Sentron Mining Duty Circuit Breaker Family - Siemens · Electronic Trip Long time & Instantaneous...
Transcript of Sentron Mining Duty Circuit Breaker Family - Siemens · Electronic Trip Long time & Instantaneous...
For internal use only / Copyright © Siemens AG 2007. All rights reserved.
Sentron Mining Duty Circuit Breaker Family
Protection notice / Copyright notice
Page 2 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
Siemens Mining Breaker Family
Page 3 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
15-1600A in both 600V and 1000V frames
One trip unit works in either the 600V or 1000V frames
Common footprints for 400/600A and 800/1200A frames simplifies design
Meets every MSHA trailing cable pick up settings using magnetic-only, thermal-magnetic, or electronic breakers
Sentron Mining Family Features
Page 4 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
MSHA pick up settings correspond exactly to a dial position on trailing cable units
Proven reliability in the roughest environments
Easy selection and application
Repairable design
Sentron Mining Family Features
Page 5 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
Increased Interrupting Ratings
Frame EM6 FM6 JM6 LM6 MM6 NM6 PM6Volts 125A 250A 400A 600A 800A 1200A 1600A600 V AC 18kA 18kA 25kA 25kA 25kA 25kA 25kA480 V AC 25kA 35kA 35kA 35kA 50kA 50kA 50kA240 V AC 65kA 65kA 65kA 65kA 65kA 65kA 65kA250 V DC 30kA 30kA 30kA 30kA 30kA 30kA 30kA500 V DC 18kA 18kA 25kA 25kA 25kA 25kA 25kA
Frame EM6 FM6 JM6 LM6 MM6 NM6 PM6Volts 125A 250A 400A 600A 800A 1200A 1600A1000Y/577 V AC 10kA 10kA 14kA 14kA 25kA 25kA 25kA600 V AC 50kA 25kA 50kA 50kA 50kA 50kA 50kA480 V AC 100kA 100kA 100kA 100kA 65kA 65kA 65kA500 V DC 50kA 50kA - - 50kA 50kA 50kA
Standard Mining Duty Interrupting Rating (600 VAC max)
Heavy Duty Mining Duty Interrupting Rating (1000 VAC Max)
Page 6 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
MSHA 30 CFR 75 Pick-up settings correspond exactly with a dial setting on all trailing cable trip units
Electronic Trip Example
All MSHA pick up values within the trip unit range have an exact setting
Electromechanical Trip Example
Trailing cable pick up settings are highlighted on the trip unit
Page 7 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
Easy Application
Standard and trailing cable trip units are identified in the catalog number for easy selection and application
Exact MSHA trailing cable pick up setting positions are marked on the trip units
Trailing cable pick up settings are easily identified by a consistent catalog suffix
Suffix:CA: 50 75 150 200 300 500 600 800 1000CB: 200 300 500 600 800 1000 1250 1500 2000
Suffix:C1: 50 75 150 200C2: 300 500 600 800 1000C3: 1250 1500 2000 2500
Electronic Trip Settings
Electromechanical Trip Settings
Page 8 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
Reduced Inventory: Instantaneous Only
The widest MSHA pick up range available increases versatility and reduces inventory to a fraction of what used to be possible
Trailing Cable Protection Setting per MSHA 30 CFR 75
Siemens Frame
14 1512 2010 308 506 654 853 1002 1151 130
1/O 1502/O 1753/O 2004/O 230250 255300 285350 310400 335500 380
CA, CB indicate that all these trip settings are available on Siemens catalog numbers with that suffix.
AmpereInsulatedConductor
MaximumInstantaneousTrip Setting
Conductor Size Trip Unit
JM
JMKT200X CA
JMKT400X CB
25002500250025002500250020001500125010008006005003002001507550
Cover all trailing cable applications with just 1 frame and 2 trip units
Page 9 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
Reduced Inventory: Long & Instantaneous Protection
Adjustable current ratings coupled with the widest available pick up reduce inventory to a fraction of what used to be possible
MaximumBreaker Continuous Type Amperes* Low 2 3 4 5 6 7 8 9 High 600V Cat # 1000V Cat #
200 50 75 150 200 300 500 600 800 1000 1250 JM6B200XCAW JMKB200XCAW
300 200 300 500 600 800 1000 1250 1500 2000 2500 JM6B300XCAW JMKB300XCAW
400 200 300 500 600 800 1000 1250 1500 2000 2500 JM6B400XCAW JMKB400XCAW
LM-E 600 200 300 500 600 800 1000 1250 1500 2000 2500 LM6B600XCAW LMKB600XCAW
Instantaneous OnlyElectronic Trip Long time & Instantaneous Breakers
JM-E
Complete BreakerNominal AC Adjustable Trip Setting
Page 10 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
Siemens can Meet Exact MSHA Pick Up Settings in Magnetic Only or Thermal Magnetic Frames
Low 2 3 4 5 6 7 High 600V Cat # 1000V Cat #EM 050 50 75 100 150 200 - - - EM6B050MC1 EMKB050MC1
125 300 500 600 800 1000 - - - EM6B125MC2 EMKB125MC2FM 250 300 375 450 500 550 600 900 800 FM6B250MC2W FMKB250MC2W
250 1000 1250 1350 1500 1800 2000 2250 2500 FM6B250MC3W FMKB250MC3WJM 225 350 400 500 600 700 800 900 1000 JM6B225MC2W JMKB225MC2W
400 1100 1250 1500 1650 1800 2000 2250 2500 JM6B400MC3W JMKB400MC3WLM 400 300 400 500 600 700 800 900 1000 LM6B400MC2W LMKB400MC2W
600 1100 1250 1500 1650 1800 2000 2250 2500 LM6B600MC3W LMKB600MC3WMM 800 1250 1500 1650 1800 1900 2000 2250 2500 MM6B800MC3W MMKB800MC3WNM 1200 1250 1500 1650 1800 1900 2000 2250 2500 NM6B1200MC3W NMKB1200MC3W
MaximumContinuous
AmperesBreakerFrame
Nominal AC Adjustable Trip SettingMagnetic Trip OnlyCircuit Breaker
Siemens magnetic only and thermal magnetic breakers offer the widest trip ranges The C_ suffix designation applies to all Siemens Mining Breaker C1 – Setting position for all MSHA pick up values from 50 to 200 C2 – Setting position for all MSHA pick up values from 300 to 500 C3 – Setting position for all MSHA pick up values from 1250 to 2500
Page 11 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
Proven Reliability in the Roughest Environments
Lab tested and confirmed interrupting capabilities
Lab tested and confirmed mechanical endurance
Lab tested and confirmed calibrations
Benchmarked in simulated applications for market leading endurance
Extensive on site testing in the mines of West Virginia
Based on Siemens classic family construction
Page 12 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
Proven Reliability in the Roughest Environments
Interchangeable trip units
Full line of filed installable external accessories
Full line of field installable internal accessories (UVR, shunt trip, aux switch, bell alarm, PLC aux)
Special UVRs have been designed specifically for mining duty application
Page 13 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
Application Flexibility: Rear Connecting Accessories
Rear Plug InsRear Connectors
Compression Lugs
Page 14 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
Application Flexibility: Operator Accessories
Variable Depth Max flex Motor Operator
Page 15 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
Flexible Design with Easy Modifications
Interchangeable trip units in the 250 to 1600A Frames
400A frame trip units work in 600A frame breakers
800A frame trip units work in 1200A frame breakers
One trip unit for both 600V & 1000V frames
Page 16 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
Flexible Design with Easy Modifications
Field Installable Accessories in ALL FramesAll seven frames are covered with four sets of accessories
AccessoryMounted
Accessory
Accessory Accessory Mounted
Page 17 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
Designed Completely From Customer Input
Better Reliability An extensively tested rugged design
Reduced Inventory Increased coverage of trailing cable applications in a fraction of the breakers
Increased Ratings Equal or improved interrupting ratings
Easy ApplicationExact MSHA pick up setting are highlighted on the trailing cable trip units, with their ranges identified by a simple catalog number
suffixReduced Design Effort Common 400/600A and 800/1200A frames & trip units
Repairable ProductsSiemens Westinghouse Technical Services authorized Mine
Duty repair center
We DeliveredYou Asked For
Page 18 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
Mining Breaker Replacements
FBM HFBM
FDBM FDM HFDM (Mag. Only)
E2F EM6 HFM E2FM EMK
JDM E2J FM6 JDCM E2JM FMKKAM KAMH
KDM E2K JM6 HKAM KDCM E2KM JMK
LAM LAMH LCM LCMH
LDM E2L LM6 HLAMHLCM
LDCM E2LM LMK
MAM MAMH MCM MCMH
MM6 HMAM HMCM
MMK
NBM NBMH NCM NCMH
E2N NM6 HNBM HNCM HNBMH HLCLM
E2NM NMK
E2R PM6 HPBM E2RM PMK
600VClassic E2
Sentron Heavy Mine DutySeries C E2
SENTRON StandardMine Duty Series C
1000VClassic
Page 19 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
The Mining Breaker Selection Guide offers complete application and pricing information
MCCB CAD drawings are available from your Siemens Representative
Further Information
Page 20 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
Industrial Products
s s s s s s s s s s s s s s s s s s
s s s s s s s s s s s s s s s s s
s s s s s s s s s s s
s s s s s s s s s s s
s s s s s s s s s
s s s s s s s s
s s s s s
Single Source Supplier
Represents major market presences
Large Motor Small Motor
DC Drives AC Drives
PCSPLC
Swboard / PnlboardBusway
LV Switchgear MV Switchgear
ControlsMCC
Voltage Regulator Power Breaker
Residential Enc. Switch
XformerMCCB
Construction Products UtilityProducts
Competitors
Siemens
General Electric
Eaton /Cutler-Hammer
Schneider /Square D
ABB
Allen-Bradley / Reliance
Toshiba
Page 21 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
Contact
Fred MyersProduct Manger - MCCB
5400 Triangle ParkwayAtlanta, GA 30092
Phone: (770) 326-2056Fax: (770) 326-2051
E-mail: [email protected]
Page 22 February 19, 2009Protection notice / Copyright noticeCircuit Protection & Controls Marketing
Siemens Sentron Mining BreakersThank you for your time!
For internal use only / Copyright © Siemens AG 2007. All rights reserved.