Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization...

44
Signal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Transcript of Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization...

Page 1: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Signal Conditioning and Linearization of RTD

Sensors Collin Wells

Texas Instruments

HPA Precision Linear Applications

9/24/11

Page 2: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Introduction

• Primary Support

– 4-20mA Loop Drivers (XTRXXX)

– Gamma Buffers (BUFXXXXX)

• Other Support

– Temperature Sensors (TMP)

– IR Temperature Sensors (TMP006)

– OPA Stability

– Instrument Amplifiers

• Applications (Other)

– Industrial – Programmable Logic Controllers (PLC)

– RTD

– Reference Designs

Page 3: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Contents

•RTD Overview

•RTD Nonlinearity

•Analog Linearization

•Digital Acquisition and Linearization

Page 4: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

What is an RTD?

• Resistive Temperature Detector

• Sensor with a predictable resistance vs. temperature

• Measure the resistance and calculate temperature based on the

Resistance vs. Temperature characteristics of the RTD material

200 100 0 100 200 300 400 500 600 700 8000

40

80

120

160

200

240

280

320

360

400

RTD Resistance vs. Temperature

Temperature (C)

Res

ista

nce

(O

hm

s)

RTD (Temp)PT100

α = 0.00385

RTDR

Page 5: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

How does an RTD work?

• The product n*u decreases over temperature, therefore resistance

increases over temperature (PTC)

Resistance R L

A

Resistivity p1

e n

• Linear Model of Conductor Resistivity Change vs. Temperature

• L = Wire Length

• A = Wire Area

• e = Electron Charge

(1.6e-19 Coulombs)

• n = Electron Density

• u = Electron Mobility

t( ) 0 1 t t0

Page 6: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

What is an RTD made of?

• Platinum (pt)

• Nickel (Ni)

• Copper (Cu)

Metal

Resistivity

(Ohm/CMF)

Gold (Au) 13

Silver (Ag) 8.8

Copper (Cu) 9.26

Platinum (Pt) 59

Tungsten (W) 30

Nickel (Ni) 36

•Have relatively linear change in resistance over temp

•Have high resistivity allowing for smaller dimensions

•Either Thin-Film or Wire-Wound

*Images from RDF Corp

Page 7: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

How Accurate is an RTD? • Absolute accuracy is “Class” dependant - defined by DIN-IEC 60751. Allows for easy

interchangeability of field sensors

• Repeatability usually very good, allows for individual sensor calibration

• Long-Term Drift usually <0.1C/year, can get as low as 0.0025C/year

*AAA (1/10DIN) is not included in the DIN-IEC-60751 spec but is an industry accepted tolerance class for high-performance

measurements

**Manufacturers may choose to guarantee operation over a wider temperature range than the DIN-IEC60751 provides

Tolerance Class

(DIN-IEC 60751)

**Temperature Range of

Validity

Tolerance Values (C)

Resistance at

0C (Ohms)

Error

at

100C

(C)

Error over

Wire-

Wound

Range (C)

Wire-

Wound Thin-Film

*AAA (1/10 DIN) 0 - +100 0 - +100 +/-(0.03 + 0.0005*t) 100 +/- 0.012 0.08 0.08

AA (1/3DIN) -50 - +250 0 - +150 +/-(0.1 + 0.0017*t) 100 +/- 0.04 0.27 0.525

A -100 - +450 -30 - +300 +/-(0.15 + 0.002*t) 100 +/- 0.06 0.35 1.05

B -196 - +600 -50 - +500 +/-(0.3 + 0.005*t) 100 +/- 0.12 0.8 3.3

C -196 - +600 -50 - +600 +/-(0.6 + 0.01*t) 100 +/- 0.24 1.6 6.6

Page 8: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Why use an RTD?

Table Comparing Advantages and Disadvantages of Temp Sensors

Page 9: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

How to Measure an RTD Resistance?

• Use a…….

Wheatstone Bridge or Current Source

Vmeas Vsource

RRTD

RA RRTD

1

2

MEASV

+-

RTDR

AR

AR

AR

+Vsource

MEASV+

-SOURCEIRTDR

Vmeas Isource RRTD

RRTD

Vmeas

Isource

Vmeas Isource RRTD

RRT D

2 RA Vmeas RA Vsource

Vsource 2 Vmeas

Page 10: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Note on Non-Linear Output of Bridge

Vmeas Vsource

RRTD

RA RRTD

1

2

Denominator causes a non-linear

output even for a linear sensor

MEASV

+-

RTD

100

100

100

+Vsource

ΔRTD = 50Ohms

Input resistance (ohms)

100.00 112.50 125.00 137.50 150.00

Voltage (

V)

0.00

125.00m

250.00m

375.00m

500.00m

Page 11: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Simple Current Source / Sink Circuits

+5V

+5V

1u

1u 10u

Vin

Temp

GND

Vout

Trim

U8 REF5025

Rset 25k

RTD 100

I_Out-

++

U9 OPA340

100.05uA

+5V

+5V

Q1

Rset 10k

RTD 100R3 40k

R4 10k

I_Out

+

-

+

U1 OPA333

100uA

+5V

+5VR8 40k

R9 10k

R12 10k

RTD 100

AM

5

Q2+

-

+

U2 OPA333

100uA

REF200

V2 2.5

V3 2.5

R1 1

0k

R2 200k

+

Vdiff -49.85m

+Vcm 2.5 R

3 4

9.9

C1 1

00n

+

+

-R1

R1

R2

INA326T1 INA326T

I_Out

R4 1

00

100uA

Page 12: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

RTD Types and Their Parasitic Lead Resistances

RTDR

LR

LR

Red

White

RTDR

LR

LR

LR

Red

Red

White

RTDR

LR

LR

LR

LR

Red

Red

White

WhiteRTDR

LR

LR

LR

LR

Red

White

Blue

Blue

2-Wire 3-Wire

4-Wire 2-Wire with

Compensating

Loop

Page 13: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

2-Wire Measurements

SOURCEMEASV+

-IRTDR

LR

LR

Vmeas Isource RRTD Isource 2 RL

Error Isource 2 RL

MEASV+-

RTDR

LR

LR

AR

A

R

A

R

+Vsource

Vmeas Vsource

RRTD 2RL

RA RRTD 2.RL

1

2

Error Vsource

2 RA RL

RA RRTD RA 2 RL RRTD

Page 14: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

3-Wire Measurements

MEASV+

-

SOURCE1I

RTDR

LR

LR

SOURCE2I

LR

MEASV

+-

RTDR

LR

LR

AR

AR

ARLR

+Vsource

Vmeas Vsource

RRTD RL

RA RRTD 2 RL

1

2

Error Vsource

RL RA RRTD

RA RRTD RA 2 RL RRTD

+

-

+ -

Isource1 Isource2 I

Vmeas I RL I RRTD 2 I( ) RL I RRTD 3 I RL

Vmeas I RL 2 I( ) RL 3 I RL

Vmeas Vmeas I RRTD 3 I RL 3 I RL I RRTD

Error = 0 as long as Isource1 = Isource2 and RL are equal

Page 15: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

4-Wire Measurements

MEASV+

-IRTDR

LR

LRLR

LR

Vmeas Isource RRTD

System Errors reduced to

measurement circuit accuracy Error Vsource

RL 2.0 RA 2.0 RRTD

RA RRTD RA 4.0 RL RRTD

MEASV

+-

RTDRLR

LR

AR

AR

AR

LR

+Vsource

LR

VmeasRA Vsource RA RRT D

2 RA2

6 RA RL 2 RRT D RA 4 RL2

2 RRT D RL

Page 16: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Self-Heating Errors of RTD

• Typically 2.5mW/C – 60mW/C

• Set excitation level so self-heating error is <10% of the total error

budget

1 105

1 104

1 103

0.01

1 107

1 106

1 105

1 104

1 103

0.01

0.1

1

10

Self-Heating Error of an RTD vs. Exciation Current

Current (A)

Tem

per

atu

re (

C)

Errorselfheat200nI( )

Errorselfheat0 I( )

Errorselfheat850 I( )

I

Page 17: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

RTD Resistance vs Temperature Callendar-Van Dusen Equations

IEC 60751 PT-100 RTD (α = 0.00385)

Equation Constants for

R0 100

A 3.9083103

B 5.775 107

C 4.183 1012

For (T > 0) : RTD T( ) R0 1 A T B T2

For (T < 0) : RTD T( ) R0 1 A T B T2 C T

3 T 100( )

200 100 0 100 200 300 400 500 600 700 8000

40

80

120

160

200

240

280

320

360

400

RTD Resistance vs. Temperature

Temperature (C)

Res

ista

nce

(O

hm

s)

RTD (T)

Page 18: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

RTD Nonlinearity

200 95 10 115 220 325 430 535 640 745 8500

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

0

10

20

30

40

50

Nonlinearity and Temperature Error vs. Temperature

Temperature (C)

Tem

per

atu

re N

on

lin

eari

ty (

%F

SR

)

Tem

per

atu

re E

rro

r (C

)

200 95 10 115 220 325 430 535 640 745 8500

40

80

120

160

200

240

280

320

360

400

RTD Resistance vs. Temperature

Temperature (C)

Res

ista

nce

(O

hm

s)

RTD Temp( )

R LINFIT Temp( )

Linear fit between the two end-points

shows the Full-Scale nonlinearity

Nonlinearity = 4.5%

Temperature Error > 45C

Page 19: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

RTD Nonlinearity

200 95 10 115 220 325 430 535 640 745 8500

45

90

135

180

225

270

315

360

405

450

RTD Resistance vs. Temperature

Temperature (C)

Res

ista

nce

(O

hm

s)

RTD Temp( )

RTDlinear(Temp)

For (T > 0) : RTD T( ) R0 1 A T B T2

For (T < 0) : RTD T( ) R0 1 A T B T2 C T

3 T 100( )

R0 100

A 3.9083103

B 5.775 107

C 4.183 1012

RTDlinear T( ) R0 1 A T( )

B and C terms are negative so

2nd and 3rd order effects

decrease the sensor output

over the sensor span.

Page 20: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Measurement Nonlinearity

MEASV+

-SOURCEIRTDR

Vmeas Isource RRTD

0 80 160 240 320 400 480 560 640 720 8000.01

0.0135

0.017

0.0205

0.024

0.0275

0.031

0.0345

0.038

0.0415

0.045

RTD Sensor Output vs. Temperature (Isource = 100uA)

Temperature (C)

Vo

ltag

e (V

)

VRTD (Temp)

V RTD_linear (Temp)

Page 21: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Correcting for Non-Linearity

MEASV+

-SOURCEIRTDR

Vmeas Isource RRTD

Sensor output decreases over span? Compensate by increasing excitation over span!

MEASV+

-SOURCEI RTDR

Vmeas (Isource RRTD

CORRECTIONI

+ Icorrection

Icorrection = gain*Vmeas+Offset

0 80 160 240 320 400 480 560 640 720 8000.01

0.0135

0.017

0.0205

0.024

0.0275

0.031

0.0345

0.038

0.0415

0.045

RTD Sensor Output vs. Temperature (Isource = 100uA)

Temperature (C)

Volt

age

(V)

VRTD (Temp)

V RTD_linear (Temp)

Increasing excitation source over measurement

span produces linear sensor output

Page 22: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Correcting for Non-linearity Isource 0.0005

VRTD T( ) RTD T( ) Isource

VRTD_linear T( ) RTDlinear T( ) Isource

Isource_correction T( ) Isource

VRTD_linear T( ) VRTD T( ) RTD T( )

VRTD_correction T( ) RTDlinear T( ) Isource_correction T( )

VRTD_linearized T( ) Isource_correction T( ) RTD T( )

200 100 0 100 200 300 400 500 600 700 8000

0.025

0.05

0.075

0.1

0.125

0.15

0.175

0.2

0.225

0.25

RTD Resistance vs. Temperature

Temperature (C)

Volt

age

(V) VRTD Temp( )

VRTD_correction Temp( )

VRTD_linearized Temp( )

Temp

Isource 0.0005

VRTD T( ) RTD T( ) Isource

VRTD_linear T( ) RTDlinear T( ) Isource

Isource_correction T( ) Isource

VRTD_linear T( ) VRTD T( ) RTD T( )

VRTD_correction T( ) RTDlinear T( ) Isource_correction T( )

VRTD_linearized T( ) Isource_correction T( ) RTD T( )

Page 23: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Analog Linearization Circuits

Page 24: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Analog Linearization Circuits Two-Wire Single Op-Amp

This circuit is designed for a 0-5V output for a 0-200C temperature span. Components R2, R3,

R4, and R5 are adjusted to change the desired measurement temperature span and output.

A voltage-controlled current

source is formed from the op-amp

output through R4 into the RTD

R2 49.13kR

1 4

.99k

R3 60.43k

R5 105.83k

R4 1

kV1 5

-

+

Vout

I_Correction

I_RTD

RT

D 1

00

Example

Amplifiers:

Low-Voltage:

OPA333

OPA376

High Voltage:

OPA188

OPA277

Page 25: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Analog Linearization Circuits Two-Wire Single Op-Amp

Temperature (C)

0.00 50.00 100.00 150.00 200.00

I_Correction (A)

0.00

12.50u

25.00u

37.50u

50.00u

I_RTD (A)

980.00u

988.00u

996.00u

1.00m

1.01m

Non-linear increase in excitation current over temperature

span will help correct non-linearity of RTD measurement

R2 49.13k

R1 4

.99k

R3 60.43k

R5 105.83k

R4 1

k

V1 5

-

+

Vout

I_Correction

I_RTD

RT

D 1

00

Page 26: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Analog Linearization Circuits Two-Wire Single Op-Amp

With

Co

rre

ctio

n

With

out

Lin

ear

izat

ion

Te

mp

era

ture

(C

)

0.0

02

5.0

05

0.0

07

5.0

01

00

.00

12

5.0

01

50

.00

17

5.0

02

00

.00

Vo

ltag

e (

V)

0.0

0

62

5.0

0m

1.2

5

1.8

8

2.5

0

3.1

3

3.7

5

4.3

8

5.0

0

With

out

Lin

ear

izat

ion

With

Co

rre

ctio

n

With Correction

Without Correction

Temperature (C)

0.00 25.00 50.00 75.00 100.00 125.00 150.00 175.00 200.00

Voltage (V)

0.00

625.00m

1.25

1.88

2.50

3.13

3.75

4.38

5.00

Without Correction

With Correction

This type of linearization typically provides a 20X - 40X

improvement in linearity

R2 49.13k

R1 4

.99k

R3 60.43k

R5 105.83k

R4 1

k

V1 5

-

+

Vout

I_Correction

I_RTD

RT

D 1

00

Page 27: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Analog Linearization Circuits Three-Wire Single INA A voltage-controlled current

source is formed from the INA

output through Rlin into the RTD

+15V

+15V

-15V

-15V

Vout

Rg 8

01

R1 4

.99k

V2 5

R2 4

.99k

RL3 1

RL1 1

RL2 1

Rz 1

00

V1 15

V3 15

++

-

Rg

Rg

Ref

U2 INA826

Rlin 105.83kI_Correction

RTD 100

I_RTD

I_Bias

Remote RTD

This circuit is designed for a 0-5V output

for a 0-200C temperature span.

Components Rz, Rg, and Rlin are adjusted

to change the desired measurement

temperature span and output.

Example

Amplifiers:

Low-Voltage:

INA333

INA114

High Voltage

INA826

INA114

Page 28: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Analog Linearization Circuits Three-Wire Single INA

With Correction

Without Correction

Temperature (C)

0.00 25.00 50.00 75.00 100.00 125.00 150.00 175.00 200.00

Voltage (V)

0.00

622.27m

1.25

1.87

2.50

3.12

3.75

4.37

5.00

Without Correction

With Correction

+15V

+15V

-15V

-15V

Vout

R6 8

01

R7 4

.99k

V2 5

R9 4

.99k

RL3 1

RL1 1

RL2 1

R14 1

00

V1 15

V3 15

R1 1

0k

++

-

Rg

Rg

Ref

U2 INA826

R2 105.83kI_Correction

RTD 175.8

I_RTD

I_Bias

Remote RTD

This type of linearization typically provides a 20X - 40X

improvement in linearity and some lead resistance cancellation

Page 29: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Analog Linearization Circuits XTR105 4-20mA Current Loop Output

R1 975

R2 25

-+O

A3

RL 250

i_Q1

Q1_INT

R4 1

kR

5 1

kR

_C

L 0

Iref1 800u

Iref2 800u

Rz 100

Rlin1 16.099k

V_PS 24

Rcm 1.5k

Rg 162.644Rlin 1k

-

+OA1

-

+OA2

i_jfet

VIN-

VCM

Q1

i_afe

I_Out

i_lin

VIN+

Q1_EXT

i_rtd

V_420

RTD 100

XTR105

Page 30: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

With Correction

Without Correction

Temperature (C)

0.00 25.00 50.00 75.00 100.00 125.00 150.00 175.00 200.00

I_Out (A)

4.00m

6.00m

8.00m

10.00m

12.00m

14.00m

16.00m

18.00m

20.00m

Without Correction

With Correction

Analog Linearization Circuits XTR105 4-20mA Current Loop Output

Page 31: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Analog + Digital Linearization Circuits XTR108 4-20mA Current Loop Output

Page 32: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Digital Acquisition Circuits and Linearization Methods

Page 33: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Digital Acquisition Circuits ADS1118 16-bit Delta-Sigma 2-Wire Measurement with Half-Bridge

RTD

+Vsource

R

LR

LR

AR

RTDR

LR

LR

AR

AIN0

AIN1

AIN2

AIN3

Page 34: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Digital Acquisition Circuits ADS1220 24-bit Delta-Sigma Two 3-wire RTDs

RTDR

LR

LR

LR

RTDR

LR

LR

LR

REFR

+Vdig+Vsource

COMPR

3-wire + Rcomp shown for AIN2/AIN3

Page 35: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Digital Acquisition Circuits ADS1220 24-bit Delta-Sigma One 4-Wire RTD

RTDR

LR

LR

LR

LR

REFR

+Vdig+Vsource

Page 36: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Digital Acquisition Circuits ADS1247 24-bit Delta-Sigma Three-Wire + Rcomp

Page 37: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Digital Acquisition Circuits ADS1247 24-bit Delta-Sigma Four-Wire

Page 38: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Digital Linearization Methods • Three main options

– Linear-Fit

– Piece-wise Linear Approximations

– Direct Computations

0 80 160 240 320 400 480 560 640 720 8000.01

0.013

0.016

0.019

0.022

0.025

0.028

0.031

0.034

0.037

0.04

RTD Sensor Output vs. Temperature (Isource = 100uA)

Temperature (C)

Vo

ltag

e (V

)

VRTD(Temp)

Page 39: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Digital Linearization Methods Linear Fit

Pro’s:

•Easiest to implement

•Very Fast Processing Time

•Fairly accurate over small temp span

Con’s:

Least Accurate

0 80 160 240 320 400 480 560 640 720 8000.01

0.013

0.016

0.019

0.022

0.025

0.028

0.031

0.034

0.037

0.04

RTD Sensor Output vs. Temperature (Isource = 100uA)

Temperature (C)

Vo

ltag

e (

V)

VRTD Temp( )

VLin_Fit Temp( )

Temp

0 80 160 240 320 400 480 560 640 720 8000.01

0.013

0.016

0.019

0.022

0.025

0.028

0.031

0.034

0.037

0.04

RTD Sensor Output vs. Temperature (Isource = 100uA)

Temperature (C)

Volt

age (

V)

VRTD Temp( )

VLin_Fit(Temp)

Temp

End-point Fit Best-Fit

TLinear t( ) A RTD t( ) B

Page 40: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Digital Linearization Methods Piece-wise Linear Fit

Pro’s:

•Easy to implement

•Fast Processing Time

•Programmable accuracy

Con’s:

•Code size required for coefficients

0 80 160 240 320 400 480 560 640 720 8000.01

0.013

0.016

0.019

0.022

0.025

0.028

0.031

0.034

0.037

0.04

RTD Sensor Output vs. Temperature (Isource = 100uA)

Temperature (C)

Vo

ltag

e (V

)

VRTD(Temp)

VLin_Fit(Temp)

TPeicewise T n 1( ) T n( ) T n 1( )( )RT D RT Dn 1( )

RT Dn( ) RT Dn 1( )

Page 41: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Digital Linearization Methods Direct Computation

Pro’s:

•Almost Exact Answer, Least Error

•With 32-Bit Math Accuracy to +/-0.0001C

Con’s:

•Processor intensive

•Requires Math Libraries

•Negative Calculation Requires

simplification or bi-sectional solving

0 80 160 240 320 400 480 560 640 720 8000.01

0.013

0.016

0.019

0.022

0.025

0.028

0.031

0.034

0.037

0.04

RTD Sensor Output vs. Temperature (Isource = 100uA)

Temperature (C)V

olt

age

(V)

VRTD(Temp)TDirect t( )

A A2

4B 1RTD t( )

R0

2B+

Positive Temperature Direct Calculation

Negative Temperature Simplified Approximation

TDirect t( ) 241.96 2.2163RTD t( ) 2.8541103

RTD t( )2

9.9121 106

RTD t( )3

1.7052108

RTD t( )4

-TDirect t( ) 241.96 2.2163RTD t( ) 2.854110

3 RTD t( )

2 9.912110

6 RTD t( )

3 1.705210

8 RTD t( )

4

Page 42: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Digital Linearization Methods Direct Computation

-

-

RTDError 100 Res 60.256 Tlow 250 Thigh 50

TBisection RTDTemp 0

TmidTlow Thigh( )

2

Rcal 100 1 A Tmid BTmid2

Tmid 100( ) C Tmid3

Tmid 0if

Rcal 100 1 A Tmid B Tmid2

Tmid 0if

Rcal 0 Rcal 0if

RTDError Res Rcal

Tlow Tmid RTDError 0if

Thigh Tmid RTDError 0if

RTDError 0.0001( )while

RTDTemp Tmid

RTDTempreturn

99.999

TBisection 99.999

Bi-Section Method for Negative Temperatures

Page 43: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

Questions/Comments?

Thank you!! Special Thanks to:

Art Kay

Bruce Trump

PA Apps Team

Mike Beckman

Omega Sensors

RDF Corp

Page 44: Signal Conditioning and Linearization of RTD · PDF fileSignal Conditioning and Linearization of RTD Sensors Collin Wells Texas Instruments HPA Precision Linear Applications 9/24/11

IMPORTANT NOTICE FOR TI REFERENCE DESIGNSTexas Instruments Incorporated ("TI") reference designs are solely intended to assist designers (“Buyers”) who are developing systems thatincorporate TI semiconductor products (also referred to herein as “components”). Buyer understands and agrees that Buyer remainsresponsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products.TI reference designs have been created using standard laboratory conditions and engineering practices. TI has not conducted anytesting other than that specifically described in the published documentation for a particular reference design. TI may makecorrections, enhancements, improvements and other changes to its reference designs.Buyers are authorized to use TI reference designs with the TI component(s) identified in each particular reference design and to modify thereference design in the development of their end products. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPELOR OTHERWISE TO ANY OTHER TI INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGYOR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN, including but not limited to any patent right, copyright, mask work right,or other intellectual property right relating to any combination, machine, or process in which TI components or services are used.Information published by TI regarding third-party products or services does not constitute a license to use such products or services, or awarranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectualproperty of the third party, or a license from TI under the patents or other intellectual property of TI.TI REFERENCE DESIGNS ARE PROVIDED "AS IS". TI MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THEREFERENCE DESIGNS OR USE OF THE REFERENCE DESIGNS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY ORCOMPLETENESS. TI DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESSFOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTYINTELLECTUAL PROPERTY RIGHTS WITH REGARD TO TI REFERENCE DESIGNS OR USE THEREOF. TI SHALL NOT BE LIABLEFOR AND SHALL NOT DEFEND OR INDEMNIFY BUYERS AGAINST ANY THIRD PARTY INFRINGEMENT CLAIM THAT RELATES TOOR IS BASED ON A COMBINATION OF COMPONENTS PROVIDED IN A TI REFERENCE DESIGN. IN NO EVENT SHALL TI BELIABLE FOR ANY ACTUAL, SPECIAL, INCIDENTAL, CONSEQUENTIAL OR INDIRECT DAMAGES, HOWEVER CAUSED, ON ANYTHEORY OF LIABILITY AND WHETHER OR NOT TI HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, ARISING INANY WAY OUT OF TI REFERENCE DESIGNS OR BUYER’S USE OF TI REFERENCE DESIGNS.TI reserves the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services perJESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain the latest relevantinformation before placing orders and should verify that such information is current and complete. All semiconductor products are soldsubject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s termsand conditions of sale of semiconductor products. Testing and other quality control techniques for TI components are used to the extent TIdeems necessary to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is notnecessarily performed.TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products andapplications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provideadequate design and operating safeguards.Reproduction of significant portions of TI information in TI data books, data sheets or reference designs is permissible only if reproduction iswithout alteration and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable forsuch altered documentation. Information of third parties may be subject to additional restrictions.Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirementsconcerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or supportthat may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards thatanticipate dangerous failures, monitor failures and their consequences, lessen the likelihood of dangerous failures and take appropriateremedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use of any TI components inBuyer’s safety-critical applications.In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is tohelp enable customers to design and create their own end-product solutions that meet applicable functional safety standards andrequirements. Nonetheless, such components are subject to these terms.No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the partieshave executed an agreement specifically governing such use.Only those TI components that TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use inmilitary/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components thathave not been so designated is solely at Buyer's risk, and Buyer is solely responsible for compliance with all legal and regulatoryrequirements in connection with such use.TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use ofnon-designated products, TI will not be responsible for any failure to meet ISO/TS16949.

Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265Copyright © 2014, Texas Instruments Incorporated