The Affordable Solutionto Enhancing A/C orHeat PumpSystems
MADE IN THE USA
Hum
idit
y Re
mov
al
I n c re a s e d H u m i d i t y R e m ova l R ate *
82°F 97°F 112°F% Faster Humidity Removal with QwikSEER+ WattSaver™
Up to
566%Faster
HumidityRemoval
withQwikSeer+
WattSaver™
157%Faster
52%Faster
Increase Humidity Removal Rate up to 566%Indoor air quality (IAQ) is a vital factor in maintaining a healthy life. By reducing the humidity in a home, mold growth is avoided. According to the EPA (http://www.epa.gov/mold/preventionandcontrol.html), to prevent mold relative humidity should be maintained below 60%.QwikSEER+ WattSaver™ has been shown to improve humidity removal rates by up to 566%. This increased moisture removal can significantly improve indoor comfort while also inhibiting the formation of mold, thus improving IAQ.By connecting the optional humidity sensor (QT6001), the QwikSEER+ control board will also optimize the system for fastest humidity removal during high-humidity situations.
Additional Features of QwikSEER+ WattSaver™
` Added Blower Motor Protection QwikSEER+ WattSaver’s™ patented design incorporates high-voltage electrical protection for voltage spikes.
` 1 Year Limited WarrantyContact Mainstream Engineering Corporation for details.
*Based on Independent Laboratory Testing at Intertek (Plano, Texas) of a 14 SEER system. For complete test results, go to www.qwik.com.
4
SIMPLE INSTALLATIONDisconnect 2 Wires from Blower Motor
Connect 2 Wires from Control Board/Relayto QwikSEER+™ Board
AConnect 4 Wires between QwikSEER+™ Board and Blower Motor
B CConnect 2 Wires from Control Board/Relayto QwikSEER+™ Board
1MOUNT BRACKETTO CABINET
A
B
2THERMISTOR TO A-COIL
FUSE: 250VAC, 20ATIME DELAY
OUTPUTS TO BLOWER MOTOR
LINEINPUT(FROM CONTROLBOARD OR RELAY)90-240VAC50-60Hz16A MAX
5VD
C Si
de90
-240
VAC
Side
COOLL2
COML1
P7 P4 P3 P8
K3
K2
K1
GREENto Ground
BLWR LOWL2 - LOW
BLWR MEDL2 - MED
BLWR HIGHL2 - HIGH
From Control Board or Relay
Cool Mode (Motor Speed Tap)
From Control Board or Relay Cool Mode(Common Wire)
BLWRL1/COM
REDto BlowerLow Speed Tap
Thermistor
BLUEto BlowerMed Speed Tap
BLACKto BlowerHigh Speed Tap
PURPLEto Blower Common
BRAC
KET
SIDE
QT6001Humidity Sensor (if equipped)
QwikSEER+ WattSaver™P/N QT6000MADE IN THE USAPATENTS PENDING
CONNECT WIRESSEE SIMPLIFIED WIRING DIAGRAM
3ATTACH PCB TO BRACKET
For PSC (Permanent-Split Capacitor) Motors Only 90VAC-240VAC / 1Phase - 16 amp maximum
*Read Complete Instruction Manual Before Installing!
7-13%*EER IMPROVEMENT.7-13%
*EER IMPROVEMENT.
EER
Impr
ovem
ent (
%)
97°F
1 4 S E E R U N I T T E S TE n e rg y E� c i e n c y R at i o I m p rove m e nt
82°FOutdoor Temperature
SEER14 Furnace with A/CSEER14 A/C
14
0
2
4
6
8
10
12 12.9
10.9 10.5
7.4
MAINSTREAM ENGINEERING CORPORATION200 Yellow Place • Rockledge, Florida 32955
321-631-3550
Compatible with A/C or heat pump systems
that either use PSC blower motors or can be fitted with PSC motors.
*Based on Independent Laboratory Testing at Intertek (Plano, Texas) of a 14 SEER systems. For complete test results, go to www.qwik.com.
QwikSEER+ WattSaver™ Specifications
Input Voltage Range 90 - 240VAC
Maximum Steady-State Current 16 Amps
Maximum Blower Hp ¾ Hp
Frequency 50 - 60 Hz
Fuse Rating 20 Amps Time Delay
Surge Suppression 6,000 Amps, 100 Joules
Size / Dimensions 4.3” x 5.3”
Supported Accessories QT6001 QwikSEER+ Humidity Sensor™
QwikSEER+
WattSaverWattSaverWattSaver `Automatic Operation
`Proven Performance
`Simple Installation
™
A Qwik Performance Upgrade to New or Existing Systems.What does this all mean…?QwikSEER+™ can save save homeowners as much as 7-13%* annually on their air conditioning operating costs. Finally, you can provide a low-cost alternative to expensive deluxe systems. Although deluxe systems can provide these savings and possibly more, they can cost thousands more than a standard system.
Here’s how it works…QwikSEER+™ is an innovative and cost-effective electronic control that operatesin the cooling mode of an existing airconditioner or heat pump. By using the existing speeds taps of a PSC motor, the QwikSEER+ control board selects the best possible airflow based on conditions in the home. This enhances system performance while providing energy savings and improved humidity removal.
Fast InstallationBecause of the QwikSEER+’s™ exclusive “plug & play” design, you won’t need to change any of the system controls or the current thermostats. QwikSEER+™ handles everything automatically and is compatible with your existing system.
The choice is simple...Now you can offer your homeowners an affordable solution that will lower the energy costs of their existing systems (by about 10%) and increase the rate of humidity removal.
*Independent Laboratory Testing at Intertek (Plano, Texas) following ANSI/ASHRAE 37 test protocol and using a residential 14 SEER air handler and condensing unit (80°F indoor, 97°F outdoor temperatures) resulted in an EER improvement of 7.4%. Using the same condensing unit and temperature conditions with a residential furnace unit resulted in an EER improvement of 10.5%. On cooler days, (82°F outdoor temperature), the EER improve-ments for air conditioning and furnace units increased to 10.9% and 12.9%, respectively. For complete test results, go to www.qwik.com.