Sensors and switchesTemperature, Pressure, Humidity, Air flow and CO2
S E N S O R S A N D S W I T C H E S
S E N S O R S A N D S W I T C H E S
Regin sensors and switches – Comfortable and economic indoor climate
To measure is to know.Temperature, carbon dioxide, air circulation and humidity in buildings are constantly affected by conditions outside and inside the building. To maintain a pleasant indoor climate and safeguard energy-efficient operations the control systems need constant information.
Regin offers a comprehensive programme of sensors and switches for every need. Our products are well known for high quality, accuracy and long term stability.
You can really trust in them.
The temperature transmitters and sen-sors with housing in the Tempero series are designed according to “Ready-Steady-Go” with the aim of simplifying installation, and commissioning.
The Regin room transmitter is available as a combined CO2, temperature
and humidity transmitter.
The Regin differential pressure transmitter for air has four selectable measuring ranges.
in the same unit. The LCD display gives a good overview of measured values
S E N S O R S A N D S W I T C H E S
The Regin range includes NTC, PT100 and PT1000 temperature sensors and transmitters. For room, pipe, duct, im-mersion and floor mounting etc.
High concentrations of CO2 cause headaches, dizziness and fatigue. The maximum limit of 1 000 ppm should therefore not be exceeded. Regin’s CO2 transmitters give a direct indication of the indoor air quality, which makes it possible to increase the supply air as long as necessary.
A clogged filter impairs quality of the supply air and is bad economy. Regin’s differential pressure transmitters control the condition of filters and give an alarm when service is needed.
The relative humidity (RH) in buildings is recommended to be between 25-80% in the winter and 20-70% in the sum-mer. At any season of the year, you can rely on Regin’s humidity transmitters and humidistats.
S E N S O R S A N D S W I T C H E S
Output: 0…10 V DC or 4…20 mA
Working range Humidity 0...90% RH
Working range Temp. 0...50°C
Accuracy Humidity +/-2% RH (40...60% RH) otherwise +/- 3% RH
Accuracy Temp. +/-0.25 K and +/-0.4 K depending on type
Protection class IP30
The HRTN series – Room humidity/temperature transmitters, wall mounting with or without display
Output One (1) or two (2), 10 A, 250 V AC, change-over
Setpoint 10...100% RH
Hysteresis 3% RH
Step differential (HMH2) 0...25% RH
Mounting Duct or wall-mounting
Protection class IP54
The HMH series – Duct/Wall humidistats, mechanical
Output One (1), 230 V AC, 5 A, change-over
Setpoint 35...95% RH
Hysteresis 7% RH
Mounting Wall-mounting
Protection class IP30
The HR-S series – Room humidistats, mechanical
Output: 0…10 V DC or 4…20 mA
Working range HRT 350 series
Humidity: 20...95% RH
Temperature: 0...+50°C
Working range HRT 250 series
Humidity: 0...100% RH,
Temperature: -20...+80°C
Accuracy/humidity
HRT 350 series +/-3% RH (40...60% RH) otherwise +/-5% RH
HRT 250 series +/-2% RH (40...60% RH)
Accuracy/temperature
HRT 350 series +/-0.5 K at 20°C
HRT 250 series +/-0.2 K at 20°C
Protection class IP65
The HRT series – Wall humidity/temperature transmitters, wall mounting
Output: 0…10 V DC or 4…20 mA
Working range HDT 2200 series
Humidity: 0...100% RH
Temperature: -20...+80°C
Working range HDT 3200 series
Humidity: 20...95% RH,
Temperature: 0...+50°C
Accuracy/humidity
HDT 2200 series +/-2% RH (+/-2% RH 90...100% RH)
HDT 3200 series +/-3% RH (+/-5% RH 40...60% RH)
Accuracy/temperature
HDT 2200 series +/-0.4 K at 20°C
HDT 3200 series +/-0.7 K at 20°C
Protection class IP65
The HDT series – Duct humidity/temperature transmitters
HumidityHumidity transmittersRegin humidity transmitters have a capacitive thin-film element that gives a signal that is proportional to the relative humidity (RH). The measuring element rapidly responds to changes in humidity and can be subjected to up to 100% RH without being damaged.
High accuracy and rapid response •
Good long-term stability•
Resistant to contamination•
Supply voltage: 24 V AC or 15...35 V DC. •Automatic adaption to the connected voltages. •Room, wall or duct mounted•Available as single humidity transmitters or as combined •humidity and temperature transmitter.
HumidistatsRegin humidistat are used for controlling humidifying and/or dehumidifying in HVAC systems. The humidi-stats have human hair or a synthetic element as sensor medium. The hair stretches as the humidity increases and shrinks as the humidity decreases. The changes are transmitted to a micro switch.
Reliable construction with a high degree of accuracy •(introduced the first time by Regin in 1947)
Contacts of the changeover type: 2 step humidistat•
Output One (1) or two (2), 10 A, 250 V AC, change-over
Input 0...10 V DC
Humidity rangeability 20...95% RH
Hysteresis 1...20% RH
Step diff. (HD2) 0...20% RH
Mounting DIN-rail, 3 modules
Protection class IP20
The HDI series – Electronic humidistats
S E N S O R S A N D S W I T C H E S
Output: Selectable: 0…10 V DC or 4…20 mA,
Working range 4 selectable ranges 0…1000 Pa
Accuracy Better than ±1% at 20°C
Electronic damping 0...20 s
Protection class IP54
The DMD series – Differential pressure transmitters for air with LED display
Output: 0…10 V DC or 4…20 mA
Working range Selectable -50...5000 Pa
Accuracy +/-1% fs
Ambient temperature 0...70°C
Protection class IP54
The DTL series – Differential pressure transmitters for air and non-corrosive gases
Output: 0…10 V DC or 4…20 mA
Working range: 0…2500 kPa
Accuracy: +/-1,38% fs for transmitter 0…10 kPa and 0…250 kPa
+/-0,8% fs for transmitters 0…400 kPa
+/-0,5% fs for transmitters 0…600 and 0..2500kPa
Ambient temperature -15...+80°C
Protection class IP65
The DTK series – Differential pressure transmitters for liquids and gases
Output: 0-10 V DC or 4-20 mA
Working range: 0…10 MPa (100 bar)
Accuracy +/-0.3%
Media temperature range -15...+80°C
Protection class IP 65
The TTK series – Pressure transmitters for liquids and gases
Output: 0-10 V DC or 4-20 mA
Working range:
Selectable 0...10 m/s, 0...15 m/s, 0...20 m/s
Accuracy +/-(0.3 m/s +3% of value), at 0...10 m/s+/-(0.3 m/s +3% of value), at 0...15 m/s+/-(0.3 m/s +4% of value), at 0...20 m/s
Damping 0.2 or 2 s (optional)
Ambient temperature
-10...+50°C
Protection class
IP65
The AVDT25 series – Air velocity sensors
Output 5 A (0.8 A) 250 V AC
Working range: Selectable pressure range from 20…5000 Pa
Max. overload pressure 5000 Pa
Ambient temperature -20...+85°C
Protection class IP54
The DTV series – Differential pressure switches, for air and non-corrosive gases
Flow switch
Output 6(2) A, 250 V AC, change-over contact (SPDT)
Max. fluid pressure 10 bar tested to 15 bar
Max. fluid temperature 110°C
Storage temperature -20...+80°C
Protection class IP64
Pressure and Air flowDifferential pressure switchThe differential pressure switch has a synthetic spring suspended membrane which is linked to a changeover contact. When the differential pressure exceeds the setpoint value the contact switches. The differential pressure switch is used to supervise and monitor fans, filters and air handling units, to control defrosting func-tions etc.
Pressure transmittersRegin pressure and differential pressure transmitters use a ceramic measuring beam. The differential pressure affects a membrane that works directly against the measuring beam with a film resistor. When the resistance changes it is converted to a proportional output control signal.
High degree of accuracy•
Few moving parts – rapid response•
Excellent long-term stability.•
Duct sensor for air velocityThe air velocity sensor operates with a specially designed thin-film element which is heat sensitive (the hot-film anemometer principle). The cooling rate of the element, which depends on the air velocity, is measured and trans-formed to an output signal proportional to the air speed.
Stable output signal compensated •for varying temperature
Extremely high frequency response•
Not sensitive to contamination by dust etc. •
Flow switchesThe flow switch operated by an electrical blade-type tripping device interrupts the electric control circuit when there is insufficient water circulation owing to abnormal conditions.
S E N S O R S A N D S W I T C H E S
TRTN - Room mounting
Output 0...10 V DC or 4...20 mA
Temp range 0…50°C
Accuracy +/-0.3°C
Protection class IP30
TRT - Wall-mounting
Output 0...10 V DC or 4...20 mA
Temp range 0…50°C
Accuracy +/-0.7°C
Protection class IP65
TLT 130 - Immersion mounting
Output 0...10 V DC or 4...20 mA
Temp range 0…100°C
Accuracy +/-0.5°C
Protection class IP65
TDT200 - Duct mounting
Output 0...10 V DC or 4...20 mA
Temp range 0…50°C
Accuracy +/-0.5°C
Protection class IP65
Temperature transmittersWithout housing
TG-A… Clamp-on sensor 0…30°C
TG-B… Bulb sensor -20 …+10°C up to 60…90°C
TG-G… Floor sensor 0…40°C
TG-D… Immersion sensor 0…30°C up to 60…90°C
TG-K3… Duct sensor -30…+30 up to 0…70°C
With housing
TG-R4…Room sensor with setpoint adjust-ment
0...30°C
TG-R5… Room sensor 0...30°C up to 20...50°C
TG-R6… Outdoor sensor -30...+30°C up to 20...50°C
NTC sensors
TG-AH1/PT1000Clamp-on sensor w housing
-30...+120°C
TG-A1/PT100/1000Clamp-on sensor w/o housing
30...+150°C
TG-B1/PT100/1000 Bulb sensor -30…+100°C
TG-KH/PT100/1000 Duct sensor with housing -30…+70°C
TG-K3/PT100/1000 Duct sensor w/o housing -30…+70°C
TG-MH/PT1000
Average temperature sensor with housing
0…70°C
TG-DH/PT100/1000 Immersion with housing -20…+120°C
TG-DHW/PT100/1000Immersion with housing + well
-20…+120°C
TG-D1/PT100/1000 Immersion w/o housing -30…+150°C
TG-R4/PT1000 TG-R5/PT100/1000
Room sensor setpoint adj 0…50°C
TG-UH/PT100/1000 Outdoor sensor -30…+120°C
PT100/PT1000 sensors
Temperature sensors and transmittersWhenever you need to keep track of the temperature in- and outside a building Regin has all you need. The product range includes NTC, PT100 and PT1000 sen-sors and transmitters. They are well-known for high accuracy and long-term stability.
NTC sensors Measures the temperature resistance in a ceramic •element (NTC). When the temperature rises the resistance is reduced.
PT100/PT1000 sensors Based on platinum elements with standardized resistance. •PT100: 100 ohms at 0°C. PT1000: 1000 ohms at 0°C. Available in a wide range of mounting versions•
Temperature transmittersFor room mounting and immersion mounting•Output signal 0...10 V DC or 4...20 mA.•
The screw cap offers quick and easy installation.
The PT100 and PT1000 sensors in the Tempero series are designed according to “Ready-Steady-Go”.
Duct sensor with soft seal for perfect surface contact. The sensor length in the duct is easily adjustable.
S E N S O R S A N D S W I T C H E S
Outputs
CO2 0...10 V DC referring to 0...2000 ppm
Temperature 0...10 V DC referring to 0...50°C, PT1000-sensor (class DIN B)
Humidity 0...10 V DC referring to 10...90% RH (working range 1...9 V)
Working range
CO2 0...2000 ppm
Temperature 0...50°C
Humidity 0...90% RH
Accuracy
CO2 ± (50 ppm +2% of working range)
Temperature ±3°C
Humidity 3% (30...70% RA) ± 5% (10...90% RH)
Protection class IP30
Output 0…10V DC
Working range CO2 0...2000 ppm
Accuracy CO2 ± (50 ppm +2% of measured value)
Protection class IP65
The CO2RT series – Wall mounted room transmitter The CO2DT series – Duct transmitter
CO2The Regin CO2-transmitters give direct information about the concentration of CO2 in the room or building. Based on these values the ventilation system is con-stantly controlled to provide an optimum concentration of CO2 in the air.
Very high accuracy due to patented auto-calibration function •with infrared light measuring and reference measuring system Low risk for contamination•
Short response time•
High long-term stability•
Long calibration interval - more than 5 years •and no calibration necessary at installation.
Standard version:CO• 2 temperature transmitter for room or duct mounting.
Optional: CO• 2 and temperature transmitter
CO• 2 and temperature transmitter with display
CO• 2, temperature and humidity transmitter with display
CO• 2 transmitter with relay
The transmitter is available in versions with LCD display which gives you a good overview of all measured values.
BR–T
RAN
SMIT
TERS
–EN
200
9-12
w
ende
lbo.
com
R E G I N – T H E C H A L L E N G E R I N B U I L D I N G A U T O M A T I O N
Box 116, S-428 22 Kållered,
Sweden
Phone: +46 31 720 02 00
Fax: +46 31 720 02 50
www.regin.se
AB Regin Head office
FranceRegin Controls SARL
32 rue Delizy
F-93500 Pantin
Phone: +33 1 41 71 00 34
www.regin.fr
GermanyRICCIUS + SOHN GmbH
Haynauer Str. 49
D-12249 Berlin
Phone: +49 30 77 99 40
www.riccius-sohn.eu
SpainRegin Ibérica, S.A.
C/Arganda 18 local
E-28005 Madrid
Phone: +34 91 473 27 65
www.reginiberica.com
SingaporeRegin Controls Asia Pacific Pte Ltd
66 Tannery Lane
# 03-04 Sindo Building
Singapore 347805
Phone: +65 6747 8233
www.regin.com.sg
Hong KongRegin Controls Hong Kong Ltd
Room 2901
EW International Tower
120 Texaco Road
Tsuen Wan, NT
Hong Kong
Phone: +852 2407 0281
www.regin.com.hk