SEW-EURODRIVE GmbH & Co KG Revision P.O. Box 3023 76642 ...
Transcript of SEW-EURODRIVE GmbH & Co KG Revision P.O. Box 3023 76642 ...
*23046511_0816*Drive Technology \ Drive Automation \ System Integration \ Services
Revision
Fieldbus InterfacesUFF41B and UFR41B Fieldbus Gateway
Edition 08/2016 23046511/EN
SEW-EURODRIVE GmbH & Co KGP.O. Box 302376642 Bruchsal/GermanyPhone +49 7251 75-0Fax +49 7251 [email protected]
www.sew-eurodrive.com
1 RevisionBus systems
Revision – UFF41B and UFR41B Fieldbus Gateway2
1 RevisionThis revision applies to the following documentations:• "UFF41B Fieldbus Gateway – DeviceNet™ and PROFIBUS DP" manual, part
number 16756428, edition 02/2009• "UFR41B Fieldbus Gateway – EtherNet/IP™, Modbus/TCP and PROFINET IO"
manual, part number 16798813, edition 05/2009
ReplacementChapter 2.2 "General safety notes for bus systems" is completely replaced by chapter1.1 "Bus systems".
SupplementChapter 13 "Technical data" is supplemented by chapter 1.2 "Port overview".
1.1 Bus systemsA bus system makes it possible to adapt electronic drive components to the particularsof the machinery within wide limits. There is a risk that a change of parameters thatcannot be detected externally may result in unexpected (but not uncontrolled) systembehavior and may have a negative impact on operational safety, system availability, ordata security.Especially in Ethernet-based networked systems and with engineering interfaces,make sure that unauthorized access is prevented.Use IT-specific safety standards to increase access protection to the ports. For a portoverview, refer to the respective technical data of the used device.
1.2 Port overview1.2.1 PROFINET
Port TCP/UDP
Function Authorization
Ethertype 8892hex Process data exchange Controlling connection
Dynamicport defini-tion via EndPoint Map-per
UDP PROFINET DCE/RPC Reading and writing on all indexed parameters
23 TCP Telnet Reading OEM diagnostic data
80 TCP http The Java application uses SMLP via Port 300,reading and writing IP parameters,reading and writing indexed parameters
161 UDP SNMP Reading on MIBs
300 TCP SMLP (MOVILINK® on Ethernet) Reading and writing of all parameters
300 UDP Address Editor Reading and writing the IP parameters
2304
6511
/EN
– 0
8/20
16
1RevisionPort overview
Revision – UFF41B and UFR41B Fieldbus Gateway 3
1.2.2 EtherNet/IP™, Modbus/TCP
Port TCP/UDP
Function Authorization
Ethertype 80E1hex ODVA ring redundancy protocol DLR Reading and writing the ring redundancy para-meter
23 TCP Telnet Reading OEM diagnostic data
80 TCP http The Java application uses SMLP via Port 300,reading and writing IP parameters,reading and writing indexed parameters
300 TCP SMLP (MOVILINK® on Ethernet) Reading and writing of all parameters
300 UDP Address Editor Reading and writing the IP parameters
5021) TCP Modbus/TCP Reading and writing on all indexed parameters
2222 UDP EtherNet/IP™ IO data Controlling connection
44818 TCP EtherNet/IP™ explicit messages Reading and writing on all indexed parameters1) not for MFE62 fieldbus interface
1.2.3 Engineering interface
Port TCP/UDP
Function Authorization
21 TCP FTP Reading from and writing to the file system
23 TCP Telnet Reading OEM diagnostic data
300 TCP SMLP (MOVILINK® on Ethernet) Reading and writing of all parameters
300 UDP Address Editor Reading and writing the IP parameters
(308) TCP/UDP
3D simulation (optional)
(XXX) TCP/UDP
Other application-specific, pro-grammed applications
2304
6511
/EN
– 0
8/20