Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) •...

54
The world leader in serving science Search for What’s Missing: Unknown Compound Characterization Using LC-MS Kate Comstock Sr. Marketing Specialist, Pharma/Biopharma Marketing

Transcript of Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) •...

Page 1: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

The world leader in serving science

Search for What’s Missing: Unknown Compound Characterization Using LC-MSKate ComstockSr. Marketing Specialist, Pharma/Biopharma Marketing

Page 2: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

2

Small molecule structure analysis encompasses broad applications:Pharmaceutical, metabolomics, food & environmental, clinical, forensic, industrial chemical, etc.

The following are small molecule structure analyses and are crucial for pharma R&D.• Impurity analysis

− Drug substance (API)− Drug product− Genotoxic− Stability studies - degradants

• Met ID− Drug discovery – pre-clinical development – clinical development − In vitro (hepatocytes, microsomes, whole blood, plasma)− In vivo (whole blood, plasma, urine, bile, fecal homogenates)− Radio-labeled (13C, 14C, 3H)

• E&L analysis− Extractables− Leachables

• Natural products & traditional medicines research− Discovery and Identify new medicine

Small Molecule Structure Analysis

Page 3: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

3

• Broad range of chemicals with very diverse structures• ChemSpider has 71 M chemical structures.

• Background Interference• Complex biologic matrices, excipients, and solvent background

• Sample Limitations • Example: ADC drug Met ID, the small molecule “warhead” is only small portion of the drug.

• Unknowns• De Novo structural determination is not trivial!

• Many small molecule structure analyses are highly regulated.• Pharma R&D must follow EPA, FDA, EMEA, countries' regulations and guidelines: compliance and GLP.• Toxicity assessments, clinic trails... to ensure drug efficacy and consumer safety

Small Molecule Structure Analyses are Challenging and Complex

All decisions must be based on solid scientific analysis results.High Quality Data is Vital!

Page 4: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

4

Reference: Mass Spectrometry Identification Categories in USP Chapter <1663>

Data typically available from GC/MS and LC/MS analyses (see A through E below) are used to designate individual extractables identifications in the categories of Confirmed, Confident, or TentativeA. Mass spectrometric fragmentation behaviorB. Confirmation of molecular weightC. Confirmation of elemental compositionD. Mass spectrum matches automated library or literature spectrumE. Mass spectrum and chromatographic retention index match authentic reference compound

Confirmed - A Confirmed identification means that A, B (or C), and D (or E) have been fulfilled. Confident - A Confident identification means that sufficient data to preclude all but the most closely related

structures have been obtained. The combination of D with any of A, B, or C can be used to provide a confident identification

Tentative - A Tentative identification means that data have been obtained that are consistent with a class of molecule only.

Confident Structure ID Requires High Resolution Accurate Mass (HRAM) and MSn Fragments

Page 5: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

5

Small Molecule Structure Identification

The Instrument of Choice: Orbitrap™ Mass Spectrometer

AccurateMass

The Three Pillars for Small Molecule Structure ID

CONFIDENT STRUCTURE ID

Isotopic pattern fidelity

MS/MS & MSn

Spectra

Compound FingerprintElemental Composition

Page 6: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

6

SS_calmix_5e4_1M_stdpress #2 RT: 0.07 AV: 1 NL: 2.82E7T: FTMS + p ESI Full ms [150.0000-2000.0000]

524.2 524.4 524.6 524.8 525.0 525.2 525.4 525.6 525.8 526.0 526.2 526.4m/z

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100R

elat

ive

Abu

ndan

ce

524.2648R=665307

525.2682R=621002

526.2607R=624402

525.8954R=647302524.4520

R=597302524.8989R=624000

526.4311R=477100

The Power of High Resolution MS: Fine Isotope Structure MRFASS_calmix_5e4_1M_stdpress #2 RT: 0.07 AV: 1 NL: 1.25E6T: FTMS + p ESI Full ms [150.0000-2000.0000]

526.24 526.25 526.26 526.27 526.28m/z

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100

Relat

ive A

bund

ance

1.9959

2.0067

2.0045

2.0004

2.00941.9875

A+2

34S

213C

15N 13C

18O

MRFA

Page 7: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

7

Ultra High Resolution for Unknown Impurity ID

524.0 524.5 525.0 525.5 526.0 526.5 527.0 527.5m/z

0

20

40

60

80

100

0

20

40

60

80

100

Rel

ativ

e Ab

unda

nce

0

20

40

60

80

100

524.2074R=327537

525.2107R=329117

524.2074R=624278

525.2108R=627302

524.2074R=999105

525.2108R=998597

526.2032R=997988

527.2066R=998143

526.20 526.21 526.22m/z

526.2032

526.2141

526.2075

526.2115

526.2169526.1999

526.2033

526.2141

526.2117526.2078

526.2171526.2032

526.2142

526.2117526.2078

526.2171526.2015

500-K Res.

1-M Res.

1-M Simulation 18O

34S

2H13C

213C

15N13C

33S13C

Page 8: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

8

Orbitrap MS for Small Molecule Structure Analysis

Page 9: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

9

Thermo Scientific LTQ Orbitrap MS – First Generation Hybrid MS

Since 2005 ASMS introduction, Orbitrap MS has become the gold standard for small molecular structure analysis.

Page 10: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

10

Thermo Scientific Q Exactive MS Family – Quan/Qual Workhorse

Thermo Scientific™ Q Exactive™ Plus MS

Thermo Scientific™ Q Exactive ™ MS

Thermo Scientific™ Q Exactive™ Focus MS

Resolving Power: 140K @ m/z 200Scan Range: 50-6,000Scan Rate: 12 Hz at 17.5KOptional: 280K

Resolving Power: 70K @ m/z 200Scan Range: m/z 50-2,000Scan Rate: 12 Hz at 17.5K

Resolving Power: 140K @ m/z 200Scan Range: 50-6,000Scan Rate: 12 Hz at 17.5K

First bench-top Orbitrap MS High performanceEasy to use, robust Polarity switching <1 secHCD MS2

Thermo Scientific™ Q Exactive™ HF MS

Resolving Power: 240K @ m/z 200Scan Range: 50-6,000Scan rate: 18Hz at 15K

Page 11: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

11

Transforming Small Molecule Identification and Characterization

Thermo Scientific™ Orbitrap ID-X™ Tribrid™ MS – Optimized and dedicated to small molecule structure analysis• High performance

• Very high resolution (500K at m/z 200) and high scan rate (30 Hz OT/40 Hz IT) • MSn, CID/HCD multiple dissociation techniques in a single run, OT/IT parallel detection …

• Ultimate flexibility and capability for data acquisition • Comprehensive, feature-specific filters enable triggering MSn of low abundant components• Predefined method templates for quick start

• Novel data acquisition – AcquireX• Automatic background exclusion, greatly improves efficiency, quality and accuracy of analysis

• Advanced data processing SW suite and database • Thermo Scientific™ Compound Discoverer™ 3.0 software, Thermo Scientific™ Mass Frontier™ 8.0 software, and mzCloud™.

mzCloud is a trademark of HighChem LLC, Slovakia

• Mass Range m/z 50 – 2000 • Mass Accuracy <1ppm internal, <3ppm external• Max. Mass Resolution >500,000• Scan rate 30 Hz OT MS2 /40 Hz IT MS2

• Dissociation HCD, CID• MS/MS and MSn

• Polarity switching on the fly

Page 12: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

12

Schematic for Thermo Scientific Orbitrap ID-X MS – Improved Instrumentation

Ultra High Field Orbitrap Mass AnalyzerAccurate mass measurement and resolves isobaric species

Dual Pressure Linear Ion TrapSensitive MSn mass analysis of HCD and CID fragments

Optional Easy-IC Ion SourceGenerates internal calibrant ion for real-time mass calibration

Ion Routing MultipoleAllows parallel analysisHCD at any fragmentation level

Mass Selection QuadrupoleEfficient and selective precursor ion isolationActive Beam Guide

Prevents neutrals and high velocity clusters from entering mass selecting quadrupole S Lens

Efficiently focuses ions into a tight beam minimizing in-source dissociation of fragile compounds http://planetorbitrap.com

Page 13: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

13

General Workflow for Small Molecule Structure Analysis

Orbitrap ID-X MS

CompoundDiscoverer 3.0

Confident Result

CompoundIdentified. _________. _________. _________. _________

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20Time (min)

0

10

20

30

40

50

60

70

80

90

100

Re

lative

Ab

un

da

nce

9.2

6.18.1

6.1

10.1 12.113.211.010.5 13.8 15.88.4

12.96.58.87.3 10.0 11.53.5 14.47.86.9

Urine-8-12hr-1 #4384 RT: 8.74 AV: 1 NL: 8.12E6F: FTMS + p ESI Full ms [120.0000-1200.0000]

150 200 250 300 350 400 450 500 550 600 650 700 750 800 850m/z

0

10

20

30

40

50

60

70

80

90

100

Re

lative

Ab

un

da

nce

595.3498

310.2016

591.3188596.3531

311.2049267.1746219.0477 597.3562198.1280

High Quality HRAM MS & MSn

Mass Frontier 8.0

Novel Software & Database

AcquireX Data Acquisition

Metabolite ID

Page 14: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

14

Case Study: Metabolite Identification of 5 Drugs in Human Liver Microsomal Incubation

O

ONHNS

OH

OO

O

N2H

AmprenavirC25H35N3O6S(M+H)+ 506.23193Cas# 161814-49-9

O

ONHOH

NHN

NH

O

O

LopinavirC37H48N4O5(M+H)+ 629.36975Cas# 192725-17-0

S

N

ONH

NHNH N

SOOH O

ON

RitonavirC37H48N6O5S2(M+H)+ 721.32004Cas# 155213-67-5

N

NO

NH

N

N

SO O

O

OOH

BosentanC27H29N5O6S(M+H)+ 552.19113Cas# 147536-97-8

N SNH

O

OOH

OO

F

F

F

TipranavirC31H33F3N2O5S(M+H)+ 603.21350Cas# 174484-41-4

Page 15: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

15

Traditional Data Dependent Acquisition of MS/MS Spectra for Drug Metabolites

Pähler and Brink, Drug Discov Today Technol., 2013, 10, e207-213

Targeted Approach Non-targeted Approach

DDA Selection Criteria:• m/z inclusion list based on predicted

metabolites• Isotope pattern• Mass defect

DDA Selection Criteria:• Intensity based (“top N” most intense)• All ion fragmentation

Page 16: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

16

AcquireX – A Novel Data Acquisition Workflow for Drug Impurity & Metabolites ID

AcquireX with Orbitrap ID-X MS – Tackles the Identification Bottleneck Automatically Automatically generates an exclusion list from a control sample.

• Excludes the background ions from triggering MSn

• Intelligent data-dependent acquisition - only triggers the ions of interest that are not present in the control.

Automatically generate an inclusion list of samples for deep scan when needed. High quality MSn data in one run and no repeat injections, no need for user to build

exclusion and inclusion list offline Acquire useful data - better than data-independent acquisition (DIA)

AcquireX greatly improves analysis efficiency, quality, and accuracy!

Page 17: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

17

AcquireX Acquisition Workflow: High Performance and Easy to Use

Predefined Method Templates for Met ID

AcquireX Acquisition Workflow

Page 18: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

18

AcquireX Data Acquisition Workflow and Sequence Setup

Page 19: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

19

Conventional and AcquireX Workflow Comparison: Amprenavir as an Example

4 5 6 7 8 9 10 11RT [min]

0

100

200

300

400

500

600

Inte

nsity

[cou

nts]

(10^

6)

8.8348.8348.8348.8348.8348.8348.8348.8348.8348.8348.8348.8348.8348.8348.8348.8348.8348.8348.8348.8348.8348.8348.8348.8348.8348.8348.8347.6217.6217.6217.6217.6217.6217.6217.6217.6217.6217.6217.6217.6217.6217.6217.6217.6217.6217.6217.6217.6217.6217.6217.6217.6217.6217.621

5.1415.1415.1415.1415.1415.1415.1415.1415.1415.1415.1415.1415.1415.1415.1415.1415.1415.1415.1415.1415.1415.1415.1415.1415.1415.1415.141

6.4466.4466.4466.4466.4466.4466.4466.4466.4466.4466.4466.4466.4466.4466.4466.4466.4466.4466.4466.4466.4466.4466.4466.4466.4466.4466.446

9.3039.3039.3039.3039.3039.3039.3039.3039.3039.3039.3039.3039.3039.3039.3039.3039.3039.3039.3039.3039.3039.3039.3039.3039.3039.3039.303

4 5 6 7 8 9 10 11RT [min]

0

10

20

30

40

50

60

70

80

90

Inte

nsity

[cou

nts]

(10^

6)

5.0225.0225.0225.0225.0225.0225.0225.0225.0225.0225.0225.0225.0225.0225.0225.0225.0225.0225.0225.0225.0225.0225.0225.0225.0225.0225.022

8.2778.2778.2778.2778.2778.2778.2778.2778.2778.2778.2778.2778.2778.2778.2778.2778.2778.2778.2778.2778.2778.2778.2778.2778.2778.2778.277

5.2535.2535.2535.2535.2535.2535.2535.2535.2535.2535.2535.2535.2535.2535.2535.2535.2535.2535.2535.2535.2535.2535.2535.2535.2535.2535.253

9.0179.0179.0179.0179.0179.0179.0179.0179.0179.0179.0179.0179.0179.0179.0179.0179.0179.0179.0179.0179.0179.0179.0179.0179.0179.0179.017

Parent

DDA triggered 8 metabolites

AcquireX triggered 21 metabolites

Page 20: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

20

Data Processing Using Thermo Scientific Compound Discoverer 3.0 (CD 3.0) SoftwareUtilizing unique features of CD 3.0, metabolites both expected and unknown were identified

using pre-made “Expected and Unknown” processing workflow

Find expected through dealkylation & dearylation as well as phase I & phase II biotransformation

Flag & provide score for compounds which has matching MS2 fragments with parent compound

Provide score for detected expected compounds; annotates on MSn spectra by fragment ion search, including transformation mass shifted

XIC traces for analytescontaining user-defined isotopic patterns

Provide score for analytes containing user-defined isotopic patterns

Page 21: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

21

“Generate Expected Compounds” Prediction in CD 3.0

-C5H6O3

parent 506.2320 @9.52min 392.2002 @6.50min

Hydrolysis

Dealkylation and Dearylation followed Phase I, Phase II transformation better prediction for expected compounds

Page 22: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

22

Compound Class for Unexpected Metabolite Identification

m/z 506.2319 m/z 351.2278 m/z 237.1961

Compound Class (parent compound fragments)Facilitate unexpected compounds identification

Page 23: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

23

Fragment Ion Search (FISh) Annotations

101.36971171.11336

176.14333190.01756

201.15109246.14876

149.07094

237.19618

202.15903

245.16487

163.1231

141.1024

188.1432116.1068

218.1538158.0965 217.1698190.0863144.0807 172.0756

147.0804

234.11259C13 H16 N O3 [M-e]+1

200.14343C14 H18 N [M-e]+1

117.06980C9 H9 [M-e]+1164.1069

189.10223C11 H13 N2 O [M-e]+1 207.11284C11 H15 N2 O2 [M-e]+1131.08548C10 H11 [M-e]+1164.07056C9 H10 N O2 [M-e]+1

146.06000C9 H8 N O [M-e]+1

134.09637C9 H12 N [M-e]+1257.0955

146.09636C10 H12 N [M-e]+1

208.09682C11 H14 N O3 [M-e]+1

120.08070C8 H10 N [M-e]+1

129.06979C10 H9 [M-e]+1

4429C6 H6 N O [M-e]+1

124.03922C6 H6 N O2 [M-e]+1(+Oxidation)

172.00624C6 H6 N O3 S [M-e]+1(+Oxidation)

100 120 140 160 180 200 220 240m/z

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

Inte

nsity

[cou

nts]

(10^

6) Amp_1Hr_ID (F5) #2717, RT=9.004 min, MS2, FTMS (+), (HCD, DDF, 522.2267@(20;40;65), +1) Amprenavir + (Oxidation) C25 H35 N3 O7 S, MW: 521.21957, Area: 3910188 FISh Coverage: 54 Matched, 34 Unmatched, 26 Skipped

Amprenavir[ ] +O

[ ] +O

Color coded transformation shifted fragment ion annotations help localize the site of biotransformation.

Page 24: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

24

More Metabolites were Triggered for MSn Using Acquire X than Conventional DDA

RT [min] Molecular Weight Formula Transformations DDA AcquireX

2.29 236.1889 C14H24N2O Sulfonamide hydrolysis + amide hydrolysis Y4.84 407.18788 C20H29N3O4S Amide hydrolysis + oxidation Y5.02 350.22056 C19H30N2O4 Sulfonamide hydrolysis Y Y5.14 364.23621 C20H32N2O4 Sulfonamide hydrolysis + methylation Y5.25 407.18788 C20H29N3O4S Amide hydrolysis + oxidation Y Y6.09 407.18788 C20H29N3O4S Amide hydrolysis + oxidation Y Y6.41 697.24513 C30H43N5O10S2 Oxidation + Cys-Gly-conjugation Y6.50 391.19296 C20H29N3O3S Amide hydrolysis Y Y6.61 519.20392 C25H33N3O7S Oxidation (+O-2H) Y Y6.88 826.28773 C35H50N6O13S2 Oxidation + GSH Conjugation Y7.19 624.22876 C28H40N4O8S2 Cysteine Conjugation Y7.32 521.21957 C25H35N3O7S Oxidation Y Y7.62 405.20861 C21H31N3O3S Amide hydrolysis + methylation Y7.81 681.25674 C31H43N3O12S Glucuronidation y Y7.84 521.21957 C25H35N3O7S Oxidation Y Y8.01 537.21449 C25H35N3O8S Di-oxidation Y8.28 503.20901 C25H33N3O6S Dehydration Y8.37 503.20901 C25H33N3O6S Dehydration Y9.02 521.21957 C25H35N3O7S Oxidation Y9.11 503.20901 C25H33N3O6S Dehydration Y9.52 505.2246 C25H35N3O6S Amprenavir Parent Y Y

10.61 519.24031 C26H37N3O6S Methylation Y

Page 25: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

25

Metabolites Identified from Amprenavir HLM Incubations

H2N

SN

OH

O

O HN O

OO

Amprenavirm/z 506

HNOH H

N O

OO

m/z 351

HNOH

NH2

m/z 237

H2N

SN

OH

O

O NH2

m/z 408 (rt 4.8, 5.3 min)

H2N

SN

OH

O

O NH2

m/z 392

OH

m/z 408 (rt 6.1 min)

H2N

SN

OH

O

O NH2

OH

HNOH H

N O

OO

H3C

m/z 365

H2N

SN

OH

O

O HN O

OO

Gluc

m/z 682

H2N

SN

OH

O

O HN O

OO

H2N

SN

OH

O

O HN O

OO

OH

HO

m/z 522 (rt 7.3, 7.8 min)

m/z 522 (rt 9.0 min)

H2N

SN

OH

O

O HN O

OO

m/z 520

O

H2N

SN

OH

O

O HN O

OO

-2H

m/z 504 (rt 8.3, 8.4 min)

m/z 698

H2N

SN

OH

O

O HN O

OO

+O+GSH

H2N

SN

OH

O

O HN O

OOCys

m/z 827

m/z 625

NH

SN

OH

O

O HN O

OO

m/z 520 H2N

SN

OH

O

O HN O

OO+O+Cys-Gly

Page 26: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

26

Isotope Triggered Trace Level Metabolite MSn

Page 27: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

27

Use of Isotopically Enhanced Labels for Plant Metabolite Identification

C13

C13

C13 HC13 H

C13

C13

F

O

Cl

Cl

N 2H

ON 2H

O

F

O

Cl

Cl

N 2H

ON 2H

O

C14H11Cl2FN2O3Mass 344.01308

(M+H)+ 345.02035Cas# 943831-98-9

C813C6H11Cl2FN2O3

Mass 350.03320(M+H)+ 351.04048

Blend of A and B yields significant +2, +6, +8 isotopic pattern

A

B A+B

346 348 350 352 354 356 358 360m/z

Inte

nsity

345.0204

347.0174

349.0145348.0208

351.0405

353.0375

355.0346

6.0201

1.997150

100

346 348 350 352 354 356 358 360m/z

351.0405

353.0375

355.0346

50

100

346 348 350 352 354 356 358 360m/z

345.0204

347.0174

349.0145348.0208

50

100 A B

Page 28: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

28

Feature-Specific Filters for Trace Level Labeled Metabolite ID

The feature-specific filters in ID-X method editor allow user to build sophisticated instrument method to capture trace level metabolites present in complex matrices, triggering MSn for confident identification and structure elucidation.

Isotope triggering By delta mass: Sulfur, Chlorine By isotope peak relative intensity By customer-defined mass difference

Comprehensive, feature-specific filters to trigger low abundant components MSn

Page 29: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

29

Feature Specific Filters Capture Ions of Interest for MSn

Targeted Isotopic Ratio

Targeted Mass Difference

Page 30: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

30

Isotopic Filtering of Mass Spectra

Page 31: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

31

Xenobiotics: Labeled Metabolite Identification in Complex Matrices

Structure Elucidation Workflow

• Xenobiotic material is applied as mixture of natural and a stable isotope-labeled material to create an ‘un-natural’ isotope cluster in resulting metabolites

• ‘Mass-Difference’ filtered data dependent method acquires OT-MS/MS, (monoisotopic), Ultra High Resolution OT-SIM (Selected Ion Monitoring), IT-MS3 and IT-MS2 (full isotope window)

• Unique workflow provides comprehensive spectral data that enables full structural elucidation of unknown metabolites

Ultra High Resolution, High Specificity Experimental Design

isotope34S

HR monoisotopic MS2

UHR 500K SIM

IT ‘full isotope’ MS2IT-MS3

Data courtesy of Dr. Jeff Gilbert, Dow AgroSciences

Page 32: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

32

MS3 Analysis of Trace Level Components

Customized Workflow

• ‘Targeted Mass Difference’ filter allows specific triggering of MS/MS scans on precursors that have peaks with a specified mass difference

• High specificity in experimental design allows the detection of trace components with 500K resolution for elemental composition determination

• High sensitivity MS3 analysis provides fragmentation spectra allowing structure validation

• This highly selective workflow increases throughput by 2X vs. a traditional targeted workflowTime (min)

1 2 3 4 5 6 7 8 9 10 11 12 13

Glucose Conjugate of Demethylated Parent

200 300 400 500 600 700 800 900 1000m/z

635.1054

631 632 633 634 635 636 637 638m/z

635.1054

632.1081

636.1086633.1112634.2493

637.1114

2.997

High Specificity MS3 Fragmentation of Metabolites

Isotope Mass Trigger

Data courtesy of Dr. Jeff Gilbert, Dow AgroSciences

Page 33: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

33

Mass Difference Triggered MSn of Plant Metabolites in Complex Biomatrix

Page 34: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

34

Orbitrap ID-X MS AcquireX Deep Scan Workflow for MetIDand Metabolomics Research

Page 35: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

35

AcquireX Deep Scan Workflow

Page 36: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

36

AcquireX | A New Acquisition Paradigm

Collect more meaningful data, not just more data to maximize productivity

Compared with Traditional DDA, AcquireX Deep Scan WorkflowSignificantly Increases ID by Triggering More MS/MS and MSn

Page 37: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

37

Compound Discoverer 3.0 for Data Processing

Page 38: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

38

Data Analysis Software, Database and Spectral Library Suite

Compound Discoverer 3.0 software

Thermo Scientific™TraceFinderTM softwaretargeted screening and Quan.

mzVault 2.0 Library Search and Manager

TM

HighChem LLC

Thermo E&L Compound Database

Mass Frontier 8.0spectral interpretation software

Page 39: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

39

Thermo Scientific Compound Discoverer Software (CD 3.0)

Complete Small Molecule Structure Analysis Platform

Component extraction based on HRAM and isotope pattern

Elemental composition prediction

Customizable feature set for advanced data processing

Searching online/offline spectral libraries and multiple databases for ID

Statistics and differential analysis

https://mycompounddiscoverer.com/

Page 40: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

40

Customizable Feature Set for Data Processing

Expected biotransformation list

Define adducts based on your experiments

Define ions based on your experiments

Add searchable spectral libraries tailored to your application, e.g., mzVault

Add searchable mass list tailored to your application

Ions belong to the same compound class e.g., parent fragments

• Default lists are available. • All lists can be customizable

to tailor fit your application. e.g., mzVault spectral library,

E&L mass list

Page 41: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

41

Fragment Ion Search - FISh Algorithm

• Fragment Ion Search – A means of detecting related components in complex samples• Data is scanned using fragmentation knowledge from a known structure• Components that share common fragments are detected• Fragments can be modified (metabolically or otherwise) and still be detected

Page 42: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

42

The Wizard Allows You to Build Processing Workflow

Creating a study and analysis use the guided “New Study and Analysis wizard” and build-in workflow templates

Descriptionfor each step

Compound Discoverer 3.0 Software

Page 43: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

43

Node-based Processing Workflow

Page 44: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

44

Result View – Data Interpretation

sub-tables

Page 45: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

45

Multiple Database Searching in Parallel to Identify Known Unknowns

Mirror plot for each mzVault hit: observed MS2 vs. library MS2 • Matches collision energy between raw file MS/MS and reference MS/MS

Sub table show detailed info for compound

Page 46: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

46

Compound Class Scoring: Tool to Find Structurally Related Compounds

• Create compound class using common fragments from parent and known metabolites

• Use Mass FrontierTM to predict fragments from parent mol file. Copy and paste the fragment structures to construct compound class.

Page 47: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

47

“Structure Proposal & Apply FISh” for Unknown ID

FISh stands for “Fragment Ion Search”

Page 48: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

48

mzCloud - Advanced High Resolution Mass Spectral Database

https://www.mzcloud.org

Free, Available to everyone, everywhere

mzCloud is a trademark of HighChem LLC, Slovakia

Page 49: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

49

mzCloud Spectral Library

Spectral treeReference library

Search by different terms

Metadata available forselected library entry

Recalibrated spectra

Permanent citable links for entry, tree, and spectra

Breakdown curves

mzCloud is a trademark of HighChem LLC, Slovakia

Page 50: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

50

Thermo Scientific mzVault 2.0

Exact Mass-Enabled Library Search and Management- Searching library – local mzCloud- Creating customer library

Page 51: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

51

Summary

High resolution mass spectrometry is the necessary tool for drug metabolite identification. Only Orbitrap MS delivers high quality HRAM data with high mass accuracy, isotopic pattern fidelity, and MSn for confident small molecule structure characterization.

Orbitrap ID-X MS AcquireX data acquisition workflows generate background exclusion lists and inclusion lists automatically, which minimizes matrix interferences and increase triggering MSn of drug-related ions. AcquireX improves overall metabolite ID and small molecule structure analysis efficiency, quality, and accuracy!

Compound Discoverer 3.0, Mass Frontier 8.0, and mzCloud suite facilitate confident small molecule structure analyses.

Page 52: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

52

Thermo Scientific Orbitrap ID-X MS for Natural Product Research and Traditional Medicine

Page 53: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

53

Thank you!

[email protected]

Visit: www.planetorbitrap.com

Page 54: Search for What's Missing: Unknown Compound ...€¦ · −Radio-labeled (13. C, 14. C, 3. H) • E&L analysis −Extractables ... • Toxicity assessments, clinic trails ... •

54

Thank You

Please return our survey to receive a drink ticket for our daily networking event where you can continue discussions with our experts!