GGEL 50MW SOLAR THERMAL POWER PLANT
SUMITTED TO: SUBMITTED BY:
Mr. VINAY KUMAR GUPTA BANWARI LAL
Assistant Professor B.Tech (E.E.)
DEPARTMENT OF Electrical Engg. SEMESTER–7th
PRATAP UNIVERSITY JAIPUR. ROLL NO.- EE110006
![Page 2: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/2.jpg)
![Page 3: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/3.jpg)
![Page 4: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/4.jpg)
INTRODUCTION
GODAWARI GREEN ENERGY LIMITED (GGEL) IS A FLAGSHIP COMPANY OF THE HIRA GROUP IN THE RENEWABLE ENERGY SECTOR.
GGEL’S FOCUS AREA IS POWER GENERATION USING RENEWABLE SOURCES SUCH AS SOLAR ENERGY, GEOTHERMAL ENERGY, WIND ENERGY ETC.
THE COMPANY WAS INCORPORATED AS A 100% SUBSIDIARY OF THE GODAWARI POWER & ISPAT LTD IN THE YEAR 2009.
![Page 5: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/5.jpg)
![Page 6: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/6.jpg)
![Page 7: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/7.jpg)
![Page 8: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/8.jpg)
WORKING PRINCIPLE OF CSP
![Page 9: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/9.jpg)
![Page 10: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/10.jpg)
HTF CYCLE
SUPERHEATER & REHEATER S
387°C
EVAPORATOR
308°C
ECONOMISER & REHEATER E
291°C
EXPANSSION
VESSEL
SOLAR FIELD
HTFPUMP
![Page 11: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/11.jpg)
WATER CYCLE
SUPERHEATER
379°CREHEATER E &
S
HP TURBINE
LP TURBINE
BFP
180°CWATER SOURCE
DM
PLANT
HP HEATER
284°C
ECONOMISER
295°C
STEAM DRUM &
EVAPORATOR
295°C
CONDENSOR
HOT WELL
DEAERATOR
REHEATER E & S
![Page 12: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/12.jpg)
BLOCK DIAGRAM OF TURBINE-ALTERNATOR CONNECTION
LP TURBINE
LP STEAM
DIRECT CONNECTION
INDIRECT CONNECTION HP STEAM
ALTERNATOR
GEAR BOXHP
TURBINE
![Page 13: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/13.jpg)
ABBREVIATIONS
UAT – UNIT AUXILIARY TRANSFORMER SST – STATION SERVICE TRANSFORMER BFP – BOILER FEED PUMP CCWP – CLOSE COOLING WATER PUMP ACWP – AUXILIARY COOLING WATER PUMP HTF – HEAT TRANSFER FLUID JOP – JACKING OIL PUMP GSC – GLAND STEAM CONDENSOR
![Page 14: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/14.jpg)
ABBREVIATIONS
MOP – MAIN OIL PUMP AOP – AUXILIARY OIL PUMP EOP – EMERGENCY OIL PUMP CEP – CONDENSATE EXTRACTING PUMP CT FAN – COOLING TOWER FAN CWP – CIRCULATING WATER PUMP MOG – MAGNETIC OIL GAUGE PRV – PRESSURE RELEAVE VALVE
![Page 15: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/15.jpg)
POWER DISTRIBUTION BLOCK DIAGRAM
GEN.70.5 MVA10.5 KV
GSU T/F75 MVA
10.5/132 KV
UAT7.5 MVA
10.5/6.6 KV
SST-12.5 MVA
10.5/0.440 KV
SST-22.5 MVA
10.5/0.440 KV
SST-31.5 MVA
6.6/0.440 KV
SST-4750 KVA
6.6/0.440 KV
HV MOTORS1.BFP-1/2/32.HTF PUMP-1/2/3/43.CWP-1/2/3
LV MOTORS1. CEP 8. VACUUM PUMP 15. SEAL WATER PUMP2. MOP 9. OIL MIST FAN 16. HTF SEAL PUMP3. AOP 10. CONTROL OIL PUMP 17. LUBE OIL PURIFIER4. EOP 11. AIR COMPRESSOR 18. CONTROL 5. JOP 12. CT FAN OFFLINE PUMP 6. CCWP 13. TURBINE GEAR7. ACWP 14. GSC
GEN. BREAKER
UAT BREAKER
BREAKER
BREAKER
HTF HEATER PUMP RW SUPPLY PUMP
R
Y
B
SWITCHING YARD
![Page 16: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/16.jpg)
POWER DISTRIBUTION TO THE TRANSFORMERS
UAT
GEN.
SST-1 SST-2
POWER T/F
1. TURBINE IS NOT RUNNING.(GRID IS AVAILABLE)
2. TURBINE IS RUNNING.(GRID IS NOT AVAILABLE)
SG
SGPOWER T/F
UAT SST-1 SST-2
GEN.
132KV
132KV
10.5KV
10.5KV
![Page 17: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/17.jpg)
GENERATOR
IT IS A DEVICE THAT CONVERTS MECHANICAL ENERGY INTO ELECTRICAL ENERGY.
IT WORKS ON THE PRINCIPLE OF EMI(ELECTRO-MAGNETIC INDUCTION) OF FARADAY.
IT IS CONNECTED TO LP AND HP TURBINE DIRECT AND INDIRECT RESPECTIVELY.
HERE THE ELECTRICITY IS GENERATED AT 10.5KV.
![Page 18: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/18.jpg)
RATED
POWER-
70.590MVA
RATED
VOLTAGE –
10500V+/- 10% V
RATED
CURRENT –
3881 A
ACTIVE POWER
-50 MW
SPEED – 3000rpm
![Page 19: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/19.jpg)
GENERATOR SPECIFICATIONS
MACHINE CODE SGEN5-100A-2P
RATED VOLTAGE 10500V +/- 10%
RATED POWER 70590 KVA
PHASES 3
CONNECTION STAR
FREQUENCY 50 Hz
P.F.(COSF) 0.708
RATED CURRENT 3881 A
EXCITATION SELF
RATED SPEED 3000 rpm
INSULATION CLASS
F
AMBIENT TEMP. 50C
PHASE SEQUENCE U1 V1 W1
IP 54
IM 7216
ACTIVE POWER 50 MW
TOTAL WEIGHT 116.800 Kg
COOLING TYPE AIR
![Page 20: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/20.jpg)
TRANSFORMER – 75 MVA (10.5KV/132KV)
IT IS AN ELECTRICAL DEVICE THAT TRANSFER ELECTRICAL ENERGY FROM ONE SIDE TO ANOTHERSIDE WITHOUT CHANGE IN ITS FREQUENCY.
TRANSFORMER IS USED TO CONVERT 10.5KV INTO 132KV FOR TRANSMISSION TO GSS(GRID SUB-STATION).
![Page 21: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/21.jpg)
MARSHAILING BOX
10.5 KV INPUT
132KV OUTPUT
GSU TRANSFORMER
COOLINGFAN
![Page 22: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/22.jpg)
REFERENCE STANDARD
IS:2026
CORE & WDG MASS
38900Kg
TANK & FITTING MASS
14900Kg
OIL MASS 17200Kg
TOTAL T/F MASS 71000Kg
TRANSPORT MASS 66000Kg
TOTAL OIL QUANTITY
20200 Liters
OVERALL DIMENSIONS
6.754.205.90 m
TRANSPORT DIMENSIONS
5.302.503.75 m
GSU TRANSFORMER PHYSICAL SPECIFICATIONS
TEMP. RISE OF OIL
60C
TEMP. RISE OF WDG
65C
AMBIENT TEMP. 50C
TYPE OF COOLING
ONAN/ONAF
TANK PLATE THICKNESS
COVER 12 mm
BOTTOM 16 mm
SIDE 8 mm
![Page 23: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/23.jpg)
SWITCHING YARD
THE APPLICATION OF SWITCHYARDS IS TO
DELIVER THE GENERATED POWER FROM
POWER PLANT AT DESIRED VOLTAGE LEVEL TO
THE NEAREST GRID OR TRANSMISSION LINE. THE SWITCHYARD IS PROVIDED WITH NECESSARY
ISOLATORS, CIRCUIT BREAKERS, CURRENT TRANSFORMER, POTENTIAL TRANSFORMERS, SURGE ARRESTORS, WAVE TRAPS, PROTECTIVE RELAYS, PLCC ETC.
SWITCHYARD IS CONTROLLED FROM DCS WHICH WILL BE LOCATED IN POWER BLOCK CONTROL ROOM.
![Page 24: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/24.jpg)
![Page 25: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/25.jpg)
CONNECTION OF T/F’S
![Page 26: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/26.jpg)
UAT CONNECTION
UAT
7.5 MVA 10.5KV/6.6KV
SST-3 1.5 MVA
6.6KV/0.440KV
SST-4750KVA
6.6KV/0.440KV
BFP(3) 875 KW 6300V 96A
3071rpm
HTFP(4) 900KW 6300V 101A
2970rpm
CWP(3) 510KW 6300V
58A 986rpm
RAW WATER PUMP SUPPLY
HTF HEATER
SPARE MOTOR FEEDER
![Page 27: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/27.jpg)
LOAD DISTRIBUTION FROM UAT
THE HV MOTORS(HTF, BFP & CWP) ARE CONNECTED TO UAT TRANSFORMER.
THE TOTAL POWER DISTRIBUTED TO HT MOTORS IN BOTH CASES ARE:
IN NORMAL CONDITION – 5470 KW TOTAL LOAD CONNECTED – 7755 KW
![Page 28: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/28.jpg)
SST-1 CONNECTION TO LOADS
SST-12.5 MVA
10.5/0.440 KV
CONDENSATE PUMP 1&3
220 KW 415 V 193 A
1488 rpm
JOP 1&2 30 KW 415 V 27.1 A
1455 rpm
CT FAN 1&3 150 KW 415 V 132 A
1482rpm
VACUUM PUMP-1 55 KW 415 V 96 A
CCWP 1&2 90 KW 415 V 78 A
2955 rpm
AOP 2 45 KW 415 V 78.4 A
1470 rpm
ACWP-1 55 KW 415 V 95.6 A
1475 rpm
AUXILIARY LOAD
150 KW
AIR COMPRESSOR
-2 37 KW 400 V
2965 rpm
COP 16 KW 415 V
TOTAL LOAD = 848 KW
![Page 29: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/29.jpg)
SST-2 CONNECTION TO LOADS
SST-22.5 MVA
10.5/0.440 KV
CT FAN-2 75 KW415 V132 A
1482 rpm
MOP45 KW415 V78.4 A
1470 rpm
AIR COMPRESSOR
-137 KW400 V
2965 rpm
VACUUM PUMP-255 KW415 V96 A
CONDENSATE PUMP-2110 KW415 V193 A
1488 rpm
ACWP-255 KW415 V95.6 A
1475 rpm
COP 16 KW
AUXILIARY LOAD
88.6 KW
TOTAL LOAD = 481.6 KW
![Page 30: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/30.jpg)
SST-4 CONNECTED LOAD
SST-4750KVA
6.6/0.440KV
RAW WATER MAKEUP PUMP (2)
18.5KW 415V 31.5A
2929rpm
WASTE WATER
PUMP (2) 1.5KW 415V 3.4A
1410rpm
TOTAL LOAD = 40
KW
![Page 31: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/31.jpg)
LOAD DISTRIBUTION FROM SST
THE LV MOTORS(CEP, CCWP, ACWP & VACUUM PUMP etc.) ARE CONNECTED TO SST TRANSFORMERS.
THERE ARE 4 SST TRANSFORMER - SST-1, SST-2, SST-3, SST-4.
THE TOTAL LOAD CONNECTED TO EACH OF THE SST IN BOTH CASE ARE:
SST-1 IN NORMAL CONDITION – 545.6 KW THE TOTAL LOAD CONNECTED – 848KW
![Page 32: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/32.jpg)
LOAD DISTRIBUTION FROM SST
SST-2 IN NORMAL LOAD CONDITION – 364.2 KW TOTAL LOAD CONNECTED – 481.6 KW
SST-4 IN NORMAL LOAD CONDITION – 20 KW TOTAL LOAD CONNECTED – 40 KW
SST-3 - ISOLATE
![Page 33: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/33.jpg)
TOTAL LOAD DISTRIBUTION FROM ALL TRANSFORMERS
TOTAL LOAD AT HV MOTORS – IN NORMAL CONDITION – 5470 KW TOTAL LOAD CONNECTED – 7755 KW
TOTAL LOAD AT LV MOTORS – IN NORMAL CONDITION – 909.8 KW TOTAL LOAD CONNECTED – 1329.6 KW
TOTAL LOAD – IN NORMAL CONDITION – 6399.8 KW TOTAL LOAD CONNECTED – 9124.6 KW
LOAD DURING NON-GENERATING HOURS – 205.5 KW
![Page 34: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/34.jpg)
![Page 35: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/35.jpg)
PPA – POWER PURCHASE AGREEMENT
![Page 36: Short description about GGEL](https://reader037.fdocuments.us/reader037/viewer/2022102808/55d0451bbb61eb42328b45fc/html5/thumbnails/36.jpg)