Sentry SamplingSystems
Sentry Equipment Corp.
Sentry Sampling Systems
Over 25 systems manufacturers worldwide Centralized stations are very common >6 Sample Lines- Standard Conditioning Rack <6 Sample Lines- Single Line Panels Very Competitive Business- Allows spare parts
business in the future
Sentry Standard Conditioning Rack Design
Constant flow Efficient sample conditioning Efficient use of space and custom designs Highest Performance Components in the Marketplace 304SS front on conditioning section Dedicated secondary coolers with close
approach temperature
Sampling Systems
Sampling Systems
Sampling Systems
Common Problems Solved with
Sentry Sampling Systems
Problem #1: Non-constant Flow to Analyzers
Sentry VREL and BPR/RV in Tandem VREL Reduces Bulk of Pressure BPR/RV Does Fine Pressure Control Shock Absorber- Extra Flow through
BPR/RV Flat Flow vs. Pressure Curve
Problem #2: Poor Sample Temperature Control
Competitor’s Bath Systems are not “Isothermal” Competitor’s Bath Systems typically only cool Bath has Poor Approach Temperature due to Low
Turbulence Sentry System uses Dedicated Secondary Coolers High Surface Area- Close Approach Temperature +/- 0.25 C control with Chiller; 25+/- 0.5 C through
Sentry Coolers
Problem #3: Plugging Sample Lines
Typically caused by Oversized Sample Lines
Also Caused by Low Flow Sentry Properly Sizes Coolers with Cooler
Program Sentry Recommends Low Pressure
Blowdown
Problem #4: Samples Too Hot
Many Times Competitor’s Coolers are Undersized
Computer Sizing Can Eliminate Sentry has over 30 Cooler Models,
Competitors have 2 to 4 models Sentry models include 0.11, 0.16, 0.22,
0.33, & 0.44 Square Meter Surface Area
Problem #5: Rusting/Patched Panel Front
Most Competitor’s Panels have Painted Carbon Steel Fronts
Sentry Panel has Corrosion Resistant Modular 304 SS Front
Modular Front Allows Future Changes Without Patching the Panel Front
Problem #6: Too Low Sample Flow
Competitor’s Don’t Size Coolers Properly Steam Samples, Especially Low Pressure
Steam, Needs High Capacity Sample Cooler Sentry has Special High Surface Area/Low
Pressure Drop Coolers- FLF-6222/FXF-6223
Problem #7: Thermal Excursions Thermal excursions can cause operator injury,
damage cells, analyzers and other components and discharge of steam to atmosphere
Thermal excursions can be caused by loss of cooling water, high sample flow rate, fouled or plugged sample cooler or high cooling water temperature
Thermal Shut Off Valves - requires no pneumatic or electrical power, re-settable latching design, positive position indication, compact package
Optional switch for remote indication
Problem #8: Multiple Independent Analyzers
Calibration differences can occur between independent analyzers
Calibration requires valuable time Sharing one analyzer reduces calibration
differences, calibration time, consumable usage, capital cost
Sentry Sequencer is a proven method of analyzer sharing
Kinds of Projects
Complete Turnkey Panel Upgrade with Components Some Local Content- Conditioning by
Sentry/Analyzers Supplied Locally
Get Sentry Specified Sentry Panel Specification Specify Sentry Components Require Dedicated Secondary Coolers Require Flanged, single gasket, 304 SS shell,
304 SS Bolts, and 316 SS Tubing Require Sentry VREL on High Pressure Lines
(> 35 Barg) Require Sentry TSV & BPR/RV
Sentry Sampling Systems Set the
World Standard for Quality and
Performance