Sect-Swale...4444 W 78th St, Minneapolis, MN 55435 RKM CDM 12-19-17 2 of12 952-897-1040 18" 13.5" 4"...
Transcript of Sect-Swale...4444 W 78th St, Minneapolis, MN 55435 RKM CDM 12-19-17 2 of12 952-897-1040 18" 13.5" 4"...
12.5"
17.88"
12.5" 12"
18.63"
12"
12.44" 12"
17.88"
8"8"
8"
18"
12.06" 12"
8"
Title:
The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.
Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Regal Stone Pro Details 8" Single Unit Details
Revision: Date: Drawing No:Designed By: Checked By:
No Scale
Scale:
Straight Face Unit
12"
8"
1"
Typical Section
1 ofCDMRKM
Dimensions May Vary by Region*
Rock Face Unit
12-19-17 124444 W 78th St, Minneapolis, MN 55435
952-897-1040
17.25"
11" 10"4"
Title:
The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.
Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Regal Stone Pro Details Cap Unit Details
Revision: Date: Drawing No:Designed By: Checked By:
No Scale
Scale:
Cap Units Inside Curve Cap Units Corner / Wall
Cap Units Wall Step PlanCap Units Wall Step
Isometric
Cap Unit
Cap Units Outside Curve
Split Cap End
Split Cap Both Ends
Split Cap End
Cut Cap Unit as Required at End of Wall
Cut Cap Units as Requiredto Construct a Mitered 90 Degree Corner
Cut Cap Units to Fitas Required
Cut Cap Units to Fitas Required
2 ofCDMRKM 1212-19-174444 W 78th St, Minneapolis, MN 55435
952-897-1040
18"
13.5"
4"
Title:
The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.
Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Regal Stone Pro Details Rectangular Cap Unit Details
Revision: Date: Drawing No:Designed By: Checked By:
No Scale
Scale:
Cap Units Inside Curve Cap Units Corner / Wall
Cap Units Wall Step PlanCap Units Wall StepIsometric
Cap Unit
Cap Units Outside Curve
Cut Cap Unit as Required at End of Wall
Cut Cap Units as Requiredto Construct a Mitered 90 Degree Corner
Cut Cap Units to Fitas Required
Cut Cap Units to Fitas Required
3 ofCDMRKM 12
Double Cap at Step
12-19-174444 W 78th St, Minneapolis, MN 55435
952-897-1040
Title:
The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.
Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Regal Stone Pro Details Gravity Wall Details
Revision: Date: Drawing No:Designed By: Checked By:
No Scale
Scale:
Gravity Wall Typical Section
Cap Unit
Regal Stone Pro Unit
FinishedGrade
Total WallHeight
Embedment
24"
6"
12" (Min.) of FreeDraining Aggregate
4" Ø (Min) Drain Tile(Elevation Varies)(See Note)
4" Ø (Min) Drain Tile(Elevation Varies) - or -
6" (Min) CompactedGranular Base Leveling Pad
Note:Drain should be at bottom of wall whenpossible.Utilize raised drain location when bottomof wall drainage is not possible.
Low Permeable Soil
1"
8"
4 ofCDMRKM 1212-19-174444 W 78th St, Minneapolis, MN 55435
952-897-1040
Title:
The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.
Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Regal Stone Pro Details Reinforced Wall Details
Revision: Date: Drawing No:Designed By: Checked By:
No Scale
Scale:
Cap Unit
Regal Stone Pro Unit
FinishedGrade
Total WallHeight
Embedment
24"
6"
4" Ø (Min) Drain Tile(Elevation Varies)
4" Ø (Min) Drain Tile(Elevation Varies) - or -
6" (Min) CompactedGranular Base Leveling Pad
12" (Min.) of FreeDraining Aggregate
GeosyntheticReinforcement(Typ)
Reinforced Soil
Note:Drain should be at bottom of wall whenpossible.Utilize raised drain location when bottomof wall drainage is not possible.
Typical Reinforced Wall Section
Low Permeable Soil
1"
8"
5 ofCDMRKM 1212-19-174444 W 78th St, Minneapolis, MN 55435
952-897-1040
Title:
The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.
Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Regal Stone Pro Details Tiered Wall Details
Revision: Date: Drawing No:Designed By: Checked By:
No Scale
Scale:
Regal Stone Pro Unit
Finished Grade
24"
6" 6" (Min) CompactedGranular BaseLeveling Pad
12" (Min.) of FreeDraining AggregateGeosynthetic
Reinforcement(Typ)
Reinforced Soil
Varies
Cap Unit
Total TierHeight
Embedment
Embedment
Typical Tiered Section
Rear Drain SytemWhen Required
1"
8"
1"
8"
6 ofCDMRKM 12
4" Ø (Min) Drain Tile(Elevation Varies)
4" Ø (Min) Drain Tile(Elevation Varies) - or -
Note:Drain should be at bottom of wall whenpossible.Utilize raised drain location when bottomof wall drainage is not possible.
12-19-174444 W 78th St, Minneapolis, MN 55435
952-897-1040
Title:
The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.
Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Regal Stone Pro Details Inside Corner Details
Revision: Date: Drawing No:Designed By: Checked By:
No Scale
Scale:
Typical Base and / or OddNumbered Courses Plan
Inside Corner Isometric
Typical 2nd and / or EvenNumbered Courses Plan
Inside Corner Plan with Geogrid
Block Note:Cut units as required to maintain running bond pattern.
Grid
Str
engt
h Di
rect
ion
Grid Strength Direction
Free DrainingAggregate
Cut Unit
Additional Geogrid OverlapExtension (See Note)
H/4
H/4
Geogrid Note:Measure, cut and orient the geogrid, as per the engineers design andthe geogrid manufacturers specifications on correct strength direction.
Extend geogrid the wall height / 4 (H / 4) beyond the adjoining wallface at inside wall corners.
The reinforcement should not extend into the retaining wall units onthe perpendicular leg of the 90 degree corner.
Geogrid Reinforcement(Typ.)
3" of Backfill is RequiredBetween Overlapping Geogridfor Proper Anchorage (Typ.).
7 ofCDMRKM 12
Free DrainingAggregate
Cut Unit
12-19-174444 W 78th St, Minneapolis, MN 55435
952-897-1040
Title:
The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.
Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Regal Stone Pro Details Outside Corner Details
Revision: Date: Drawing No:Designed By: Checked By:
No Scale
Scale:
Typical Base and / or OddNumbered Courses Plan
Outside Corner Isometric
Typical 2nd and / or EvenNumbered Courses Plan
Outside Corner Plan with Geogrid
Block Note:Cut units as required to maintain runningbond pattern.
Free DrainingAggregate
Corner Unit
Geogrid Reinforcement(Typ.)
3" of Backfill is RequiredBetween Overlapping Geogridfor Proper Anchorage (Typ.).
Corner Unit
H/2
H/2
H/2
H/2
Wall Corner AdditionalFree DrainingAggregate Fill Limits(See Notes)
Free DrainingAggregate
Wall Corner AdditionalFree DrainingAggregate Fill Limits(See Notes)
Geogrid Note:Measure, cut and orient the geogrid, as per theengineers design and the geogrid manufacturersspecifications on correct strength direction.
The reinforcement should not extend into theretaining wall units on the perpendicular leg of the90 degree corner.
Free Draining Aggregate Note:Place additional free draining aggregatefill at outside wall corners to extend backfrom wall face each way a distance equalto the wall height / 2 (H / 2).
8 ofCDMRKM 12
Grid Strength Direction
Grid
Str
engt
h Di
rect
ion
12-19-174444 W 78th St, Minneapolis, MN 55435
952-897-1040
Title:
The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.
Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Regal Stone Pro Details Inside Curve Details
Revision: Date: Drawing No:Designed By: Checked By:
No Scale
Scale:
Typical Inside Curve Plan
Inside Curve IsometricInside Curve Plan with Geogrid
Block Note:Cut units as required to maintain running bond pattern.
Free DrainingAggregate
Regal Stone Pro Unit
Place Additional Pieces of GeogridWhen Gap Angle Exceeds 20° onInside Wall Curves
Geogrid Reinforcement(Typ)
20°
9 ofCDMRKM 12
Grid
Str
engt
h Di
rect
ion
Grid Strength Direction
Geogrid Note:Measure, cut and orient the geogrid, as per theengineers design and the geogrid manufacturersspecifications on correct strength direction.
The reinforcement should not extend into theretaining wall units on the perpendicular leg of the90 degree corner.
12-19-174444 W 78th St, Minneapolis, MN 55435
952-897-1040
Title:
The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.
Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Regal Stone Pro Details Outside Curve Details
Revision: Date: Drawing No:Designed By: Checked By:
No Scale
Scale:
Typical Outside Curve Plan
Outside Curve Isometric
Outside Curve Plan with Geogrid
Block Note:Cut units as required to maintain running bond pattern.
Free DrainingAggregate
Regal Stone Pro Unit
3" of Backfill is RequiredBetween Overlapping Geogridfor Proper Anchorage (Typ.)
H/2
H/2
Geogrid Reinforcement (Typ)
Additional Corner Free DrainingAggregate (See Notes)
10 ofCDMRKM 12
Grid Strength Direction
Grid
Str
engt
h Di
rect
ion
Geogrid Note:Measure, cut and orient the geogrid, as per theengineers design and the geogrid manufacturersspecifications on correct strength direction.
The reinforcement should not extend into theretaining wall units on the perpendicular leg of the90 degree corner.
Free Draining Aggregate Note:Place additional free draining aggregatefill at outside wall corners to extend backfrom wall face each way a distance equalto the wall height / 2 (H / 2).
12-19-174444 W 78th St, Minneapolis, MN 55435
952-897-1040
Title:
The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.
Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Regal Stone Pro Details Top of Wall Fence Details
Revision: Date: Drawing No:Designed By: Checked By:
No Scale
Scale:
Cap Unit
Regal Stone Pro Unit
Finished Grade
18" ±
Minimum Offset Fence Section
Note:Concrete filled tube or form to be set during the wallconstruction, not drilled through geogrid afterwardswhen directly behind units.
Steel Fence or Railing
36" M
in.
Geosynthetic Reinforcement(Typ)
Concrete Filled Tube orForm 8' o.c. Max.
Cap Unit
Regal Stone Pro Unit
FinishedGrade
36"
Steel Fence or Railing
24" M
in.
Geosynthetic Reinforcement(Typ)
Concrete Filled Tube orForm 8' o.c. Max.
Fence Section
11 ofCDMRKM 1212-19-174444 W 78th St, Minneapolis, MN 55435
952-897-1040
Title:
The suitability and/or manner of use of any detailscontained in this document is the sole responsibility of theuser.Final project specific designs shall be prepared by a licensedprofessional engineer.
Copyright 2017 Keystone Retaining Wall Systems, LLC Project:Regal Stone Pro Details Top of Wall Swale Details
Revision: Date: Drawing No:Designed By: Checked By:
No Scale
Scale:
Cap Unit
Regal Stone Pro Unit
Concrete or GrassDrainage Swale toIntercept and DivertSurface Water
Steel Fence or Railingas Required
Geosynthetic Reinforcement(Typ)
Concrete Filled Tube orForm 8' o.c. Max.
Drainage Swale Section
24" M
in.
Low Permeable soil
PlasticMembrane
Expansion Materialw/Concrete
FinishedGrade
36" Min.
8" Min.
12 ofCDMRKM 1212-19-174444 W 78th St, Minneapolis, MN 55435
952-897-1040