Silent Generators Powered by - Gaston KenyaGP350S 350 280 400 320 2606C-E13TAG2 LSA47.2VS1...

4
Silent Generators Powered by Generator comes ready to run on delivery, just install, fill with fuel, connect the power cable and the unit is ready to go!!! • 10KVA -1500KVA • Perkins Engine • Deep Sea Digital Controller • Leroy Somer Alternator • Standard 8 Hours Integral Fuel Tank • In line Circuit Breaker • Starter Battery

Transcript of Silent Generators Powered by - Gaston KenyaGP350S 350 280 400 320 2606C-E13TAG2 LSA47.2VS1...

Page 1: Silent Generators Powered by - Gaston KenyaGP350S 350 280 400 320 2606C-E13TAG2 LSA47.2VS1 4400*1430*2450 4260 880 GP400S 400 320 440 352 2206C-E13TAG3 LSA47.2S4 4400*1430*245 0 4260

Silent Generators Powered by

Generator comes ready to run on delivery, just install, fill with

fuel, connect the power cable and the unit is ready to go!!!

• 10KVA -1500KVA • Perkins Engine • Deep Sea Digital Controller

• Leroy Somer Alternator • Standard 8 Hours Integral Fuel Tank

• In line Circuit Breaker • Starter Battery

Page 2: Silent Generators Powered by - Gaston KenyaGP350S 350 280 400 320 2606C-E13TAG2 LSA47.2VS1 4400*1430*2450 4260 880 GP400S 400 320 440 352 2206C-E13TAG3 LSA47.2S4 4400*1430*245 0 4260

Silent Generators Powered by

MODEL

PRIME

POWER

STANDBY POWER

SOUNDPROOF SETS

KVA KW KVA KW ENGINE ALTERNATOR L*W*H�MM� WEIGHT�KG� TANK�L�

GP10S 10 8 102 83 403D-11G LSA40VS1 1950*740*1115 558 75

GP13S 13 10 14 11 403D-15G LSA40VS2 1950*750*1115 688 75

GP15S 15 12 17 13.6 403A-15G2 LSA40S3 1950*740*1115 695 75

GP20S 20 16 22 17.6 404D-22G 404D-22G 2100*740*1115 752 55

GP30S 30 24 33 26 1103A-33G LSA42.3VS3 2400*1030*1515 1203 157

GP45S 45 36 50 40 1103A-33TG1 LSA42.3M7 2600*1130*1615 1354 200

GP60S 60 48 66 52 1103A-33TG2 LSA42.3L9 2600*1130*1615 1354 200

GP80S 80 64 88 70 1104A-44TG2 LSA43.2L8 2800*1130*1655 1610 280

GP100S 100 80 110 88 1104C-44TAG2 LSA44.2VS45 3200*1130*1715 1860 300

GP135S 135 110 150 120 1106A-70TAG1 LSA44.2S75 3200*1130*1715 2032 300

GP150S 150 120 165 132 1106A-70TAG2 LSA44.2M95 3400*1130*1470 2032 425

GP180S 180 144 195 156 1106A-70TG1 LSA46.2M3 3400*1130*1915 2300 425

GP200S 200 160 220 176 1506A-E88TAG1 LSA46.2M5 3400*1130*1915 2340 425

GP225S 225 180 250 200 1506-A-E88TAG2 LSA46.2L6 3600*1330*2065 2530 500

GP250S 250 200 275 220 1306C-E87TAG6 LSA46.2L6 3600*1330*2065 2530 500

GP300S 300 240 330 264 1606A-E93TAG5 LSA46.2VL12 4400*1430*2250 3430 700

GP350S 350 280 400 320 2606C-E13TAG2 LSA47.2VS1 4400*1430*2450 4260 880

GP400S 400 320 440 352 2206C-E13TAG3 LSA47.2S4 4400*1430*2450 4260 880

GP450S 450 360 500 400 2506C-E15TAG1 LSA47.2S5 4600*1430*2515 4770 970

GP500S 500 400 550 440 2506C-E15TAG2 LSA47.2M7 4600*1430*2515 4770 970

GP600S 600 480 660 528 2806-E18TAG1A LSA47.2L9 4800*1830*2515 6050 970

GP650S 650 520 715 572 2806A-E18TAG2 LSA49.1S4 4800*1830*2515 6150 970

GP725S 725 580 800 640 4006-23TAG3A LSA49.1M65 20'GP*20'GP*20'GP 8100 N/A

GP800S 800 640 880 704 4006-23TAG3A LSA49.1M75 20'GP*20'GP*20'GP 8150 N/A

GP900S 900 720 990 729 4008TAG2 LSA49.1L10 20'GP*20'GP*20'GP 9800 N/A

GP1000S 1000 800 1100 880 4008TAG2 LSA49.1L11 20'GP*20'GP*20'GP 9820 N/A

GP1250S 1250 1000 1375 1100 4012-46TWG2A LSA50.2M6 40'GP*40'GP*40'GP 12900 N/A

GP1500S 1500 1200 1650 1320 4012-46TAG2A LSA450.2L8 40'GP*40'GP*40'GP 13000 N/A

Page 3: Silent Generators Powered by - Gaston KenyaGP350S 350 280 400 320 2606C-E13TAG2 LSA47.2VS1 4400*1430*2450 4260 880 GP400S 400 320 440 352 2206C-E13TAG3 LSA47.2S4 4400*1430*245 0 4260

Silent Generators Powered by

AUTOMATIC CHANGEOVER PANELS AVAILABLE FROM 25A TO 2500A

Gaston power transfers switch ensures

that:

GENUINE SERVICES AND MAINTENANCE PARTS ARE AVAILABLE FROM GASTON KENYA LTD

The mains voltage is monitored for

over-voltage, phase failiure and phase

sequence

The generator comes on automatically

incase of power failure

The generator goes off after the mains

return.

Inspect the generator for any leakage or

loose connections

Change the oil and the filters

Clean the system

Top up the generator coolant

Check and fill up the battery electrolyte

Advice the client on the status of the

generator

We offer annual service contracts.

At every service our engineers:

Well ventilated room

Strong reinforced concrete base

Proper cable sizing, glanding and

lugging

Exhaust extension from the generator

room

Proper earthing of the generator

Noise levels: open or silent generator

requirements

GENERATOR SIZING, INSTALLATION AND TESTING

Gaston Kenya Ltd. specializes in Generator

installation works. When installing a

generator, we put into consideration:

Page 4: Silent Generators Powered by - Gaston KenyaGP350S 350 280 400 320 2606C-E13TAG2 LSA47.2VS1 4400*1430*2450 4260 880 GP400S 400 320 440 352 2206C-E13TAG3 LSA47.2S4 4400*1430*245 0 4260

SILENT

GENERATORS

POWERED

BY

GASTON KENYA LTD.

020 2463753/4, 0722 816 212, 0723 851 833,

0700 429 556, 0700 429 314

[email protected]

www.gastonkenya.com

Gaston Plaza, Gaston Lane, Garden Estate Rd.