Server : Installs Server and Client on one PC only (Setup.exe) Communications Modules : USB Drivers and utilities Documents : All manuals in PDF format Client : Installs Client (Setup.exe) Firmware: Various Firmware Files Update: Service packs (if needed) Adobe Acrobat Reader Included on DVD TIP: To configure the IP address of the RBH-UNC100-XXX use the ‘Device Discovery’ tool built into the Integra32 software. Install the Integra32 software… Login…go to tools menu… select ‘Device Discovery’ . Choose the proper network card and select search… any controllers on the network segment will be displayed. Select the desired controller and edit….enter the IP address and select ok. The default password is ‘password’. License : Feature Key Web : Web Server Installer DVR : Integration Packs Fingerprint : Integration Packs THIS DOCUMENT IS FOR QUICK REFERENCE ONLY, REFER TO HARDWARE & SOFTWARE MANUALS FOR FULL DETAILS Processor: Intel Core 2 Duo or better Memory: 1-2 GB depending on OS Storage: 20 GB, or more if needed DVD-ROM, Ethernet Port, USB ports Operating System: Windows Editions: Pro, Business, Ultimate 32 Bit: Windows 7, 8, Server 2003, 2008 64 Bit: 7, 8, Server 2008 Integra32 Server UNC 100 Static LAN IP Address Required for UNC Static Internet IP Address for Router Router on site Broadband Modem CAT5 (300’ Max.) Port Forwarding - Configure Router to forward designated IP port on Internet IP address (as entered in Integra32) to a port on Local Network (UNC100). Example: In Integra32 software set 5.6.23.7 port 75. On remote router forward remote site port 75 on 5.6.23.7 to UNC100 on port 3002 on 192.168.1.125 CAT5 RBH does not provide tech support on port forwarding! Internet PC to Router to Internet to Router to Controller INTERNET CONTROLLER WITH LAN GATEWAY - UNC100 OVERVIEW DVD CONTENTS PC SPEC Note1 : Remove paper from Lithium battery when installing Note2 : If using standby battery on UNC100 DC voltage in must be 13.5 to 13.8 volts to properly charge the standby battery TX: Flashing = RS485 Normal RX: Controllers 2 thru 15 online RUN: Flashing = Normal HOST: Flashing Red = Host is Polling Flashing Green = Controller reply Flashing red and Green = Normal TROUBLE: Off = Normal UNC 100 Panel 2 Panel 16 Panel Network # 1 Panel Network # 32 RS-485 Bus Up to 4,000’ LAN / WAN / INTERNET Client # 2 Client # 10 Integra32 Server Up to 9 simultaneous clients: Up to 32 simultaneous connections to Server (panel networks) Only ONE Server! Thin and Web clients are available for Internet connections Up to 64 doors (32 x 2-door panels or 16 x 4-door panels) per Integra32 Server Up to 32 doors (16 x 2-door panels or 8 x 4-door panels) per Panel Network Client # 3 (Includes 1 client) Panel 2 Panel 16 UNC 100 Panel Network # 2 LAN / WAN / INTERNET JP3 on Circuit Board IN POWER OUT Address SW1 SW2 SW3 SW4 1 X O O O 2 O X O O 3 X X O O 4 O O X O 5 X O X O 6 O X X O 7 X X X O 8 O O O X 9 X O O X 10 O X O X 11 X X O X 12 O O X X 13 X O X X 14 O X X X 15 X X X X Denotes 12vdc in or 12vdc out when using POE A. UNC100 and PC are on the same subnet: UNC : XXX.XXX.ZZZ.AAA PC : XXX.XXX.ZZZ.BBB To configure UNC100 type in it’s address into web browser. B. UNC100 and PC are on the same net, different subnets: UNC: XXX.XXX.ZZZ.AAA PC : XXX.XXX.YYY.BBB Use IPLocator to detect UNC100 and change it’s IP address, go to A C. UNC100 and PC are on different nets and/or subnets: Manually set your PCs IP address to match net/subnet of the UNC100, go to A to configure UNC100.

Transcript of Server : Installs Server and Client on one PC only (Setup...

Page 1: Server : Installs Server and Client on one PC only (Setup ...training.rbh-access.com/downloads/RBH_Integra32_Install_Sheet2013.… · UNC: XXX.XXX.ZZZ.AAA PC : XXX.XXX.YYY.BBB Use

Server : Installs Server and Client on one PC only (Setup.exe)Communications Modules : USB Drivers and utilities Documents : All manuals in PDF formatClient : Installs Client (Setup.exe)Firmware: Various Firmware FilesUpdate: Service packs (if needed)Adobe Acrobat Reader Included on DVD

TIP: To configure the IP address of the RBH-UNC100-XXX use the ‘Device Discovery’ tool built into the Integra32 software. Install the Integra32 software… Login…go to tools menu… select ‘Device Discovery’ . Choose the proper network card and select search… any controllers on the network segment will be displayed. Select the desired controller and edit….enter the IP address and select ok. The default password is ‘password’.

License : Feature KeyWeb : Web Server InstallerDVR : Integration PacksFingerprint : Integration Packs

THIS DOCUMENT IS FOR QUICK REFERENCE ONLY, REFER TO HARDWARE & SOFTWARE MANUALS FOR FULL DETAILSProcessor: Intel Core 2 Duo or betterMemory: 1-2 GB depending on OSStorage: 20 GB, or more if neededDVD-ROM, Ethernet Port, USB portsOperating System: WindowsEditions: Pro, Business, Ultimate 32 Bit: Windows 7, 8, Server 2003, 2008 64 Bit: 7, 8, Server 2008

Integra32

ServerUNC100

Static LAN IP AddressRequired for UNC

Static Internet IPAddress for Router

Router on siteBroadband Modem

CAT5 (300’ Max.)

Port Forwarding - Configure Router to forward designated IP port on Internet IP address (as entered in Integra32) to a port on Local Network (UNC100). Example: In Integra32 software set 5.6.23.7 port 75. On remote router forward remote site port 75 on 5.6.23.7 to UNC100 on port 3002 on 192.168.1.125

CAT5

RBH does not provide tech support on port forwarding!

Internet

PC to Router to Internet to Router to Controller

INTE

RNET

CONT

ROLL

ER W

ITH

LAN

GATE

WAY

- UN

C100

OVER

VIEW

DVD

CONT

ENTS

PC S

PEC

Note1 : Remove paper from Lithium battery when installing Note2 : If using standby battery on UNC100 DC voltage in must be 13.5 to 13.8 volts to properly charge the standby battery

TX: Flashing = RS485 NormalRX: Controllers 2 thru 15 online

RUN: Flashing = Normal

HOST: Flashing Red = Host is PollingFlashing Green = Controller replyFlashing red and Green = Normal

TROUBLE: Off = Normal

UNC100

Panel2

Panel16

Panel Network # 1

Panel Network # 32RS-485 BusUp to 4,000’

LAN / WAN /INTERNET

Client # 2

Client # 10

Integra32

Server

Up to 9 simultaneous clients: Up to 32 simultaneous connections to Server (panel networks) Only ONE Server!

Thin and Web clients are available for Internet connectionsUp to 64 doors (32 x 2-door panels or 16 x 4-door panels) per Integra32 Server

Up to 32 doors (16 x 2-door panels or 8 x 4-door panels) per Panel Network

Client # 3

(Includes 1 client)Panel2

Panel16

UNC100Panel Network # 2

LAN / WAN /INTERNET

JP3 on Circuit Board

IN

POWER

OUT

Address SW1 SW2 SW3 SW4

1 X O O O

2 O X O O

3 X X O O

4 O O X O

5 X O X O

6 O X X O

7 X X X O

8 O O O X

9 X O O X

10 O X O X

11 X X O X

12 O O X X

13 X O X X

14 O X X X

15 X X X X

Denotes 12vdc in or 12vdc out when using POE

A. UNC100 and PC are on the same subnet:UNC : XXX.XXX.ZZZ.AAA PC : XXX.XXX.ZZZ.BBBTo configure UNC100 type in it’s address into web browser.

B. UNC100 and PC are on the same net, different subnets:UNC: XXX.XXX.ZZZ.AAA PC : XXX.XXX.YYY.BBBUse IPLocator to detect UNC100 and change it’s IP address, go to A

C. UNC100 and PC are on different nets and/or subnets:Manually set your PCs IP address to match net/subnet of the UNC100, go to A to configure UNC100.

Page 2: Server : Installs Server and Client on one PC only (Setup ...training.rbh-access.com/downloads/RBH_Integra32_Install_Sheet2013.… · UNC: XXX.XXX.ZZZ.AAA PC : XXX.XXX.YYY.BBB Use

OUTP

UTS

RTE : to keep door unlocked we need re-triggering of RTE input (Each trigger extends unlock timer)

DC : N.O. sensors are wired in parallel, N.C. sensors in series

Wiring : Up tp 1,000’ on 18-22 AWG 2-Cond. cable

SUPP

ORT

READ

ERS

INPU

TSAC

CESS

POI

NTS

For Support Call : 201-663-9070 / Option 1

Web site : www.rbh-access.comE-mail : [email protected]

RTEInstalled

DCInstalled

Lock by timer

Lockon door close

Door Forced

Door Held Open

Yes Yes Yes Yes Yes YesNo Yes Yes Yes No* YesNo No Yes No No No

RTE : Request to Exit, typically motion detector, crash bar, exit button - Shunts door contact and unlocks door for exitDC : Door Contact (a.k.a. door switch, DSM) - Monitors whetherthe door is opened or closedReader : Card, Fingerprint Reader with/or keypad with Wiegand Interface - Reads user credentials, PINs, etc.Lock : Electric strike, lock set, magnetic lock or any electrically actuated device - secures an access pointAccess Point : Door, gate, turnstile, any point with secured access

RTE

R

DC

L

AccessPoint

* Will activate every time door is opened to exit, you can turn “Disable Door Forced Open” feature on

“ON State”Setting

OperationType

“Output Off”Relay is:

“Output On” Relay is:

N.O.Mark

N.C. Mark

Energized Fail-Secure Off On N.O. N.C.

De-energized Fail-Safe On Off N.C.* N.O.*

Lock

* Functionality of relay polls will be reversed vs. printed marking

Relay Outputs (Marked #N.O./#N.C./#C): Maximum rating 5A @ 30V, Dry, Form “C” relay

Voltage Outputs (Marked #OC) : 100mA, -12VDC, for solid state devices only (LED, Piezo, etc.)N.O.N.C. COC

+

+ -12V 0V

LED

Marking

INSTALL DIODE on DC powered locks! 1N4007 Diode installed at the lock will prevent damage to the controller. Please, use MOVs (metal oxide varistors) for AC powered locks.

Diode 1N4007White stripe to +

NO LOCKS! on OC outputs

Supervision type

Detects state changes:

Supervised secure

Supervised in alarm

None Yes No No.1 Resistor Yes Yes No2 Resistor Yes Yes Yes

MarkingCircuit Type: Normally Closed Normally Open N. C. 1 Resistor N. O. 1 Resistor N. C. 2 Resistors N. O. 2 Resistors N. C. & N.O. 1 Resistor

Open Alarm Restore Alarm Trouble Trouble Trouble TroubleShort Restore Alarm Trouble Alarm Trouble Trouble Alarm

1K N/A N/A Restore Restore Restore Alarm Restore2K N/A N/A N/A N/A Alarm Restore N/A

Circuit State Default

1K Resistor Color code: Brown Black Red / Gold: 5% tolerance

Complete database is stored on the Server PC, cards and settings are transferred to the

panel during the download. Panel retains this data and operates independently, sending

events to Server and receiving commands from it. It is not possible to “upload” hardware

configuration or card database from the panel. Please configure Integra32 Server’s built in backup function to preserve your data in case of PC failure!

Function RBH HID AWID TerminalLED Brown Orange Brown GRN

Buzzer Blue Yellow Yellow BUZData 0 Green Green Green D0Data 1 White White White D1

Ground Black Black Black 0VPower Red Red Red 12V

Reader LED StatusRed Locked

Green Unlocked

Blinking “High Security” Mode

Reader Sounder EventLong Beep Access Granted

Two Short Beeps Access DeniedFour Beeps Mode Changed

Beeping DHO Warning or PIN request

Continuously On Door Forced or Door Held Open Alarm

See reader manual for actual color codes!

RED GRN BUZ D0 D1 0V 12V

To EXIT Reader

GRN RED BUZ D0 D1 SIG 0V 12V

To ENTRY Reader

To Controller

RBH-EXITRDR

EXITRDR : This module allows reporting of direction on doors

with readers installed on both sides, while using a single

reader port on the controller (RBH reader wiring shown)

Wiring : Up to 500’ Max from Reader to Panel on 18 AWG 6-Cond. Shielded Cable

THIS DOCUMENT IS FOR QUICK REFERENCE ONLY, REFER TO HARDWARE & SOFTWARE MANUALS FOR FULL DETAILS

NOTE

S

-