Shielded/Unshielded pair - 300V - 105°C - PLTC - UL 13
Transcript of Shielded/Unshielded pair - 300V - 105°C - PLTC - UL 13
MP - MT ARTEMP ®
Pyrometry
Shielded/Unshielded pair - 300V - 105°C - PLTC - UL 13
MP
- M
T A
RT
EM
P
Applications
Thermocouple extension circuits for temperature measuring and logging.
Features
Temperature rating: 105ºC maximum.Voltage rating: 300V.Construction requirements: As per UL 13 Type PLTC and UL 2250 Type ITC.Fire requirements: As per UL 1685.Thermocouple requirements: As per ASTM E 230-98 (MP codes) and IEC60584-3 (MT codes).NEC Code: Compliant with Art. 725 PLTC, Art. 727 ITC, Art. 501 classifiedlocations Class 1 Div.2 and Class 2 Div.2.Hydrocarbon requirements: As per NFC 32-200 and ASTM D 1239.
Description
Conductor:
- EX: (+) Chromel / (-) Constantan- JX: (+) Iron / (-) Constantan- KX: (+) Chromel / (-) Alumel- RX: (+) Copper E / (-) Copper A- SX: (+) Copper E / (-) Copper A- TX: (+) Copper E / (-) ConstantanInsulation: PVC.Insulation identification:
MP Codes MT Codes
Alloy (+) (-) Alloy (+) (-)- EX: - EX:- JX: - JX:- KX: - KX:- RX: - RX:- SX: - SX:- TX: - TX:
Lay length: 50 mm (20 twists/m).Unshielded pair: Polyester tape wrap.Shield: Aluminium-polyester tape helical wrap plus tinned-copper drain-wireconductor, 7-wire stranding, class B.Sheath: PVC; fire-retardant; sunlight and hydrocarbon-resistant.
MP ARTEMP ®
Shielded pair
1 WWW.MARLEW.COM.AR These specifications are provided as references and could be changed without previous notice.
MP - MT ARTEMP ®
Pyrometry
Shielded/Unshielded pair - 300V - 105°C - PLTC - UL 13
MP
- MT
AR
TE
MP
Sheath identification
MP Codes MT Codes
Alloy Alloy - EX: - EX:- JX: - JX:- KX: - KX:- RX: - RX:- SX: - SX:- TX: - TX:Stripping: Polyamide ripcord under the sheath.
Outstanding Features
Optionals
Insulation:High-density polyethylene, UL Listed PLTC.Sheath: Fire-retardant and mineral-oil-resistant.Armour: Zinc-plated steel served-wire helical armour or aluminium interlock armourplus PVC sheath (colour coded depending on the alloy and requirement); fire-retardant, sunlight and hydrocarbon-resistant. These cables are UL certified fordirect earth burial.
See Technical Note # 8, "Wire armour properties"
Alternatives
Construction requirements: As per ICEA S 73-532 (300V and 600V), BritishStandard 5308, EN 50288-7 and NBR 10300.Materials: Thermocouple extension cables can be silicone sheathed or insulatedfor enhanced performance when exposed to high temperature conditions. Cablescan be made to order based on the materials and construction alternativesdescribed in the technical information appendix.
Installation
Assembly: Minimum bend radius is 7xOD (unarmoured versions) and 12xOD(armoured cables).Maximum pulling tension: 5daN/sq mm on copper conductors. Wire-armouredcables can withstand 10daN/sq mm on the armour wires.Assembly temperature: 5ºC or higher.
Direct burial SequentiallyMarked
Fire-retardant Hydrocarbon-resistant
Sunlight resistant
MP ARTEMP ®
Unshielded pair
2 WWW.MARLEW.COM.AR These specifications are provided as references and could be changed without previous notice.
MP - MT ARTEMP ®
Pyrometry
Shielded/Unshielded pair - 300V - 105°C - PLTC - UL 13
MP
- M
T A
RT
EM
P
Dimensions & Weight
Type Gauge Configuration Standard Armoured cables (zinc-plated steel wirearmour)
sqmm
AWG Conductor
Drainwire
Code Outsidediameter
mm
Weightkg/km
Code Underarmour
diametermm
Outsidediameter
mm
Weightkg/Km
Rigid pair 0.5 20 1 x 080 -- MP/MT + 1205 4.8 28 MP/MT + 1205 H 4.8 8.4 140
Rigid pair 1.31 16 1x 1.29 -- MP/MT + 1213 6.0 49 MP/MT + 1213 H 6.0 10.1 205
Flexible pair 0.5 20 16 x 0.20 -- MP/MT + 1305 5.1 30 MP/MT + 1305 H 5.1 8.7 152
Flexible pair 0.81 18 26 x 0.20 -- MP/MT + 1308 5.7 40 MP/MT + 1308 H 5.7 9.3 175
Flexible pair 1.31 16 42 x 0.20 -- MP/MT + 1313 6.4 52 MP/MT + 1313 H 6.4 10.5 214
Flexible pair 1.50 15 48 x 0.20 -- MP/MT + 1315 6.6 57 MP/MT + 1315 H 6.6 10.7 225
SHIELDEDDimensions & Weight
Type Gauge Configuration Standard Armoured cables (zinc-plated steel wirearmour)
sqmm
AWG Conductor
Drainwire
Code Outsidediameter
mm
Weightkg/km
Code Underarmour
diametermm
Outsidediameter
mm
Weightkg/Km
Rigid pair 0.5 20 1 x 080 1 x 0.65 MP/MT + 1000 4.9 32 MP/MT + 1000 H 4.9 8.5 144
Rigid pair 1.31 16 1x 1.29 1 x 1.00 MP/MT + 1001 6.1 58 MP/MT + 1001 H 6.1 10.2 211
Flexible pair 0.5 20 16 x 0.20 7 x 0.25 MP/MT + 1006 5.1 34 MP/MT + 1006 H 5.1 8.8 159
Flexible pair 0.81 18 26 x 0.20 7 x 0.30 MP/MT + 1036 5.8 44 MP/MT + 1036 H 5.8 9.5 181
Flexible pair 1.00 17 32 x 0.20 7 x 0.30 MP/MT + 1026 6.1 49 MP/MT + 1026 H 6.1 10.2 206
Flexible pair 1.31 16 42 x 0.20 7 x 0.40 MP/MT + 1046 6.5 61 MP/MT + 1046 H 6.5 10.6 225
Flexible pair 1.50 15 48 x 0.20 7 x 0.40 MP/MT + 1016 6.7 66 MP/MT + 1016 H 6.7 10.8 234
“+” Thermocouple identification according to the alloy EX - JX - KX - RX - SX - TX.For example: MPKX 1205 (Unshielded rigid pair KX Chromel/Alumel thermocouple).
Thermocouple temperature range
Thermocoupletype
MP Cables / ASTM E 230-98 MT Cables / IEC 60584-3
Specialtolerance
Standardtolerance
Temperaturerange
Class 1 Tolerance Class 2Tolerances
Temperaturerange
EX +/- 1ºC +/- 1.7ºC 0ºC to 200ºC +/-120uV(+/-1.5ºC) +/- 240uV(+/-2.5ºC)
-25ºC to 200ºC
JX +/- 1.1ºC +/- 2.2ºC 0ºC to 200ºC +/- 85uV (+/-1.5ºC) +/- 140uV(+/-2.5ºC)
-25ºC to 200ºC
KX +/- 1.1ºC +/- 2.2ºC 0ºC to 200ºC +/- 60uV (+/-1.5ºC) +/- 100uV(+/-2.5ºC)
-25ºC to 200ºC
RX and SX ---- +/- 5ºC 0ºC to 200ºC ---- +/- 30uV (+/-2.5ºC) 0ºC to 100ºC
TX +/- 0.5ºC +/- 1ºC -60ºC to200ºC
+/- 30uV (+/-0.5ºC) +/- 60uV (+/-1ºC) -25ºC to 100ºC
Powered by TCPDF (www.tcpdf.org)
3 WWW.MARLEW.COM.AR These specifications are provided as references and could be changed without previous notice.