SHC 3.4MCD

SAGE HEATER With PK or BL Control Box

Maintenance Manual

6-12-2012

Page 2: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 2

Page 3: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 3

TABLE OF CONTENTS

Maintenance

1. Introduction ……………………………………………………… 4 2. Heater Component Description

Main Heater Components ……………………………… 6 Burner & Head Assembly Components ……………… 7

3. Maintenance Schedule ……………………………………… 8 4. Record Information ……………………………………………… 11 5. Visual Inspection ……………………………………………… 13 6. Burner Assembly Inspection

Remove Burner Assembly ……………………………… 14 Nozzles ……………………………………………… 16 Electrodes ……………………………………………… 17 Retention ring adjustments ……………………………… 18

7. Insulation & Coils Inspection Front Insulation Inspection ……………………………… 19 Rear Target Inspection ……………………………… 23 Coil Inspection ……………………………………… 24 Reinstall Burner Assembly ……………………………… 25

8. Component Check Blower Speed ……………………………………………… 26 Fuel pressure ……………………………………………… 28 Air switch ……………………………………………… 29 Flow Sender ……………………………………………… 30

9. Battery Replacement Procedure PK Control Box ………………………………………... 31 BL Control Box ………………………………………… 32

10. Run Heater and observe correct operation ……………………… 35 Appendix

A1. Heater Statistics Form 38 A2. Fault list 39 A3. Setup Data Sheet 40 A4. Example Insulation Breakdown 41 A5. Inspection Sheet 43 A6. Collecting the Truck and Heater Info 44 A7. Insulation Packing (service Bulletin) 46

Page 4: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 4

1.0 Introduction

SAGE 3.4 Million BTU Glycol Heating System

The SAGE 3.4 Million BTU Glycol Heating System (the system) is a mobile tank-less heater. The glycol is heated as it flows through the system, and does not retain any glycol internally except for what is in the heat exchanger coil. The system heats glycol on an as needed base, shutting the heater safely down when not needed. The SAGE Heater is a reliable and proven system. SAGE Heaters have been successful in military and commercial ground support applications for over 30 years. Under normal usage and annual maintenance, the SAGE Heater will give you many years of superior performance. This is achieved by using a unique stainless steel alloy heat exchanger core and high quality manufacturing standards. The combustion chamber operates under industrial forced draft design principles, with the exhaust slightly above atmospheric pressure. Heat from the flame is transferred to coils carrying glycol fluid thru an air / fluid exchange process. The heater operates using diesel fuel for safety. SAGE Heaters are highly efficient. Utilizing up to 13 stages of heat modulation, the system can easily meet variable demand requirements by providing superior temperature control. This results in constant output temperature regardless of input temperature. This is a critical performance benefit in the de-icing process. In de-icer truck applications the system is designed for instant heating capabilities. The advantage of instant heating is that it does not require preheating of the glycol, therefore, aircrafts can be de-iced in cold climate conditions, quickly and efficiently. The glycol flows through the system (heat exchanger coils) by means of an external fluid pumping system. The fluid pumping systems primary purpose is to provide the appropriate fluid pressure at proper flow rates to successfully de-ice aircraft.

Due to the pump pushing the glycol through the heater exchanger coils, the heater inlet fluid pressure is greater than the outlet pressure in the heating system (up to the nozzle). The Global truck design pushes the fluid as pressure drops across each section of the fluid plumbing, which includes the heater, transport hoses, all fittings and the nozzle.

Page 5: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 5

The system is controlled by a DCS (Digital Control System / Heater Control Box). There are presently two versions of the Heater Control Box. Heaters from SN 9000 to 9949 are designated the PK series. Heaters from SN 90950 and up are designated the BL Series. The system is designed around a safety first approach with many operational safety interlock devices. Fluid flow rates and temperature rates are constantly monitored and used to calculate the required heat input. When heat is not required the system safely shuts down. When heat is required the system safely ignites based on the glycol fluid temperature and flow rate. The SAGE 3.4 Million BTU Glycol Heating System is a mobile on-demand heater. It operates on an intermittent cycle with 6 levels of safety control. The design intent for this heater was to provide an on-demand heater for de-icing aircrafts.

1. If the RTD (Remote Temperature Device) outlet temperature sensor detects 210 °F, the heater control box shuts the heater down in an orderly process. The BL series control box has a user selectable set point of 200 °F or 210 °F.

2. Second outlet temperature sensor (preset at 220 °F), which is an input to the controller as

a safety signal for proper controller shutdown.

3. Third outlet temperature sensor (preset at 230 °F), which cuts power to the heater.

4. Stack temperature switch, which is used as a safety shutoff, and cuts power to the heater.

5. Mechanical Over pressure relief valve at 400 psi on the outlet side.

6. Air Pressure switch to prove proper combustion air is available

Another important benefit of the DCS is the extensive diagnostic capabilities. This includes event logging of fault codes for fast and efficient troubleshooting, component status to verify that each piece of equipment operates correctly, and real time monitoring to see the operational parameters while the heater is running. In addition the BL series control box can records these diagnostic parameters to the SD-card for review or printout on a Windows based computer. For proper operation and service life it is required that end of season maintenance be performed annually as per SAGE heater maintenance schedule.

Page 6: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 6

2.1 Main Heater Components

Figure 1

Page 7: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 7

2.2 Burner & Head Assembly Components

Figure 2

Reference Global Parts Manual for associated part numbers

Page 8: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 8

3.0 Maintenance Schedule

MAINTENANCE PERIOD IN HOURS 8 50 100 200 OTHER

4.1

Record statistics at the end of every de-icing season.

• See form A1 at end of this manual. See GGS technical manual procedure – System History Statistics (page 30)

• Measure and record stack temperature each year.

Annually

5.1 Visually inspect outside of heater

• Look for discolorations and abnormalities. See Sect 3.0 Figs. 3 & 4.

X

Annually

5.2

Check heater for leaks • Inspect the heater for Hydraulic leaks • Inspect the heater for fuel leaks • Inspect the heater for glycol leaks • Inspect the heater inside the truck area.

X

Annually

5.3

Inspect and Clean exhaust screen. • Remove the heater exhaust screen and

remove any debris and clean with a soft wire brush. See Fig. 4.

X

Annually

5.4

Check exhaust duct • Inspect exhaust duct for cracks and loose

fasteners • Check for exhaust leaks. See Fig. 1 & 2

X

Annually

5.5

Check blower assembly • Inspect blower wheel and housing for

cracks, deformations, and loose fasteners. Be sure inlet cage is securely attached. See Fig. 2

• Check for air leaks at the mounting gasket for the Blower and the Burner plate. See Fig. 2

X

Annually

6.2

Replace fuel nozzle. • Remove burner assembly from burner head

(see section 6.1) • Remove and replace with new nozzles.

X

Annually

6.3

Check ignition electrode gap. • See Burner Assembly Adjustment Data on

page 6 • Replace electrode if worn beyond

dimensions. Replace at 200 hours.

X

Annually

Page 9: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 9

MAINTENANCE PERIOD IN HOURS 8 50 100 200 OTHER

6.4

Clean carbon buildup from burner assembly • Remove the burner assembly from the

heater Head. Use a soft small wire brush to clean any carbon buildup from all the parts of the burner. Be careful not to damage or misalign any component.

X

Annually

6.5

Check flame retention ring settings. • See Burner Assembly Adjustment Data on

page 6. • Check that retention rings are securely

attached and not damaged.

X

Annually

7.1

Check front insulation. • See page 10. If the gap is larger than ¼”,

perform packing procedure.

X

Annually

7.2

Check rear target insulation See page 10

X

Annually

7.3 Inspect for carbon buildup on inner coils

• Remove with soft wire brush and vacuum out.

X

Annually

8.1

Check Blower operation and calibration of Air pressure transducer

• Use component status • Check hydraulic controller

X

Annually

8.2

Check fuel pressure • Refer to GGS Technical manual for check

and adjustment procedure

X

Annually

8.3 Check fuel controller per GGS Technical manual – fuel pressure driver head.

X

Annually

8.4 Check air switch operation as per Global Ground Support Technical manual

X

Annually

Page 10: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 10

MAINTENANCE PERIOD IN HOURS 8 50 100 200 OTHER

8.5

Check Flow sender operation as per GGS technical manual – flow sender setup

X

Annually

9.1

Replace computer backup battery • For PK Series go to page 31 • For BL Series go to page 32

Annually

9.2

Replace fuel filter element • Fuel filter is located under the heater near

the outlet manifold, which connects to the burner head fuel inlet line.

• Disconnect fuel filter and replace with new Filter element

X

Annually

10.1 Check the auxiliary engine.

• Verify that the engine RPM at high throttle is per manufactures specifications.

X

Annually

10.2

Check fuel valve solenoid operation as follows: • Make sure the fluid tanks are filled with a

few hundred gallons of cold fluid • Turn on the heater. After the heater fires

look thru the sight glasses and verify that all the solenoids (4) have fully turned on after each stage fires successively until stage 13 is achieved

X

Annually

10.3

Page 11: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 11

4.0 Recording Heater information System History (Statistics) -Power up the control box. Follow the sequence of screen shots and record info on Heater Statistics Form in appendix A1.

Page 12: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 12

Page 13: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 13

5.0 Heater Inspection Areas Look at the exterior of the Heater and pay special attention to the rear area as noted in figure 8. Examine all around the back of the Heater where the rear plate bolts to the Heater Body. Also inspect the front of the Heater in the same location where the front plate bolts to the Heater Body. Look for discoloration or other abnormalities.

Figure 3 - Back view of Heater

Figure 4 - Front View of Heater

Check 360° around the Heater for abnormalities

Check 360° around the Exhaust Duct for leaks

Check 360° around the Heater for abnormalities

Check the Blower Assembly & Motor for signs of damage

Check the Exhaust screen for signs of debris

Check for signs of leakage

Check for signs of leakage

Page 14: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 14

6.1 Removing the Burner Assembly.

Pull both Burner Assemblies from the Burner Head by: -Disconnect all the electrical connectors. This includes the

-Cad cell connector -Fuel Solenoid connectors -Fuel Heater connector

-Remove the fuel line. -Remove the ignition wire from the ignition coil. -Remove the winged thumb screws that hold the burner assembly to the air box.

Slowly pull the burner assembly (see Figure 8) out and place in a safe area. Be careful to protect the nozzles and the retentions rings from damage and dirt. Place the burner assembly in a protected area.

Figure 7

Inspect the cork gasket. Replace if necessary. Use these directions in reverse to put the burner assembly back. Be careful to align all 4 burners into the air box when installing.

Air Box Front of Burner Assy.

Front Plate Cork

Gasket

Page 15: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 15

Figure 8

Figure 9 shows the inside of the air box. Use a towel or rag to clean each of the burner tubes inside the air box from any residual diesel fuel. Also clean out any debris that you see in the air box.

Figure 9

Back of Burner Assy.

Area 1 Area 2

Area 3 Area 4

Page 16: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 16

6.2 Replacing the fuel nozzles.

IMPORTANT: For proper heater operation, nozzles must be

replaced every year or 100 hours.

Clean burner assembly including the fuel nozzle areas. To remove the old nozzles, use two wrenches (5/8” and 3/4”) and turn counterclockwise (right hand thread) until nozzles are removed. Replace with new proper nozzles. See picture below.

Page 17: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 17

6.3 Electrode Inspections and Adjustment Inspect electrode and verify the following settings as per the drawing below. If the dimensions cannot set, then the electrodes are worn and will need replacement.

Figure 6

Page 18: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 18

6.4 Burner Tube Adjustments Set the default “A” dimension on the 4 burner’s as stated in the chart in Fig. 4. These dimensions will allow most heaters to run properly as long as the Air pressure and the Fuel Pressures are correctly adjusted. The only time you will deviate from these settings are if the fuel is changed, or it is at a different altitude where adjusting the Blower speeds (Air pressure) cannot get the heater to perform as expected. The heater can be adjusted for varying altitudes and fuels thru the Air pressure adjustment (Blower speed), If this (air pressure adjustment) cannot get the desired results then the next step would be to adjust the depth of the Burner tubes, In (toward the burner plate) allowing more air and out (away from the burner plate) allowing less air, All this is in a balance, because the Computer only see the air pressure reading. Two Types of Adjustment: Course which is the “A” Dimension (Mechanical) Fine which adjusts the actual Air pressure numbers (Software)

Figure 5

Page 19: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 19

7.1 Burner Head Front Insulation Inspection

Using the series of pictures below, inspect the front Burner Head. See next page for procedure. Note any abnormalities. There is usually some minor marking on the insulation. A typical view is shown in figure 10. There are two main areas of inspection, the Insulation and the Metal Shield (Saturn Ring). Insulation inspection focuses on the white 1-1/2” insulation board inside the Metal shield (Saturn Ring). No pieces of insulation should be cracked or missing in the center area and outer region. See appendix A4 for examples of wear and damage. Inspect the Metal Shield (Saturn Ring). All metal should be intact. No excess distortion should be seen. If gap between Metal Shield (Saturn Ring) and inner coils is in excess of 1/8” see appendix A7 for insulation packing procedure.

This is a view of a typical good Burner Head Insulation. This view is looking at a removed Burner Head on the other side of the air box. You should see this with a mirror and flashlight as depicted in the following pictures starting with figure 10.

Figure 10

Inspect the rear insulation by looking all the way to the rear of the heater combustion chamber. Again, there should be no pieces missing or damaged. Slight discoloration is usual as is some surface cracks of a minor nature.

Burner Head Insulation

(CENTER AREA) Inspect this area

Metal Shield (Saturn Ring)

Burner Head Insulation

(OUTER REGION) Area of inspection should be 360 deg.

Burner Tubes

Typical 4 places Insulation missing in this area is not

important.

Page 20: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 20

With Mirror and Flashlight, inspect insulation by inserting mirror thru Burner Tubes and looking at the outer section of the insulation. Look at all the insulation, but pay close attention to the lower region as depicted in figure 9.

Figure 11

Figure 12

Page 21: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 21

Figure 13

Figure 14

Look at all areas of the back of the Burner Head by moving through the Burner Tubes as necessary. Note the location of any abnormalities. Use the areas in the picture as designations. Look for missing sections or deep cracked insulation. See page 13 for examples.

Page 22: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 22

This is a typical picture of a front insulation. See Appendix A4 for examples of damaged insulation.

If damage is found, then:

1. Fill out the Inspection report in appendix A5 2. Take photographs of the damage 3. Submit inspection report and photographs to your Service provider.

Page 23: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 23

7.2 Rear Target Inspection With the Burner assembly removed use a flashlight to look thru the burner tubes and visually inspects the rear target. This is a typical picture of the rear target insulation. See Appendix A4 for examples of damaged insulation.

If damage is found, then:

1. Fill out the Inspection report in appendix A5 2. Take photographs of the damage 3. Submit inspection report and photographs to your Service provider.

Page 24: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 24

7.3 Coil Inspection Inspect the coils for excessive carbon buildup. Clean as required. Only use a soft brush to loosen carbon and vacuum out. Note. Be careful when cleaning as to not damaging the front and rear insulation materials.

If damage is found, then:

1. Fill out the Inspection report in appendix A5 2. Take photographs of the damage 3. Submit inspection report and photographs to your Service provider.

Page 25: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 25

7.4 Reinstall Burner Assembly Use section 6.1 in reverse to re-install the burner assembly. Before installing Burner assembly check the following:

1. Mating surfaces are clean 2. Gasket is on good shape 3. All fasteners and hardware are in place.

Carefully slide in Burner assembly. DO NOT FORCE

Page 26: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 26

8.1 Blower Operational Check

Setup (start air speed)

Stage 14 is the starting blower stage. It must be adjusted via air pressure reading to give a shaft speed of 1600 +/- 50. The shaft speed will need to be measured by a tachometer Select an air pressure (shown by A) to achieve a blower shaft speed of 1600 rpm. When this is achieved, then set the pressure (shown by B)

Page 27: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 27

Blower Signal Test.

The signal is from 0 to 4095, Blower shaft speed is from 400 to 5000 RPM. Use photo tachometer to verify the low and high blower speed.

Page 28: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 28

8.2 Fuel System Operational Check

Toggle the fuel pressure signal from low to high (signal 0 – 5000) Low is approximately 75 psi High is approximately 300 psi

If fuel pressure does not go thru full range then recalibrate per Global fuel setup procedure.

Page 29: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 29

8.3 Air Switch Component Check Switch should be open below 1000 rpm and closed above 1000 rpm

Page 30: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 30

8.4 Flow Sender Component Check

Toggle to any screen, such as below, that displays fluid flow (F). This should be approximately 50-60 gallons / minute at approximately 200 psi

Page 31: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 31

9.0 Change Battery

Removal of the battery from the PK digital control system will result in

Loss of Data

In order to avoid the loss of user-entered values such as: flow sender calibration, air pressure settings, fault history & statistics use the following procedure

As a precaution, all user-entered settings should be recorded in the event that the data is lost.

Supply power to the control box and be sure the computer is powered. This may be verified by observing the display located on the front of the control box. If any message is displayed, the computer is powered.

While maintaining this power, unplug the old battery and replace it with the new battery. The system voltage will maintain the memory while the battery is being exchanged.

CAUTION Care should be taken when working on the system while power is applied.

Page 32: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 32

BL Backup Battery Replacement & System Information Procedure: STEP 1: Download System Information to the SD-card from Heater Control System. 1) Power down the heater control system. 2) Insert the SD-card into the card bay, push in all the way till the bay holds the cards. 3) Power up the system again. 4) Go to "Setup Area" 5) Go to the following screen option (Screen #1). Press F2 on the screen:

Screen #1 ******************** !! Setup Area !! Dn=F1 !Scroll! Up=F4 Data Operations F2 Flow Switch S.P. F3 ********************

6) The application will display the following screen option (Screen #2). Please press F2 on the

system keypad to go to Create Logs screen option:

Screen #2 ******************** Data Operations F2 Data To/From SD F3 Log Operations ESCAPE: F4 ********************

7) At this screen the user may download the information to the sd-card. Pressing F2 will

download the system information to the sd-card from the heater control system (Screen #3).

Screen #3 ******************** System Information Press F2 to Download Press F3 to Upload ESCAPE: F4 ********************

8) As the information is being saved on the sd-card the system will display the following

message (screen #4). Once the operation is completed the system will revert to the Main Screen.

Screen #4 ******************** Performing file operations, please wait till the Main screen displays ********************

Page 33: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 33

STEP 2: Replace Backup Battery on Main board located inside the Heater Control

Enclosure. Refer to the BL Parts list Document for location and PN. 9) Remove the power, by pressing E-STOP button on the system. 10) Remove the metal protective cover off the Main board. 11) Now locate the backup battery on the Main board, and un-hinge the battery from the battery

holder. 12) Place a new battery on top of the batter holder and push the battery in the battery holder. 13) Place the metal protective cover back on the Main board. STEP 3: Upload System Information from the SD-card to the Heater Control System. 14) Power up the heater control system. 15) Go to "Setup Area" 16) Go to the following screen option (Screen #5). Press F2 on the screen:

Screen #5 ********************* !! Setup Area !! Dn=F1 !Scroll! Up=F4 Data Operations F2 Flow Switch S.P. F3 *********************

17) The application will display the following screen option (Screen #6). Press F2 on the system

keypad to go to Create Logs screen option:

Screen #6 ********************* Data Operations F2 Data To/From SD F3 Log Operations ESCAPE: F4 *********************

18) At this screen the user may upload the information to the system. Pressing F3 will upload the

system information from the SD-card to the heater control system (Screen #7). Once the operation is completed the system will revert to the Main Screen.

Screen #7 ******************** System Information Press F2 to Download Press F3 to Upload ESCAPE: F4 ********************

Page 34: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 34

List of Errors:

1) If the following error screen appears:

" Data Logging " " File Operation " " Failed "

Check that a properly formatted SD-card is in the bay.

Reboot or Re-Power Up the Heater Control System. Perform the operation again.

Page 35: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 35

Run Heater and observe correct operation

Description of Heater startup

Upon closure of the Power Switch, the CPU and Display are powered up. Upon closure of the Heater Switch, the CPU goes thru a switch check. At the end of the switch check, the CPU activates the Blower, the Heater Enabled Light, and the Fuel Heater. At this time a pre-purge countdown begins. Two thirds thru the Pre-purge the Ignition and Fuel Pump are activated. At the end of the Pre-purge the Fuel Solenoid #1 is energized (Stage-14). Upon sighting a flame inside the heater, the CPU continues thru a ramp up cycle, this includes energizing the Flame On Light, and ramping up the air, then fuel, to the next run up stage (Stage-1), then (Sage -5), then (Stage-8), then (Stage-11), then (Stage-12), then (Stage-13) (See Heater Spooling Up Operation below for more detail). At this point the CPU controls the heat output, to a predetermined temperature, thru fuel pressure and the number of fuel solenoids that are energized. In addition all inputs are monitored with safety being the first concern and temperature control being the second. Upon reaching the predetermined outlet temperature the CPU stages down the heater until Stage 1. After this, the inlet temperature of 180 °F or the user selected temperature will be reached turning off the heater and all outputs except the Blower and Heater Enabled Light. A post-purge cycle then begins. At the end of the post-purge cycle, the CPU turns off the Blower control and Heater Enabled light. Heater Spooling Up Operation When the heater spools up, it lights off at stage 14 then to stage 1 increasing the fuel pressure to 200psi and air pressure with nozzle 1 open. After stage 1 if needed, the heater will spool up to stage 5 leaving the fuel pressure the same (200psi) and leaving nozzle 1 open, increasing the air pressure and opening nozzle 2. If needed the heater will spool up to stage 8 leaving the fuel pressure the same (200psi) nozzles 1 & 2 open increasing the air pressure and opening nozzle 3. If needed, the heater will spool up to stage 11 leaving the fuel pressure the same (200psi), nozzles 1,2, & 3 open , increasing the air pressure and opening nozzle 4. If needed, the heater will spool up to stage 12 increasing the fuel pressure to 250psi, nozzles 1, 2, 3, & 4 open and increasing the air pressure. If needed, the heater will spool up to stage 13 increasing the fuel pressure to 300psi, nozzles 1, 2, 3 & 4 open and increasing the air pressure. If the maximum stage is not needed, the heater will only spool up to the stages needed to give outlet temperature of 180 + / -5. Refer to the heater stage values in chart in appendix A3. To manually check the Maximum blower speed, Turn the override knob fully clockwise, the blower should reach Max speed typically 5,000 RPM. Adjustment is required if either the Fuel or Blower control heads are replaced Adjustment is required after replacing either the fuel or blower electrical control heads.

Page 36: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 36

Detailed heater operation by view of relay bank. PK Series Only Open the control box and locate the relay bank as seen below.

With the fluid temperature at ambient temperature, Turn on the heater and observe the operation as indicated under Heater turn-on sequence. View all the site glasses and observe that all burner tubes ignite when they are supposed to.

Relay 08

Relay 09

Relay 01

Relay 02

Relay 03

Relay 04

Relay 05

Relay R2

Relay 07

Relay 06

Relay 010

Page 37: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 37

Heater start sequence for the SAGE 3.4M Heater (PK Series).

1. Heater enable light (Relay 08) comes on at the beginning of the cycle and stays on until the heater is fully shut off

2. Next the Fuel Heater (Relay 010) is energized and will stay on approximately 3 minutes after the flame is detected.

3. Next the Exciter (Relay 02) is energized and will stay on until a flame is detected.

4. Next the Fuel pump (Relay 03) is energized and will stay on during the heating operation.

5. Next the Fuel 1 Solenoid (Relay 04) is energized. They stay on dependent on the stage that the computer set due to heat requirements.

6. Next the Flame on Light (Relay 09) is energized and stays on until the flame is extinguished.

7. Next the Fuel 2 Solenoid (Relay 05) is energized. They stay on dependent on the stage that the computer set due to heat requirements.

8. Next the Fuel 3 Solenoid (Relay R2) is energized. They stay on dependent on the stage that the computer set due to heat requirements.

9. Next the Fuel 4 Solenoid (Relay 07) is energized. They stay on dependent on the stage that the computer set due to heat requirements.

10. Next At Temp Light (Relay 06) is energized when the heater has reach the requested temperature.

11. The Fault light (Relay 01) will not turn on under normal conditions. If a fault occurs than this light will turn on.

Page 38: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 38

Detailed heater operation by view of relay bank. BL Series Only The picture below shows the Printed Circuit Board with the relay bank outlined by the red box. When the associated LED is on the relay is energized.

Page 39: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 39

Heater start sequence for the SAGE 3.4M Heater (BL Series).

1. Heater enable light (RL1) comes on at the beginning of the cycle and stays on until the heater is fully shut off

2. Next the Fuel Heater (RL2) is energized and will stay on approximately 3 minutes after the flame is detected.

3. Next the Exciter (RL3) is energized and will stay on until a flame is detected.

4. Next the Fuel pump (RL4) is energized and will stay on during the heating operation.

5. Next the Fuel 1 Solenoid is energized. They stay on dependent on the stage that the computer set due to heat requirements.

6. Next the Flame on Light (RL5) is energized and stays on until the flame is extinguished.

7. Next the Fuel 2 Solenoid is energized. They stay on dependent on the stage that the computer set due to heat requirements.

8. Next the Fuel 3 Solenoid is energized. They stay on dependent on the stage that the computer set due to heat requirements.

9. Next the Fuel 4 Solenoid is energized. They stay on dependent on the stage that the computer set due to heat requirements.

10. Next At Temp Light (RL6) is energized when the heater has reach the requested temperature.

11. The Fault light (RL7) will not turn on under normal conditions. If a fault occurs than this light will turn on.

Page 40: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 40

A1. Heater Statistics Form (PK Series) (as per section 4.1)

Page 41: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 41

A2. Fault List (PK Series) 10 Indication that air switch is closed when it should be open. (EVEN IF THE HEATER HAS NOT BEEN TURNED ON YET) 15 Indication that cad cell circuit is closed when it should be open. (FLAME SIGHTED BEFORE HEATER RUNNING OR AFTER

HEATER TURNED OFF) 20 Indication that hold contact circuit is closed when it should be open. 25 Indication that glycol flow is less than 20 G.P.M. for 5 seconds or more. (AFTER HEATER HAS BEEN TURNED ON) 30 Indication that outlet temperature has exceeded set point of mechanical over temperature switch lower setting. (Upper setting and stack switch are

wired in series, and will cut the power to the heater control relay coils.) Lower limit should be set at 225degress F, Upper limit should be set at

235 degrees F, and Stack switch is factory set at 1400 degrees F. 35 Indication that Inlet RTD circuit is open or indicated temperature is higher

then__400 °F__. 40 Indication that Inlet RTD circuit is closed /shorted or indicated temperature

is lower then __100 °F __. 45 Indication that Outlet RTD circuit is open or indicated temperature is higher

then__400 °F __. 50 Indication that Outlet RTD circuit is closed /shorted or indicated

temperature is lower then __100 °F __. 55 Indication that Fuel pressure transducer circuit is open or indicated pressure

has exceeded __500__ psi. 60 Indication that Fuel pressure transducer circuit is closed /shorted or

indicated pressure has exceeded lower limit (6 psi). 65 Indication that air switch circuit is open when it should be closed. 70 Indication that cad cell circuit is open when should be closed (loss of flame

after heater has been running) 75 Indication that hold contact circuit is open when it should be closed . (Under volt relay open or CB-5 open also trips this fault code) 80 Indication that heater failed to ignite during a normal attempt to start. 85 Indication that there is no input to the hi-throttle circuit of the computer.

(Currently this circuit is also thru the fluid level circuit of the deicer.) 90 Indication that the Air pressure transducer has a open control circuit. 95 Indication that the Air pressure transducer has a shorted/closed control

circuit.

Page 42: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 42

A2. Fault List (BL Series) 10 Indication that air switch is closed when it should be open. (EVEN IF THE HEATER HAS NOT BEEN TURNED ON YET) 15 Indication that cad cell circuit is closed when it should be open. (FLAME SIGHTED BEFORE HEATER RUNNING OR AFTER

HEATER TURNED OFF) 20 Indication that hold contact circuit is closed when it should be open. 25 Indication that glycol flow is less than 20 G.P.M. for 5 seconds or more. (AFTER HEATER HAS BEEN TURNED ON) 30 Indication that outlet temperature has exceeded set point of mechanical over

temperature switch lower setting. (Upper setting and stack switch are wired in series, and will cut the power to the heater control relay coils.)

Lower limit should be set at 225degress F, Upper limit should be set at 235 degrees F, and Stack switch is factory set at 1400 degrees F.

35 Indication that Inlet RTD circuit is open or indicated temperature is lower then__-100 °F__.

40 Indication that Inlet RTD circuit is closed /shorted or indicated temperature is higher then __400 °F __.

45 Indication that Outlet RTD circuit is open or indicated temperature is lower then__-100 °F __.

50 Indication that Outlet RTD circuit is closed /shorted or indicated temperature is higher then __400 °F __.

55 Indication that Fuel pressure transducer circuit is open or indicated pressure is lower than __-6__ psi.

60 Indication that Fuel pressure transducer circuit is closed /shorted or indicated pressure has exceeded high limit (500 psi).

65 Indication that air switch circuit is open when it should be closed. 70 Indication that cad cell circuit is open when should be closed (loss of flame

after heater has been running) 75 Indication that hold contact circuit is open when it should be closed . (Under volt relay open or CB-5 open also trips this fault code) 80 Indication that heater failed to ignite during a normal attempt to start. 85 Indication that there is no input to the hi-throttle circuit of the computer.

(Currently this circuit is also thru the fluid level circuit of the deicer.) 90 Indication that the Air pressure transducer has a open control circuit. 95 Indication that the Air pressure transducer has a shorted/closed control

circuit.

Page 43: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 43

A3. Set-up Data Sheet

Stage

Solenoids Active

Fuel Press

Fuel Flow

Air Press (wc)

Blower RPM

AIR SW TRIP 0 0 1000-1200 AIR SW

14 (light off) #1 150 6 1.25 " 1550 1 #1 200 7.1 3.50 " 2700to3100 2 #1 250 7.91 4.50 " 2900to3400 3 #1 300 8.66 5.50 " 3300to4000 4 #1 & 2 150 12 6.75 " 3400to4100 5 #1 & 2 200 14.1 7.00 " 3600to4200 6 #1 & 2 250 15.81 7.10 " 3700to4300 7 #1 & 2 300 17.32 7.50 " 3900to4400 8 #1 & 2 & 3 200 21.2 8.10 " 4000to4500 9 #1 & 2 & 3 250 23.72 8.25 " 4100to4600

10 #1 & 2 & 3 300 25.98 8.50 " 4300to4700

11 #1 & 2 & 3 & 4 200 28.2 9.00 " 4600to4800

12 #1 & 2 & 3 & 4 250 31.62 10.00 " 4700to4900

13 #1 & 2 & 3 & 4 300 34.64 10.50 " 4900to5000 15 (post purge) 0 0 9.00 " 16 (post purge) 0 0 5.00 " Starts stage 14,then adjusts air and then fuel to stage1, then to stage 5, then to stage 8 Then to stage 11, then to stage 12 then to stage 13, after that , the heater targets to the Outlet set point adjusting the stages. Air leads the fuel going up, fuel leads the air going down.

Page 44: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 44

A4. Insulation Breakdown Examples

The above damage can be repaired with insulation putty The above picture is damaged beyond repair.

Insulation is cracked thru

Page 45: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 45

Continued Example of warped metal shield (Saturn ring). Follow packing procedure in appendix A7 If a heater is identified to have Saturn Ring distortion is in excess of 1” there should be further inspection and images made with a digital camera to determine if the Saturn Ring Insulation component is broken. If the Saturn Ring Insulation appears to be broken beyond mild cracking the Wet Blanket Insulation Kit should not be installed.

Page 46: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 46

A5. Inspection Sheet

Inspection Sheet

DATE of Inspection _______/_____/______ Airport ________________________________ Customer _________________________________ Contact Person ______________________ Phone _____-______-______X______ Truck and Heater Data The following to be found on the Global ID Plate (Located on Boom Pedestal in rear heater compartment of truck)

Deicer Manufactured Date____/____/_____ Deicer Serial Number_____________________ The following to be found in the truck cab Deicer Truck Aux Engine Hours (from the hour meter) ______________ The Serial number is found using figure 3 Heater Serial Number ____________________ The following to be found in the Heater control box in the right/rea of the heater compartment. See figure 5. If no hour meter exists, pull hours from the computer screen. Heater Hours (from the hour meter) _____________________ Inspection Information Heater general appearance, especially the rear and front of the Heater_____________________ _____________________________________________________________________________ Burner Head insulation (Outer Region) inspection results _______________________________ _____________________________________________________________________________ Metal Shield Ring inspection results_______________________________________________ _____________________________________________________________________________ Gap Measurement _____________________________________________________________ Please take digital pictures of suspected damaged areas. Inspected by _________________

Page 47: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 47

A6. Collecting the Truck and Heater Info Location of the Truck Serial Number is in the rear of the truck on the Boom Pedestal.

Figure 1 Next get the Truck Auxiliary Engine Hours inside the truck cabin. The hour meter is on the control panel to the right of the drivers seat. Record the Heater Serial Number. The location of the Serial number is shown below.

Figure 2

Truck Serial

Number

Heater

Serial Number

Page 48: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 48

Location of the Heater Hour meter is in the Heater Control Box (Select PK Series only) in the rear of the truck. Record the reading.

Figure 3

On the BL Series use the Display screen and keypad to retrieve the hour meter information in the statistics page.

Heater Hour Meter

Page 49: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 49

A7. Insulation Packing The following Service Notification is published to address the sealing condition between the high and low pressure zones of the Sage Heater – SCH 3.4 MDC Heater. A post production upgrade has been developed to improve the seal of the heater head assembly with the inner fluid coil. It has been determined that this can improve the longevity and efficiency of the heater. Under certain conditions it will also prevent a premature break down of the existing head assembly insulation components. Kit contents and instructions are as follows; CONTENTS: 1. 1 Section of Wet blanket TOOLS REQUIRED: Digital Camera, 9/16 in wrench, 7/16 in wrench, wire cutter (flush), Small adjustable wrench, duck bill pliers, sharp utility knife, wire ties and soft brush PROCEDURE: 1. REMOVE BURNERS

1.1 Remove wire ties on solenoid wiring; remove exciter cable at exciter (careful with inner cable)

1.2 Disconnect fuel solenoid wires, disconnect fuel heater wires, and disconnect cad cell wiring.

1.3 Disconnect fuel line at solenoid #2, remove 16 wing screws, loosen burner plates from air box

1.4 Remove burner plate fasteners and Remove burner heads.

Page 50: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 50

2. INSPECTION

1.1 Identify any excess space between the Saturn Ring and the Inner Fluid Coil. Inspect 360 degrees around. This can be done with a 1/8” welding rod or with a shim of a known thickness (1/8”).

1.1.1 Gaps in excess of 1/8” should be addressed with the Insulation Kit. IF

this condition exists proceed with the following procedure.

1.2.1 If a substantially deformed Saturn Ring and or Broken Burner Head Insulation is identified during this procedure, e-mail digital photos to and contact Maloya Laser.

3. WET BLANKET INSTALLATION

3.1 If possible, remove any insulation debris from the area between the Saturn Ring and Inner Fluid Coil and in front of this area. This is to minimize old pieces of insulation from interfering with the insertion of the Wet Blanket.

3.2 Pinch a leading edge of the Insulation to a point to aid in insertion.

Page 51: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 51

3.3 Position Wet Blanket in front of Saturn Ring (A) and slide and compress as much as possible into the opening by hand or with a blunt tool, This will take approx. 10-20 Minutes (B). Trim off any excess with utility knife (C) Repack any loose material and remove left over cut pieces (D).

(A) (B)

(C) (D)

Page 52: SHC3.4MCD MAINTENANCE MANUAL 6-12-12

SHC3.4MCD Heater Maintenance.doc Page 52

(E) View of completed Wet Blanket Installation 3.4 Air Dry for 24 hours prior to operation. If operating the heater with in a few days

of this procedure, cycle on and off several times to fully dry out material.