Sensing and Processing of Bio-metric Signals for use in Low Cost Bio-robotic Systems
![Page 2: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/2.jpg)
What is Bio-Metrics? Biometry − Bio (Greek word for Life)+ Metrics (Measurements) Biometrics is the science of measuring and analyzing biological
data. Biometrics refers to technologies that measure and analyze
human body characteristics such as DNA, fingerprints, eye retinas and irises, voice patterns, facial patterns and hand measurements.
![Page 3: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/3.jpg)
How Bio-Metrics work?
![Page 4: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/4.jpg)
• Input Interface (Sensors)- It is the sensing component of a biometrics system that converts human biological data into digital form.
• Processing Unit- microprocessor, Digital Signal Processor (DSP), or computer that processes the data captured from the sensors.
• Database Store- The database stores the enrolled sample.
• Output Interface- The output interface communicates the decision of the biometric system to perform a task.
![Page 5: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/5.jpg)
![Page 6: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/6.jpg)
Need for Bio-Robotic Systems?
• To replace Humans in Hazardous Working Conditions.
• Recovery of Human Organ Functions.• To perform high Precision tasks ,such as
Surgeries.• As Exoskeletons for paralyzed people.
![Page 7: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/7.jpg)
![Page 8: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/8.jpg)
![Page 9: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/9.jpg)
Prosthetics
• Prosthetics are artificial devices that replace injured or diseased body parts
• There are two types of Prosthetics- 1. Passive Prosthetics 2. Active Prosthetics
![Page 10: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/10.jpg)
Requirements of a good Prosthetic
• Should match the real Limb as close as possible
• Same Size as the Limb• Low Weight• Economical• Long Lasting
![Page 11: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/11.jpg)
Existing Prosthetics
1. Passive Prosthetics: They do not have sensors or any control mechanisms. They are cheap.
2. Active Prosthetics: They use sensors and Control mechanisms to mimic the actions of the real limb. They are far more expensive than Passive Prosthetics.
![Page 12: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/12.jpg)
Sensing Technologies1. Electromyography(EMG): Electromyography (EMG) is a technique for evaluating and
recording the electrical activity produced by skeletal muscles. An EMG signal is the electrical activity of a muscle’s motor units Most commonly used control method for Bio robotic systems
(Prosthetics) EMG frequency spectrum falls in the 0-500Hz range
![Page 13: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/13.jpg)
![Page 14: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/14.jpg)
2. Electroencephalography(EEG): An electroencephalogram (EEG) is a technique used to track
and record electrical activity of the brain. EEG measures voltage fluctuations resulting from ionic current
within the neurons of the brain.
![Page 15: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/15.jpg)
![Page 16: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/16.jpg)
Invasive Vs Non-Invasive1. Invasive – Requires Surgery or Implantation Risk of Infection or Electrode rejection High resolution of the obtained Signals More Expensive Used in special cases
2. Non-Invasive- Doesn’t require Surgery or Implantation Low resolution of the obtained Signals Less Expensive Commonly used
![Page 17: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/17.jpg)
Choice of Sensing Technology
Advantages of EMG:• Low cost• Simplicity: Most times, surface electrodes are
sufficient to collect adequate data.• Prediction: In most muscles, the EMG activity
precedes the motion of the actuated limb.
![Page 18: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/18.jpg)
Circuit Design
• Sensing Circuit Comprises of 3 stages1. Input Amplification2. Filtering3. MAV(Mean Average Voltage) Circuit
![Page 19: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/19.jpg)
![Page 20: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/20.jpg)
Input stage
• Consists of Sensory Circuits• Sensory Circuits comprises of a set of Silver
Chloride Electrodes attached to person’s skin• One electrode is placed at core of the target
muscle• Other electrode is placed at a remote location• An instrumentation amplifier is used to
amplify signal by x1000
![Page 21: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/21.jpg)
![Page 22: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/22.jpg)
Filtering Stage
• Filtering stage consists of High Pass and a Low Pass Filter
• More Dominant frequencies are identified after Fourier analysis and rest are filtered out
• Frequencies 20Hz to 400 Hz are allowed to pass
![Page 23: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/23.jpg)
![Page 24: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/24.jpg)
![Page 25: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/25.jpg)
MAV Circuit
• MAV (Mean Average value) circuit consists of1. Peak Detector2. Clipping Circuit3. Integrator• Peak detector converts signal to a series of
Peak spikes• Then Peak values are cut off at a safe Voltage
level
![Page 26: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/26.jpg)
• Integrator provides a slow signal that rise and fall with the amount of muscles activity.
![Page 27: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/27.jpg)
Conclusion
• Prosthetics based on EMG offers an effective low cost solution for amputees.
• Prosthetics based on EMG have the following disadvantages:1. Injuries are not same for every amputee, so
Prosthetics have to be customized.2. EMG signal strength depends on many factors,
such as Muscle size ,Skin type etc, some of which may vary with time.
![Page 28: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/28.jpg)
![Page 29: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/29.jpg)
![Page 30: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/30.jpg)
![Page 31: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/31.jpg)
![Page 32: Sensing and processing of Bio metric signals for Low cost Bio Robotic systems](https://reader031.fdocuments.us/reader031/viewer/2022030215/588a52861a28abd3088b71a5/html5/thumbnails/32.jpg)