SeedStar 1990 CCS Quick Reference Guide...A89898 SeedStar TM2 1990 CCS Quick Reference Guide...

2
A89898 SeedStar TM 2 1990 CCS Quick Reference Guide SeedStar TM 2 1990 CCS Quick Reference Guide Population At a Glance Black bars indicate row is seeding normally. Orange bars indicate row is seeding above or below alarm setpoints. Red bars indicate row is not seeding. Drives Status Bar Green bar indicates that clutch is engaged and drives are active. Gray bar indicates that clutch is disengaged and drives are inactive. Select Toggle button to switch between Scan mode and Population At A Glance mode. Average Seeds per Area displays the actual average rate. Select button to toggle between entire machine average and drive section average. Population and Rates 1990 CCS – Main Select for main run screen. Blockage – Configuration Select to change blockage detection pattern. Population – Setup Select to change population targets and alarms. Totals Select to view covered area, hours, and calculators. Diagnostics Select to view sensor readings and fault codes. F 1, 2, 3 G H 1, 2, 3 I J White: Drive is inactive. Sensor is on Green: Product flow is detected. Red: Hose blocked or, Black if SwathControl TM deactivates sensors. Getting Started (seeds/ac) (seeds/ac) 106.2 0.0 9:52 am SeedStar2 1990 CCS_A89898.indd 1 08/27/2010 10:02:12 AM

Transcript of SeedStar 1990 CCS Quick Reference Guide...A89898 SeedStar TM2 1990 CCS Quick Reference Guide...

Page 1: SeedStar 1990 CCS Quick Reference Guide...A89898 SeedStar TM2 1990 CCS Quick Reference Guide Population At a Glance Black bars indicate row is seeding normally. Orange bars indicate

A89898

SeedStar TM2 1990 CCS Quick Reference GuideSeedStar TM2 1990 CCS Quick Reference GuidePopulation At a Glance

Black bars indicate row is seeding normally.

Orange bars indicate row is seeding above or below alarm setpoints.

Red bars indicate row is not seeding.

Drives Status Bar

Green bar indicates that clutch is engaged and drives are active.

Gray bar indicates that clutch is disengaged and drives are inactive.

Select Toggle button to switch between Scan mode and Population At A Glance mode.

Average Seeds per Area displays the actual average rate. Select button to toggle between entire machine average and drive section average.

Population and Rates

1990 CCS – MainSelect for main run screen.

Blockage – ConfigurationSelect to change blockage detection pattern.

Population – SetupSelect to change population targets and alarms.

TotalsSelect to view covered area, hours, and calculators.

DiagnosticsSelect to view sensor readings and fault codes.

F

1, 2, 3

G

H

1, 2, 3

I

J

White: Drive is inactive. Sensor is on Green: Product flow is detected. Red: Hose blocked or, Black if SwathControlTM deactivates sensors.

Getting Started

(seeds/ac)

(seeds/ac)106.20.0

9:52 am

SeedStar2 1990 CCS_A89898.indd 1 08/27/2010 10:02:12 AM

Page 2: SeedStar 1990 CCS Quick Reference Guide...A89898 SeedStar TM2 1990 CCS Quick Reference Guide Population At a Glance Black bars indicate row is seeding normally. Orange bars indicate

A89898

Counting Setup

Select Menu >

> Blockage and Counting button >

>

Counting Configuration softkey >>

Setup tab. Select or deselect Single Rank check box to m

atch machine design.

If machine has tw

o ranks, select Row W

idth drop down m

enu and select current w

idth. With both ranks seeding, select narrow

spacing. W

ith single rand seeding, select wide spacing.

Target Population

Upper Alert Limit

Lower Alert Lim

it

Select Population tab. Select Target Population input box and enter the intended seeding rate. Select Alert Lim

it input boxes and enter actual values or percentage of target.

Select Population Adjust drop down m

enu. Perform a field rate

check. Divide actual population by the displayed population, m

ultiply result by 100, and enter value for population adjustment.

Speed Source

The Active Speed Source is always displayed in the speed field

on the planter run page.

Radar (Ground Based) Speed

Tractor Wheel Speed

Manual (Fixed) Speed

Satellite (GPS) Speed

Select Menu >

> Blockage and Counting button >

> Counting

Configuration softkey >>

Population tab.

Select Speed Source drop down at bottom

of screen.

Blockage Setup

Select Menu >

> Blockage and Counting button >

> Blockage

Configuration softkey >>

Run Setup tab >>

Row Fail Rate

drop down.

Select a level of sensor response. Once seed rate is verified in the field, set the level as sensitive as possible w

ithout triggering nuisance alerts. Sorghum

and Milo m

ust be set for 1 seed every 3 seconds.

Select Blockage Pattern drop down m

enu. Select a monitor

pattern. If the far left active row is on front rank, select Even

Rows On. If the far left active row

is on rear rank, select Odd Row

s On.

SeedStar TM2 1990 CCS Quick Reference GuideSeedStar TM2 1990 CCS Quick Reference Guide

O.0

O.0

0.0M

O.0

S/ac