Consultancy in operational and maintenance problems of thermal power generation, RLA, R&M and the following services are provided to various clients:
- Residual Life Assessment of all types of Boilers ranging from process Steam Boiler to500MW capacity. - Residual Life Assessment of all types of Waste Heat Recovery Boilers. - Residual Life Assessment of Hydro Gas and combined cycle Power Plant components. - Residual Life Assessment of Steam turbine. - Renovation and Modernisation and Life Extension studies of Boilers, Turbines and otherplant equipment. - Failure Analysis of Power Plant Components. - Investigation study for root cause analysis on boiler tube failure (BTF). - Health Assessment / Condition Assessment of Condenser Tubes. - Detection and sizing of flaws (e.g. cracks) in complex geometric plant components. - Condition assessment and end of functional service life Evaluation of RCC and STEELstructures in Thermal Power Plants and Process steam Industries etc.. - Third party Inspection of passive fire protection systems.
Half Cell Potentio Meter Test Half Cell PotentioMeter Test Ultrasonic Concret Test Meter Test Failed Boiler Tube Sampe Forfailure Analysis At TR
1 / 5
Services Offered
MPI of 210 MW IP Rotor at one of the steam turbine.
DPT of water turbine blades at one of the Hydroelectric power plant.
Fibroscopic inspection of headers at one of the 210 MWboiler.
2 / 5
Services Offered
TOFD test on 210 MW steam turbine IP rotor shaft
Hydrogen embrittlement checking work at Z -panel area of 210 mw plant
In-situ metallurgical inspection of header at 210 MW boiler.
3 / 5
Services Offered
Failed boiler tube collected for failure analysis of weld joint
Thermal image of GT Neutral flexible connection.
Coal bunker inspection using DP test
4 / 5
Services Offered
Coal bunker inspection using DP test
Condition assessment of concrete structure in progress
Ultrasonic test on FD fan foundation