SEISMIC FORCE RESISTING SYSTEMS AND RESPONSES OF CONCRETE BUILDINGS TO SEISMIC FORCES
description
Transcript of SEISMIC FORCE RESISTING SYSTEMS AND RESPONSES OF CONCRETE BUILDINGS TO SEISMIC FORCES
Department of Civil EngineeringNED University Engineering & Technology
SEISMIC FORCE RESISTING SYSTEMS AND RESPONSES OF CONCRETE BUILDINGS TO
SEISMIC FORCES
Department of Civil EngineeringNED University Engineering & Technology
TOPICS COVERED Seismic Force Resisting Systems Building Configuration Response of Concrete Buildings
Department of Civil EngineeringNED University Engineering & Technology
SEISMIC FORCE RESISTING SYSTEMS Basic structure systems that may be used to resist earthquake forces include
Moment-Resisting Frame Systems Bearing Wall Systems Dual System Building Frame System Inverted Pendulum System
Department of Civil EngineeringNED University Engineering & Technology
MOMENT-RESISTING FRAME SYSTEMS A structural system with complete space frame for gravity loads Lateral forces are resisted by flexural action of frame members Entire space frame or portion may be designated as seismic-force-resisting system Three types of detailing of frames are possible based on the effects of seismic forces
Ordinary RC frames Intermediate moment frames Special moment frames
Department of Civil EngineeringNED University Engineering & Technology
BEARING WALL SYSTEMS A structural system without complete space frame for gravity loads Bearing walls provide support for gravity loads Lateral loads are also resisted by the bearing walls acting as shear walls Two types of detailing of walls are possible based on the effects of seismic forces
Ordinary RC shear walls Special RC shear walls
Department of Civil EngineeringNED University Engineering & Technology
DUAL SYSTEMS A structural system with the following features
Complete space frame for gravity loads 25% base shear resisted by space frames Resistance to lateral force is provided by the shear walls
Moment frames are either special or intermediate frames Different combinations of shear walls are possible including
Ordinary RC shear walls Special RC shear walls
Department of Civil EngineeringNED University Engineering & Technology
BUILDING FRAME SYSTEMS A structural system without complete space frame for gravity loads Lateral loads are resisted by the shear walls No interaction between the shear wall and frames is considered in the lateral load analysis Two types of detailing of walls are possible based on the effects of seismic forces and building height
Ordinary RC shear walls Special RC shear walls
Department of Civil EngineeringNED University Engineering & Technology
INVERT PENDULUM SYSTEMS Structures that have a large portion of mass concentrated near the top Essentially one degree of freedom Little redundancy and overstrength Inelastic behaviour concentrated at the base Less energy dissipation capacity than other systems
Department of Civil EngineeringNED University Engineering & Technology
BUILDING CONFIGURATION Buildings having irregular configurations in plan and/or elevation suffered
greater damage Inelastic behaviour concentrates in certain localized regions in irregular
structure Structural elements deteriorate rapidly in these areas Inelastic demand tend to be well distributed throughout a regular structure Elastic analysis methods are not capable to accurately predict distribution of
seismic demand in an irregular structure Building with regular configuration are encouraged and highly irregular
buildings are prohibited on sites close to active faults
Department of Civil EngineeringNED University Engineering & Technology
PLAN IRREGULARITIES Five different plan irregularities have been identified
Torsional irregularity Re-entrant corners Diaphragm discontinuity Out-of-plan offsets Nonparallel systems
Department of Civil EngineeringNED University Engineering & Technology
PLAN IRREGULARITIES Torsional irregularity
Department of Civil EngineeringNED University Engineering & Technology
PLAN IRREGULARITIES Re-entrant corners
Department of Civil EngineeringNED University Engineering & Technology
PLAN IRREGULARITIES Diaphragm discontinuity
Department of Civil EngineeringNED University Engineering & Technology
PLAN IRREGULARITIES Out-of-plan offsets
Department of Civil EngineeringNED University Engineering & Technology
PLAN IRREGULARITIES Nonparallel systems
Department of Civil EngineeringNED University Engineering & Technology
VERTICAL IRREGULARITIES Five different vertical structural irregularities have been identified
Stiffness irregularity-soft story Weight (mass) irregularity Vertical geometric irregularity In-plane discontinuity in vertical lateral-force-resisting elements Discontinuity in capacity-weak story
Department of Civil EngineeringNED University Engineering & Technology
VERTICAL IRREGULARITIES Stiffness irregularity-soft story
Department of Civil EngineeringNED University Engineering & Technology
VERTICAL IRREGULARITIES Weight (mass) irregularity
Department of Civil EngineeringNED University Engineering & Technology
VERTICAL IRREGULARITIES Vertical geometric irregularity
Department of Civil EngineeringNED University Engineering & Technology
VERTICAL IRREGULARITIES In-plane discontinuity in vertical lateral-force-resisting elements
Department of Civil EngineeringNED University Engineering & Technology
VERTICAL IRREGULARITIES Discontinuity in capacity-weak story
Department of Civil EngineeringNED University Engineering & Technology
RESPONSE OF CONCRETE BUILDINGS A reliable load path is necessary to transfer lateral forces to the foundation Earthquake forces are resisted by either walls or frame elements Foundation components transfer the force to the earth Key elements of the load path through the structure include
Diaphragm Walls Frames Foundations
Connections are also important components of the chain Resistance of building is as strong as the weakest link in the path
Department of Civil EngineeringNED University Engineering & Technology
DIAPHRAGM RESPONSE Diaphragms typically span between shear walls of concrete Respond like deep beams bending in their own plane under lateral forces Forces produced at the diaphragm edge include
Shear Tension or compression
Seismic forces acting perpendicular to the long side produce shear forces acting in the opposite direction Shear forces are transferred to the shear walls Tension develops in the chord and compression develops on the side on which seismic forces act
Department of Civil EngineeringNED University Engineering & Technology
DIAPHRAGM RESPONSE Forces similar to chord forces also develop around openings Openings may need to be reinforced with additional longitudinal steel Shear forces at the diaphragm edge are transferred through shear-friction Another mechanism of shear transfer is dowel action The assumption here is that reinforcement acts as anchor bolt in shear
Department of Civil EngineeringNED University Engineering & Technology
SEISMIC RESPONSE OF SHEAR WALLS Shear walls resist gravity loads and in-plane lateral forces They are like vertical cantilever deep beams Shear force from diaphragm causes bending moment and shear force in the
plane of the wall Tendency to overturn and slide is resisted by the foundation Bending moment increases from top to bottom of a building and causes
tension and compression forces in the wall plane Seismic response of short stocky shear wall is governed by shear Response of taller walls is governed by flexure
Department of Civil EngineeringNED University Engineering & Technology
SEISMIC RESPONSE OF SHEAR WALLS For walls with H/L between 1-2 response depends on several factors including
amount of shear reinforcing Shear dominated response is characterized by inclined (x-shaped) cracking
pattern The wall can loose strength rapidly with little warning
Department of Civil EngineeringNED University Engineering & Technology
SEISMIC RESPONSE OF FRAMES Response of frames is different than shear walls to lateral forces Frame resists by being deformed by lateral forces due to the rigidity of the
beam-column joints Beams and columns bend due to this rigidity Tension stresses caused by the bending must be resisted by the reinforcement Bending also causes vertical shear forces in beams and horizontal shear forces
in columns Vertical shear reinforcement is needed in beams and horizontal shear
reinforcement in columns
Department of Civil EngineeringNED University Engineering & Technology
FOUNDATION RESPONSE Foundations can be shallow or deep Shallow foundations are supported by vertical pressure of earth Foundation types include
Square or rectangular spread footings Continuous strip footings
Deep foundations consists of piles made of Wood Steel Concrete
Piles can be poured in place or driven piles
Department of Civil EngineeringNED University Engineering & Technology
FOUNDATION RESPONSE Piles are supported by end bearing and skin friction Connected together by ties, grade beams or slabs on grade Shear forces are transferred from walls and frames to the foundation Dowels in foundation must match the vertical reinforcement in walls and frames
Department of Civil EngineeringNED University Engineering & Technology
THANK YOU FOR YOUR ATTENTION !