Semen_POC
description
Transcript of Semen_POC
ContentsA. Storage Testing Environment:.............................................................................................................3
A.1 V7000 internal disks Pool --> RAID-5 40 disks SAS + 8 disk SSD (easy tier) in 1 pool.........................3
A.2 DS5000 virtualized by V7000 --> RAID-5 40 FC disks in 5 volume virtualized into 1 pool..................3
A.3 Flashsystem 720 virtualized by V7000 RAID-5 virtualized into 1 pool..........................................3
A.4 Flashsystem 720 direct connect to host RAID-5............................................................................3
B. Server Testing Environment:...............................................................................................................3
C. Zoning..................................................................................................................................................6
SANSWITCH SAN_30................................................................................................................................6
SANSWITCH SAN_40................................................................................................................................6
D. Performance Testing............................................................................................................................7
D.1 internal disk on V7000.......................................................................................................................8
DS5300 virtualized with V7000 in 1pool................................................................................................11
Flashsystem virtualized with V7000 in 1 pool (cache enabled).............................................................14
Flashsystem virtualized with V7000 in 1 pool (cache disable)...............................................................17
Flashsystem direct connect to hosts......................................................................................................20
Additional Test..........................................................................................................................................23
Flashsystem direct connection using 4 volumes....................................................................................23
Flashsystem on sequential access.........................................................................................................26
Summary Performance Testing Result.......................................................................................................27
A. Storage Testing Environment:
A.1 V7000 internal disks Pool --> RAID-5 40 disks SAS + 8 disk SSD (easy tier) in 1 pool
mdisk10 --> 8 x 600 SAS RAID-5mdisk12 --> 8 x 600 SAS RAID-5mdisk14 --> 8 x 600 SAS RAID-5mdisk8 --> 8 x 600 SAS RAID-5mdisk9 --> 8 x 600 SAS RAID-5mdisk5 --> 8 x 400 SSD RAID-5Note: But for this testing, SSD still not being used because stress test period less than 8 hours.
A.2 DS5000 virtualized by V7000 --> RAID-5 40 FC disks in 5 volume virtualized into 1 pool
V7000_A1 8 FC disksV7000_A2 8 FC disksV7000_A3 8 FC disksV7000_A4 8 FC disksV7000_A5 8 FC disks
A.3 Flashsystem 720 virtualized by V7000 RAID-5 virtualized into 1 pool
8 LU with each 300GB and 512B sector size
A.4 Flashsystem 720 direct connect to host RAID-5 2 LU 500GB and 512B sector size
Configuration: 50GB VMDK for virtual disk on each tested datastore assigned to 2 VMs.
B. Server Testing Environment:2 servers for testing:
a. BSD-16 ESX server using Proliant DL 380 G7 with CPU Xeon X5690
- 2 HBA with 2 ports each for connection to storage
- VM on Windows Server 2008 with configuration:
b. BSD-18 ESX server using Proliant DL 380 G7 with CPU Xeon X5680
- 1 HBA with 1 ports each for connection to storage
- VM on Windows Server 2008 with configuration:
o 4 CPU
o 8GB memory
C. Zoning
SANSWITCH SAN_30IFSport 4 20:04 --> alias = ifs_1aport 5 20:08 --> alias = ifs_2a
V7000:port 2 cd:04 --> alias = v7000_a1port 3 cd:05 --> alias = v7000_b1
DS5300port 0 20:36 --> alias = ds5300_a6port 1 20:57 --> alias = ds5300_b6
HOST on ESXBSD_16 (2 ports)
BSD_18 (1 ports)
zonezone-1 = v7000_a1 ifs_1azone-2 = v7000_b1 ifs_2a
zone-3 = BSD_16_p1_ifs_1azone-4 = BSD_16_p2_ifs_2a
zone-5 = BSD_18_p1_ifs_1azone-6 = BSD_18_p1_ifs_2a
SANSWITCH SAN_40IFSport 5 21:04 --> alias = ifs_1bport 6 21:08 --> alias = ifs_2b
V7000:port 3 cd:04 --> alias = v7000_a4port 4 cd:05 --> alias = v7000_b4
DS5300port 0 20:56 --> alias = ds5300_b7port 1 20:37 --> alias = ds5300_a7
HOST on ESXBSD_16 (2 ports)BSD_18 (1 ports)
zonezone-1 = v7000_a4 ifs_1bzone-2 = v7000_b4 ifs_2b
zone-3 = BSD_16_p3_ifs_1bzone-4 = BSD_16_p4_ifs_2b
zone-5 = BSD_18_p2_ifs_1bzone-6 = BSD_18_p2_ifs_2b
- 2 VM in different ESX server. Each use 4 CPU
BSD_16 2 ports
D. Performance TestingAssigned virtual harddisk formatted using NTFS with allocation unit size 8KB.
Performance tested using iometer on the VM with configuration: random access 67%read and 33%write using blocksize 8KB.
D.1 internal disk on V7000Outstanding I/O or queue depth = 50
Summary Performance Testing Result
Datastore LocationResult on VM-1 Result on VM-2 Result
IOPS Latency IOPS Latency IOPS Latency
Internal disks V7000 3036 16ms 3056 16ms 6092 16ms
DS5300 Virtualized by V7000 1875 16ms 2529 12ms 4404 14ms
Flash720 virtualized by V7000 (cache enable) 11072 5ms 11920 4ms 22992 5ms
Flash720 virtualized by V7000 (cache disabled) 16215 3ms 16624 3ms 32839 3ms
Flash720 direct connect to hosts 46291 1ms 53881 1ms 100172 1ms
Flash720 direct connect with 4 volumes 73610 1ms 71023 1.5ms 144633 1.5ms