Security Systems BU Communication Systems DCN SA PO CCE 01.Nov.0 6 ST/SEU-CO 1 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00

Transcript of Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control...

Page 1: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 1

Central Control Equipment

LBB3500/05

LBB4106/x0

LBB3508/00

Page 2: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 2

Central Control Unit (Com - port 1)

LBB3500/05 9-pin Sub-D connector

RS 232 for: Terminal mode

Factory testing Diagnostics

OR Camera Control

1

Page 3: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 3

CCU Trunk Communication Board (TCB-4)1 Jumper X14 for service only

2 S14 DIP- switches 1 – 8 Com-port settings

3 S10 Push- button switch to reset the Central Control Unit during servicing.

4 Three LEDs (left to right) green/ yellow/ red. Normally the green/ yellow LEDs flash in sequence, indicating the software is running. Red LED illuminates during system reset.

5 S9 DIP- switches 1 – 8 System modes

6 Yellow LED indicates Digital Signal Processing (DSP) software is running.

7 Connector for multi- trunk board (used only in the multi- CCU)

8 Sockets for inserting flash EPROM (even)

9 Sockets for inserting flash EPROM (odd)

Upgrade Kit

Page 4: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 4

CCU Trunk Communication Board (TCB-4)10 SRAM back- up battery 3.6 V (life- time 5 years min.)

11 Jumper X13 Battery back up

12 Fuse 3.15 amp (delayed)

13 Connector for multi- trunk board (used only in the multi- CCU)

14 Serial RS232 Port 1

15 Serial RS232 Port 2

Upgrade Kit

Page 5: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 5

Central Control Unit (Com - port 1) LBB3500/05

CCU Protocol and Serial Port settings - Protocol based for using Allegiant Video Switchers.For location of DIP- switches see;Table 4.5 and 4.6

LBB 3500/ 05 Port 1 for Camera ControlIn a single (stand- alone) CCU system only one COM- port (Port 1) is available:

Default settings are;• 8 data bits• No parity check• 1 Stop bit

InstallationThe maximum cable length between the CCU and the ‘Allegiant Video Switcher’ should not exceed 5 m (16.4 ft). Where longer distances are required an ‘current-loop interface unit’ should be used to ensure correct transmission.

I&O Manual

Page 6: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 6

TCB-4 DIP Switch Settings

(default)

I&O Manual

Page 7: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 7

Central Control Unit (Audio I/O)LBB3500/05

1. Asymmetrical Recorder In- & Outputs

2. 2 Asymmetrical line

input connectors

3. Symmetrical or 2 Asymmetrical line outputs

1

2

3

Page 8: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 8

Central Control Unit (Audio I/O) LBB3500/05

1. Tape/cassette recorder input and output (Cinch-type)Tape In Asym. nom. -33 dBV max. -3 dBVTape Out Asym. nom. -33 dBV max. -3 dBV

2. 2 Asymmetrical line input connectors (Cinch-type)

Line In Asym. nom. -18 dBV max. +12 dBV

3. Symmetrical/Asymmetrical line output connectors (Cinch-type)

Line Out Sym. nom. -12 dBV max. +18 dBV Line Out Asym nom. -18 dBV max. +12 dBV

Page 9: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 9

11

22

Trunk

Central Control Unit LBB3500/05 (Trunk Outlets)

1. Red LED overload indicators

2. Trunk outlet used for loop-through of the trunk-line-cable

Page 10: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 10

Trunk outlets For loop-through of the DCN trunk-line without regenerating the digital signal.Power handling capacity maximum: - 60 PCF per outlet- 90 PCF total for the three outlets of the CCU.

PCF = 60 max.

PCF = 90 max.

Central Control Unit LBB3500/05 (Trunk Outlets)

Page 11: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 11

1. Mains socket with built-in fuse

Nominal

Mains voltage Mains fuse Power Consumption

220, 230, 240 V AC. T- 2A (slow blow) 175 W

105, 115 V, 125 V AC. T- 4A (slow blow)

Warning:

All units must be powered via an earthed mains outlet.

11

115V-T4A/230V-T2A

Central Control Unit LBB3500/05

I&O Manual

Page 12: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 12

Extension Power Supply LBB4106/x0

1

3 4

2

Rear view

1. Trunk line cable 2. Overload indicators3. Trunk outlets4. Mains socket

Page 13: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 13

Extension Power Supply LBB4106/x0

(Trunk outlet / Tap-off ’s)

1 2 31 2 3

Trunk Tap-off 1.Red LED overload indicators

2.Trunk outlet used for loop-through of the trunk-line-cable

3.Tap-off outlets are used for trunk-cable splitting

Page 14: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 14

Extension Power Supply LBB4106/x0(Trunk outlet / Tap-off ’s)

Trunk outlet

For loop-through of the DCN trunk-line without regenerating the digital signal.Power handling capacity maximum: - 60 PCF per outlet- 180 PCF total for the three outlets of the EPS.Tap- offsFor Trunk-cable splitting with regenerating the digital signal.Power handling capacity maximum- 60 PCF per outlet- 180 PCF total for the three outlets of the EPS.

PCF = 60 max.

PCF = 180 max.

Page 15: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 15

1. Mains socket with built-in fuse

Nominal

Mains voltage Mains fuse Power Consumption

220, 230, 240 V AC. T- 4A (slow blow) 350 W

105, 115 V, 125 V AC. T- 5A (slow blow)

Warning:

All units must be powered via an earthed mains outlet.

11

115V-T4A/230V-T2A

Extension Power Supply LBB4106/x0

I&O Manual

Page 16: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 16

Audio Media Interface LBB3508/00

2

1

5 63

4

Rear view 1. Cinch Audio output sockets2. XLR Audio output sockets3. Trunk line cable 4. Overload indicators5. Trunk outlets6. Mains socket

Page 17: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 17

Audio Media Interface LBB3508/00 (Audio outputs)

1 2

Output 1 Output 2 Output 3 Output 41. 4 Asymmetrical Audio output connectors

(Cinch-type)

2. 4 Symmetrical (transformer balanced) Audio output sockets

(3-pin XLR)

Page 18: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 18

Audio Media Interface LBB3508/00 (Audio outputs Levels)

4 Asymmetrical audio output Nom. Max. . Interpreter floor & language -10 dBV - 10 dBV Multiple floor and line output -19 dBV +11 dBV Delegate loudspeaker channel -10 dBV + 2 dBV

4 Symmetrical Audio output Nom. Max. . Interpreter floor & language +1 dBV + 1 dBV Multiple floor and line output - 8 dBV +22 dBV Delegate loudspeaker channel +1 dBV +13 dBV

Page 19: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 19

Audio Media Interface LBB3508/00 (Trunk outlet / Tap-off ’s)

1 2 3

Trunk Tap-off 1.Red LED overload indicators

2.Trunk outlet used for loop-through of the trunk-line-cable

3.Tap-off outlets are used for trunk-cable splitting

Page 20: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 20

Audio Media Interface LBB3508/00 (Audio outputs)

Trunk outlet

For loop-through of the DCN trunk-line without regenerating the digital signal.Power handling capacity maximum: - 60 PCF per outlet- 90 PCF total for the three outlets of the AMI.

Tap- offs

For Trunk-cable splitting with regenerating the digital signal.Power handling capacity maximum- 60 PCF per outlet- 90 PCF total for the three outlets of the AMI.

PCF = 90 max.

PCF = 60 max.

Page 21: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 21

1. Mains socket with built-in fuse

Nominal

Mains voltage Mains fuse Power Consumption

220, 230, 240 V AC. T- 2A (slow blow) 175 W

105, 115 V, 125 V AC. T- 4A (slow blow)

Warning:

All units must be powered via an earthed mains outlet.

11

115V-T4A/230V-T2A

Audio Media Interface LBB3508/00

I&O Manual

Page 22: Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO CCE 01.Nov.06 Central Control Equipment LBB3500/05 LBB4106/x0 LBB3508/00.

Security Systems BU Communication Systems

DCN SA PO CCE01.Nov.06 ST/SEU-CO 22

Central Control Equipment

End of section