Select-Info Packet Power presentation

20
Environmental monitoring Track power consumption Centralized vision by Packet Power SelectInfo 2013

description

Packet Power produce mesh wireless power cables and temperature/humidity sensors that delivers electrical power usage and environmental visibility. Robust wireless mesh Fully self-configuring Requires 1 IP address Simple to install and easy to use Vendor-neutral Accurate Serves ICT devices and facilities Low cost per measurement point Solution Components: Wireless Monitors Smart power cables and panels Environmental Sensors Plug and Play Network Self-configuring adaptive wireless network Highly secure (Packet Power’s own wirless protocol) Monitoring, Analysis and Reporting Software Real-time data analysis and reporting Cloud base or PC based software SNMP and Modbus solo/enterprise option SMS and email alerts Security issues: Physical security Proprietary, secure wireless protocol inaccessible by common hacking tools (not 802.11, ZigBee, or BT) Random frequency-hopping protocol Out-of-band and “cloudless” deployment options Physically continuous cable (no power flow interruptions) Data transmission security Packet-level encryption at the radio link level All measurement data optionally encrypted with 256-bit cable-specific irretrievable key embedded in the cable HTTPS link security AES report data file encryption option Data access security Decrypt and access data only from your licensed nodes Impossible to decrypt cable data without a cable key Standard password-protected HTTPS web access Separation of measurement data and customer information How can I get notified if my AC units go down? How can I know if temperature of various zones at my DC are as required? Do I need to increase my current cooling capacity? Can my current cooling setup handle my future expansion plans? Live reading on temperature and Humidity levels Reports on historical environment behavior User defined thresholds and alarms SMS and e-mail alerts 10 temperature probes per unit multiple facility centralized analyzing and management Local software application or Packet Power’s cloud based service Probe temperature reading range -40 to 85° C High precision measurement (±1° C, ±2% RH) Map temperature readings to facility layout diagram Create historical reports Export to CSV file Create and publish dashboards and QR labels How can I get informed if a device is about to fail? How much power is my DC, Rack or Server consumes? And how can I reduce it? Do I need to expand my electric power infrastructure to cope with my future growth plans?

Transcript of Select-Info Packet Power presentation

Page 1: Select-Info Packet Power presentation

Environmental monitoring Track power consumption Centralized vision

by Packet Power

SelectInfo 2013

Page 2: Select-Info Packet Power presentation

step into the future

SelectInfo

Page 3: Select-Info Packet Power presentation

step into the future

About SelectInfo

Established 2003 as technology related company Lebanese company CR No. 1000986 Capital 750,000,000 LBP Offices at Lyan Center, Hotel Dieu, Ashrafieh Partners: Some of our reputed clients:

Page 4: Select-Info Packet Power presentation

step into the future

Packet Power

Page 5: Select-Info Packet Power presentation

step into the future

About Packet Power

Established in 2007 and incorporated in Minnesota Founded by Paul Bieganski, Ph.D. Offices: 201 6th St SE, Suite #1 Minneapolis, MN 55414, USA 39 distributers and resellers in USA, Eorupe, Mexico, India, South Africa, New Zealand, Canada, UAE and Lebanon Made in USA, Assembled in USA

Member of :

Software Integrations:

Page 6: Select-Info Packet Power presentation

step into the future

Why Packet Power: Packet Power produce mesh wireless power cables and temperature/humidity sensors that delivers electrical power usage and environmental visibility.

Robust wireless mesh Fully self-configuring Requires 1 IP address Simple to install and easy to use Vendor-neutral Accurate Serves ICT devices and facilities Low cost per measurement point

Wireless 3 Ph. Power Panel Wireless

Power Cord

Wireless 3 Ph. Power Cord

Wireless Environmental

Sensors

Wireless Ethernet Gateway

Page 7: Select-Info Packet Power presentation

step into the future

Solution Components:

Wireless Monitors

Smart power cables and panels

Environmental Sensors

Plug and Play Network

Self-configuring adaptive wireless network

Highly secure (Packet Power’s own wirless protocol)

Monitoring, Analysis and Reporting Software

Real-time data analysis and reporting

Cloud base or PC based software

SNMP and Modbus solo/enterprise option

SMS and email alerts

Page 8: Select-Info Packet Power presentation

step into the future

Security issues:

Physical security Proprietary, secure wireless protocol inaccessible by common hacking tools (not 802.11, ZigBee, or BT) Random frequency-hopping protocol Out-of-band and “cloudless” deployment options Physically continuous cable (no power flow interruptions)

Data transmission security

Packet-level encryption at the radio link level All measurement data optionally encrypted with 256-bit cable-specific irretrievable key embedded in the cable HTTPS link security AES report data file encryption option

Data access security Decrypt and access data only from your licensed nodes Impossible to decrypt cable data without a cable key Standard password-protected HTTPS web access Separation of measurement data and customer information

Page 9: Select-Info Packet Power presentation

step into the future

Environmental Monitoring

How can I get notified if my AC units go down? How can I know if temperature of various zones at my DC are as required? Do I need to increase my current cooling capacity? Can my current cooling setup handle my future expansion plans?

Page 10: Select-Info Packet Power presentation

step into the future

General Features

Live reading on temperature and Humidity levels Reports on historical environment behavior User defined thresholds and alarms SMS and e-mail alerts 10 temperature probes per unit multiple facility centralized analyzing and management Local software application or Packet Power’s cloud based service Probe temperature reading range -40 to 85° C High precision measurement (±1° C, ±2% RH)

Page 11: Select-Info Packet Power presentation

step into the future

Operational Features

Map temperature readings to facility layout diagram Create historical reports Export to CSV file Create and publish dashboards and QR labels

Quick summary on devices status for the past 24 hours

Number of alert messages still available

List of live temperature and humidity readings as per unit and probe

Gateways status and nods connections

List of facilities and layouts

Page 12: Select-Info Packet Power presentation

step into the future

Operational Features

Intuitive facility heat maps 3-D view of temperature data

Page 13: Select-Info Packet Power presentation

step into the future

How dose it all fit at BOB DC

Page 14: Select-Info Packet Power presentation

step into the future

Power Consumption

How can I get informed if a device is about to fail? How much power is my DC, Rack or Server consumes? And how can I reduce it? Do I need to expand my electric power infrastructure to cope with my future growth plans?

Page 15: Select-Info Packet Power presentation

step into the future

No electricians needed

Measure Amps, Volts, Volt-Amps, Watts, Watt hours, frequency and power factor by phase

Accurate to +/-1%

Panel based monitors with up to 24 circuits

No need to disrupt devices or disconnect power cables

From 10 to 2400 amps per phase

Maintains rolling 10-day repository of monitoring data

up to 20 cables per Gateway

General Features

Public Power Source

Generator

Transfer Switch

UPS

PDU

PC

Servers and Datacomm

Cooling

Page 16: Select-Info Packet Power presentation

step into the future

Operational Features

Create data center and branches facilities

Page 17: Select-Info Packet Power presentation

step into the future

Manually configure racks, or copy past

Operational Features

Page 18: Select-Info Packet Power presentation

step into the future

Create connections per device (left) or per Strip (right)

Operational Features

Page 19: Select-Info Packet Power presentation

step into the future

Start generate reports, dashboards, and QR codes

Operational Features

Page 20: Select-Info Packet Power presentation

SelectInfo 2013

Step into the future

SelectInfo