Self-Contained Air Conditioner with No Heat Unit... · 2017-04-27 · High Voltage 1(800) 865-5931...
Transcript of Self-Contained Air Conditioner with No Heat Unit... · 2017-04-27 · High Voltage 1(800) 865-5931...
High Voltage
1(800) 865-5931www.alpinehomeair.com
Self-Contained Air Conditioner with No Heat
24 Volt+
Fan Only Operation
Common
Cooling
17Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTE
Y
Y
High Voltage
1(800) 865-5931www.alpinehomeair.com
Self-Contained Air Conditioner with Single Stage Electric Heat
24 Volt+
Fan Only Operation
Common
Cooling
Heat
18Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTE
Y
Y
W1
W1
W1
Thermostat, 2 stage cool
High Voltage
1(800) 865-5931www.alpinehomeair.com
Self-Contained Two-stage Air Conditioner with Single Stage Electric Heat
24 Volt+
Fan Only Operation
Common
Stage 1 Cooling
Stage 2 Cooling
Heat
19Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTE
Y1
Y2
Y1
Y2
Y1
Y2
Thermostat, 2 stage heat
Jumper
High Voltage
1(800) 865-5931www.alpinehomeair.com
Self Contained Air Conditioner with Two-Stage Electric Heat
24 Volt+
Fan Only Operation
Common
Stage 1 Heat
Stage 2 Heat
Cooling
20Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire. *You can make an optional jumper at W1 and W2 for single stage heat.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTE
Y
W1
Y
W1
Y
W1*
Thermostat, 2 stage heat, 2 stage cool
High Voltage
1(800) 865-5931www.alpinehomeair.com
Self-Contained, Two Stage Air Conditioner with Two Stage Electric Heat
24 Volt+
Fan Only Operation
Common
Stage 1 Heat
Stage 2 Heat
Stage 1 Cool
Stage 2 Cool
21Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTE
W1
W1
W1
Y1
Y2
Y1
Y2
Y1
Y2
High Voltage
1(800) 865-5931www.alpinehomeair.com
Two Stage Self-Contained Heat Pump with No Backup (AUX) Heat Control Wiring
24 Volt+
Fan Only Operation
Common
Reversing Valve
Stage 1 Cool/Heat
Stage 2 Cool/Heat
22Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTE
O
O
RHJumper
ORC
Self-Contained Unit
Y2
Y2
Y2
Y1
Y1
Y1
High Voltage
1(800) 865-5931www.alpinehomeair.com
Self-Contained Heat Pump with Two Stage Backup (AUX) Heat
24 Volt+
Fan Only Operation
Common
23Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTE
O
O
RC
RHJumper
O
AUX/E
Y
AUX/E
Jumper
Self-Contained Unit
Y1
W1
Electric Backup Heat
Reversing Valve (cooling)
Cooling/Heating
High Voltage
1(800) 865-5931www.alpinehomeair.com
Self-Contained Heat Pump with Single Stage Backup (AUX) Heat
24 Volt+
Fan Only Operation
Common
Cooling/Heating
Electric Backup Heat
Reversing Valve (cooling)
24Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTE
O
RC
RHJumper
AUX/E
O
Y
AUX/E
O
W1
Standard Thermostat
High Voltage
1(800) 865-5931www.alpinehomeair.com
Self-Contained, Single Stage Gas Furnace with Single Stage Cooling (Gas Pack)
24 Volt+
Fan Only Operation
Common
Heat
Cooling
25Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTE
W1
Y
Y
Y
Thermostat, 2 stage heat, 2 stage cool
High Voltage
1(800) 865-5931www.alpinehomeair.com
Self-Contained, Two Stage Gas Furnace With Two Stage Cooling (Gas Pack)
24 Volt+
Fan Only Operation
Common
Stage 1 Heat
Stage 2 Heat
Stage 1 Cool
Stage 2 Cool
26Some AC Systems will have a blue wire with a pink stripe in place of the yellow or Y wire.
This diagram is to be used as reference for the low voltage control wiring of your heating and AC system. Always refer to your thermostat or equipment
installation guides to verify proper wiring.
NOTE
W1
W1
W1
Y1
Y2
Y1
Y2
Y1
Y2