Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate...

22
Session 9 Guardrail Attachments to Bridge Ends

Transcript of Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate...

Page 1: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Session 9Guardrail Attachments to

Bridge Ends

Page 2: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Common Deficiencies in Bridge Railings

Inadequate Dynamic Strength

Potential for Snagging

Use of “Safety” Walk

Inadequate Transition

13-2

Page 3: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Transitions Guardrail Deflects – Bridge Ends DONOT!!

Bridge End Connections are an example of a change in the type of Barrier Deflection Characteristics

Must Reduce the Deflection of the Guardrail before you reach the Bridge End from 3’ to Zero

Must have adequate Structural Connection

Page 4: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Transition Considerations

Adequate structural connection to the bridge railing

Reduced post spacing and nested rail to increase stiffness gradually

Block outs and rub rails used to minimize snagging

Page 5: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

How can you REDUCE DEFLECTION of Standard

Strong Post W-Beam Guardrail Normal Guardrail Post Spacing is 6’3”

Reduce Post Spacing to 3’ 1½” and reduce deflection by 50%

Nest the Guardrail (double thickness) and reduce deflection by 50%

Add a Guardrail panel to the back of the Post and reduce deflection by 50%

Add a Rub Rail and reduce deflection by nearly 50% & reduce snagging potential

Combine 2 of the above and reduce deflection by 75%

Page 6: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

How can you REDUCE DEFLECTION of Standard

Strong Post W-Beam Guardrail

Nested

ReducedPostSpacing

Page 7: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Gradually Increase Stiffness by Increasing the

number of Post

13-7

Page 8: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Rub Rail Components - Std Draw RBC-001 002 & 003 “Guardrail

Connection to Bridge End Type A and A-1 Components”

Rub Rail

RubRail

Not Island Curb

Page 9: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Standard Drawing RBC-001Guardrail Connector to

Bridge End Type A and A-1

Page 10: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Inadequate Structural Connection or Stiffening of

Approach Rail

Page 11: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Adequate Structural Connection Terminal Sect No

2 Plate A & B

Page 12: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Inadequate Reduction in Deflection and Structural

Connection

Page 13: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Transition of Curb and Rub Rail to Bridge’s Safety

Shape

Page 14: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Addition of a Spacer Tube

Page 15: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Combination of all of the Proceeding for a Successful

Transition

Page 16: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Std Draw RBC-001 Guardrail Connection to Bridge End

Type A and A-1

Page 17: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Curb Inlet Type BShould have Island Curb in

Throat of the Inlet Std Draw RBC-

001 Note 5 “Island Curb”

Std Draw RBD-280

“Match Adjacent Curb”

Page 18: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Curb Inlet Type BShould have Island Curb in

Throat of the Inlet

Lt Std Draw RBD-280 Curb Box Inlet Type B (Detail Drawing) “Match Adjacent Curb”

Rt Std Draw RDB-281 Curb Box Inlet Type B (Steel Drawing) "Island Curb Detail”

Page 19: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Type B Drainage Box As-Builts vs. Std Draw

Construction memo No 5-11July 6, 2011

Have not been getting Island Curb on Type B Inlet therefore a Const Memo was Issued

See Std Draw RBC-001, RBD-280, RBD-281 Previous Slides

Corrective Actions: Retrofit by extending the double ply rail from

25 linear feet to 50 linear feet Replace the drain box top with the correct

one

Page 20: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Std Draw RDB-280 Curb Box Inlet Type B 2012 Design Changed Detail to Show Island Curb instead of Std

Curb

Changed to Island Curb

Page 21: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

Normally getting Standard Curb instead of Island Curb

Page 22: Session 9 Guardrail Attachments to Bridge Ends. Common Deficiencies in Bridge Railings Inadequate Dynamic Strength Potential for Snagging Use of “Safety”

What makes this a good Guardrail Connection to Bridge

End? Q & A Time