Seminar k nail
-
Upload
deepak-chauhan -
Category
Health & Medicine
-
view
623 -
download
1
Transcript of Seminar k nail
![Page 1: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/1.jpg)
K NAIL- HISTORY, DESIGN AND BASIC PRINCIPLES
DEEPAK CHAUHAN (J.R.orthopaedics)
MODERATOR-Prof.VIJAY G.GONI
![Page 2: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/2.jpg)
History of Intramedullary nailingThe beginnings -16th century In Mexico aztec physicians have Placed wooden sticks in to the
medullary canal of patients with long bone non-unions.
Mid 1800s Ivory pegs were inserted in to
the medullary canal.In 1917s-hoglund of the united states
reported use of autogenous bone as intramedullary implant
![Page 3: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/3.jpg)
![Page 4: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/4.jpg)
Evolution of KÜNTSCHER NAILING
Gerhard Küntscher was born in1900 in Germany. Development occurred during World War-2(1939-42) while Germany was at war, Küntscher was deployed as Chief medical officer in german army. The german military had the upper hand in treating soldiers with the IM nail and having return to fighting status in few weeks. Worldwide knowledge was not established Until prisoners of war returned to their home Countries carrying Kuntscher legacy in form of Of Steel nail in their legs.
![Page 5: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/5.jpg)
The technique of femoral neck nailing described by smith –peterson has been expanded by Küntscher for the nailing of long shaft bones.
His original intramedullary nail was a V-shaped stainless steel that was inserted antegrade.
Küntscher first reported use of V-shaped nail in 1940.
Early in the development of his technique,he recommended inserting the nail through a portal remote from fracture site-differs from all operative fracture methods used in the past.
By late 1940- küntscher abandon use of the V-shaped nail design in favour of another design-the cloverleaf nail.
![Page 6: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/6.jpg)
Küntscher first nail in a human was inserted in 1939 & reported at university of Keil medical society on dec 1939.
His method was essentially unknown in U.S. during war and was first Described in US march,1945,Time magazine article,entitled“Amazing Thighbone”.
Küntscher published his his first book in 1945 on intramedullary nailing.
.
![Page 7: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/7.jpg)
Principle of KÜNTSCHER nailing (GERHARD B. G. KÜNTSCHER J Bone Joint Surg Am. 1958;40:17-26.)
The basic principle -stable osteosynthesis through - flexible impingement of nail in the bone
- adequate friction of the nail in both fracture fragments .
The device firmly impinged in the bone by elastic forces in such a way that a carpenter’s nail becomes impinged in wood.
However the analogy does not follow in every detail.As in cross section a carpenter’s nail is almost
rigid,when driven in to wood,it pushes wood aside.by contrast medullary cavity is quite rigid; therefore to achieve elastic impingement,the cross section of nail must be design to have elasticity with a V profile or even better clover-leaf design.
![Page 8: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/8.jpg)
Drawings showing cross sections of two types of intramedullary nails.the V nail is compressible in only one direction,whereas the
clover-leaf nail is compressible in two directions,these directions being right angles to each other.
V - nail Cloverleaf nail
![Page 9: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/9.jpg)
A SIMPLE EXPERIMENT DEMONSTRATES THE ELASTIC COMPRESSIBILITY OF THE CLOVER –LEAF NAIL.If a clover –leaf nail 12mm in width is mounted in to a vise,it can be compressed about 3 mm but will immediately recover its original shape,when released from the vise.
![Page 10: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/10.jpg)
Use of this principle of elasticity will achieve the idea of complete and permanent immobilization of the fragments and offers an absolute guarantee of bone union.There are two reasons for this:
1.Lateral movement can be eliminated only if the nail occupies the entire width of canal througout its length.this can’t be accomplished with a solid rod which can not be compressed for varying canal width.
![Page 11: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/11.jpg)
A solid nail (left) will not occupy the full width of the medullary canal in most places since its
diameter must be selected to fit the narrowest portion of the canal. A nail with an elastic cross section (right ) will adjust to
the constrictions of the medullary canal.
Solid nail Elastic nail
![Page 12: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/12.jpg)
2.The second reason also of great importance.
.Bone resorption will soon loosen a solid rod(left),even though at first this rod accurately fit inside canal.
. However nail with a compressible cross section (right)will expand during bone resorption
. This nail is designed to render the mechanical effects of bone resorption ineffective.
Solid nail elastic nail
![Page 13: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/13.jpg)
DESIGN-femoral ‘K’ nail (THE TECHNIQUE OF INTRAMEDULLARY NAILING GERHARD KÜNTSCHER, MD and RICHARD MAATZ, MD Professor ReaderSurgeons, Department of Surgery, Kiel University Hospital
Cross section-roughly V or cloverleaf shaped
Sheet metal thickness reduced on back-provides compressibility
Hollow core-admits guide wireSlot-anterolaterally tension sideEye- at both endsCommon sizes-lengths-
30,34,36,38,40,42cm diameter-8,9 and 10 mm
Protude at least 3cm from trochanter Standard femur K nail-
![Page 14: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/14.jpg)
Special designsTapered end- subtrochanteric
fractureY nail- peritrochanteric fracture
Some cases Saw teeth at its tip- for bone containing central callus.eg-refracture,delayed union
![Page 15: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/15.jpg)
TIBIAL NAILSDouble nailsCurved in shapeCross section-U shapedLengths-24-39 cm,at 1.5 cm
increments largest diameter-8 and 9 mmTwo designs of spreading nail- Deflect to spread nail Rotate to spread nail
![Page 16: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/16.jpg)
Deflect to spread nailTwo nails spreads distally by means of an
inclined plane on outer nail
The inclined plane on outer nail & rear wall of bone tube provides deflecting surfaces - make inner nail veer in posterior direction
Outer nail should be inserted first.Resistant to bendingUsed in fractures distal to isthmus-long
oblique fractures or segmental bone loss(anterior edge).
![Page 17: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/17.jpg)
Rotate to spread nailAlso consists two nailsOuter nail-standard patternInner nail-circular cross section
and a lazy S shape
Inner nail should be inserted firstOnly for transverse or short
oblique fractures,bone loss(posterior cortex)
A=outer nailB=inner nail
![Page 18: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/18.jpg)
Instruments Nail guide-solid,circular cross
section Length-64 cm,diameter-3mm Awl- with an offset four sided tip
Impactor-facilitates insertion of nail,allows hammer blows directed along main axis of middle portion of nail.
nail guide
Awl
Tibial nail impactor
![Page 19: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/19.jpg)
Slotted hammer-most suitable instrument for extraction even very firm seated nail
Kuntscher extractor-threaded rod& Spring system combines traction
and hammer blows. pretension needs to reset with every blow
Slotted hammer with extraction hook
c b
aa=threaded rod with fitting for hammerb=spacer=prevent bone damage at instrument placement siteC=extension
![Page 20: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/20.jpg)
Reamers-
Nail bender- allows nail contouring(other than femoral nails)
![Page 21: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/21.jpg)
Stepped scale- for radiographic determination of medullary cavity diameter
Reduction apparatus-
![Page 22: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/22.jpg)
Positioning
![Page 23: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/23.jpg)
Küntscher policies:1.if a fracture is “nailable” it should be
nailed.2.nailing will be done in patients that are
at particular risk if kept at bed rest in cast or on traction.
3.nailing will be performed to manage fractures that are notoriously difficult,such as smooth transverse fracture.
4.one particular indication in spontaneous fracture of metastatic bones.
![Page 24: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/24.jpg)
Uses
Fractures- femur ,tibia,humerus,forearm,clavicle.
Compound fractures,gun-shot fractures.
For non union,delay union.Correction of malunion.Congenital or aquired deformitiesarthrodesis
![Page 25: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/25.jpg)
Criteria of nailing- fractures?Criteria of nailing will depend on shape of the boneSite of the fracturePattern of fractureThere are no definite cut –offs between suitability
grades- this is why fractures are best classified as “very suitable”-absolute indications
“suitable” “borderline” extended indications “unsuitable”
![Page 26: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/26.jpg)
Intramedullary nailing is ruled out in all intra-articular fractures :
nail may force fragments apart that are still in reasonable contact.
the device will not be able to obtain an adequate purchase.
the joint may be at risk from nail intrusion.
![Page 27: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/27.jpg)
Femur fractures-nailing criteriaVery suitable-transverse fractures
and oblique fractures with a short-fragment medullary cavity providing at least 8 cm of “nail-suitable” medullary cavity.
Secure against angulation,lateral displacement and shortening.
Risk of rotation-little in oblique fracture,more with transverse fracture
Immediate weight bearing allowed
![Page 28: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/28.jpg)
“Suitable” fractures- spiral fractures
well secure against angulation and lateral displacement.
Shortening will occur with rotational malalignment-as smooth fragments will slip past each other when loaded.
No weight-bearing before the end of 3rd week.
![Page 29: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/29.jpg)
Unsuitable fractures- supracondylar fracture with
separation of condyles(Y or T fracture)-
Peritrochanteric fractures-head end of standard nail would not obtain sufficient purchase in trochanter..but they are very suitable with Y nail.
![Page 30: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/30.jpg)
Butterfly and segmental fractures
very suitable-large fragments with a bone defect on one side OR non-communited third fragment in segmental fracture.
.Lateral dispalcement ruled out.secured against angulation..shortening is not possible-one side continuous cortex..immediate weight bearing
![Page 31: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/31.jpg)
Communited fractures- “suitable”
secure against displacement and angulation.
Great risk of shortening and malrotation.
Supplementary support –skeletal traction may require
Weight bearing once sufficient callus formed.
![Page 32: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/32.jpg)
Tibia fracturesCompared to femur –conditions
are more adverse.Nail has to be curved-since
introduced from lateral entry point.
Very frequently producing displacement of fracture in to recurvation.
Unlike femur,most of the thing depends on shape of medullary cavity..
![Page 33: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/33.jpg)
Nailing criteria :tibia fractures criteria of nailing in tibia dependson diameter of the nail (n) diameter of medullary cavity
at fracture site (m) thickness of cortex (k)If m-n<_k the fracture is
“suitable”(depending on fracture pattern).
If m-n>k the fracture is“unsuitable”
![Page 34: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/34.jpg)
Proximal -third transverse fractures-The difference
between medullary cavity diameter and the nail diameter is equal to or greater than thickness of the cortex.In all these cases all fracture patterns are “unsuitable” with the standard nail.
Fragments are secured against rotational only,but may displace in all other directions
![Page 35: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/35.jpg)
. m-n<k (borderline)
. lateral dislacement. protected against all other displacements by great friction b/w bone & nail at x.
.No supplementary support require..moblization at end of 3 week
Proximal third oblique fractures (border line)
![Page 36: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/36.jpg)
.conditions are same like oblique fractures but there is strong torque forces which can not be neutralize by nail..Supplementary long leg cast requiredProximal third (spiral
fractures)-”borderline”
![Page 37: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/37.jpg)
“Unsuitable”(m-n>k)since the nail can not prevent major anguation
Proximal third Butterfly and Communited fractures
![Page 38: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/38.jpg)
Middle -third tibia fracturesHere the diameter of the medullary
cavity will be the same as that of nail-all fractures in this part suitable for nailing.
Nail will fit snugly & provide adequate friction
Transverse fracture & oblique fracture- “very suitable” .
Spiral fractures- “suitable”as risk of rotation
![Page 39: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/39.jpg)
Middle third butterfly fractures-“Borderline”-for standard nail Very suitable- for spreading nail . An anterior
butterfly fragment should be managed with deflect to spread nail.
.A posterior fragment –managed with rotate to spread nail.
![Page 40: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/40.jpg)
Distal third tibia fracturesSpreading nail are useful-splayed
pattern at distal end of this double nail provide greater overall diameter.
Oblique or transverse fractures: m-n<k “unsuitable for standard double nail very suitable -spreading nail.
![Page 41: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/41.jpg)
Nail removal.Earlier removal may be indicated in
following: 1.displaced fragments and nail is
making impossible to obtain reduction. 2.migrating nail-threatening joints or
soft tissue at its end 3.bent or broken nail 4.in children after achieving sound
union.
![Page 42: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/42.jpg)
![Page 43: Seminar k nail](https://reader035.fdocuments.us/reader035/viewer/2022081513/5878297a1a28abef5d8b5131/html5/thumbnails/43.jpg)
THANK YOU