.
• Animation along with simulation of a flexible body does not show any change in stress contours.
(1-49262211)
This is on AIX only for Motion Workbench.
The workaround is:
• Change window to the CATAnalysis document
• Select the import results command
• Import the transient XDB file that was created during the motion animation step.
Enterprise Manager
14
Note: The location of the transient XDB file can be found by opening the Storage Manager
command in the SimDesigner Linear Workbench. The transient XDB file will have a long
filename in the format of:
<timestamp>_<resultname>_<timestamp>.xdb
Example:
2007_01_22_11_17_19_Results_1_2007022t111854.xdb
• Animation with flexible bodies causes a hang in Motion Workbench (1-49906041)
This issue only occurs on machines with dual-processors using hyperthreading. User must kill
CATIA process – thus a potential loss of data.
There are two ways to solve this issue:
• Disable hyperthreading on your machine.
• Obtain CATIA V5 R17 Service Pack 3 plus Hotfix 19 from Saddault Systemes and install on
your machine. Then enable the CATIA environment variable
CATTMCStopMultiThreadVisu = yes.
• "Compute All" command fails to run a complete coupled thermal analysis after modification is
made to a part (1-48641401).
The workaround is:
• After modification is made to the part, first update the mesh independently. Then you can run
"Compute All."
15Product Training and SupportEnterprise Manager
Product Training and Support
The MSC Institute of Technology is a service organization chartered to provide our software customers
and other design and engineering professionals with basic and specialized training in the use of Dassault
Systemes’ and MSC.Software's MCAE software products.
Introductory, intermediate, and advanced training courses are offered at local MSC.Software offices on
a regular basis. These courses introduce the novice to theoretical and usage aspects of the software, and
expose the experienced user to more advanced features of the software. Lecture sessions are always
combined with workshops. Customer suggestions for training improvement are continually reviewed by
our professional trainers to insure that our courses are effective and up-to-date.
Our industry-experienced expert staff is available to customize our course offerings to meet your unique
training requirements. For the most effective training, the Institute also offers many of our courses at our
customers’ facilities.
The MSC Institute of Technology is headquartered at:
2 MacArthur Place
Santa Ana, CA 92707
Phone: (800) 732-7211
Fax: (714) 784-4028
For customers outside the Unites States, please contact your local MSC.Software sales office which may
be found at www.mscsoftware.com.
The Institute maintains state-of-the-art classroom facilities and individual computer graphics laboratories
at training centers throughout the world. All of our courses emphasize hands-on computer laboratory
work to facilitate skills development.
We specialize in customized training based on our evaluation of your design and simulation processes,
which yields courses that are geared to your business.
In addition to traditional instructor-led classes, we also offer video and DVD courses, interactive
multimedia training, web-based training, and a specialized instructor's program.
For detailed course descriptions, schedule information, and registration call, in the USA, the Training
Specialist at (800) 732-7211 or visit www.mscsoftware.com.
Enterprise Manager
16
Ch. 2: Features Supported
2 Features Supported
� Overview
� SimDesigner Structures Workbench
� SimDesigner Nonlinear Workbench
18
Overview
This appendix lists the features supported in SimDesigner Structures Workbench, SimDesigner
Nonlinear Workbench and the corresponding Enterprise Gateway Products.
This list is an extension of the list found in the “Before you begin” section of the CATIA V5 GPS
documentation.
For SimDesigner Enterprise products, note the following:
P - GPS is required
A - GAS is required
E - EST is required
Refer to the CATIA V5 analysis documentation for more information about GPS, GAS and EST.
GWx functionality shown here is applicable within the context of GPS and SimDesigner only.
CATIA V5 license required to run the listed command
Some of the functionalities in these commands are available only if you have previously
installed the EST product - for more details, see the documented task itself.
19SimDesigner Structures WorkbenchAnalysis Cases
SimDesigner Structures Workbench
Analysis Cases
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
Static Case
Static
Constrained
Case
SD Static
Case
P P P P
Frequency
Case
SD
Frequency
Case
P P P P
Buckling
Case
SD
Buckling
Case
P P P
SD Load
Stiffened
Frequency
Case
P P
Combined
Case
Pre-
processing
Case
Modulation
20
Modulation
Model Manager
Solution
Case
Envelop
Case
P P
Harmonic
Dynamic
Response
Transient
Dynamic
Response
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
White
Noise
Modulation
Import
Frequency
Modulation
Import
Time
Modulation
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
3D
MeshPart
P P P P
Commands CATIA V5 SimDesigner
21SimDesigner Structures WorkbenchModel Manager
2D
MeshPart
P P P P
1D
MeshPart
P P P P
Local Mesh
Sizes
P P P P
Local Mesh
Sags
P P P P
Element
Type
P P P P
3D Property P P P P
2D Property P P P P
Imported
Composite
Property
P,E P,E P,E
1D Property P P P P
Imported
Beam
Property
P P P P
Mapping
Property
P P P P
Check the
Model
P P P P
User
Material
P P P P
Commands CATIA V5 SimDesigner
Mesh Specifications
22
Mesh Specifications
Groups
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
Adaptivity
Boxes
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
Group
Points
P,E P,E P,E
Group
Lines
P,E P,E P,E
Group
Surfaces
P,E P,E P,E
Group
Bodies
P,E P,E P,E
Box Group P,E P,E P,E
Sphere
Group
P,E P,E P,E
Point Group
by
Neighbor-
hood
P,E P,E P,E
Line Group
by
Neighbor-
hood
P,E P,E P,E
23SimDesigner Structures WorkbenchAnalysis Connections
Analysis Connections
Surface
Group by
Neighbor-
hood
P,E P,E P,E
Line Group
by
Boundary
Surface
Group by
Boundary
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
General
Connection
s
P, A P, A P, A
Point
Analysis
Connection
s
P, A P, A P, A
Point
Analysis
Connection
s within one
part
P, A P, A P, A
Line
Analysis
Connection
s
P, A P, A P, A
Line
Analysis
Connection
s within one
part
P, A P, A P, A
Commands CATIA V5 SimDesigner
Connection Properties
24
Connection Properties
Surface
Analysis
Connection
s
P, A P, A P, A
Surface
Analysis
Connection
s within one
part
P, A P, A P, A
Point to
Point
Analysis
Connection
s
P, A P, A P, A
Point
Analysis
Interface
P, A P, A P, A
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
Fastened
Connection
Property
P, A P, A P, A P, A
Fastened
Spring
Connection
Property
P, A P, A P, A
Slider
Connection
Property
P, A P, A P, A P, A
Contact
Connection
Property
P, A P, A P, A P, A
Commands CATIA V5 SimDesigner
25SimDesigner Structures WorkbenchConnection Properties
Pressure
Fitting
Connection
Property
Bolt
Tightening
Connection
Property
Virtual
Rigid Bolt
Tightening
Connection
Property
Virtual
Spring Bolt
Tightening
Connection
Property
Rigid
Connection
Property
P, A P, A P, A P, A
Smooth
Connection
Property
P, A P, A P, A P, A
User-
Defined
Distant
Connection
Properties
P, A P, A P, A P, A
Spot
Welding
Connection
Properties
P, A P, A P, A P, A
Seam
Welding
Connection
Properties
P, A P, A P, A P, A
Commands CATIA V5 SimDesigner
Analysis Assembly
26
Analysis Assembly
Virtual Parts
Surface
Welding
Connection
Properties
P, A P, A P, A
Nodes to
Nodes
Analysis
Connection
s
P, A P, A P, A
Node
Analysis
Interface
P, A P, A P, A
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
Analysis
Assembly
2D Viewer
P,A
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
Rigid
Virtual
Parts
P P P P
Smooth
Virtual
Parts
P P P P
Contact
Virtual
Parts
P P P P
Commands CATIA V5 SimDesigner
27SimDesigner Structures WorkbenchMass Equipment
Mass Equipment
Rigid
Spring
Virtual
Parts
P P P P
Spring
Smooth
Virtual
Parts
P P P P
Periodicity
Conditions
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
Distributed
Mass
P P P P
Line Mass
Densities
P P P P
Surface
Mass
Densities
P P P P
Distributed
Inertia
P,E P,E P,E
Combined
Masses
P,E P,E
Assembled
Masses
P,A P,A
Commands CATIA V5 SimDesigner
Restraints
28
Restraints
Loads
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
Clamps P P P P
Surface
Sliders
P P P P
Ball Joins P P P P
Sliders P P P P
Pivots P P P P
Sliding
Pivots
P P P P
User-
defined
Restraints
P P P P
Iso-static
Restraints
P P P P
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
Pressure P P P P
29SimDesigner Structures WorkbenchLoads
Distributed
Force
P P P P
Moment P P P P
Bearing
Load
P,E P,E P,E P,E
Importing
Forces
P,E P,E P,E P,E
Importing
Moments
P,E P,E P,E P,E
Line Force
Density
P P P P
Surface
Force
Density
P P P P
Volume
Force
Density
P P P P
Force
Density
P,E P,E P,E P,E
Acceleratio
n
P P P P
Rotation
Force
P P P P
Enforced
Displaceme
nt
P P P P
Temper-
ature Field
P,E P,E P,E P,E
Commands CATIA V5 SimDesigner
Loads
30
Temper-
ature Field
from
Thermal
Solution
P,E P,E P,E
Combined
Loads
P,E P,E
Assembled
Loads
P,A P,A
SD
Restraint
Set
P P
SD Load
Set
P P P
SD
Combined
Load Set
P P
SD
Ambient
Temper-
ature
P P
SD
Reference
Temperatur
e Field
P P
Analysis
Assembly
2D Viewer
P,A
Commands CATIA V5 SimDesigner
31SimDesigner Structures WorkbenchSensors
Sensors
Results Computation
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
Create
Global
Sensors
P P P P
Create
Local
Sensors
P P P
Create
Reaction
Sensors
P P P P
Applied
Load
Sensors
Internal
Load
Sensors
Multi Load
Sensors
Inertia
Sensors
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
External
Storage
External
Storage
Clean-up
Results Visualization
32
Results Visualization
Temporary
External
Storage
Computing P
Computing
with
Adaptivity
Computing
using Batch
SD Setup
Batch
P P
SD Storage
Manager
P
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
Deform-
ation
P P P P
Von Mises
Stresses
P P P
Displaceme
nts
P P P
Principal
Stresses
P P P
Commands CATIA V5 SimDesigner
33SimDesigner Structures WorkbenchResults Visualization
Precisions P P
Generate
Reporting
P P P
Generate
Advanced
Reporting
P,E P,E P,E
History of
Computatio
n
SD XY Plot P P P
Elfini
Solver Log
Animate
Image
P P P P
Cut Plane
Analysis
P P P P
Amplificat-
ion
Magnitude
P P P
Extrema
Detection
P P P
Information P P P
Images
Layout
P,E P,E P,E P,E
Simplified
Representat
ion
P,E P,E P,E P,E
Commands CATIA V5 SimDesigner
Contextual Menu
34
Contextual Menu
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
Update
Group
P P P P
Update All
Groups
P P P P
Analyze
Group
P P P P
Local 2D
Property
P,E P,E P,E P,E
Local 1D
Property
P,E P,E P,E P,E
Local
Adaptivity
Generate
Mapping
File
P,E P,E P,E P,E
Create
Preprocessing Set
Add Solution
35SimDesigner Structures WorkbenchContextual Menu
P P P P
P,E P,E P,E P,E
P,E P,E P,E P,E
P P P P
P P P P
Mesh
Visualizat-
ion
P P P P
Commands CATIA V5 SimDesigner
Contextual Menu
36
Restraint
Visualizat-
ion on mesh
P P P P
Pressure
Visualizat-
ion on mesh
P P P P
Masses
Visualization on
mesh
Generate
Image
P P P P
Save as
New
Template
P,E P,E P,E
Report P,E P,E P,E
Export Data P,E P,E P,E
Generate
2D Display
for Sensor
P P P P
Generate
2D Display
for
Modulation
Generate
2D Display
for dynamic
response
solutions
Commands CATIA V5 SimDesigner
37SimDesigner Structures WorkbenchContact
Contact
Material
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
Contact P P P
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures
Workbench
GWN GWM GWS
P P
Analysis Cases
38
SimDesigner Nonlinear Workbench
Analysis Cases
Model Manager
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Nonlinear
Workbench
GWM
Analysis Case GWX functionalities shown here are applicable within the context of
SDX
SD Nonlinear
Case
P P
Large displacement and large strain problems can be computed only with GPS.
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Nonlinear
Workbench
GWM
3D Mesh Part P P
2D Mesh Part P P
Local Mesh
Sizes
P P
Local Mesh Sags P P
Element Type P P
3D Property P P
39SimDesigner Nonlinear WorkbenchMesh Creation
Mesh Creation
2D Property P P
Beam Property P P
Check the Mesh
(Body)
P P
Check the Mesh (
Connections)
P P
Check the Mesh (
others)
P P
User Material P P
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Nonlinear
Workbench
GWM
3D Mesh Part P P
2D Mesh Part P P
1D Mesh Part
Commands CATIA V5 SimDesigner
Mesh Specifications
40
Mesh Specifications
Adaptivity
Analysis Assembly
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Nonlinear
Workbench
GWM
Local Mesh
Sizes
P P
Local Mesh Sags P P
Element Type P P
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Nonlinear
Workbench
GWM
Adaptivity
Boxes
P P
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Nonlinear
Workbench
GWM
Analysis
Assembly 2D
Viewer
P,A
41SimDesigner Nonlinear WorkbenchVirtual Parts
Virtual Parts
Contact
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Nonlinear
Workbench
GWM
Rigid Virtual
Parts
P P
Smooth Virtual
Parts
P P
Contact Virtual
Parts
Rigid Spring
Virtual parts
P P
P P
Spring smooth
virtual parts
P P
Periodicity
Conditions
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Nonlinear
Workbench
GWM
Contact P P, Nonlinear
Workbench
Material
42
Material
Mass Equipment
Restraints
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Nonlinear
Workbench
GWM
P P, Nonlinear
Workbench
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Nonlinear
Workbench
GWM
Distributed Mass
Line Mass
Densities
Surface Mass
Densities
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Nonlinear
Workbench
GWM
Clamps P P
Surface Sliders P P
43SimDesigner Nonlinear WorkbenchLoads
Loads
Ball Joins P P
Sliders P P
Pivot P P
Sliding Pivots P P
Advanced
Restraints
P P
Iso- Static
Restraints
P P
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Nonlinear
Workbench
GWM
Pressure P P
Distributed
Forces
P P
Moment P P
Bearing Load P,E P,E
Commands CATIA V5 SimDesigner
Loads
44
Importing Forces P,E P,E
Importing
Moments
P,E P,E
Line Force
Density
P P
Surface Force
Density
P P
Volume Force
Density
P P
Accelaration P P
Rotation Force P P
Enforced
Displacement
P P
Temperature
Field
P,E P,E
Pre-Stress
P, Nonlinear
Workbench
P, Nonlinear
Workbench
Reference
Temperature
Field
P P
Images Layout P P
Commands CATIA V5 SimDesigner
45SimDesigner Nonlinear WorkbenchSensors
Sensors
Groups
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Nonlinear
Workbench
GWM
Create Sensors
(static Analysis
Case)
Create Sensors (
Frequency
Analysis Case)
Create Sensors (
Buckling Case)
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Nonlinear
Workbench
GWM
Group Points P,E P,E
Group Lines P,E P,E
Group Surfaces P,E P,E
Group Bodies P,E P,E
Result Computation
46
Result Computation
Results Visualization
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Nonlinear
Workbench
GWM
Specify External
Storage
Clear External
Storage
Temporary Data
Directory
Computing
Object Sets
P
Managing
Adaptivity
Use a Batch
SD Setup Batch P
SD Storage
Manager
P
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Structures Nonlinear
Workbench
GWM
Generate Image P P
47SimDesigner Nonlinear WorkbenchResults Visualization
Deformation P P
Von Mises
Stresses
P P
Displacements P P
Principal stresses P P
Precisions
Generate Report P P
Generate
Advanced
Reporting
P,E P,E
Historic of
Computation
SD XY Plot P P
Animate Image P P
Cut Plane
Analysis
P P
Amplification
Magnitude
P P
Commands CATIA V5 SimDesigner
Contextual Menu
48
Contextual Menu
Extrema
Detection
P P
Information P P
Commands CATIA V5 SimDesigner
GP1 GPS EST GAS GDY Nonlinear
Workbench
GWM
Extrema
Detection
P P
Information P P
Images Layout P,E P,E
Commands CATIA V5 SimDesigner