SERIA L NU MBER SERIAL NUMB R Junctiun on Boon x · Cuts Night, Breaks Dawn. TM Cuts Night, Breaks...

2
Mechanical Specifications Electrical Characteristics Temperature Characteristics Packing Configuration Pieces per Pallet Pallets per Container Pieces per Container Container External Dimensions Weight Solar Cells Front Glass Frame Junction Box Output Cable Connector Mechanical Load 1690 x 1002 x 35 mm 19.0kg PERC Mono crystalline158.75 × 79.375 mm(120pcs) 3.2 mm AR coating tempered glass, low iron Anodized aluminium alloy IP68, 3 diodes 4.0 mm²,Portrait:255mm(+)/355mm(-);Landscape:1200mm MC4 Compatible Front side 5400Pa/ Back side 2400Pa -0.36 %/°C -0.28 %/°C +0.05 %/°C -40+85 °C 45±2 °C I-V Curve [email protected] www.seraphim-energy.com Add: No.1-2, HengyaoRd, HenglinTown, Wujin District, 213000, Changzhou, China Tel: +86-519-69699879 Fax: +86-519-88786181 Email: [email protected] TM Cuts Night, Breaks Dawn. 320W-335W Cuts Night, Breaks Dawn. TM 1690 x 1002 x 35 mm STC: lrradiance 1000 W/m² module temperature 25°C AM=1.5; (0,+4.99) 1000 VDC / 1500 VDC 20A SRP-325-BMB SRP-325-BMB-HV SRP-330-BMB SRP-330-BMB-HV SRP-335-BMB SRP-335-BMB-HV Maximum Power at STC (Pmp) Open Circuit Voltage (Voc) Short Circuit Current (Isc) Maximum Power Voltage (Vmp) Maximum Power Current (Imp) Module Efficiency at STC(ηm) Power Tolerance Maximum System Voltage Maximum Series Fuse Rating Module Type STC 325 40.6 10.02 34.2 9.51 STC 335 41.0 10.20 34.6 9.69 19.19 STC 330 40.8 10.11 34.4 9.60 19.49 19.78 SRP-320-BMB SRP-320-BMB-HV STC 320 40.4 9.93 34.0 9.42 18.90 -HV SRP-XXX-BMB: Maximum System Voltage1000 VDC SRP-XXX-BMB-HV: Maximum System Voltage1500 VDC 0 10 20 30 40 50 Voltage [V] 0 2 4 6 8 10 12 Current [A] Incident Irrad. = 1000 W/m² Cells temp. = 25 °C Incident Irrad. = 800 W/m² Incident Irrad. = 600 W/m² Incident Irrad. = 400 W/m² Incident Irrad. = 200 W/m² A A Grounding holes 2×Ø I 10±1 35±1 Section A-A 70 70 7 0 7 0 I 9 1 4 R4.5 5:1 II 2:1 10:1 Label SERIALNUMBER Mounting holes 35 3 5 2 0 0 ± 5 200±5 positive ( + ) negative ( - ) Junction Box 1 6 9 0 ± 2 1 4 1 0 ± 1 9 1 0 ± 1 1002±2 1 6 9 0 ± 2 1002±2 952±2 20’GP 40’GP 12 360 26 780 30 40’HQ 26 832 30+2* 30 * 30+2 pieces per pallet is the special package which only suits for container transport. For details,please consult SERAPHIM. 0 10 20 30 40 50 Voltage [V] 0 2 4 6 8 10 12 Current [A] Incident Irrad. = 1000 W/m² Cells temp. = 10 °C Cells temp. = 25 °C Cells temp. = 40 °C Cells temp. = 55 °C Cells temp. = 70 °C

Transcript of SERIA L NU MBER SERIAL NUMB R Junctiun on Boon x · Cuts Night, Breaks Dawn. TM Cuts Night, Breaks...

  • Mechanical Specifications

    Electrical Characteristics

    Temperature Characteristics

    Packing Configuration

    Pieces per Pallet Pallets per Container

    Pieces per Container

    Container

    External Dimensions

    Weight

    Solar Cells

    Front Glass

    Frame

    Junction Box

    Output Cable

    Connector

    Mechanical Load

    1690 x 1002 x 35 mm

    19.0kg

    PERC Mono crystalline158.75 × 79.375 mm(120pcs)

    3.2 mm AR coating tempered glass, low iron

    Anodized aluminium alloy

    IP68, 3 diodes

    4.0 mm²,Portrait:255mm(+)/355mm(-);Landscape:1200mm

    MC4 Compatible

    Front side 5400Pa/ Back side 2400Pa

    -0.36 %/°C

    -0.28 %/°C

    +0.05 %/°C

    -40~+85 °C

    45±2 °C

    I-V Curve

    [email protected]

    Add: No.1-2, HengyaoRd, HenglinTown, Wujin District, 213000, Changzhou, China Tel: +86-519-69699879 Fax: +86-519-88786181 Email: [email protected]

    TM

    Cuts Night, Breaks Dawn.

    320W-335W

    Cuts Night, Breaks Dawn.

    TM

    1690 x 1002 x 35 mm

    STC: lrradiance 1000 W/m² module temperature 25°C AM=1.5;

    (0,+4.99)

    1000 VDC / 1500 VDC

    20A

    SRP-325-BMB SRP-325-BMB-HV

    SRP-330-BMB SRP-330-BMB-HV

    SRP-335-BMB SRP-335-BMB-HV

    Maximum Power at STC (Pmp)

    Open Circuit Voltage (Voc)

    Short Circuit Current (Isc)

    Maximum Power Voltage (Vmp)

    Maximum Power Current (Imp)

    Module Efficiency at STC(ηm)

    Power Tolerance

    Maximum System Voltage

    Maximum Series Fuse Rating

    Module Type

    STC

    325

    40.6

    10.02

    34.2

    9.51

    STC

    335

    41.0

    10.20

    34.6

    9.69

    19.19

    STC

    330

    40.8

    10.11

    34.4

    9.60

    19.49 19.78

    SRP-320-BMBSRP-320-BMB-HV

    STC

    320

    40.4

    9.93

    34.0

    9.42

    18.90

    -HVSRP-XXX-BMB: Maximum System Voltage1000 VDC

    SRP-XXX-BMB-HV: Maximum System Voltage1500 VDC

    0 10 20 30 40 50Voltage [V]

    0

    2

    4

    6

    8

    10

    12

    Cur

    rent

    [A]

    Incident Irrad. = 1000 W/m²

    Cells temp. = 25 °C

    Incident Irrad. = 800 W/m²

    Incident Irrad. = 600 W/m²

    Incident Irrad. = 400 W/m²

    Incident Irrad. = 200 W/m²

    A A

    Grounding holes2×Ø

    I

    10±1

    35±1

    Section A-A

    70 70

    7070

    I

    9

    14

    R4.5

    5:1II

    2:1 10:1

    SERIAL NUMBER

    Label

    SERIALNUMBER

    Mounting holes

    35

    35

    200±

    5

    200±5

    positive ( + )negative ( - )Junction Box

    1690

    ±214

    10±1

    910±

    1

    1002±2

    1690

    ±2

    1002±2952±2

    SERIAL NUMBER

    Junction Box﹣ Junction Box﹣ Junction BoxJunction Box Junction Box ﹢Junction Box ﹢

    20’GP 40’GP

    12

    360

    26

    780

    30

    40’HQ

    26

    832

    30+2*30

    * 30+2 pieces per pallet is the special package which only suits for container transport. For details,please consult SERAPHIM.

    0 10 20 30 40 50Voltage [V]

    0

    2

    4

    6

    8

    10

    12

    Cur

    rent

    [A]

    Incident Irrad. = 1000 W/m²Cells temp. = 10 °CCells temp. = 25 °CCells temp. = 40 °CCells temp. = 55 °CCells temp. = 70 °C

  • Seraphim’s Blade™ Series solar module boasts two identical parts, which are composed of cells that are half the size of ordinary solar cells. By cutting cells into halves, these smaller currents will help reduce “Cell To Module” loss, which means higher output.

    In the meantime, the overall space between cells are doubled, and more light will be transferred into power through multiple reflections. Compared to mainstream standard modules, the Blade™ series module has lower current and series resistance which helps minimize mismatch loss, internal power loss, and shadow effect, etc. Once one cell has EL defect or appearance defect, such as black edge or V sharp. After cutting, one intact half can be reused.

    Instead of 6 internal strings of cells, the Blade series module has 2 x 6 shorter ones. This design effectively deals with the mismatchhappened between cells caused by shadow, out of sync performance degradation, ect.

    SRP-DS-EN-2020V1.0 | © Copyright 2019 Seraphim

    Blade™ – A Module re-Modeled

    Less Mismatch loss

    More Output Higher ROIHigher Efficiency

    With 6 internal strings of cells

    With 2 x 6 internal strings of cells

    Module current output is 8.7A, current mismatch in series is 0.3A.

    Module current output is 4.5+4.35=8.85A, current mismatch in series is 0.15A.

    Blade™

    Standard Module

    Design Sketch

    Design Sketch

    Circuit Diagram

    Circuit Diagram

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.5A

    4.5A 4.5A 4.5A 4.5A 4.5A 4.35A

    9A 9A 9A 9A 9A 9A

    9A 9A 9A 9A 9A 9A

    9A 9A 9A 9A 9A 9A

    9A 9A 9A 9A 9A 9A

    9A 9A 9A 9A 9A 9A

    9A 9A 9A 9A 9A 9A

    9A 9A 9A 9A 9A 9A

    9A 9A 9A 9A 9A 9A

    9A 9A 9A 9A 9A 9A

    9A 9A 9A 9A 9A 8.7A

    Cuts Night, Breaks Dawn.

    TM

    Cuts Night, Breaks Dawn.

    TM

    Electrical Mismatch

    Electrical Mismatch

    Less Internal Power Loss

    By cutting solar cell into halves, the internal power loss will be lower and hot spot effect will also be reduced.

    The ribbon length of half-cell is shorter than normal cell. Calculated by Joule's law and Ohm' law, the power loss reduction is nearly 6%.

    Standard Cell Half Cell

    Higher Yield Due to Better Shading ResponseBlade™ comprises two separated and identical solar cell arrays, which means the ordinary strings of cells are cut into halves, and these shorter strings compose arrays which has separated current paths. When a module is shaded, only one side shaded array's current will be impacted, while the other array will still be functionally producing power. Under this circumstance, when a module is shaded, the affected working areas of Blade™ will be 50% less.

    Blade Module Standard Module TM

    Cut

    Warranty

    linear power output warranty

    Guarantee on productmaterial and workmanship

    15YEARS

    25YEARS

    100%

    97.5% 97.5%

    95.1%

    92.1%

    89.1%

    86.1%

    83.1%

    90%

    80%

    0 5 10 15 20 25

    Addtional Value from Linear Warranty

    Years

    Insurance

    Product Certificates