SEE 3433 Elements of Armature Winding in DC Machines.

11
SEE 3433 Elements of Armature Winding in DC Machines

Transcript of SEE 3433 Elements of Armature Winding in DC Machines.

Page 1: SEE 3433 Elements of Armature Winding in DC Machines.

SEE 3433Elements of Armature Winding in

DC Machines

Page 2: SEE 3433 Elements of Armature Winding in DC Machines.

Elements of an armature windings

A turn – two conductors connected to an end by an end connector

Page 3: SEE 3433 Elements of Armature Winding in DC Machines.

Elements of an armature windings

A coil – several turns connected in series

Page 4: SEE 3433 Elements of Armature Winding in DC Machines.

Elements of an armature windings

A winding – several coils connected in series

Page 5: SEE 3433 Elements of Armature Winding in DC Machines.

Elements of an armature windings

The angle between centers of adjacent poles is 180o (electrical)

N

N

S S

360o electrical = 180o mech

180o electrical = 90o mech

Page 6: SEE 3433 Elements of Armature Winding in DC Machines.

Elements of an armature windings

The angle between centers of adjacent poles is 180o (electrical)

N

N

S S

If coil sides are placed 180o electrical apart, the coil is said to be full-pitch

a

b

180oelec

a b

Page 7: SEE 3433 Elements of Armature Winding in DC Machines.

Elements of an armature windings

The most common ways of connecting coils for armature windings:

Lap windingWave winding

Ends of the coils are connected to the commutator bars

In DC machines most of the coils are full-pitch.

Page 8: SEE 3433 Elements of Armature Winding in DC Machines.

Elements of an armature windings

Commutator bar

Lap winding

• One coil between adjacent commutator bars• 1/p of total coils are connected in series• No. of poles no. of brushes no. of parallel paths

Page 9: SEE 3433 Elements of Armature Winding in DC Machines.

Elements of an armature windings

Page 10: SEE 3433 Elements of Armature Winding in DC Machines.

Elements of an armature windings

Wave winding

• p/2 coils in series between adjacent commutator bars• ½ of all coils between brushes• Regardless of no. of poles, there are always 2 parallel path• The distance between end coils (commutator pitch) is 2(C1)/p

where C is the no. of commutator bars

Page 11: SEE 3433 Elements of Armature Winding in DC Machines.

Elements of an armature windings