SHARE 0 Recommend Photo Galleries 7 Things You Probably Didn’t Know About Solar Power 1 Think you're up to date on solar pow er? You might be surprised to learn these seven facts. EC&M White Papers Know Your TCO: A Look at Medium NEC Design Ops & Maintenance Contractor Safety Power Quality Training Basics Products REGISTER LOG IN

description

Selecting Torque for Top Motor Efficiency - (EC&M) Magazine

Transcript of Selecting Torque for Top Motor Efficiency - (EC&M) Magazine

Page 1: Selecting Torque for Top Motor Efficiency - (EC&M) Magazine

Forum Subscribe About Us Magazine Issues Newsletters Advertise Shop

Jan 1, 1999

Tweet COMMENTS 0

Selecting Torque for Top Motor EfficiencyRobert J. Lawrie | Electrical Construction and Maintenance

Sure, horsepower is an important motor parameter. However, torque is just as important. That said, what

exactly is torque? It really depends on your point of view. If you're the motor, your shaft exerts the torque's

turning effort. As such, we call it motor torque. We commonly measure it in pounds-feet (lb-ft.). If you're

the load, torque is the turning effort you require at your input shaft for your

Sure, horsepower is an important motor parameter.

However, torque is just as important. That said, what

exactly is torque? It really depends on your point of view.

If you're the motor, your shaft exerts the torque's turning

effort. As such, we call it motor torque. We commonly

measure it in pounds-feet (lb-ft.). If you're the load, torque

is the turning effort you require at your input shaft for your

proper operation. In this context, we call it load torque, also measured in lb-ft. Basically,

you should consider torque both as it pertains to the demands of the load you want to

drive, and as it applies to the capabilities of the driving motor.

Regardless of your point of view, selecting the best and most efficient motor for the job

(based on first-cost and operating costs) depends directly on its torque. Remember, a

motor's operating efficiency falls off rapidly at lower values of torque loading.

Motor ratings and nameplates are standardized in terms of horsepower and speed,

with no mention of torque. However, you can relate horsepower and torque with the

following equation: Horsepower = Torque (lb-ft) x rpm/5250

Cost differentials.

Up-front cost. It's the design torque rating of the motor that most directly affects its

material cost. For example, a 10-hp, 1200-rpm motor costs more than a 10-hp, 1800-

rpm motor, because the former's rated torque is nearly 50% greater. Likewise, a 10-hp,

900-rpm motor costs even more, because its rated torque is almost 100% greater than

that of an 1800-rpm motor.

This also helps explain why you don't see motors with synchronous speeds lower than

900 rpm very often; it's usually more economical to use an 1800-rpm motor instead, and

add any necessary gearing or pulleys to obtain the desired speed.

Operating cost. The operating cost of a motor depends on its efficiency at a given

condition of loading. This applies to existing standard induction motors as well as energy-

efficient (EE) motors.

Hot Topics Comments New Topics

Tip of the Week: Don’t Blow it on the

Measurement Front

Tip of the Week: The Practical Safeguarding of

Persons and Property

Electrical Troubleshooting Quiz - June 23,

2015

Curing Customer Confusion, Part 2

Tip of the Week: Play it Safe with a Divide and

Conquer Strategy

Jo in the Discussion on EC&M Talk

New 3,000 Amp Service 1

la st r eply by Pa u l A bern a t h y in Power

Dist ribu t ion

T12 Electronic Ballast Resetting Problem 3

la st r eply by T odd H. in Gen era l Elect rica l

T a lk Discu ssion

LED Office Lighting 6

la st r eply by Nilsson 121 in Ligh t in g &

Ligh t in g Con t rols

HOME > CONTENT > SELECTING TORQUE FOR TOP MOTOR EFFICIENCY

SHARE 0Recommend

Photo Galleries

7 Things You Probably

Didn’t Know About

Solar Power 1

Think you're up to date on

solar pow er? You might

be surprised to learn

these seven facts.

EC&M White Papers

Know Your TCO: A

Look at Medium

NEC Design Ops & Maintenance Contractor Safety Power Quality T raining Basics

Products

Electrical Construction & Maintenance (EC&M)

REGISTER LOG IN

Page 2: Selecting Torque for Top Motor Efficiency - (EC&M) Magazine

Tweet

For competitive manufacturing-cost reasons, manufacturers generally design motors to

have peak efficiency at or near the full-load nameplate rating. You can see this in the

accompanying diagram, on page 44. Notice how rapidly efficiency deteriorates below the

approximate 50% level of nameplate load. The reason for this decline is: About one-third

of the losses in a typical motor will vary with load torque, while the remaining losses are

essentially constant.

Because of these fixed losses, a large cost penalty occurs if you operate a motor at low

values of loading.

Selection guidelines. From the foregoing cost factors, you should focus on two

important selection and application guidelines:

In some manufacturing plants, preexisting conditions may exist, which may prevent you

from applying these rules. In any case, you must be aware of the cost penalties involved if

you cannot "load-match," size appropriately, or operate the motor you select according to

guidelines.

You can use many different techniques to comply with these two guidelines. It's

important you research the numerous considerations applying to proper motor selection

and operation. We'll cover these in the March issue. Future Motor Facts articles will

discuss how steady-state, acceleration, and starting torque reduce motor operating costs.

Please Log In or Register to post comments.

Related Articles

Matching Motor Torque To Your Load

Guidelines for motor application designs.

Choosing a Motor for Efficient Operation

Effectively applying premium efficiency motors.

Understanding modern motors and controllers.

JUL 2 1 , 2 01 5

JUL 1 4 , 2 01 5

EC&M Webinars

SPONSORED

Mitigation Methods for

Arc Flash Hazards -

Enhancing Personal

Safety

SPONSORED

Understanding the

2015 Edition of NFPA

70E and the Arc Flash

Hazard

VIEW MORE WEBINARS

EC&M Learning Center

Understanding the 2014 NEC,

Volume 1 (Articles 90 to 480)

This resource has proven itself in the

field and in the exam room. This latest

edition w ill provide you w ith a rock-solid

foundation...

Understanding NEC Requirements for Grounding

vs Bonding

One of the most confusing areas of the trade continues

Buy only as much motor as you need: Avoid oversizing.

Minimize prolonged operation at light-load conditions.

SHARE 0Recommend

VIEW MORE WHITE PAPERS

Voltage VFDs

Learn about the intricacies

involved in calculating TCO

and the elements that

affect it....

More

EC&M TV

BROWSE ALL VIDEOS

New Certification

Announcement from

NFPA

...

More

Page 3: Selecting Torque for Top Motor Efficiency - (EC&M) Magazine

Site Features

Author Guidelines

RSS

Sitem ap

EC&M Corporate

Privacy Policy

T erm s of Service

About Us

Search ecmweb.com

Subscribe to the print magazine

Ecmweb.com

NEC Design Ops & Maintenance Contractor Safety Power Quality T raining Basics Products

to be grounding and bonding, w hich is

w hy this book needs to be in the

hands...

Changes to The NEC 2014

Don't let the scale of the code changes

intimidate you, this book w ill get you up

to speed on the most essential...

BROWSE ALL TITLES

COUNTRY*

E-MAIL*

Sign-up to receive our free newsletters

eTrain - (Bi-Weekly) View Sample

Product NewsWire - (Monthly) View

Sample

ElectricalZone - (Weekly) View Sample

MRO Insider - (Bi-Weekly) View Sample

PQ NewsBeat - (Bi-Weekly) View

Sample

Illumination Insider - (Bi-Weekly) View

Sample

CodeWatch - (Bi-Weekly) View Sample

G-Biz - (Varies) View Sample

Electrical Testing - (Monthly) View

Sample

United States

Enter your email above to receive messages about

offerings by Penton, its brands, aff iliates and/or third-

party partners, consistent w ith Penton’s Privacy Policy.

Connect With Us