SECTION 2 - OPERATION
Transcript of SECTION 2 - OPERATION
ATC-5000NG
ATC/DME Test Set
Getting Started Manual
EXPORT CONTROL WARNING: This document contains controlled technical data under the jurisdiction of the Export Administration Regulations (EAR), 15 CFR 730-774. It cannot be transferred to any foreign third party without the specific prior approval of the U.S. Department of Commerce, Bureau of Industry and Security (BIS). Violations of these regulations are punishable by fine, imprisonment, or both.
Issue-4
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
ATC-5000NG
ATC/DME Test Set
Getting Started Manual
PUBLISHED BY Aerof lex
COPYRIGHT Aerof lex 2017
All r ights reserved. No part of this publ icat ion may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic , mechanical, photocopying, recording or otherwise without the prior permission of the publisher.
Original June 2015 Issue-2 August 2015 Issue-3 March 2016 Issue-4 June 2017
10200 West York / W ichita, Kansas 67215 U.S.A. / (316) 522 -4981 / FAX (316) 529-5330
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
This manual contains essential information relat ing to init ial use of the Unit . Aerof lex recommends the operator become famil iar with the
Operat ion Manual contained on the accompanying CD-ROM.
Aerof lex updates Test Set software on a rout ine basis. As a result , the examples may show images from earl ier software versions. Images are
updated when appropriate.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
1
Product Warranty
Refer to http:/ /ats.aerof lex.com/warranty for the Product Warranty information.
Electromagnetic Compatibil ity
Double shielded and properly terminated external interface cables must be used with this equipment when interfacing with the REMOTE Connector.
For cont inued EMC compliance, al l external cables must be shielded and 3 meters or less in length.
Nomenclature Statement
In this manual, ATC-5000NG, Test Set or Unit refers to the ATC-5000NG ATC/DME Test Set .
Declaration of Conformity
The Declarat ion of Conformity Cert i f icate included with the Unit should remain with the Unit .
Aerof lex recommends the operator reproduce a copy of the Declarat ion of Conformity Cert i f icate to be stored with the Operat ion Manual for future reference.
Software Version
Aerof lex updates Test Set software on a rout ine basis. As a result , examples may show images from earl ier software versions. Images are updated when appropriate.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
2
Precautions
SAFETY FIRST - TO ALL OPERATIONS PERSONNEL
General Conditions of Use
This product is designed and tested to comply with the requirements of IEC/EN61010-1 ‘Safety requirements for electrical equipment for measurement, control and laboratory use’ for Class I portable equipment and is for use in a pollut ion degree 2 environment. The equipment is designed to operate from instal lat ion supply Category I I .
The ATC-5000NG should be protected from l iquids such as spi l ls, leaks, etc. and precipitat ion such as rain, snow, etc. When moving the equipment from a cold to hot environment, al low the temperature of the equipment to stabi l ize before the Unit is connected to an AC power supply to avoid condensation forming. The equipment must only be operated within the environmental condit ions specif ied in the product specif icat ions.
This product is not approved for use in hazardous atmospheres or medical appl icat ions. I f the equipment is to be used in a safety-related applicat ion, such as avionics or mil i tary appl icat ions, the suitabi l i ty of the product must be assessed and approved for use by a competent person. Refer al l servicing of Unit to Quali f ied Technical Personnel.
PROTECTION PROVIDED BY EQUIPMENT
MAY BE IMPAIRED IF THE TEST SET IS
USED IN A MANNER NOT SPECIFIED BY
THE MANUFACTURER.
AVERTISSEMENT LA PROTECTION FOURNIE AVEC
L'EQUIPEMENT PEUT S'AVERER
INEFFICACE EN CAS
D'UTILISATION D'UNE MANIERE
NON SPECIFIEE PAR LE
FABRICANT.
Safety Identification in Technical Manual This manual uses the fol lowing terms to draw attent ion to possible safety hazards that may exist when operat ing or servicing this equipment:
IDENTIFIES CONDITIONS OR ACTIVITIES THAT, IF IGNORED, CAN RESULT IN EQUIPMENT OR PROPERTY DAMAGE, E.G. FIRE.
IDENTIFIES CONDITIONS OR ACTIVITIES
THAT, IF IGNORED, CAN RESULT IN
PERSONAL INJURY OR DEATH.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
3
Safety Symbols in Manuals and on Units
CAUTION : Refer to accompanying documents. (Symbol refers to specif ic CAUTIONS represented on the Unit and clari f ied in the text.)
Indicates a Toxic hazard.
Indicates i tem is stat ic sensit ive.
AC TERMINAL: Terminal that may supply or be supplied with AC or alternat ing voltage.
Indicates a fuse (AC or DC).
HOT SURFACE: This surface may be hot to the touch.
Case, Cover or Panel Removal
Opening the Case Assembly exposes the operator to electrical hazards that may result in electrical shock or equipment damage. Do not operate this Test Set with the Case Assembly open.
AVERTISSEMENT | ATTENTION
L'ouverture de l 'enceinte expose l 'opérateur à des dangers électriques pouvant être à l 'origine d'un choc ou de l 'endommagement de l 'équipement. Ne faites pas fonct ionner ce Test Set avec son enceinte ouverte.
Equipment Grounding Protection
Improper grounding of equipment can result in electrical shock.
AVERTISSEMENT | ATTENTION
Une masse défectueuse de l 'équipement peut être à l 'origine d'un choc électrique.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
4
Case, Cover or Panel Removal
Opening the Case Assembly exposes the operator to electrical hazards that may result in electrical shock or equipment damage. Do not operate this Test Set with the Case Assembly open.
AVERTISSEMENT | ATTENTION
L'ouverture de l 'enceinte expose l 'opérateur à des dangers électriques pouvant être à l 'origine d'un choc ou de l 'endommagement de l 'équipement. Ne faites pas fonct ionner ce Test Set avec son enceinte ouverte.
Equipment Grounding Protection
Improper grounding of equipment can result in electrical shock.
AVERTISSEMENT | ATTENTION
Une masse défectueuse de l 'équipement peut être à l 'origine d'un choc électrique.
Use of Probes
To prevent electrical shock or damage to equipment: Verify that al l the connect ions between the equipmen t and a device under test do not exceed maximum port rat ings for voltage, current and power.
AVERTISSEMENT | ATTENTION
Pour éviter tout choc électrique ou D’endommageR l 'équipement:Vérif iez que toutes les interconnexions entre l 'équipement et un périphér ique testé ne dépassent pas les valeurs maximales pour la tension, le courant et la puissance DE CHAQUE PORT.
DMM Measurement Category
The Digital Mult imeter (DMM) is classif ied in Measurement Category I I . Measurement Category I I is designated for equipment which performs measurements on circuits direct ly connected to low voltage instal lat ion.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
5
Power Cords The AC Power Cord included with the Test Set , or an appropriate replacement, should be used to connect the Test Set to a grounded AC power supply. Fai l ure to ground the Test Set may expose the operator to hazardous voltage levels.
To connect the Test Set to a Class I I (ungrounded) 2-terminal socket out let, f i t the power cord with either a 3-pin Class I plug used in conjunct ion with an adapter incorporat ing a ground wire or f i t the power cord with a Class I I plug containing an integral ground wire. The ground wire must be securely fastened to ground; grounding one terminal on a 2-terminal socket does not provide adequate protect ion.
Power cords must be in good operat ing condit ion. Power cords must not be frayed or broken, nor expose bare wiring. Using a damaged power cord may expose the operator to hazardous voltage levels.
International Power Requirements
The AC power cord must meet local regulat ions and power requirements. Check with local standards and regulat ions to ensure the power cord being used meets al l local safety regulat ions.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
6
EMI (Electromagnetic Interference)
SIGNAL GENERATORS CAN BE A SOURCE OF ELECTROMAGNETIC INTERFERENCE (EMI) TO COMMUNICATION RECEIVERS. SOME TRANSMITTED SIGNALS CAN CAUSE DISRUPTION AND INTERFERENCE TO COMMUNICATION SERVICE OUT TO A DISTANCE OF SEVERAL MILES. USER OF THIS EQUIPMENT SHOULD SCRUTINIZE ANY OPERATION THAT RESULTS IN RADIATION OF A SIGNAL (DIRECTLY OR INDIRECTLY) AND SHOULD TAKE NECESSARY PRECAUTIONS TO AVOID POTENTIAL COMMUNICATION INTERFERENCE PROBLEMS.
ATTENTION LES GENERATEURS DE SIGNAUX PEUVENT CONSTITUER UNE SOURCE D'INTERFERENCES ELECTROMAGNETIQUES ( IME) POUR LES RECEPTEURS RADIO. CERTAINS SIGNAUX EMIS PEUVENT PROVOQUER DES INTERFERENCES ET DES INTERRUPTIONS DES COMMUNICATIONS SUR UNE DISTANCE DE PLUSIEURS KILOMETRES. L'UTILISATEUR DE CET EQUIPEMENT DOIT EXAMINER SOIGNEUSEMENT TOUT FONCTIONNEMENT PROVOQUANT LE RAYONNEMENT D'UN SIGNAL (DIRECT OU INDIRECT) ET IL DOIT PRENDRE LES DISPOSITIONS NECESSAIRES AFIN D'EVITER DES PROBLEMES POTENTIELS D'INTERFERENCES SUR LES COMMUNICATIONS.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
7
Input Overload
REFER TO PRODUCT SPECIFICATIONS FOR MAXIMUM INPUT RATINGS FOR INPUT CONNECTORS.
ATTENTION REPORTEZ-VOUS AUX SPECIFICATIONS DU PRODUIT POUR LES CLASSIFICATIONS D'ENTREE MAXIMUM SUR LES CONNECTEURS D'ENTREE.
Toxic Hazards
SOME OF THE COMPONENTS USED IN
THIS EQUIPMENT MAY INCLUDE RESINS
AND OTHER MATERIALS WHICH GIVE OFF
TOXIC FUMES IF INCINERATED. TAKE
APPROPRIATE PRECAUTIONS IN THE
DISPOSAL OF THESE ITEMS.
AVERTISSEMENT CERTAINS DES COMPOSANTS
UTILISES DANS CET
EQUIPEMENT PEUVENT
CONTENIR DES RESINES ET
D'AUTRES MATERIAUX QUI
PRODUIRONT DES EMANATIONS
TOXIQUES EN CAS
D'INCINERATION. PRENEZ
TOUTES LES DISPOSITIONS
NECESSAIRES LORS DE LA MISE
AU REBUT DE CES
EQUIPEMENTS.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
8
Toxic Hazards (cont)
BERYLLIA
BERYLLIA (BERYLLIUM OXIDE) IS USED IN
THE CONSTRUCTION OF SOME OF THE
COMPONENTS IN THIS EQUIPMENT.
THIS MATERIAL, WHEN IN THE FORM OF
FINE DUST OR VAPOR AND INHALED INTO
THE LUNGS, CAN CAUSE A RESPIRATORY
DISEASE. IN ITS SOLID FORM, AS USED
HERE, IT CAN BE HANDLED SAFELY,
HOWEVER, AVOID HANDLING CONDITIONS
WHICH PROMOTE DUST FORMATION BY
SURFACE ABRASION.
USE CARE WHEN REMOVING AND
DISPOSING OF THESE COMPONENTS. DO
NOT PUT THE COMPONENTS IN THE
GENERAL INDUSTRIAL OR DOMESTIC
WASTE OR DISPATCH BY POST. THE
COMPONENTS SHOULD BE SEPARATELY
AND SECURELY PACKED AND CLEARLY
IDENTIFIED TO SHOW THE NATURE OF
THE HAZARD AND THEN DISPOSED OF IN
A SAFE MANNER BY AN AUTHORIZED
TOXIC WASTE CONTRACTOR.
OXYDE DE BERYLLIUM
AVERTISSEMENT DU BERYLLIUM (OXYDE DE
BERYLLIUM) EST UTILISE DANS
LA FABRICATION DE CERTAINS
DES COMPOSANTS DE CET
EQUIPEMENT.
CE MATERIAU PEUT
PROVOQUER UNE AFFECTION
DES VOIES RESPIRATOIRES
LORSQU'IL SE PRESENTE SOUS
LA FORME D'UNE POUSSIERE
FINE OU DE VAPEUR ET QU'IL
ATTEINT LES POUMONS. SOUS
SA FORME SOLIDE, TEL QU'IL
EST UTILISE ICI, IL PEUT ETRE
MANIPULE SANS DANGER, MAIS
IL EST PREFERABLE D'EVITER
TOUTE FORME DE
MANIPULATION POUVANT
AMENER LA FORMATION DE
POUSSIERES PAR ABRASION
DES SURFACES.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
9
Toxic Hazards (cont)
OXYDE DE BERYLLIUM
AVERTISSEMENT SOYEZ PRUDENT LORS DE LA
DEPOSE ET DE LA MISE AU
REBUT DE CES COMPOSANTS.
NE LES TRAITEZ PAS EN TANT
QUE DECHETS INDUSTRIELS OU
MENAGERS HABITUELS; NE LES
INTRODUISEZ PAS DANS LE
CIRCUIT POSTAL. ILS DOIVENT
ETRE EMBALLES SEPAREMENT
ET SOLIDEMENT, ET
CLAIREMENT IDENTIFIES AFIN
DE PRESENTER LA NATURE DU
DANGER ET D'ETRE ENSUITE
MIS AU REBUT SANS DANGER
PAR UNE ENTREPRISE
AUTORISEE DE TRAITEMENT
DES DECHETS TOXIQUES.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
10
Toxic Hazards (cont)
BERYLLIUM COPPER
SOME MECHANICAL COMPONENTS WITHIN
THIS INSTRUMENT ARE MANUFACTURED
FROM BERYLLIUM COPPER. THIS IS AN
ALLOY WITH A BERYLLIUM CONTENT OF
APPROXIMATELY 5% THAT REPRESENTS
NO RISK IN NORMAL USE.
THIS MATERIAL SHOULD NOT BE
MACHINED, WELDED OR SUBJECTED TO
ANY PROCESS WHERE HEAT IS
INVOLVED.
THIS MATERIAL MUST BE DISPOSED OF
AS “SPECIAL WASTE.”
THIS MATERIAL MUST NOT BE DISPOSED
OF BY INCINERATION.
CUPROBERYLLIUM
AVERTISSEMENT CERTAINS COMPOSANTS
MECANIQUES A L'INTERIEUR DE
CET INSTRUMENT SONT
FABRIQUES AVEC DU
CUPROBERYLLIUM. IL S 'AGIT
D'UN ALLIAGE CONTENANT
ENVIRON 5 % DE BERYLLIUM. IL
NE PRESENTE AUCUN RISQUE
DANS LE CADRE D'UNE
UTILISATION NORMALE.
CE MATERIAU NE DOIT PAS
ETRE USINE, SOUDE OU SOUMIS
A AUCUN PROCESSUS
IMPLIQUANT DE LA CHALEUR.
IL DOIT ETRE MIS AU REBUT EN
TANT QUE « DECHET SPECIAL ».
IL NE DOIT PAS ÊTRE MIS AU
REBUT PAR INCINERATION.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
11
Static Sensitive Components
CAUTION
THIS EQUIPMENT CONTAINS PARTS
SENSITIVE TO DAMAGE
BY ELECTROSTATIC DISCHARGE (ESD)
This equipment contains components sensi t ive to damage by Electrostat ic Discharge (ESD). Al l personnel performing maintenance or cal ibrat ion procedures should have knowledge of accepted ESD pract ices and/or be ESD cert i f ied.
Table of Contents
Service Upon Receipt of Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Unpacking.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Checking Unpacked Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Specif icat ions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Instal lat ion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Complying with Instruct ions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
AC Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Venti lat ion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Grounding Power Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Operat ing Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Instal lat ion Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Bench Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Rack Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
External Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Controls, Connectors and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Power On/Off Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Power ON Test Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Power OFF Test Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Touch Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Screen Features and Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Menus and Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
12
1.0 SERVICE UPON RECEIPT OF MATERIAL
1.1 Unpacking
Special-design packing material inside the shipping container provides maximum protect ion for the ATC-5000NG. Avoid damaging the shipping container and packing material during equipment unpacking.
Use the fol lowing steps to unpack the Test Set:
STEP PROCEDURE
1. Cut and remove the seal ing tape on top of the shipping container and open the shipping container.
2. Remove the top packing mold.
3. Remove ATC-5000NG and packing material f rom the bottom packing mold.
4. Remove the protect ive p last ic bag from the ATC-5000NG and inspect the contents.
5. Place the protect ive plast ic bag and packing material inside the shipping container.
6. Store the shipping container for future use should the ATC-5000NG need to be returned/shipped.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
13
1.2 Checking Unpacked Equipment
Check the equipment for damage incurred during shipment. I f the equipment has been damaged or i f i tems seem to be absent from the shipment, report the damage and/or discrepancies to Aerof lex Customer Service.
Contact:
Aeroflex
Attn: Customer Service
10200 West York Street
W ichita, Kansas 67215
Telephone: (800) 835-2350 (U.S. only)
(316) 522-4981
FAX: (316) 529-5330
email : [email protected]
Standard Items
DESCRIPTION PART
NUMBER
QTY
ATC-5000NG 138156 1
Manual, Gett ing Started (Paper) 139189 1
Manual, Operat ion (CD) 139188 1
Power Cable (AC) (110 Use) (US Only)
62302 1
Power Cables (AC) (220 Use) (Europe)
64020 1
Touchpad 114114 1
Refer to the ATC-5000NG Operat ion Manual for Optional I tems avai lable for the ATC-5000NG ATC/DME Test Set .
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Expor t Control, see Cover Page for detai ls.
14
ATC-5000NG Manual, Getting Started
(Paper)
Manual, Operation
(CD)
Power Cable (AC)
(110 Use) (US Only)
138156 139189 139188 62302
Operation / ICW Manual
(61105 (1002-6200-2C0)
Power Cable ( AC ) ( North America )
( 27478 )
Power Cables (AC)
(220 Use) (Europe)
Touchpad
64020 114114
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
15
2.0 SPECIFICATIONS
ENVIRONMENTAL / PHYSICAL
Overall Dimensions 10.5 in (H) X 19 in (W) X 24 in (D) (26.7 cm, 48.3 cm, 60.9 cm)
Weight 41 lbs. (19 kg)
AC INPUT POWER
Voltage Range 100 to 240 VAC, 50 to 60 Hz
Usage Environment Indoor Use
Operating Temperature
0C to +40C
23C (5C) Ful l Specif ied Performance
Storage Temperature
0C to +71C
Relative Humidity 0% to 95% non-condensing
Degree of Protection IPX-0
(Specifications are subject to change without notice.)
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
16
3.0 INSTALLATION
3.1 Safety Precautions
The fol lowing safety precautions must be observed during instal lat ion and operat ion. Aerof lex assumes no l iabi l i ty for fai lure to comply with any safety precaution out l ined in this manual.
3.1.A Complying with Instructions
Instal lat ion/operat ing personnel should not attempt to instal l or operate the Test Set without reading and complying with instruct ions contained in this manual. Al l procedures contained in this manual must be performed in exact sequence and manner described.
3.1.B AC Power Requirements
The ATC-5000NG power supply operates over a voltage range of 100 to 120 VAC at 60 Hz or 220 to 240 VAC at 50 Hz.
3.1.C Ventilation
The RGS-2000NG is air-cooled by fans that draw air through vents in the case. Do not onstruct the air vents while the instrument is in use. Avoid standing the instrument on or close to other equipment that is hot .
3.1.D Grounding Power Cord
Use a 3-prong AC Power Cord to connect the Test Set to a grounded AC Power Supply.
DO NOT USE A THREE-PRONG TO TWO-
PRONG ADAPTER PLUG. DOING SO
CREATES A SHOCK HAZARD BETWEEN
THE CHASSIS AND ELECTRICAL GROUND.
AVERTISSEMENT N’UTILISEZ PAS D’ADAPTATEUR
À TROIS BROCHES SUR UNE
PRISE À DEUX BROCHES.
L'INOBSERVATION DE CETTE
CONSIGNE PEUT CRÉER UN
DANGER DE CHOC ENTRE LE
CHÂSSIS ET LA MASSE
ÉLECTRIQUE.
For AC operat ion, the AC Line Cable, connected to the External DC Power Supply, is equipped with a standard three-prong plug and must be connected to a properly grounded three-prong receptacle.
I t is the customer's responsibi l i ty to:
Have a qual i f ied electric ian check receptacle(s) for proper grounding.
Replace any standard two-prong receptacle(s) with properly grounded three-prong receptacle(s).
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
17
3.1.E Operating Safety
DUE TO POTENTIAL FOR ELECTRICAL
SHOCK WITHIN THE TEST SET, THE CASE
ASSEMBLY MUST BE CLOSED WHEN THE
TEST SET IS CONNECTED TO AN
EXTERNAL POWER SOURCE.
AVERTISSEMENT L'ENCEINTE DU TEST SET DOIT
ETRE FERMEE EN RAISON DE
CHOCS ELECTRIQUES
POSSIBLES LORSQUE
L'APPAREIL EST CONNECTE A
UNE SOURCE D'ALIMENTATION
EXTERNE.
Extreme care should be exercised when performing any operat ions preceded by a CAUTION or WARNING label. CAUTION labels appear where possibi l i ty of damage to equipment exists and WARNING labels denote condit ions where bodily injury or death may result .
3.2 Installation Procedure
3.2.A Bench Use
STEP PROCEDURE
1. Set the ATC-5000NG into operat ing posit ion.
2. Connect the AC Power Cable from the AC INPUT Connector to an external AC power source (100 to 240 VAC at 60 to 50 Hz).
The AC Power Cable is used to ful ly disconnect the Test Set from AC Power. The Test Set should not be posit ioned so the disconnect ion of the AC Power Cable is prevented.
3. Set the Power Switch (on the Test Set Rear Panel) to the ON posit ion (I).
4. Press the Power Switch (on the Test Set Front Panel). The Power Switch Indicator l ights and the Test Set starts the power-up sequence.
3.2.B Rack Mount
Contact Aerof lex for information on instal l ing the ATC-5000NG in a rack.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
18
4.0 EXTERNAL CLEANING
This sect ion contains rout ine instruct ions for c leaning the outside of the Test Set.
DISCONNECT POWER FROM TEST SET TO AVOID POSSIBLE DAMAGE TO ELECTRONIC CIRCUITS.
ATTENTION DEBRANCHEZ L'ALIMENTATION DU TEST SET AFIN D'EVITER D'ENDOMMAGER LES CIRCUITS ELECTRIQUES.
Clean front panel buttons with soft l int -free cloth. I f
dirt is dif f icult to remove, dampen cloth with water and a mild l iquid detergent.
Clean Front Panel display with soft l int -free cloth dampened (not soaked) with non-ammonia based glass cleaner.
Remove grease, fungus and ground-in dirt f rom surfaces with soft l int -free cloth dampened (not soaked) with isopropyl alcohol.
Remove dust and dirt f rom connectors with soft -brist led brush.
Cover connectors, not in use, wi th suitable dust cover to prevent tarnishing of connector contacts.
Clean cables with soft l int -free cloth.
Paint exposed metal surface to avoid corrosion.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
19
5.0 CONTROLS, CONNECTORS AND
INDICATORS
5.1 Front Panel Controls, Connectors and
Indicators
Refer to Numerical Reference Charts for connector cross -reference. Controls, Connectors and Indicators are l isted by numerical reference.
# Name Description
1 Color LCD
Touch Screen
Used to interact with the Test Set menus.
2 Power Switch /
Indicator
Used for turning the Test Set ON and OFF. Indicator is l i t when the Test Set is ON.
3 USB Connectors Type A Connectors used for interface to external USB devices (keypad, mouse, f lash drive, etc.) .
Type B Connector used for remote control of the Test Set.
4 LAN Connector Used for remote control of the Test Set via TCP/IP.
5 SUPP Connector Used for test ing of the UUT (suppressor output) .
6 SCOPE
Connectors
Used for test ing of the UUT.
7 RF I/O
Connectors
(TOP, BOTTOM)
Used for test ing of the UUT.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
20
5.2 Rear Panel Connectors
Refer to Numerical Reference Charts for connector cross -reference. Connectors are l isted by numerical reference.
# Name Description
1 LAN Connector Used for remote control of the Test Set via TCP/IP.
2 AUX CONTROL
Connector
Future Use
3 SA TOP
Connector
Used for coupled output from the Top Receiver (Spectrum Analyzer).
4 SA BOTTOM
Connector
Used for coupled output from the Bottom Receiver (Spectrum Analyzer).
5 EXTERNAL
PULSE
MODULATION
Connectors
Used for I /O applicat ions with external equipment.
6 SCOPE
Connectors
Used for test ing of the UUT.
7 SUPP Connector Used for test ing of the UUT (suppressor output).
8 ATE Line
Connector
Used for connect ion to external equipment. The connector contains discrete inputs, discrete outputs and 429 Tx/Rx.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
21
5.2 Rear Panel Connectors (cont)
# Name Description
9 GPIB Bus
Connector
24-pin female connector conforming to IEEE standard 488-1978 for interface of general purpose programmable instrumentat ion.
10 Power
Connector
Standard 3-prong power receptacle for connect ion to AC power source (100 to 240 VAC, 50 to 60 Hz).
11 Power Switch Connects (I) or disconnects (O) external AC power from the ATC-5000NG.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
22
6.0 POWER ON/OFF PROCEDURES
6.1 Power ON Test Set
STEP PROCEDURE
1. Press the Power Switch (Front Panel) to power ON the Test Set.
2. Verify the Power Switch Indicator i l luminates.
3. Wait while the Test Set completes the power-up sequence.
The ATC-5000NG Main Menu is displayed.
6.2 Power OFF Test Set
STEP PROCEDURE
1. Press the Power Switch (Front Panel) to power OFF the Test Set.
2. Verify the Power Switch Indicator is not i l luminated.
(Th is scr een is a r epr esenta t ion o f the scr een tha t appear s . )
(Opt iona l Funct ions a r e shown for d isp lay pur poses on ly . )
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
23
7.0 TOUCH SCREEN
The ATC-5000NG contains a resist ive Touch Screen that is responsive to the touch of a human f inger. Gloves can be worn when ut i l izing the Touch Screen or a writ ing instrument (e.g. stylus) can be used on the Touch Screen.
8.0 SCREEN FEATURES AND ICONS
Screen Icons
Screen Features
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
24
8.0 SCREEN FEATURES AND ICONS (cont)
Icon Description
External equipment is connected to the LAN Connector (Front or Rear Panel) .
External equipment is not connected to the LAN Connector (Front or Rear Panel).
External equipment is connected to the USB Connector.
External equipment is not connected to the USB Connector.
External equipment is connected to the GPIB Connector.
External equipment is not connected to the GPIB Connector.
The conf igurat ion does not match with the subassemblies present in the system or a DSP or FPGA f irmware version is incorrect.
Icon Description
An error has occurred. Place the mouse cursor over the icon to see a descript ion of the error or double cl ick on the icon to go to the Error Menu to see a l ist of errors.
Press this icon to open safely remove hardware dialog.
Opens the on-screen keyboard for data entry.
Press this icon to open Windows Explorer.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
25
8.0 SCREEN FEATURES AND ICONS (cont)
Feature Description
Local Mode - Al l controls on the Touchscreen are enabled.
Remote Mode - Al l controls on the touchscreen are disabled.
Softkeys are used to display a menu, funct ion screen or access a menu f ield.
A green arrow to the right on the Softkeydisplays addit ional Softkeys.
When green, press the arrow to display addit ional Softkeys.
Inact ive when gray.
When green, press the arrow to display addit ional Softkeys.
Inact ive when gray.
Touchscreen Mode - Press a control to display a numeric keypad, keyboard or l istbox for select ion or entry of the parameter.
Feature Description
Normal Mode - Controls are modif ied using an external mouse or keypad.
When green, the previous menu is displayed.
Inact ive when gray.
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
26
9.0 MENUS AND SCREENS
Main Menu
(Th is scr een is a r epr esenta t ion o f the scr een tha t appear s . )
(Opt iona l Funct ions a r e shown for d isp lay pur poses on ly . )
Multi-Receiver Menu
(Th is scr een is a r epr esenta t ion o f the scr een tha t appear s . )
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
27
9.0 MENUS AND SCREENS (cont)
Transponder Menu
(Th is scr een is a r epr esenta t ion o f the scr een tha t appear s . )
DME Menu
(Th is scr een is a r epr esenta t ion o f the scr een tha t appear s . )
(The DME Menu is an Opt iona l F unct ion in the ATC -5000NG . )
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
28
9.0 MENUS AND SCREENS (cont)
UAT Menu
(Th is scr een is a r epr esenta t ion o f the scr een tha t appear s . )
(The UAT Menu is an Opt iona l Funct ion in the ATC -5000NG . )
System Menu
(Th is scr een is a r epr esenta t ion o f t he scr een tha t appear s . )
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
29
9.0 MENUS AND SCREENS (cont)
Support Menu
(Th is scr een is a r epr esenta t ion o f the scr een tha t appear s . )
ATC -5000NG Get t ing S ta r ted M anua l
Subject to Export Control, see Cover Page for detai ls.
30
THIS PAGE INTENTIONALLY LEFT BLANK.
Our passion for performance is defined by threeattributes represented by these three icons:
solution-minded, performance-driven, customer-focused.
As we are always seeking to improve our products, the information in
this document gives only a general indication of the product capacity,
performance and suitability, none of which shall form part of any
contract. We reserve the right to make design changes without notice.
EXPORT CONTROL WARNING: This document contains controlled technicaldata under the jurisdiction of the Export Administration Regulations (EAR), 15 CFR 730-774. It cannot be transferred to any foreign third party withoutthe specific prior approval of the U.S. Department of Commerce, Bureau ofIndustry and Security (BIS). Violations of these regulations are punishable by fine, imprisonment, or both.
*139189*139189 D0
DIR: 10000040378 DA
Go to http://ats.aeroflex.com/contact/sales-distribution for Sales and Service contact information.