Shielded/Unshielded pair - 300V - 105°C - PLTC - UL 13

3
MP - MT ARTEMP ® Pyrometry Shielded/Unshielded pair - 300V - 105°C - PLTC - UL 13 MP - MT ARTEMP Applications Thermocouple extension circuits for temperature measuring and logging. Features Temperature rating: 105ºC maximum. Voltage rating: 300V. Construction requirements: As per UL 13 Type PLTC and UL 2250 Type ITC. Fire requirements : As per UL 1685. Thermocouple requirements: As per ASTM E 230-98 (MP codes) and IEC 60584-3 (MT codes). NEC Code: Compliant with Art. 725 PLTC, Art. 727 ITC, Art. 501 classified locations Class 1 Div.2 and Class 2 Div.2. Hydrocarbon requirements: As per NFC 32-200 and ASTM D 1239. Description Conductor: - EX: (+) Chromel / (-) Constantan - JX: (+) Iron / (-) Constantan - KX: (+) Chromel / (-) Alumel - RX: (+) Copper E / (-) Copper A - SX: (+) Copper E / (-) Copper A - TX: (+) Copper E / (-) Constantan Insulation: PVC. Insulation identification: MP Codes MT Codes Alloy (+) (-) Alloy (+) (-) - EX: - EX: - JX: - JX: - KX: - KX: - RX: - RX: - SX: - SX: - TX: - TX: Lay length: 50 mm (20 twists/m). Unshielded pair: Polyester tape wrap. Shield: Aluminium-polyester tape helical wrap plus tinned-copper drain-wire conductor, 7-wire stranding, class B. Sheath: PVC; fire-retardant; sunlight and hydrocarbon-resistant. MP ARTEMP ® Shielded pair 1 WWW.MARLEW.COM.AR These specifications are provided as references and could be changed without previous notice.

Transcript of Shielded/Unshielded pair - 300V - 105°C - PLTC - UL 13

Page 1: Shielded/Unshielded pair - 300V - 105°C - PLTC - UL 13

MP - MT ARTEMP ®

Pyrometry

Shielded/Unshielded pair - 300V - 105°C - PLTC - UL 13

MP

- M

T A

RT

EM

P

Applications

Thermocouple extension circuits for temperature measuring and logging.

Features

Temperature rating: 105ºC maximum.Voltage rating: 300V.Construction requirements: As per UL 13 Type PLTC and UL 2250 Type ITC.Fire requirements: As per UL 1685.Thermocouple requirements: As per ASTM E 230-98 (MP codes) and IEC60584-3 (MT codes).NEC Code: Compliant with Art. 725 PLTC, Art. 727 ITC, Art. 501 classifiedlocations Class 1 Div.2 and Class 2 Div.2.Hydrocarbon requirements: As per NFC 32-200 and ASTM D 1239.

Description

Conductor:

- EX: (+) Chromel / (-) Constantan- JX: (+) Iron / (-) Constantan- KX: (+) Chromel / (-) Alumel- RX: (+) Copper E / (-) Copper A- SX: (+) Copper E / (-) Copper A- TX: (+) Copper E / (-) ConstantanInsulation: PVC.Insulation identification:

MP Codes MT Codes

Alloy (+) (-) Alloy (+) (-)- EX: - EX:- JX: - JX:- KX: - KX:- RX: - RX:- SX: - SX:- TX: - TX:

Lay length: 50 mm (20 twists/m).Unshielded pair: Polyester tape wrap.Shield: Aluminium-polyester tape helical wrap plus tinned-copper drain-wireconductor, 7-wire stranding, class B.Sheath: PVC; fire-retardant; sunlight and hydrocarbon-resistant.

MP ARTEMP ®

Shielded pair

1 WWW.MARLEW.COM.AR These specifications are provided as references and could be changed without previous notice.

Page 2: Shielded/Unshielded pair - 300V - 105°C - PLTC - UL 13

MP - MT ARTEMP ®

Pyrometry

Shielded/Unshielded pair - 300V - 105°C - PLTC - UL 13

MP

- MT

AR

TE

MP

Sheath identification

MP Codes MT Codes

Alloy Alloy - EX: - EX:- JX: - JX:- KX: - KX:- RX: - RX:- SX: - SX:- TX: - TX:Stripping: Polyamide ripcord under the sheath.

Outstanding Features

Optionals

Insulation:High-density polyethylene, UL Listed PLTC.Sheath: Fire-retardant and mineral-oil-resistant.Armour: Zinc-plated steel served-wire helical armour or aluminium interlock armourplus PVC sheath (colour coded depending on the alloy and requirement); fire-retardant, sunlight and hydrocarbon-resistant. These cables are UL certified fordirect earth burial.

See Technical Note # 8, "Wire armour properties"

Alternatives

Construction requirements: As per ICEA S 73-532 (300V and 600V), BritishStandard 5308, EN 50288-7 and NBR 10300.Materials: Thermocouple extension cables can be silicone sheathed or insulatedfor enhanced performance when exposed to high temperature conditions. Cablescan be made to order based on the materials and construction alternativesdescribed in the technical information appendix.

Installation

Assembly: Minimum bend radius is 7xOD (unarmoured versions) and 12xOD(armoured cables).Maximum pulling tension: 5daN/sq mm on copper conductors. Wire-armouredcables can withstand 10daN/sq mm on the armour wires.Assembly temperature: 5ºC or higher.

Direct burial SequentiallyMarked

Fire-retardant Hydrocarbon-resistant

Sunlight resistant

MP ARTEMP ®

Unshielded pair

2 WWW.MARLEW.COM.AR These specifications are provided as references and could be changed without previous notice.

Page 3: Shielded/Unshielded pair - 300V - 105°C - PLTC - UL 13

MP - MT ARTEMP ®

Pyrometry

Shielded/Unshielded pair - 300V - 105°C - PLTC - UL 13

MP

- M

T A

RT

EM

P

Dimensions & Weight

Type Gauge Configuration Standard Armoured cables (zinc-plated steel wirearmour)

sqmm

AWG Conductor

Drainwire

Code Outsidediameter

mm

Weightkg/km

Code Underarmour

diametermm

Outsidediameter

mm

Weightkg/Km

Rigid pair 0.5 20 1 x 080 -- MP/MT + 1205 4.8 28 MP/MT + 1205 H 4.8 8.4 140

Rigid pair 1.31 16 1x 1.29 -- MP/MT + 1213 6.0 49 MP/MT + 1213 H 6.0 10.1 205

Flexible pair 0.5 20 16 x 0.20 -- MP/MT + 1305 5.1 30 MP/MT + 1305 H 5.1 8.7 152

Flexible pair 0.81 18 26 x 0.20 -- MP/MT + 1308 5.7 40 MP/MT + 1308 H 5.7 9.3 175

Flexible pair 1.31 16 42 x 0.20 -- MP/MT + 1313 6.4 52 MP/MT + 1313 H 6.4 10.5 214

Flexible pair 1.50 15 48 x 0.20 -- MP/MT + 1315 6.6 57 MP/MT + 1315 H 6.6 10.7 225

SHIELDEDDimensions & Weight

Type Gauge Configuration Standard Armoured cables (zinc-plated steel wirearmour)

sqmm

AWG Conductor

Drainwire

Code Outsidediameter

mm

Weightkg/km

Code Underarmour

diametermm

Outsidediameter

mm

Weightkg/Km

Rigid pair 0.5 20 1 x 080 1 x 0.65 MP/MT + 1000 4.9 32 MP/MT + 1000 H 4.9 8.5 144

Rigid pair 1.31 16 1x 1.29 1 x 1.00 MP/MT + 1001 6.1 58 MP/MT + 1001 H 6.1 10.2 211

Flexible pair 0.5 20 16 x 0.20 7 x 0.25 MP/MT + 1006 5.1 34 MP/MT + 1006 H 5.1 8.8 159

Flexible pair 0.81 18 26 x 0.20 7 x 0.30 MP/MT + 1036 5.8 44 MP/MT + 1036 H 5.8 9.5 181

Flexible pair 1.00 17 32 x 0.20 7 x 0.30 MP/MT + 1026 6.1 49 MP/MT + 1026 H 6.1 10.2 206

Flexible pair 1.31 16 42 x 0.20 7 x 0.40 MP/MT + 1046 6.5 61 MP/MT + 1046 H 6.5 10.6 225

Flexible pair 1.50 15 48 x 0.20 7 x 0.40 MP/MT + 1016 6.7 66 MP/MT + 1016 H 6.7 10.8 234

“+” Thermocouple identification according to the alloy EX - JX - KX - RX - SX - TX.For example: MPKX 1205 (Unshielded rigid pair KX Chromel/Alumel thermocouple).

Thermocouple temperature range

Thermocoupletype

MP Cables / ASTM E 230-98 MT Cables / IEC 60584-3

Specialtolerance

Standardtolerance

Temperaturerange

Class 1 Tolerance Class 2Tolerances

Temperaturerange

EX +/- 1ºC +/- 1.7ºC 0ºC to 200ºC +/-120uV(+/-1.5ºC) +/- 240uV(+/-2.5ºC)

-25ºC to 200ºC

JX +/- 1.1ºC +/- 2.2ºC 0ºC to 200ºC +/- 85uV (+/-1.5ºC) +/- 140uV(+/-2.5ºC)

-25ºC to 200ºC

KX +/- 1.1ºC +/- 2.2ºC 0ºC to 200ºC +/- 60uV (+/-1.5ºC) +/- 100uV(+/-2.5ºC)

-25ºC to 200ºC

RX and SX ---- +/- 5ºC 0ºC to 200ºC ---- +/- 30uV (+/-2.5ºC) 0ºC to 100ºC

TX +/- 0.5ºC +/- 1ºC -60ºC to200ºC

+/- 30uV (+/-0.5ºC) +/- 60uV (+/-1ºC) -25ºC to 100ºC