short transmission line
-
Upload
mohil-shah -
Category
Engineering
-
view
109 -
download
4
Transcript of short transmission line
![Page 1: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/1.jpg)
ELECTRICAL POWER SYSTEM - II
SHORT TRANSMISSION LINE
PREPARED BY :- (BATCH B – 3)SHAH MOHIL ARUNBHAI 130280109102SHAH NEEL GIRISHKUMAR 130280109103SUHAGIYA SAUMIL ASHOKBHAI 130280109111
![Page 2: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/2.jpg)
Contents1. Introduction2. Representation of transmission line3. Classification4. Short transmission line5. Phasor diagrams6. References
![Page 3: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/3.jpg)
Introduction
Electrical power is generated in power station. It is necessary to send this power to different areas.
A conductive line which is used for the transmission of the electrical power from one place to another is known as “Transmission Line”.
![Page 4: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/4.jpg)
Representation of transmission line
![Page 5: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/5.jpg)
Classification Transmission lines are generally classified as
follows:
1) Short transmission line
2) Medium transmission line
3) Long transmission line
![Page 6: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/6.jpg)
Short transmission lineTransmission line having length less than 80
km and operating voltage less than 20 kV are generally known as Short transmission line.
Due to small distance and low voltage capacitance effect is negligible. Hence performance of these lines depend upon resistance and inductance only.
![Page 7: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/7.jpg)
Short transmission lineThe equivalent circuit of a short transmission line is
shown in Fig., where Is and IR are the sending and receiving end currents, respectively, and Vs and VR are the sending and receiving end line-to-neutral voltages.
The circuit is solved as a simple series AC circuit. So,
where Z is zl, the total series impedance of the line .
![Page 8: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/8.jpg)
Short transmission line
![Page 9: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/9.jpg)
Short transmission lineThe effect of the variation of the power factor
of the load on the voltage regulation of a line is most easily understood for the short line and therefore will be considered at this time.
Voltage regulation of a transmission line is the rise in voltage at the receiving end, expressed in percent of full-load voltage, when full load at a specified power factor is removed while the sending-end voltage is held constant.
![Page 10: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/10.jpg)
Short transmission lineCorresponding to Eq. we can write,
where | Vnl | is the magnitude of receiving-end voltage at no load and | Vfl | is the magnitude of receiving-end voltage at full load with | Vs | constant .
After the load on a short transmission line , represented by the circuit of Fig., is removed, the voltage at the receiving end is equal to the voltage at the sending end .
![Page 11: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/11.jpg)
Short transmission lineIn Fig., with the load connected , the
receiving-end voltage is designated by VR , and | VR | = | Vfl |.
The sending-end voltage is Vs ; and | Vs | = | Vnl |.
![Page 12: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/12.jpg)
Phasor diagrams
(a) Load p.f.=70% lag (b)Load p.f.=100% (c)Load p.f.=70% lead
![Page 13: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/13.jpg)
Phasor diagramsThe phasor diagrams of Fig. are drawn for the
same magnitudes of the receiving end voltage and current and show that a larger value of the sending-end voltage is required to maintain a given receiving-end voltage when the receiving- end current is lagging the voltage than when the same current and voltage are in phase.
A still smaller sending-end voltage is required to maintain the given receiving-end voltage when the receiving-end current leads the voltage.
![Page 14: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/14.jpg)
Phasor diagramsThe voltage drop is the same in the series impedance of
the line in all cases; because of the different power factors, however, the voltage drop is added to the receiving - end voltage at a different angle in each case.
The regulation is greatest for lagging power factors and least, or even negative, for leading power factors.
The inductive reactance of (transmission line is larger than the resistance, and the principle of regulation illustrated in Fig . is true for any load supplied by a predominantly inductive circuit .
![Page 15: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/15.jpg)
Phasor diagramsThe magnitudes of the voltage drops IrR and
IlXl for a short line have been exaggerated with respect to Vr in drawing the phasor diagrams in order to illustrate the point more clearl y.
The relation between power factor and regulation for longer lines is similar to that for short lines but is not visualized so easily.
![Page 16: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/16.jpg)
ReferencesElements of power system analysis by W. D.
Stevenson
Power system analysis by Grainger & Stevenson
Modern power system analysis by Nagrath & Kothari
Wikipedia
![Page 17: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/17.jpg)
![Page 18: short transmission line](https://reader036.fdocuments.us/reader036/viewer/2022062223/58a116141a28ab4b658b680d/html5/thumbnails/18.jpg)