Self contained luminaires GuideLed AT - Cooper CSA · • LED self contained luminaire with...

8
Self contained luminaires GuideLed AT Showing the way Powered by Li Ion + -

Transcript of Self contained luminaires GuideLed AT - Cooper CSA · • LED self contained luminaire with...

Page 1: Self contained luminaires GuideLed AT - Cooper CSA · • LED self contained luminaire with automatic test for reduced inspection effort • Universal use for maintained and non-maintained

Self contained luminaires GuideLed AT

Showing the wayPowered by

LiIon

+

-

Page 2: Self contained luminaires GuideLed AT - Cooper CSA · • LED self contained luminaire with automatic test for reduced inspection effort • Universal use for maintained and non-maintained

2

GuideLed AT

1

2

4

3

5

Page 3: Self contained luminaires GuideLed AT - Cooper CSA · • LED self contained luminaire with automatic test for reduced inspection effort • Universal use for maintained and non-maintained

3

1 LED Lightguide technology

•Uniformbrightnessacc.toEN1838

•Lowenergyrequirements

•3-ChipLEDsforincreasedsafety

with50,000hservicelife

2 Automatic test electronics

•Fullyautomaticfunctiontest(weekly)or

durationtest(every6months)for

lowinspectionefforts

•Universaluse:Formaintainedmode,

non-maintainedmodeandswitchedmode

viaL'input

3 Display and test unit

•Testingbuttonformanualtriggeringof

functiontestanddurationtest

•Simplefaultanalysisandstatusinformationvia

displaywithbicolorLED

4 Optimised connection technology

•Spaciousinsertionareas

•Equippedforthrough-wiringofmainscable

viadoubleterminalsand2cableinfeeds

•Foreasyinstallation

5 Innovative LiIonen-technology

•Largecapacitywithsmallconstructionsize

forcompactluminairedesign

•Only1versionfor1h,2hand3h

emergencylightingoperationeasesreplacement

purchase

•Simplereplacementviapolarityreversal-protected

plug-incontactsandsnapmounting

Powered by

LiIon

+

-

4

Equipped with snap-in

pictogram set for universal application

Display via bicolor LED

Operating mode

Normalmode

Emergencylightingoperation

Follow-onemergencylight/

Functiontestactive

Durationtestactive

Fault message

Chargingfault

Functiontestfailed /

Durationtestfailed /

Lightsourcefault/

Durationtestisdue

LEDpermanenton LEDblinks

LEDoff LEDflashes

3

Page 4: Self contained luminaires GuideLed AT - Cooper CSA · • LED self contained luminaire with automatic test for reduced inspection effort • Universal use for maintained and non-maintained

3-Chip LEDs for increased safety

Longevity, instant start-up, high efficiency and

small construction size are the features that

make LEDs especially suitable for emergency

and safety lighting. But precise matching along

withlowtemperaturesandlowoperatingcurrent

guaranteeshighluminousefficacywithmaximum

servicelife.

Upto24LEDsoptimallyilluminatetheGuideLed

pictogram. Three LEDs are encapsulated in a

commonhousingtoformeachlightpoint.

If one of the three LEDs fails, the intact LEDs

illuminate more brightly. This ensures excellent

illuminationonapermanentlevel.

Lightguide technology for optimal

illumination

The highly developed Lightguide technology

convertsthehighpoint-sourcedluminanceofthe

LEDintoanilluminatedsurfacewithuniformbright-

ness.Assuchtheescapesignalwaysremainseasily

recognisableevenwithpoorvisibilityconditions.

Lithium ion battery technology

Lithium ion batteries with identical capacity re-

quiremuch lessspace thanNiCdorNiMhcells.

Thisleavesmorespaceforcompactdesignsand

cablerouting.

The so-called memory effect familiar with NiCd

andNiMhcellsisirrelevantwithlithiumioncells.

Permanent safety

Capacitylossesfromageinghavebeenconside-

redbycorrespondingdimensioningofthecells.

Amultipleprotectivecircuitintegratedinthebat-

tery ensures safe operation and high reliability.

NiCd and NiMh batteries have a significantly

higher self-discharge and are therefore per-

manently charged. This is no longer necessary

with the newGuideLed luminaires, saving addi-

tionalenergycosts.

Efficient technology

• Low spacial requirement

• No memory effect

• Environmentally friendly

Efficient technology

Powered by

LiIon

+

-

Page 5: Self contained luminaires GuideLed AT - Cooper CSA · • LED self contained luminaire with automatic test for reduced inspection effort • Universal use for maintained and non-maintained

It's not only our pictograms that are green

The new lithium ion batteries are completely

devoid of toxic heavy metals such as lead and

cadmium.

Inadditiondue to lowself-charging, lessenergy

isrequiredforrecharging.

In combination with the efficient LED Light

guide technology, electricity consumption of

a GuideLed escape sign is up to 70 % less

than comparable self-contained luminaires with

fluorescentlamps.

Fluorescentlamp

GuideLeddouble-sided

GuideLedsingle-sided

Safely saving on maintenance costs

Fluorescent lamps in safety lighting have typical

service lives that means at least one round of

relamping yearly according to daily operational

times.

Effort for maintenance is significantly reduced

duetothehighLEDservicelifeofapproximately

50,000hours.

Comparison of the system effective power Psys in watts with mains operation

Viewingdistance20m Viewingdistance30m

12.5

4.23.6

10.9

3.6 3.3

Efficient technology

Page 6: Self contained luminaires GuideLed AT - Cooper CSA · • LED self contained luminaire with automatic test for reduced inspection effort • Universal use for maintained and non-maintained

• LED self contained luminaire with automatic test for reduced inspection effort• Universal use for maintained and non-maintained operation and for 1 h, 2 h or 3 h operation• Including pictogram kit (arrow down, left, right) acc. to ISO 7010• Environmentally-friendly due to modern lithium ion technology• Low operating costs via low connected load• Minimum maintenance effort and increased safety via use of 3-chip LEDs

with high service life (50,000 hours)• Optimal recognition via bright pictogram with high uniformity Lmin/Lmax > 0.6• Photometric data according to EN 1838 and ISO 30061• Simple fault analysis and status display via bicolor LED and testing button• 1 minute switch-back delay after mains return (according to DIN VDE 0100-718)

Ordering details

Scopeofdelivery OrderNo.

GuideLed106111-3h/DAT-Set-eforwallmounting,includingLED-supplyandpictogramkit(LEDpictogram+ISOarrowdown,left,right),20m

40071353575

GuideLed106211-3h/DAT-Set-eforceilingmounting,includingLED-supplyandpictogramkit(LEDpictogram+ISOarrowdown,left,right+blind),20m

40071353576

GuideLed106251-3h/DAT-Set-eforropesuspension,includingLED-supplyandpictogramkit(LEDpictogram+ISOarrowdown,left,right+blind),20m

40071353577

Viewing distance 20 m

LuminousfluxΦE /Φnom atendofratedoperatingtime 80%at1h;80%at2h;75%at3h

Housingmaterial Polycarbonate

Weight 0.64kg(10611AT) 0.70kg(10621AT)0.71kg(10625AT)

Housingcolour LightgreyRAL7035

Typeofmounting InsulationclassII(protectiveearthrequired)

Terminals Through-wiringfrommains(L,L’,N,PE)to2.5mm2

Connectionvoltage 220-240V,50Hz

Powerconsumptionmainsoperation (apparentpower/effectivepower)

3.8VA/3.3W106114.0VA/3.6W10621/10625

Permissibleambienttemperature Maintainedmode-5°Cto+30°C Non-maintainedmode0°Cto+35°C

Battery Lithiumion3.7V/2000mAh withmultipleprotectivecircuit

Lightsource LEDstripwith3-chipLEDs

GuideLed AT 20 m

EN 1838

LED 20 m

IP20

AT

226

226

134

202

41

204,

5

3

9691

134

20

88

366

16

4,6

185

20310027 27

19,5

56

GuideLed10611AT

GuideLed10611AT

GuideLed10621AT

GuideLed10625AT

200

26269

263

54

227

227

274

262

226

361

80

12

12

12

21,5

4,4

167

33

80

75

61

134

3313

4

62 92

19

2727 5015

200

26269

263

54

227

227

274

262

226

361

80

12

12

12

21,5

4,4

167

33

80

75

61

134

3313

4

62 92

19

2727 5015

GuideLed10625ATGuideLed10621AT

10611IP40

200

26 26 2693

54

227 80

56

51

21,5

4,4

33

39

36

337

204

57

Page 7: Self contained luminaires GuideLed AT - Cooper CSA · • LED self contained luminaire with automatic test for reduced inspection effort • Universal use for maintained and non-maintained

7

LED

Ordering details

Scopeofdelivery OrderNo.

GuideLed116111-3h/DAT-Set-eforwallmounting,includingLED-supplyandpictogramkit(LEDpictogram+ISOarrowdown,left,right),30m

40071353572

GuideLed116211-3h/DAT-Set-eforceilingmounting,includingLED-supplyandpictogramkit(LEDpictogram+ISOarrowdown,left,right+blind),30m

40071353578

GuideLed116251-3h/DAT-Set-eforropesuspension,includingLED-supplyandpictogramkit(LEDpictogram+ISOarrowdown,left,right+blind),30m

40071353579

Viewing distance 30 m

LuminousfluxΦE /Φnom11611 atendofratedoperatingtime11621/11625

95%at1h;95%at2h;90%at3h85%at1h;80%at2h;60%at3h

Housingmaterial Polycarbonate

Weight 0.77kg(11611AT) 1.04kg(11621AT)1.06kg(11625AT)

Housingcolour LightgreyRAL7035

Typeofmounting InsulationclassII(protectiveearthrequired)

Terminals Through-wiringfrommains(L,L’,N,PE)to2.5mm2

Connectionvoltage 220-240V,50Hz

Powerconsumptionmainsoperation (apparentpower/effectivepower)

4.0VA/3.6W116114.5VA/4.2W11621/11625

Permissibleambienttemperature Maintainedmode-5°Cto+30°C Non-maintainedmode0°Cto+35°C

Battery Lithiumion3.7V/2000mAh withmultipleprotectivecircuit

Lightsource LEDstripwith3-chipLEDs

GuideLed AT 30 m

30 mAT

• LED self contained luminaire with automatic test for reduced inspection effort• Universal use for maintained and non-maintained operation and for 1 h, 2 h or 3 h operation• Including pictogram kit (arrow down, left, right) acc. to ISO 7010• Environmentally-friendly due to modern lithium ion technology• Low operating costs via low connected load• Minimum maintenance effort and increased safety via use of 3-chip LEDs

with high service life (50,000 hours)• Optimal recognition via bright pictogram with high uniformity Lmin/Lmax > 0.6• Photometric data according to EN 1838 and ISO 30061• Simple fault analysis and status display via bicolor LED and testing button• 1 minute switch-back delay after mains return (according to DIN VDE 0100-718)

326

184

202

41

4,5

3

96

326

91

184

20 88

366

16

4,6

185

20310027 27

19,5

56

GuideLed11611AT

GuideLed11611AT

GuideLed11621AT

GuideLed11625AT

12

300

26 26 263

54

21,5

4,4

327

327

80

12

12

80

267

3333

184

374

362

326

46175

61

184

62 92

19

2727 5015

6

12

300

26 26 263

54

21,5

4,4

327

327

80

12

12

80

267

3333

184

374

362

326

46175

61

184

62 92

19

2727 5015

6

GuideLed11625ATGuideLed11621AT

EN 1838

IP20

11611IP40

300

2626 263

54

327 80

56

5121,5

4,4

33

39

36

337

304

57

Page 8: Self contained luminaires GuideLed AT - Cooper CSA · • LED self contained luminaire with automatic test for reduced inspection effort • Universal use for maintained and non-maintained

400 71 860 158/5/02.12/WD Technical details subject to alteration Valid from February 2012

CEAG Notlichtsysteme GmbHSenator-Schwartz-Ring 26 D-59494 SoestPhone +49 (0) 29 21/69-8 70Fax +49 (0) 29 21/69-617 Internet www.ceag.deE-mail [email protected]

Cooper SafetyJephson CourtTancred CloseRoyal Leamington SpaWarwickshire CV31 3RZUnited Kingdom Phone: +44 (0) 19 26/43 92 00Fax: +44 (0) 19 26/43 92 40Web: www.cooper-safety.comE-mail: [email protected]

©2012 CEAG Notlichtsysteme GmbH

Cooper Industries plc5 Fitzwilliam SquareDublin 2, Irelandwww.cooperindustries.com