Server Communication Network Switch High Density

• Modular server cabinet platforms offering a wide variety of sizes, configurations and versatility

• Passive and active cooling configurations and options

• Industry leader in modifications and non-standard requirements

• Communication/patch cabinets accommodate high-density cables, patch cords and equipment

• Feature two full-length vertical cable managers in the front of the cabinet

• Designed specifically for network switches like CISCO’s 6509 and 6313, with unique right to left airflow ducting

• Modifications available to accommodate Nexus 7000

• Robust cable management

• VARISTAR LHX air/water heat exchangers deliver closed-system cooling, dissipating up to 40 kW of heat per cabinet

• Lowest energy consumption and noise levels

• Vertical configuration of cooling unit provides up to 20% more server space

• Narrow footprint

The Hoffman Advantage

Why does over 50% of the Fortune 500 trust Hoffman protection?

Networking cabinets from Hoffman do more than protect your IT equipment, they protect your advantage by ensuring reliable performance and maximizing service life, improving productivity and reducing maintenance demands. Advanced features address thermal, cable and power management. World-class design, higher thermal capacities and more options and configuration possibilities deliver nothing less than the optimal solution for your equipment. Faster availability, deep engineering expertise and complete program management ensure proper staging and deployment of complex projects.

Solutions for any IT application

• Large line of standard solutions with a wide array of modifications and co-development solutions

• Server, communication and network switch cabinets designed for scalability and compatibility with present and future components

• Comprehensive options including latching/security, cable management, thermal/cooling and power/PDU solutions

• Leader in thermal, cable and power management solutions

• Dedicated solutions for colocation, voice/data, hot/cold aisle, liquid-cooled, containment and NEMA-rated applications

2

Page 3: Server Communication Network Switch High Density - Hoffman: Home

Thermal Performance Optimized Server Cabinets

PROLINE® FLOTEK™ Server Cabinet Series

Designed deeper to house servers and manage power cables, PROLINE® FLOTEK™ Cabinets rely on optimized passive airflow for thermal management. The cabinets may be placed in data rooms randomly or in hot/cold aisle configurations.

FLOTEK™ Models:

• PC (Passive Cooling)

• HCA (Hot/Cold Aisle) Server Cabinet

• FD (Floor Ducted) Server Cabinet

Features:

• Fully perforated front and rear doors and on top allow maximum air movement around equipment; conforms to server manufacturer open space requirements (70% openings)

• Extruded aluminum and formed perforated steel styling offers aesthetic styling

• Models without side panels gang together quickly for easy data center installation

• Three-point locking pushbutton swing handle provides security

• Rear doors are split for easy access and include 3-point, low-profile, locking swing handle

• Two sets of 19-in. rack angles support front and rear of equipment; infinitely adjustable from front to rear for positioning flexibility

• Large top gland plate allows easy routing of cable, pre-terminated cables and patch panels. Perforated tops on passive cabinets and solid tops on HCA cabinets.

• Welded frame construction

• Ability to personalize the cabinet for unique thermal, cable and power management solutions

Common models (See Networking Catalog for complete listings)model size (mm) Rack Units notes

PSCPC20610B 2000 x 600 x 1000 42 Passive Cooling

PSCPC20612B 2000 x 600 x 1200 42 Passive Cooling

PSCHCA20610B 2000 x 600 x 1000 42 Hot Aisle/Cold Aisle w/fans

PSCHCA20612B 2000 x 600 x 1200 42 Hot Aisle/Cold Aisle w/fans

Rear View

Rear View

PC

HCA

FD

3

server

Rear View

PROLINE® Cabinets come standard with an adjustable, foam-lined gland plate cable entry to maintain a dust-tight seal

Page 4: Server Communication Network Switch High Density - Hoffman: Home

Thermal Management: Server Class Applications

How much does heat build-up affect equipment?

Heat build-up diminishes server performance and equipment lifespan. For every 18° F (10° C) that internal cabinet temperatures rise above normal room temperature, the life expectancy of the enclosed electronics drops 50%.*

* SOURCE: The Uptime Institute

Thermal Management Strategies

Thoughtful data center layout and cabinet design can significantly affect thermal management efficiencies. In Hoffman’s thermal test lab, engineers have tested a full range of cabinet designs, cooling systems and data center configurations to incorporate the most efficient cooling strategies into our cabinets:

Passive: Relies on cabinet openings (vents, louvers or perforated panels) and equipment fans to exchange ambient air.

Active: Venting fans within the cabinet are used to exhaust hot air. This method may also incorporate chilled air fed into the cabinet.

Chimney: Utilizes ducting to remove hot air back to the CRAC unit.

Hot Aisle/Cold Aisle: Layout uses the concept of thermal zones to manage intake and exhaust air.

Passive CoolingActive - Hot/Cold Aisle

ChimneyFloor Ducted

4

Thermal Management White Paper

Learn more about effective thermal management strategies including cabinet design, data center layout, and passive and active cooling strategies. E-mail [email protected] to request our Thermal Management White Paper.

PROLINE® Passive

PROLINE® Random Active

MORE COOLINg

Page 5: Server Communication Network Switch High Density - Hoffman: Home

High Density Containment

Hoffman’s VARISTAR cabinet platform and an LHX series air/water heat exchanger combine to deliver the ultimate containment solution for high-density equipment. Flexible and scalable, VARISTAR Cabinets can be deployed and re-deployed into hot or cold aisle configurations, providing active heat dissipation of up to 40,000 W and noise levels of less than 55 dB(A).

CONTINuuM OF COOLINgHoffman offers a progression of server cabinets designed to balance the thermal load of your devices, ensuring optimum performance and service life. From standard passive cooling features that inherently dissipate heat, to active, ducted and air conditioned solutions that maintain proper operational temperatures in high-density environments, Hoffman gives you the tools to calculate your thermal load and the models to meet your equipment requirements as well as your data center configuration.

Hot Aisle Containment

Hot/Cold Aisle

Cold Aisle Containment

M O R E H E A T5

PROLINE® Hot/Cold Aisle• 6 rear cabinet fans

PROLINE® Floor Ducted

PROLINE® Chimney

VARISTAR Liquid Cooled• 40,000 watts

VARISTAR Containment

MORE COOLINg

server

Page 6: Server Communication Network Switch High Density - Hoffman: Home

6

Thermal Management: High Density Server Cabinets

PROLINE® Chimney

Hoffman’s passive cooling chimney solutions are extremely efficient for applications up to 20kW. Direct-duct solutions are key to many green data center initiatives.

• Perforated front door ensures proper equipment intake airflow and a solid rear door prevents hot exhaust air from escaping out the back

• Filler panels should be utilized in front to eliminate bypass airflow around equipment

• Adjustable vertical exhaust duct is located on top to direct hot exhaust out of the cabinet back to the cooling system or CRAC unit

• Exhaust duct is typically connected to the ceiling plenum return; however, this is not necessary if the data center has high ceilings which can provide a sufficient return path

Benefits:

• Cabinets do not have to be arranged in the typical HACA configuration. There is more freedom for flexible arrangements.

• Floor tiles do not need to be dedicated to cabinets. By managing the exhaust airflow, hot spots are eliminated so the cabinet can pull air from anywhere in the data center.

• Provides a better design for non-raised floor data centers

• Allows higher set-points on CRAC units and creates higher hot temperature returns, which improves efficiency of air conditioners

serverManaging Exhaust Airflow

Hoffman’s PROLINE® Chimney solution exhausts hot air from the cabinet directly into the ceiling plenum, eliminating the problem of hot air recirculation. This very simple, cost-effective approach provides enhanced cooling for your equipment.

Common models (See Networking Catalog for complete listings)model size (mm) Rack Units notes

PSTD20610B 2000 x 600 x 1000 42 Passive-Chimney

PSTD20611B 2000 x 600 x 1100 42 Passive-Chimney

PSTD20612B 2000 x 600 x 1200 42 Passive-Chimney

Page 7: Server Communication Network Switch High Density - Hoffman: Home

Common models (See Networking Catalog for complete listings)model size (mm) Rack Units notes

DV218012LX2 2100 x 800 x 1200 42 Max Cooling 20kW

DV218012LX4 2100 x 800 x 1200 42 Max Cooling 40kW

7

Thermal Management: High Density Server Cabinets

As electronics become more powerful and are packaged more densely into ever-smaller devices, the demands for temperature control within high density cabinets has risen exponentially. Hoffman’s VARISTAR cabinet platform provides the ultimate solution for demanding thermal performance and protection where air cooling methods are insufficient or impractical. The active air/water heat exchanger technology offered in the VARISTAR platform provides optimal levels of cooling efficiency with appreciable energy cost savings.

VARISTAR Liquid Cooled Cabinet

Heavy duty cabinet with microprocessor-controlled LHX air/water heat exchanger offers more effective and more efficient cooling than is possible with air cooling methods.

• LHX unit dissipates up to 40 kW independent of environment; water-based cooling relieves “hot spots”

• 1200 mm depth accommodates all current server types and allows more space for cabling

• LHX unit is slotted into the left or right side of the cabinet leaving the 19-in. plane usable throughout its height (42U)

• Airflow elements and six fans installed across the entire height ensure a uniform level of heat removal from all components

Benefits:

• Cooling is integrated into an enclosed environment and allows users to monitor their cooling in a more targeted way

server

Page 8: Server Communication Network Switch High Density - Hoffman: Home

communications

8

Communications Cabinets: Server & Voice/Data

PROLINE® CONNECTEK™ Communications Cabinet:

CONNECTEK™ Cabinets are available in 700 mm and 800 mm widths to accommodate high-density cables, patch cords and networking equipment.

• Fully perforated top, front door and rear doors for maximum ventilation per server manufacturer open space requirements

• Two front cable managers with covers (see cable fill table below)

• Three-point locking swing handle on front door; rear doors are split for easy access via the 3-point, low-profile, locking handle

• Large gland plate in top allows easy routing of cable, pre-terminated cables and patch panels

• Two sets of rear cable managers are also provided

PROLINE® Communications Cabinets

PROLINE® Communications Cabinets are available in standard configurations to meet the essential protection needs for rack-mounted voice/data, switch and patch equipment. PROLINE cabinets feature a contemporary design with practical innovative features including CABLETEK™ Vertical Cable Managers, a top gland plate and perforated panels for maximum airflow. Hundreds of accessory and modification choices are available.

Common models (See Networking Catalog for complete listings)model size (mm) Rack Units notes

PnC2089B 2000 x 800 x 900 42 Communication Cabinet

PnC20810B 2000 x 800 x 1000 42 Communication Cabinet

PnC20811B 2000 x 800 x 1100 42 Communication Cabinet

PnC20812B 2000 x 800 x 1200 42 Communication Cabinet

PRolIne ConneCTeK – Front Vertical Cable manager Cable Fill Rates (per manager)

Cabinet Width Cross- sectional Area

Cable Fill Rate for Front Cable manager – each side @60% Fill

5E (0.22” Diameter)

6 (0.25” Diameter)

6A (0.30” Diameter)

700 mm 17.24” 272 210 146

800 mm 34.48” 544 421 293

Front Vertical Cable Manager

Page 9: Server Communication Network Switch High Density - Hoffman: Home

Common models (See Networking Catalog for complete listings)model size (mm) Rack Units notes

PnS20810 2000 x 800 x 1000 42 Passive-network Switch

PnS20811 2000 x 800 x 1100 42 Passive-network Switch

PnS20812 2000 x 800 x 1200 42 Passive-network Switch

9

Network Switch Cabinet

PROLINE® Network Switch Cabinet

Thermal Management

• Fully passive solution that provides a higher volume of pathways to provide cold air to the switch intake than any other switch cabinet in the market

• Specifically designed to support and meet the needs of CISCO 6500 and 9500 Series switches. Accessory kits allow you to modify the airflow to support the Nexus 7010 Series products. Exceeds CISCO airflow space requirements.

• Designed utilizing CFD Modeling software to monitor airflow within the cabinet

Cable Management

• Advanced cable management for both the front and rear sides of the network switch. Rear side cable management designed for handling cable bundles.

• Dual side cable managers provide the best solution to highlight your network investment by providing multiple pathways for routing and slacking cables

switch

PRolIne neTWoRK sWITCH – Front Vertical Cable manager Cable Fill Rates (per manager)

Cabinet Width Cross- sectional Area

Cable Fill Rate for Front Cable manager – each side @60% Fill

5E (0.22” Diameter)

6 (0.25” Diameter)

6A (0.30” Diameter)

800 mm 34.48” 544 421 293

Network Switch Thermal Management

A major challenge in data centers is preventing network switches with right to left airflow from providing hot air directly into other network equipment. Re-consuming hot air will greatly impact equipment temperatures. It is very important to utilize cabinet solutions that address this unique thermal issue. The Hoffman PROLINE Network Switch Cabinet is engineered to eliminate re-circulation of hot air and direct the hot air through the cabinet.

Page 10: Server Communication Network Switch High Density - Hoffman: Home

For Every Networking Challenge, Hoffman Has a Solution.

10

NET SEriES CAbiNETS PrOliNE® SErVEr CAbiNETS COMMuNiCATiONS SwiTCH CAbiNET HigH DENSiTy SErVEr CAbiNETS

Model Net Series PrOliNE® FlOTEK™ PC PrOliNE® FlOTEK™ HCA PrOliNE® FlOTEK™ FD PrOliNE® Server PrOliNE® AC PrOliNE® CONNECTEK™ PrOliNE® Sw Switch PrOliNE® Chimney VAriSTAr

Size range 49.00" x 23.52" x 34.00" to84.00" x 31.50" x 49.75"

72.28" x 23.62" x 35.43" to72.28" x 23.62" x 47.24"

72.28" x 23.62" x 35.43" to72.28" x 23.62" x 47.24"

82.30" x 23.62" x 35.43" to82.30" x 23.62" x 47.24"

50.75" x 23.62" x 35.36" to 82.30" x 23.62" x 47.18"

84.74" x 27.87" x 31.31" to 86.74" x 23.94" x 41.18"

78.28" x 27.56" x 35.43" to 78.28" x 31.50" x 47.24"

78.28" x 27.56" x 35.43" to 78.28" x 31.50" x 47.24"

72.28" x 23.62" x 35.43" to72.28" x 23.62" x 47.24" 82.68" x 31.5" x 47.24"

rack units (ru) 21 to 43 42 42 42 24 to 42 42 42 42 42 42

loading (Static) 1,000 lbs. 1,500 lbs. 1,500 lbs. 1,500 lbs. 1,500 lbs. 1,500 lbs. 1,500 lbs. 1,500 lbs. 1,500 lbs. 1,500 lbs.

watts Dissipated 500 to 1200 watts up to 6000 watts 15-20 kw up to 40kw

unique Features 19-in. or 23-in. rack spacing on 27.55 in. and 31.50 in. widths.

Provides maximum cooling without added fans for hot aisle/cold aisle and other data center configurations.

Ideal for hot aisle/cold aisle data center configuration in high-density applications.Rear split doors access separately powered fan banks for redundancy with easy equipment access.

Integrates raised floor cool air pathway to the network equipment. Raised floor cutout required.

Cabinet can be rolled into place, levelers positioned and anti-tip bracket attached. Anti-tip bracket, casters, levelers are standard. Plexiglass front door standard.

Fully sealed cabinet with provisions for AC unit (order separately). Mobile base with casters and levelers allows for best positioning.

Cabinet is designed for network communications.Includes front vertical cable managers with covers and rear vertical tie-down cable managers.

Cabinet is designed to house network core switches that have right to left airflows. Cabinet provides duct work to provide proper air streams to network core switches.CISCO version available.

Provides chimney-to-duct hot air exhaust from the cabinet into the ceiling plenum.

Integral water-to-air heat exchanger. Fully gasketed and sealed from all outside air.

body Features: Front & Back Door

Reversible, window or perforated front, split perforated or louvered rear, all with key locks

Perforated front, split perforated rear with key locking handle

Perforated front, split fan rear with key locking handle

Window front, split fan rear with key locking handle

Window perforated front, perforated rear with key lock

Fully gasketed front window door and rear solid door

Perforated front, split perforated rear with key locking handle

Perforated front, split perforated rear with key locking handle

Perforated front, split perforated rear with key locking handle

Fully gasketed front window door and rear solid door

Base Open Open with internal bolt brackets Open with internal bolt brackets Open base with floor duct, casters and levelers

Open with casters, levelers and anti-tip bracket

Mobile base with casters, levelers and gland plate

Open with internal bolt brackets

Open with internal bolt brackets

Open with internal bolt brackets

Plinth base with levelers

Top Fan-ready (two 6 in. fans) top with cable cap and grommet

Perforated with sliding gland plate for cable entry

Removable solid with sliding gland plate for cable entry

Removable solid with sliding gland plate for cable entry

Removable, fully perforated with cable entry cap and grommet

Fully gasketed solid top Removable perforated with sliding gland plate for cable entry

Removable perforated with sliding gland plate for cable entry

Top with integral adjustable duct work (chimney) and gland plate

Fully gasketed solid top

Rack Angles 2 sets Communications have tapped 10-32Server has square holeFront and back Ru markings

2 setsSquare holeFront and back Ru markings

2 setsSquare holeFront and back Ru markings

2 setsSquare holeFront and back Ru markings

2 setsSquare hole Front and back Ru markings

Server cabinets feature 2 sets of EIA spaced square holes. Communication cabinets have EIA spaced tapped holes. Front and back Ru markings

2 setsTapped hole 10-32Front and back Ru markings

1 set of rack angles tapped per EIA spacing. Top rear 4Ru rack angles tapped per EIA spacing.Front and back Ru markings

2 setsSquare holeFront and back Ru markings

2 setsSquare hole

Sides Removable with quarter-turn latch no sides or removable sides with 2 snap latches, quarter-turn key latch ready

no sides or removable sides with 2 snap latches, quarter-turn key latch ready

no sides or removable sides with 2 snap latches, quarter-turn key latch ready

Removable with 2 snap latches, quarter-turn key latch ready

Fully gasketed solid sides (2) attached with fasteners

no sides or removable sides with 2 snap latches,quarter-turn key latch ready

no sides or removable sides with 2 snap latches, quarter-turn key latch ready

no sides or removable sides with 2 snap latches, quarter-turn key latch ready

Fully gasketed solid sides (2) attached by fasteners

Applications General datacom computer room Data center Passive cooling

Data centerHot aisle/cold aisle

Data centerFloor ducted

Data center Factory floor, remote networking locationsDusty, dirty environments

Data centernetwork equipmentCommunications

Data centernetwork switch cabinet

Data center High density data centers and remotely located network applications

ratings RoHS compliantISO 9001EIA (rack spacing)

RoHS compliantISO 9001EIA (rack spacing)

RoHS compliantISO 9001EIA (rack spacing)

RoHS compliantISO 9001EIA (rack spacing)

RoHS compliantISO 9001EIA (rack spacing)

uL Type 12RoHS compliantISO 9001EIA (rack spacing)

RoHS compliantISO 9001EIA (rack spacing)

Type 1Meets CISCO third party enclosure requirementsRoHS compliantISO 9001EIA (rack spacing)

Type 1RoHS compliantISO 9001EIA (rack spacing)

IP 55, nEMA 12RoHS compliantISO 9001EIA (rack spacing)

Accessories Tool-less Shelf Snap-in blanking Panel Sliding Shelf rack Shelf

d19FVT69B600-900 mm depth

d19BPT1RU1 Ru snap-in panel

P19sHP810BL: 24.6 D: 41.3

P19VsH810B Vertical, BlackW: 17.3 L: 27.6 D: 38.6

d19FVT912B900-1200 mm depth

d19BPT2RU2 Ru snap-in panel

P19sH810B solid, BlackW: 17.3 L: 27.6 D: 38.6

Back

Back

Page 11: Server Communication Network Switch High Density - Hoffman: Home

NET SEriES CAbiNETS PrOliNE® SErVEr CAbiNETS COMMuNiCATiONS SwiTCH CAbiNET HigH DENSiTy SErVEr CAbiNETS

Model Net Series PrOliNE® FlOTEK™ PC PrOliNE® FlOTEK™ HCA PrOliNE® FlOTEK™ FD PrOliNE® Server PrOliNE® AC PrOliNE® CONNECTEK™ PrOliNE® Sw Switch PrOliNE® Chimney VAriSTAr

Size range 49.00" x 23.52" x 34.00" to84.00" x 31.50" x 49.75"

72.28" x 23.62" x 35.43" to72.28" x 23.62" x 47.24"

72.28" x 23.62" x 35.43" to72.28" x 23.62" x 47.24"

82.30" x 23.62" x 35.43" to82.30" x 23.62" x 47.24"

50.75" x 23.62" x 35.36" to 82.30" x 23.62" x 47.18"

84.74" x 27.87" x 31.31" to 86.74" x 23.94" x 41.18"

78.28" x 27.56" x 35.43" to 78.28" x 31.50" x 47.24"

78.28" x 27.56" x 35.43" to 78.28" x 31.50" x 47.24"

72.28" x 23.62" x 35.43" to72.28" x 23.62" x 47.24" 82.68" x 31.5" x 47.24"

rack units (ru) 21 to 43 42 42 42 24 to 42 42 42 42 42 42

loading (Static) 1,000 lbs. 1,500 lbs. 1,500 lbs. 1,500 lbs. 1,500 lbs. 1,500 lbs. 1,500 lbs. 1,500 lbs. 1,500 lbs. 1,500 lbs.

watts Dissipated 500 to 1200 watts up to 6000 watts 15-20 kw up to 40kw

unique Features 19-in. or 23-in. rack spacing on 27.55 in. and 31.50 in. widths.

Provides maximum cooling without added fans for hot aisle/cold aisle and other data center configurations.

Ideal for hot aisle/cold aisle data center configuration in high-density applications.Rear split doors access separately powered fan banks for redundancy with easy equipment access.

Integrates raised floor cool air pathway to the network equipment. Raised floor cutout required.

Cabinet can be rolled into place, levelers positioned and anti-tip bracket attached. Anti-tip bracket, casters, levelers are standard. Plexiglass front door standard.

Fully sealed cabinet with provisions for AC unit (order separately). Mobile base with casters and levelers allows for best positioning.

Cabinet is designed for network communications.Includes front vertical cable managers with covers and rear vertical tie-down cable managers.

Cabinet is designed to house network core switches that have right to left airflows. Cabinet provides duct work to provide proper air streams to network core switches.CISCO version available.

Provides chimney-to-duct hot air exhaust from the cabinet into the ceiling plenum.

Integral water-to-air heat exchanger. Fully gasketed and sealed from all outside air.

body Features: Front & Back Door

Reversible, window or perforated front, split perforated or louvered rear, all with key locks

Perforated front, split perforated rear with key locking handle

Perforated front, split fan rear with key locking handle

Window front, split fan rear with key locking handle

Window perforated front, perforated rear with key lock

Fully gasketed front window door and rear solid door

Perforated front, split perforated rear with key locking handle

Perforated front, split perforated rear with key locking handle

Perforated front, split perforated rear with key locking handle

Fully gasketed front window door and rear solid door

Base Open Open with internal bolt brackets Open with internal bolt brackets Open base with floor duct, casters and levelers

Open with casters, levelers and anti-tip bracket

Mobile base with casters, levelers and gland plate

Open with internal bolt brackets

Open with internal bolt brackets

Open with internal bolt brackets

Plinth base with levelers

Top Fan-ready (two 6 in. fans) top with cable cap and grommet

Perforated with sliding gland plate for cable entry

Removable solid with sliding gland plate for cable entry

Removable solid with sliding gland plate for cable entry

Removable, fully perforated with cable entry cap and grommet

Fully gasketed solid top Removable perforated with sliding gland plate for cable entry

Removable perforated with sliding gland plate for cable entry

Top with integral adjustable duct work (chimney) and gland plate

Fully gasketed solid top

Rack Angles 2 sets Communications have tapped 10-32Server has square holeFront and back Ru markings

2 setsSquare holeFront and back Ru markings

2 setsSquare holeFront and back Ru markings

2 setsSquare holeFront and back Ru markings

2 setsSquare hole Front and back Ru markings

Server cabinets feature 2 sets of EIA spaced square holes. Communication cabinets have EIA spaced tapped holes. Front and back Ru markings

2 setsTapped hole 10-32Front and back Ru markings

1 set of rack angles tapped per EIA spacing. Top rear 4Ru rack angles tapped per EIA spacing.Front and back Ru markings

2 setsSquare holeFront and back Ru markings

2 setsSquare hole

Sides Removable with quarter-turn latch no sides or removable sides with 2 snap latches, quarter-turn key latch ready

no sides or removable sides with 2 snap latches, quarter-turn key latch ready

no sides or removable sides with 2 snap latches, quarter-turn key latch ready

Removable with 2 snap latches, quarter-turn key latch ready

Fully gasketed solid sides (2) attached with fasteners

no sides or removable sides with 2 snap latches,quarter-turn key latch ready

no sides or removable sides with 2 snap latches, quarter-turn key latch ready

no sides or removable sides with 2 snap latches, quarter-turn key latch ready

Fully gasketed solid sides (2) attached by fasteners

Applications General datacom computer room Data center Passive cooling

Data centerHot aisle/cold aisle

Data centerFloor ducted

Data center Factory floor, remote networking locationsDusty, dirty environments

Data centernetwork equipmentCommunications

Data centernetwork switch cabinet

Data center High density data centers and remotely located network applications

ratings RoHS compliantISO 9001EIA (rack spacing)

RoHS compliantISO 9001EIA (rack spacing)

RoHS compliantISO 9001EIA (rack spacing)

RoHS compliantISO 9001EIA (rack spacing)

RoHS compliantISO 9001EIA (rack spacing)

uL Type 12RoHS compliantISO 9001EIA (rack spacing)

RoHS compliantISO 9001EIA (rack spacing)

Type 1Meets CISCO third party enclosure requirementsRoHS compliantISO 9001EIA (rack spacing)

Type 1RoHS compliantISO 9001EIA (rack spacing)

IP 55, nEMA 12RoHS compliantISO 9001EIA (rack spacing)

Accessories Tool-less Shelf Snap-in blanking Panel Sliding Shelf rack Shelf

d19FVT69B600-900 mm depth

d19BPT1RU1 Ru snap-in panel

P19sHP810BL: 24.6 D: 41.3

P19VsH810B Vertical, BlackW: 17.3 L: 27.6 D: 38.6

d19FVT912B900-1200 mm depth

d19BPT2RU2 Ru snap-in panel

P19sH810B solid, BlackW: 17.3 L: 27.6 D: 38.6

Cage Nuts Screw Kit Floor brushes PDu - Horizontal/Vertical

10-32, silver 10-32 x 5/8", silver

P1032Cn20 qty

As103220 qty

dFB410F

Complete list of PDUs can be found in the

Hoffman Networking Catalog

dFB57F

P1032Cn250250 qty

As1032250250 qty

dFB66s

dFBA1024F

Back

11

Page 12: Server Communication Network Switch High Density - Hoffman: Home

powerHow much power and protection is required?

The more equipment in a cabinet, the more circuits and outlets you need. Hoffman provides power supply and distribution strategies oriented to your equipment configuration. A wide range of rack-mount single and three-phase power distribution units (PDUs) provides different surge protection and outlet configurations. Hoffman Smart PDU components offer embedded intelligence options and remote sensors for complete PDU and environmental monitoring.

Power Management

12

Intelligent power, where you need it:

• IT-compliant branch circuit protection that meets both National Electric Code and UL 60950-1 standards

• Multi-form factor 2U, 1U and zero U configurations; horizontal and vertical in many different lengths

• Single and three-phase models in metered and non-metered power strips

• Smart PDU components include amp-metered, switching and monitoring; remote power management and IP addressable units that can be programmed and controlled online from a computer, PDA or WAP terminal

Ability to remotely monitor up to 16 environmental sensors such as temperature, airflow, humidity, smoke, water and door alarms.

Environmental Monitor

Single- and Three-Phase

Horizontal PDUs

Single- and Three-Phase Vertical PDUs

Smart PDUs

Page 13: Server Communication Network Switch High Density - Hoffman: Home

How is uptime affected by cabling configuration?

Defining cable pathways is more than aesthetics— a properly configured cabling environment eliminates potential kinks, twists and sharp bends to ensure maximum signal quality and transmission speed. It’s safer, and it supports faster, easier system MACs (moves, adds, changes) facilitated by easier cable tracing. Hoffman cabinets provide a host of features that help you route and organize cabling for maximum flexibility, performance and protection.

Configure your cable management solution:

• Vertical cable managers with optional covers and doors secure large cable bundles and guide individual cables

• Horizontal cable managers with troughs; optional covers

• CABLETEK Horizontal and Vertical Managers with high-capacity fingers offer tool-less mounting and optimal bend radius for CAT 5e, 6, 6A

• Front-to-back cable managers

• Spools, fingers, tie-down points, D-rings, cable ties and transition brackets to meet specific requirements

• Gland plate top with cable entry facilitates quick installation of large cable bundles

• Multiple cable supports to ensure transitions to vertical pathways

• Fingers align with rack spaces to ensure proper bend radius

Cable Management

13

Cable Trough available for rack angle mounting, top or bottomECT19

cable

INDUSTRY-LEADER in Cable Management Solutions

Cable and PDU ManagerPVCPM20

CABLETEK™ Vertical Cable

ManagerPVF208

Strut Cable RingsECM4S10

Frame Tie-Down BracketPCMFTD10

Page 14: Server Communication Network Switch High Density - Hoffman: Home

specialtyHoffman cabinets are as limitless as your needs and imagination. To address specialty IT needs, and those of networking in extreme environments, no one has more to offer than Hoffman. A large number of specialty cabinets are available standard with a large array of accessory items to solve your application challenges. In addition, virtually all models can be modified to meet enhanced requirements.

Specialty Application Cabinets

14

PROLINE®-CL Colocation Cabinets

PROLINE®-CL Colocation Cabinets are designed for secure data centers that store computer equipment for multiple customers. Standard components allow cabinets to be configured with up to four separate, secure compartments that can be reconfigured on-site as needs change. Each compartment has its own front and back access and is passively cooled by virtue of the overall cabinet design.

PROLINE® NEMA-Rated AC Cabinets

PROLINE® AC Cabinets offer integrated air conditioners, sized to meet your specific cooling requirements. Air conditioned models provide closed loop cooling for equipment that must be kept at or below ambient temperatures for optimal performance. This protects the electronic controls and prevents shutdowns caused by heat, humidity, dust and other contaminants.

Seismic Cabinets

NEBS™-Telcordia GR-63-CORE Zone 4-rated Seismic Cabinets provide an extra measure of protection for vital LAN and WAN network equipment, servers and phone/voice mail equipment during seismic activity. In addition, Seismic Cabinets are also used in power plants, railroads, airports and other installations where rack-mounted electrical and electronic equipment is subjected to vibration and other motion that can over-stress equipment framework, components and connections. The cabinet’s passive cooling design can be augmented with optional fans.

Networking PC Cabinet, Type 1

Used for remote network access from a factory floor or warehouse, the Networking PC Cabinet is built to house PCs, keyboards and printers for data entry as well as LAN and WAN equipment. Key-lock doors provide security and physical protection for equipment that is passively cooled by air taken in from the rear of the cabinet and expelled through fan cutouts in the top. Optional fans may be installed for added cooling.

PROTEK® DH Double-Hinged Thermal Package, uL and NEMA Type 4 or 12

Type 4 and Type 12 PROTEK Double- Hinged Cabinets are ideal for protecting 19-inch network equipment from falling dirt, splashing water, dust and other contaminants with the convenience and space efficiency of pole- or wall-mounting. A thermal package provides air conditioned cooling of components within a sealed environment that maintains the NEMA rating.

SOHO Cabinet

SOHO (Small Office and Home Office) Cabinets are designed to house servers, networking equipment and phone and voice mail equipment under a desktop. Casters allow the cabinet to be easily moved for access. Equipment is passively cooled by air taken in from the front of the cabinet and expelled through fan cutouts in the rear, which can accept optional fans for warmer applications.

NEBS™ is a trademark of Telcordia

Page 15: Server Communication Network Switch High Density - Hoffman: Home

world-Class Protection. built-to-Order.

15

For over 60 years, no one has more experience protecting critical systems than Hoffman. Producing over 10 million enclosures and accessories every year, Hoffman has the manufacturing capabilities and capacity to deliver proven, tested and robust networking enclosure solutions for any size deployment on any schedule. And the experience to ensure our enclosures provide years of operational integrity in the world’s most demanding networking environments.

We have you covered. Learn how.

Your local Hoffman representative has the best answers to your network protection challenges. With thousands of standard products including free-stand and wall-mount cabinets, racks, wireway and cable tray, cooling solutions, and hundreds of accessory items and configuration options including mounting, cable management, power distribution units (PDUs), passive and active cooling, shelves, monitor arms and more.

Contact your Hoffman representative for a no-obligation presentation and to learn how Hoffman can protect your infrastructure like no other.

Go to hoffmanonline.com or call (763) 422-2261.

Standard• The industry’s largest selection of standard products and accessories

• Complete solutions for data centers, remote networking in demanding environments, telecommunications and outdoor applications

• #1 in cable, thermal and power management solutions

Modifications• The largest selection of fast-turn modifications to our standard products

• Maintain NEMA, UL/cUL and CSA ratings; in-house UL certified test lab

• Easy to accommodate unique dimensions and integrate cable, power and thermal management

• Ability to personalize your network enclosure

Custom• Co-developed solutions based upon customer’s requirements

• Large engineering staff and decades of experience in design and fabrication

• The industry’s largest manufacturing capacity and capabilities

• OEM programs• Design, engineering, integration, program

management, prototyping, fabrication, testing, and thermal and power management

Page 16: Server Communication Network Switch High Density - Hoffman: Home

HOw CAN wE HElP yOu? hoffmanonline.com

Protecting technology assets in the world’s most demanding IT environments.

Your organization depends on information and the ability to communicate. So protecting your networking equipment is vital. To keep your systems functioning smoothly and reliably, turn to Hoffman for technology protection solutions. No enclosure provider responds faster to the changing technology landscape, with a wider selection of products, to a broader array of industries.

For more than 60 years, Hoffman has protected the essential infrastructure of industries worldwide— across the spectrum of electrical, electronic and networking applications. We define excellence in enclosures with thousands of offerings in every shape and size, tailored to even the most complex applications and demanding challenges. And we provide service like no other with our highly trained distributor network. Simply put, Hoffman has the most solutions, because we have the most selection and the most experience to meet your needs.

©2009 Hoffman Enclosures Inc. Bro-00015 D

USA – Global Headquarters2100 Hoffman WayAnoka, Minnesota 55303-1745 U.S.A.Tel: 763-422-2661Fax: 763-422-2588Customer Service: 763-422-2661Networking E-mail: [email protected]

BrazilPentair Technical Products Brazil(Taunus Metalurgica LTDA)Rua Joao Marcon, 16518550.000 – CentroBoituva – SP

CanadaHoffman Enclosures Inc.111 Grangeway Avenue, Suite 504Scarborough, Ontario M1H 3E9Tel: 416-289-2770Fax: 416-289-28831-800-668-2500 (Canada only)

ChinaPentair Technical ProductsChina Manufacturing HeadquartersAir Port Industrial ZoneShuangYuan Road WestChengYang City, Qingdao PC 266108

Pentair Technical ProductsChina Sales Headquarters21st Floor of Cloud Nine PlazaNo. 1118 West Yan‘an RoadChangning District, Shanghai P.R. China

EuropePentair Technical Products EuropeLangenalber Strasse 96-100Straubenhardt, Germany D-75334

Pentair Technical Products Poland Sp. z o.oul. Strefowa 10PL 58-200 Dzierzoniów

IndiaPentair Technical Products India Pvt. Ltd.Unit 1, Shed 2 (Sai Lakshmi Industrial Campus)Kannamangala, Bidarahalli HobliWhitefield – Hoskote RoadBangalore – 560067

MexicoHoffman Enclosures Mexico,S. de R. L. de C. V. Arquímedes No. 33, Piso 1Col. Palmas PolancoMexico, DF CP 11560Tel: (55) 5280-1596Fax: (55) 5280-8827 / 5280-8167

For worldwide locations, see hoffmanonline.com

1

1514

13

234 5

67

8

9

10 11 12

Anoka, MN

Champlin, MN

Schaumberg, IL

Mt. Sterling, KY

Radford, VA

Warwick, RI

Poway, CA

Reynosa, Mexico

Boituva, Brazil

Betschdorf, France

Straubenhardt, Germany

Dzierzoniow, Poland

Bangalore, India

Qingdao, China

Yokohama, Japan15

13

4

5

6

7

8

9

10

11

12

2

1

3

14

Strategic Manufacturing Locations