SEVERE WEATHER/IMPACT DOORGLASS
-
Upload
shayann-behjati -
Category
Documents
-
view
215 -
download
0
description
Transcript of SEVERE WEATHER/IMPACT DOORGLASS
Decorative Doorglass
Doorglass Blinds
Grilles Between Glass
Clear/Low-E Doorglass
SEVERE WEATHER/IMPACT DOORGLASS
Reflections
2
Safe and Secure.
Severe Weather® Doorglass is certified for use in a range of entrance
systems to meet Florida and Texas wind-borne requirements in areas
where wind speeds can exceed 150mph. Meets DP+/-65 wind and
missile impact code requirements for the HVHZ (High Velocity
Hurricane Zone)
Missile Impact Tested The missile impact test fires an 8-foot long 2"x 4" at 50 feet per
second at designated spots. The door must remain intact through
9000 pressure cycles and also pass water infiltration, structural
loading, and forced air infiltration tests. Also meets Department of
Defense minimum anti-terrorist blast standards.
3
Strength and Beauty.
Add Value Decorative Doorglass, Blinds and Grillles are sealed between
impact-resistant laminated glass on the exterior, and tempered
safety glass on the interior. This glass is thermally sealed to save
energy, and insulated for air and water-tight performance. “
Our patented frame design, which is mechanically fastened in the
corner to prevent flex, adds strength to the door. The laminated
glass construction suppresses noise with a Sound Transmission Class
(STC Value) of 36.
Doorglass Blinds Thermally sealed in a dust-free environment, between two
glass panels, the blinds tilt a full 180º, and are protected
with a 20-year warranty.
New Frame ProfileWith a classic frame profile, the narrow
aluminum extrusion adds strength while
maintaining a pleasing shape. The natural
contours provide a traditional architectural
style, while the white powder coat surface
provides a polished finish.
4
Proven Performance.
Laminated Glass Western Reflections Severe Weather/Impact Doorglass meets the ASTM
C1172 standard for laminated glass. During the stringent laminated
manufacturing process, inherent marks may appear. Slight bubbles, lines or
surface imperfections are not considered glass defects. Most clear
doorglass options are available in Low-E.
0.125” Glass Panel
0.090 PVB Inner Layer
0.125” Glass Panel
Doorglass blinds significantly reduce solar heat gain while providing light and privacy control. Product warranties are backed by rigorous performance testing. Blinds are tested for 10,000 operating cycles. Doorglass must pass a 25,000 slam cycle test.
Safe and SoundNo dangling cords or tilt wands, no dusting, and no swing-ing blinds. Safe for children and pets. Reduces allergen exposure.
LondonPatina Caming
Door LON-P 2264 HSideliteLON-P 0764 H
DoorLON-P 2248 H
NEW
5
Proven Performance.
Saves Energy. Look for Low-E
• Proven Energy Saver
• Reduce Fabric Fading
• Eliminate Drafts and Cold Spots
• Reduce Condensation
Doorglass blinds can reduce solar heat gain by up to
77% and reduce heat loss by up to 28%.
6
ElanBlack Chrome Caming
DoorELN-BC 2210 H
Door ELN-BC 2264 HSideliteELN-BC 0764 H
Door ELN-BC 2280 HSideliteELN-BC 0880 H
DoorWYN 2248 H
DoorWYN 2210 H
Door WYN 2264 HSideliteWYN 0764 H
Door WYN 2280 HSideliteWYN 0880 H
Transom is not available in Severe Weather/Impact Doorglass.
WyngateWrought Iron
7
FontanaSatin Nickel Caming
WindsorPatina or Platinum Caming
DoorWSR-P/WSR PL 2248 H
Door WSR-P/WSR PL 2264 HWSR-P/WSR PL 2064 HSideliteWSR-P/WSR PL 0764 H
Door WSR-P/WSR PL 2280 HSideliteWSR-P/WSR PL 0880 H
DoorFON-SN 2210 H
Door FON-SN 2264 HSideliteFON-SN 0764 H
8
ReflectionsPlatinum Caming
LaurelBrass or Platinum Caming
DoorRGC-PL 2248 H
Door RGC-PL 2264 HRGC-PL 2064 HSideliteRGC-PL 0764 H
Door RGC-PL 2280 HSideliteRGC-PL 0880 H
DoorLRL-B/LRL-PL 2210 H
Door LRL-B/LRL-PL 2264 HSideliteLRL-B/LRL-PL 0764 H
Door LRL-B/LRL-PL 2280 HSideliteLRL-B/LRL-PL 0880 H
9
PrincessPlatinum Caming
St. CharlesPatina Caming
Door STC-P 2264 HSideliteSTC-P 0764 H
Door STC-P 2264 H
Door GFD-PL 2264 HSideliteGFD-PL 0764 H
10
BlindsRaise, Lower & Tilt
Grilles Between GlassAvailable in 5/8” & 7/8” Grilles
DoorRLB 1464 H
Door RLB 1480 HRLB 2280 HRLB 2080 H
DoorRLB 2264 HRLB 2064 HSidelite RLB 0864 HIGB O764(tilt only)
DoorRLB 2236 H
Door2236 9L
Door2064 15L2264 15L Sidelite0764 5L
Door2080 18L 2280 18L Sidelite0880 6L
Door1480 12L
Door 2080 12L2280 12L
Door2064 10L 2264 10L
Door1464 10L
Available in Clear and Low-E Glass
Available in Clear and Low-E Glass
11
Clear & Gray Glass
Grilles Between GlassPrairie Style
Western Reflections Cares
Thousands of marine turtles nest in U.S.
coastal areas, and state and local ordinances
protect hatchling turtles by limiting the
brightness of inside-to-outside visible light
transmittance. Western Reflections’
Severe Weather/Impact product line
includes tinted gray glass that meet these
code requirements.
Door 2236 9L
Door2280 9L
Door 2064 9L2264 9LSidelite0764 6L
Door 2236 1L
Door 2210 1L
Door 1464 1L 2064 1L 2264 1L Sidelite0764 1L
Door 1480 1L2080 1L2280 1LSidelite0880 1L
Door 2236 1L SG
Door 2264 1L SG2064 1L SGSidelite0764 1L SG
Door2280 1L SG2080 1L SGSidelite0880 1L SG
CLEAR GLASS GRAY GLASS
Available in Clear and Low-E Glass
Severe Weather Doorglass Specifications
17130-231 • 210187 (10/10)
Severe Weather® Doorglass Thermal Values* Door System Clear Glass Low-E GlassDoor System Configuration with full glass U-Factor SHGC U-Factor SHGCFiberglass Door - Polyurethane Core 0.37 0.31 0.35 0.26Steel Door - Wood Edge - EPS Core 0.35 0.31 0.33 0.26Steel Door - Steel Edge - EPS Core 0.40 0.31 0.38 0.26
* All values are with full size glass and are representative. Contact Western Reflections for more information.
Low Sound TransmissionThe Sound Transmission Class (STC Value) for Severe Weather Doorglass is 36, and is independent of doorglass size. Third party test reports are available upon request.
Thermal PerformanceThermal performance ratings are determined for a fixed set of conditions and specifications and will vary by door manufacturer.
Wind-Borne Debris Zone — Approved for Use• Areas where the basic wind speed is 120 mph or greater.
110 mph and within 1 mile of the coast.
• Doors are required to meet ASTM E1886 and E1996 test standards for impact, or be shuttered.
• All openings must comply with specific design pressure (DP) ratings in accordance with ASTM E330.
High Velocity Hurricane Zone (HVHZ) — Approved for Use• Dade and Broward counties
• Doors are required to meet Florida TAS 201 and 203 test standards for impact, or be shuttered.
• All openings must comply with specific design pressure (DP) ratings in accordance with TAS202.
TEXAS FIRST TIERCOASTAL COUNTIESSEAWARD ZONE 130 mph 3-second gust design wind speed
INLAND (I) ZONE 120 mph 3-second gust design wind speed
INLAND (II) ZONE 110 mph 3-second gust design wind speed
Design Pressure Rating: +65.0/–65.0For design pressure ratings, installation instructions or any product particulars and use limitations, see installation instruction INST 13346.2 at www.floridabuilding.org.
Hurricane Zones
1.800.507.830212©Western Reflections 2010
WR-SW 1210261 Commerce Way • Gallatin, TN 37066Ph 615.451.9700 • Fx 615.230.4301